{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T23:46:09Z","timestamp":1793231169698,"version":"4.5.0"},"reference-count":61,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T00:00:00Z","timestamp":1652313600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>X-ray computed tomography (XCT) is regularly employed in geomechanics to non-destructively measure the solid and pore fractions of soil and rock from reconstructed 3D images. With the increasing availability of high-resolution XCT imaging systems, researchers now seek to measure microfabric parameters such as the number and area of interparticle contacts, which can then be used to inform soil behaviour modelling techniques. However, recent research has evidenced that conventional image processing methods consistently overestimate the number and area of interparticle contacts, mainly due to acquisition-driven image artefacts. The present study seeks to address this issue by systematically assessing the role of XCT acquisition parameters in the accurate detection of interparticle contacts. To this end, synchrotron XCT has been applied to a hexagonal close-packed arrangement of glass pellets with and without a prescribed separation between lattice layers. Different values for the number of projections, exposure time, and rotation range have been evaluated. Conventional global grey value thresholding and novel U-Net segmentation methods have been assessed, followed by local refinements at the presumptive contacts, as per recently proposed contact detection routines. The effect of the different acquisition set-ups and segmentation techniques on contact detection performance is presented and discussed, and optimised workflows are proposed.<\/jats:p>","DOI":"10.3390\/jimaging8050135","type":"journal-article","created":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T21:46:53Z","timestamp":1652392013000},"page":"135","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["On Acquisition Parameters and Processing Techniques for Interparticle Contact Detection in Granular Packings Using Synchrotron Computed Tomography"],"prefix":"10.3390","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6940-9918","authenticated-orcid":false,"given":"Fernando","family":"Alvarez-Borges","sequence":"first","affiliation":[{"name":"Diamond Light Source Ltd., Harwell Science & Innovation Campus, Didcot OX11 0DE, UK"},{"name":"Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharif","family":"Ahmed","sequence":"additional","affiliation":[{"name":"Diamond Light Source Ltd., Harwell Science & Innovation Campus, Didcot OX11 0DE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6708-1085","authenticated-orcid":false,"given":"Robert C.","family":"Atwood","sequence":"additional","affiliation":[{"name":"Diamond Light Source Ltd., Harwell Science & Innovation Campus, Didcot OX11 0DE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,5,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1680\/geot.1996.46.3.529","article-title":"Void ratio evolution inside shear bands in triaxial sand specimens studied by computed tomography","volume":"46","author":"Desrues","year":"1996","journal-title":"G\u00e9otechnique"},{"key":"ref_2","first-page":"151","article-title":"Assessment of soil structure using X-ray computed tomography","volume":"Volume 215","author":"Mees","year":"2003","journal-title":"Applications of X-ray Computed Tomography in the Geosciences"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1680\/geot.2008.58.4.249","article-title":"Spatial variation of void ratio and shear band thickness in sand using X-ray computed tomography","volume":"58","author":"Alshibli","year":"2008","journal-title":"G\u00e9otechnique"},{"key":"ref_4","first-page":"38","article-title":"Investigation of pile penetration in calcareous soft rock using X-ray computed tomography","volume":"22","author":"Ahmed","year":"2021","journal-title":"Int. J. Phys. Model. Geotech."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1520\/GTJ20120075","article-title":"Quantification of Grain, Pore, and Fluid Microstructure of Unsaturated Sand from X-Ray Computed Tomography Images","volume":"35","author":"Willson","year":"2012","journal-title":"Geotech. Test. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"04014275","DOI":"10.1061\/(ASCE)MT.1943-5533.0001246","article-title":"Quantifying Morphology of Sands Using 3D Imaging","volume":"27","author":"Alshibli","year":"2015","journal-title":"J. Mater. Civ. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1680\/jgeot.16.P.278","article-title":"Quantification of the morphology of shelly carbonate sands using 3D images","volume":"68","author":"Kong","year":"2018","journal-title":"G\u00e9otechnique"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Alam, M.F., Haque, A., and Ranjith, P.G. (2018). A Study of the Particle-Level Fabric and Morphology of Granular Soils under One-Dimensional Compression Using Insitu X-ray CT Imaging. Materials, 11.","DOI":"10.3390\/ma11060919"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1016\/j.sandf.2018.08.008","article-title":"Experimental investigation of inter-particle contact evolution of sheared granular materials using X-ray micro-tomography","volume":"58","author":"Cheng","year":"2018","journal-title":"Soils Found."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"105268","DOI":"10.1016\/j.enggeo.2019.105268","article-title":"On the kinematics of shelly carbonate sand using X-ray micro tomography","volume":"261","author":"Kong","year":"2019","journal-title":"Eng. Geol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.jmps.2017.10.003","article-title":"All you need is shape: Predicting shear banding in sand with LS-DEM","volume":"111","author":"Kawamoto","year":"2018","journal-title":"J. Mech. Phys. Solids"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1680\/jgeot.18.T.030","article-title":"A micro finite-element model for soil behaviour: Experimental evaluation for sand under triaxial compression","volume":"70","author":"Nadimi","year":"2020","journal-title":"G\u00e9otechnique"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1680\/jgeot.19.P.212","article-title":"DEM modelling of mini-triaxial test based on one-to-one mapping of sand particles","volume":"71","author":"Wu","year":"2021","journal-title":"G\u00e9otechnique"},{"key":"ref_14","unstructured":"Nakagawa, M., and Luding, S. (2009). Image Segmentation Techniques for Granular Materials. Powders and Grains: Proceedings of the 6th International Conference on Micromechanics of Granular Media, American Institute of Physics."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.compgeo.2015.12.014","article-title":"3D characterization of sand particle-to-particle contact and morphology","volume":"74","author":"Druckrey","year":"2016","journal-title":"Comput. Geotech."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"013711","DOI":"10.1063\/1.2838584","article-title":"Validation of x-ray microfocus computed tomography as an imaging tool for porous structures","volume":"79","author":"Kerckhofs","year":"2008","journal-title":"Rev. Sci. Instrum."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"124007","DOI":"10.1088\/1361-6501\/aa8dbf","article-title":"On the metrology of interparticle contacts in sand from x-ray tomography images","volume":"28","author":"Wiebicke","year":"2017","journal-title":"Meas. Sci. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/S0098-3004(00)00116-3","article-title":"Acquisition, optimization and interpretation of X-ray computed tomographic imagery: Applications to the geosciences","volume":"27","author":"Ketcham","year":"2001","journal-title":"Comput. Geosci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.earscirev.2013.04.003","article-title":"High-resolution X-ray computed tomography in geosciences: A review of the current technology and applications","volume":"123","author":"Cnudde","year":"2013","journal-title":"Earth Sci. Rev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"115502","DOI":"10.1088\/0957-0233\/22\/11\/115502","article-title":"A test object with parallel grooves for calibration and accuracy assessment of industrial computed tomography (CT) metrology","volume":"22","author":"Kiekens","year":"2011","journal-title":"Meas. Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.cirp.2011.05.006","article-title":"Computed tomography for dimensional metrology","volume":"60","author":"Kruth","year":"2011","journal-title":"CIRP Ann. Manuf. Techn."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Hsieh, J. (2015). Computed Tomography: Principles, Design, Artifacts, and Recent Advances, SPIE. [3rd ed.].","DOI":"10.1117\/3.2197756"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"19123","DOI":"10.1038\/s41598-021-98697-z","article-title":"Automatic sentation tool for 3D digital rocks by deep learning","volume":"11","author":"Phan","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Varfolomeev, I., Yakimchuk, I., and Safonov, I. (2019). An Application of Deep Neural Networks for Segmentation of Microtomographic Images of Rock Samples. Computers, 8.","DOI":"10.3390\/computers8040072"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.precisioneng.2020.08.006","article-title":"Effect of the number of projections on dimensional measurements with X-ray computed tomography","volume":"66","author":"Smith","year":"2020","journal-title":"Precis. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1145\/3065386","article-title":"ImageNet classification with deep convolutional neural networks","volume":"60","author":"Krizhevsky","year":"2017","journal-title":"Commun. ACM"},{"key":"ref_27","unstructured":"Goodfellow, I., Bengio, Y., and Courville, A. (2016). Deep Learning, MIT Press."},{"key":"ref_28","unstructured":"Brown, W.E. (1992). Plastics in Food Packaging: Properties, Design, and Fabrication, Marcel Dekker, Inc."},{"key":"ref_29","unstructured":"(2021, November 21). AR-GLAS Technical Details. Available online: https:\/\/www.schott.com\/en-gb\/products\/ar-glas-p1000366\/technical-details."},{"key":"ref_30","unstructured":"(2021, November 12). X-Ray Attenuation & Absorption Calculator. Available online: https:\/\/web-docs.gsi.de\/~stoe_exp\/web_programs\/x_ray_absorption\/index.php."},{"key":"ref_31","unstructured":"(2021, November 12). X-ray Form Factor, Attenuation, and Scattering Tables, Available online: https:\/\/physics.nist.gov\/PhysRefData\/FFast\/html\/form.html."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Willmott, P. (2011). An Introduction to Synchrotron Radiation: Techniques and Applications, John Wiley & Sons, Ltd.","DOI":"10.1002\/9781119970958"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Toda, H. (2021). X-ray CT: Hardware and Software Techniques, Springer Nature Singapore Pte Ltd.","DOI":"10.1007\/978-981-16-0590-1"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1107\/S1600577515003513","article-title":"I12: The Joint Engineering, Environment and Processing (JEEP) beamline at Diamond Light Source","volume":"22","author":"Drakopoulos","year":"2015","journal-title":"J. Synchrotron. Radiat."},{"key":"ref_35","unstructured":"(2021, July 15). I12 Detectors. Available online: https:\/\/www.diamond.ac.uk\/Instruments\/Imaging-and-Microscopy\/I12\/Detectors-at-I12.html."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1179\/174328008X277803","article-title":"Recent advances in X-ray microtomography applied to materials","volume":"53","author":"Stock","year":"2008","journal-title":"Int. Mater. Rev."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1088\/0031-9155\/40\/11\/007","article-title":"Cone-beam CT for radiotherapy applications","volume":"40","author":"Cho","year":"1995","journal-title":"Phys. Med. Biol"},{"key":"ref_38","unstructured":"Kalender, W.A. (2011). Computed Tomography. Fundamentals, System Technology, Image Quality, Applications, Publicis Publishing."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"012003","DOI":"10.1088\/1361-6501\/ac354a","article-title":"Review of high-speed imaging with lab-based x-ray computed tomography","volume":"33","author":"Zwanenburg","year":"2021","journal-title":"Meas. Sci. Technol."},{"key":"ref_40","unstructured":"Wadeson, N., and Basham, M. (2016). Savu: A Python-based, MPI Framework for Simultaneous Processing of Multiple, N-dimensional, Large Tomography Datasets. arXiv."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1098\/rsta.2014.0398","article-title":"A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source","volume":"373","author":"Atwood","year":"2015","journal-title":"Philos. Trans. R. Soc. A"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"28396","DOI":"10.1364\/OE.26.028396","article-title":"Superior techniques for eliminating ring artifacts in X-ray micro-tomography","volume":"26","author":"Vo","year":"2018","journal-title":"Opt. Express"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"19078","DOI":"10.1364\/OE.22.019078","article-title":"Reliable method for calculating the center of rotation in parallel-beam tomography","volume":"22","author":"Vo","year":"2014","journal-title":"Opt. Express"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2236","DOI":"10.1073\/pnas.68.9.2236","article-title":"Three-dimensional reconstruction from radiographs and electron micrographs: Application of convolutions instead of Fourier transforms","volume":"68","author":"Ramachandran","year":"1971","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"25129","DOI":"10.1364\/OE.24.025129","article-title":"Fast and flexible X-ray tomography using the ASTRA toolbox","volume":"24","author":"Palenstijn","year":"2016","journal-title":"Opt. Express"},{"key":"ref_46","first-page":"234","article-title":"U-Net: Convolutional Networks for Biomedical Image Segmentation","volume":"Volume 9351","author":"Navab","year":"2015","journal-title":"Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI 2015. Lecture Notes in Computer Science"},{"key":"ref_47","unstructured":"Alvarez-Borges, F., Atwood, R., and Ahmed, S. (2021). Tomography Data for Interparticle Contact Detection Analysis in Spheroidal Granular Packings, Zenodo. Dataset."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Smith, A.G., Han, E., Petersen, J., Olsen, N.A.F., Giese, C., Athmann, M., Dresb\u00f8ll, D.B., and Thorup-Kristensen, K. (2020). RootPainter: Deep Learning Segmentation of Biological Images with Corrective Annotation. bioRxiv.","DOI":"10.1101\/2020.04.16.044461"},{"key":"ref_49","unstructured":"Smith, A.G., and \u00d8rting, S. (2021, May 01). RootPainter, Version 0.2.5. Available online: https:\/\/github.com\/Abe404\/root_painter."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Alvarez-Borges, F.J., King, O.N., Madhusudhan, B., Connolley, T., Basham, M., and Ahmed, S.I. (2021). U-Net Segmentation Methods for Variable-Contrast XCT Images of Methane-Bearing Sand Essoar. Earth Space Sci. Open Arch. ESSOAr.","DOI":"10.1002\/essoar.10506807.1"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Smith, A.G., Petersen, J., Terrones-Campos, C., Berthelsen, A.K., Forbes, N.J., Darkner, S., Specht, L., and Vogelius, I.R. (2021). RootPainter3D: Interactive-machine-learning enables rapid and accurate contouring for radiotherapy. arXiv, preprint.","DOI":"10.1002\/mp.15353"},{"key":"ref_52","unstructured":"Van Rijsbergen, C.J. (1979). Information Retrieval, Butterworth. [2nd ed.]."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","article-title":"A Threshold Selection Method from Gray-Level Histograms","volume":"9","author":"Otsu","year":"1979","journal-title":"IEEE Trans. Syst. Man Cybern. Syst."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1109\/CVPR.2005.38","article-title":"A non-local algorithm for image denoising","volume":"Volume 2","author":"Schmid","year":"2005","journal-title":"Proceedings of the 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR\u201905)"},{"key":"ref_55","unstructured":"Wiebicke, M. (2020). Experimental Analysis of the Evolution of Fabric in Granular Soils upon Monotonic Loading and Load Reversals. [Ph.D. Thesis, Technische Universit\u00e4t Dresden]."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"2286","DOI":"10.21105\/joss.02286","article-title":"spam: Software for Practical Analysis of Materials","volume":"5","author":"Stamati","year":"2020","journal-title":"J. Open Source Softw."},{"key":"ref_57","unstructured":"(2021, November 16). SPAM Documentation. Available online: https:\/\/ttk.gricad-pages.univ-grenoble-alpes.fr\/spam\/index.html."},{"key":"ref_58","first-page":"1115","article-title":"Differential Effect of 180\u00b0 and 360\u00b0 Acquisition Orbits on the Accuracy of SPECT Imaging: Quantitative Evaluation in Phantoms","volume":"43","author":"Liu","year":"2002","journal-title":"J. Nucl. Med."},{"key":"ref_59","unstructured":"(2019). Non-Destructive Testing\u2014Radiation Methods for Computed Tomography Part 2: Principles, Equipment and Samples (Standard No. BS EN ISO 15708-2:2019)."},{"key":"ref_60","unstructured":"Schielein, R., Schr\u00f6pfer, S., Kiunke, M., Zabler, S., and Kasperl, S. (2014). Quantitative evaluation of CT Images by means of Shannon Entropy. 11th European Conference on Non-Destructive Testing, Proceedings of the 11th European Conference on Non-Destructive Testing, Prague, Czech Republic, 6\u201310 October 2014, European Federation for Non-Destructive Testing."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.precisioneng.2020.08.004","article-title":"Review of the influence of noise in X-ray computed tomography measurement uncertainty","volume":"66","author":"Thompson","year":"2020","journal-title":"Precis. Eng."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/5\/135\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:09:51Z","timestamp":1760137791000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/5\/135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,12]]},"references-count":61,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,5]]}},"alternative-id":["jimaging8050135"],"URL":"https:\/\/doi.org\/10.3390\/jimaging8050135","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,12]]}}}