{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,5]],"date-time":"2025-12-05T03:41:41Z","timestamp":1764906101158,"version":"build-2065373602"},"reference-count":34,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,5,31]],"date-time":"2022-05-31T00:00:00Z","timestamp":1653955200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Academy of Finland","award":["#336791","#325146"],"award-info":[{"award-number":["#336791","#325146"]}]},{"name":"Academy of Finland","award":["#336791","#325146"],"award-info":[{"award-number":["#336791","#325146"]}]},{"name":"Vilho, Yrjo and Kalle Vaisala Fund","award":["#336791","#325146"],"award-info":[{"award-number":["#336791","#325146"]}]},{"name":"P\u00e4ivikki and Sakari Sohlberg Foundation","award":["#336791","#325146"],"award-info":[{"award-number":["#336791","#325146"]}]},{"name":"Doctoral Programme in Science, Technology, and Computing (SCITECO) of the University of Eastern Finland","award":["#336791","#325146"],"award-info":[{"award-number":["#336791","#325146"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Quantitative MRI (qMRI) methods allow reducing the subjectivity of clinical MRI by providing numerical values on which diagnostic assessment or predictions of tissue properties can be based. However, qMRI measurements typically take more time than anatomical imaging due to requiring multiple measurements with varying contrasts for, e.g., relaxation time mapping. To reduce the scanning time, undersampled data may be combined with compressed sensing (CS) reconstruction techniques. Typical CS reconstructions first reconstruct a complex-valued set of images corresponding to the varying contrasts, followed by a non-linear signal model fit to obtain the parameter maps. We propose a direct, embedded reconstruction method for T1\u03c1 mapping. The proposed method capitalizes on a known signal model to directly reconstruct the desired parameter map using a non-linear optimization model. The proposed reconstruction method also allows directly regularizing the parameter map of interest and greatly reduces the number of unknowns in the reconstruction, which are key factors in the performance of the reconstruction method. We test the proposed model using simulated radially sampled data from a 2D phantom and 2D cartesian ex vivo measurements of a mouse kidney specimen. We compare the embedded reconstruction model to two CS reconstruction models and in the cartesian test case also the direct inverse fast Fourier transform. The T1\u03c1 RMSE of the embedded reconstructions was reduced by 37\u201376% compared to the CS reconstructions when using undersampled simulated data with the reduction growing with larger acceleration factors. The proposed, embedded model outperformed the reference methods on the experimental test case as well, especially providing robustness with higher acceleration factors.<\/jats:p>","DOI":"10.3390\/jimaging8060157","type":"journal-article","created":{"date-parts":[[2022,5,31]],"date-time":"2022-05-31T09:24:29Z","timestamp":1653989069000},"page":"157","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Embedded Quantitative MRI T1\u03c1 Mapping Using Non-Linear Primal-Dual Proximal Splitting"],"prefix":"10.3390","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5044-3203","authenticated-orcid":false,"given":"Matti","family":"Hanhela","sequence":"first","affiliation":[{"name":"Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1763-2990","authenticated-orcid":false,"given":"Antti","family":"Paajanen","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5678-0689","authenticated-orcid":false,"given":"Mikko J.","family":"Nissi","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5621-795X","authenticated-orcid":false,"given":"Ville","family":"Kolehmainen","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,5,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1002\/nbm.3518","article-title":"Quantitative rotating frame relaxometry methods in MRI","volume":"29","author":"Gilani","year":"2016","journal-title":"NMR Biomed."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1002\/nbm.1102","article-title":"Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage","volume":"19","author":"Borthakur","year":"2006","journal-title":"NMR Biomed."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1002\/1522-2594(200012)44:6<833::AID-MRM3>3.0.CO;2-F","article-title":"Interrelations of T(1) and diffusion of water in acute cerebral ischemia of the rat","volume":"44","author":"Kettunen","year":"2000","journal-title":"Magn. Reson. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1097\/00004647-200010000-00007","article-title":"Early detection of irreversible cerebral ischemia in the rat using dispersion of the magnetic resonance imaging relaxation time, T1rho","volume":"20","author":"Grohn","year":"2000","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.jjcc.2015.03.005","article-title":"Endogenous contrast T1rho cardiac magnetic resonance for myocardial fibrosis in hypertrophic cardiomyopathy patients","volume":"66","author":"Wang","year":"2015","journal-title":"J. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1148\/radiol.11101638","article-title":"T1rho MR imaging is sensitive to evaluate liver fibrosis: An experimental study in a rat biliary duct ligation model","volume":"259","author":"Wang","year":"2011","journal-title":"Radiology"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1002\/jmri.24677","article-title":"T(1)rho MRI of human musculoskeletal system","volume":"41","author":"Wang","year":"2015","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1002\/jor.24780","article-title":"Evaluation of articular cartilage with quantitative MRI in an equine model of post-traumatic osteoarthritis","volume":"39","author":"Kajabi","year":"2021","journal-title":"J. Orthop. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/42.97598","article-title":"Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)","volume":"10","author":"Jackson","year":"1991","journal-title":"IEEE Trans. Med. Imag."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1109\/TIT.2005.862083","article-title":"Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information","volume":"52","author":"Candes","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1109\/TIT.2006.871582","article-title":"Compressed sensing","volume":"52","author":"Donoho","year":"2006","journal-title":"IEEE Trans. Inf. Theory"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1259\/bjr.20150487","article-title":"Compressed sensing MRI: A review of the clinical literature","volume":"88","author":"Jaspan","year":"2015","journal-title":"Brit. J. Radiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/mrm.25130","article-title":"PANDA-T1\u03c1: Integrating principal component analysis and dictionary learning for fast T1\u03c1 mapping","volume":"73","author":"Zhu","year":"2015","journal-title":"Magn. Reson. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1002\/mrm.25702","article-title":"Accelerated T1\u03c1 acquisition for knee cartilage quantification using compressed sensing and data-driven parallel imaging: A feasibility study","volume":"75","author":"Pandit","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1002\/mrm.27138","article-title":"Accelerating 3D-T1\u03c1 mapping of cartilage using compressed sensing with different sparse and low rank models","volume":"80","author":"Zibetti","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1002\/mrm.28019","article-title":"Accelerated mono- and biexponential 3D-T1\u03c1 relaxation mapping of knee cartilage using golden angle radial acquisitions and compressed sensing","volume":"83","author":"Zibetti","year":"2020","journal-title":"Magn. Reson. Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"055012","DOI":"10.1088\/0266-5611\/30\/5\/055012","article-title":"A primal\u2013dual hybrid gradient method for nonlinear operators with applications to MRI","volume":"30","author":"Valkonen","year":"2014","journal-title":"Inverse Probl."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Guo, R., El-Rewaidy, H., Assana, S., Cai, X., Amyar, A., Chow, K., Bi, X., Yankama, T., Cirillo, J., and Pierce, P. (2022). Accelerated cardiac T1 mapping in four heartbeats with inline MyoMapNet: A deep learning-based T1 estimation approach. J. Cardiovasc. Magn. Reson., 24.","DOI":"10.1186\/s12968-021-00834-0"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"3211","DOI":"10.1002\/mrm.28659","article-title":"Magnetic resonance parameter mapping using model-guided self-supervised deep learning","volume":"85","author":"Liu","year":"2021","journal-title":"Magn. Reson. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e4416","DOI":"10.1002\/nbm.4416","article-title":"Rapid MR relaxometry using deep learning: An overview of current techniques and emerging trends","volume":"35","author":"Feng","year":"2022","journal-title":"NMR Biomed."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1109\/TSP.2002.807005","article-title":"Nonuniform fast Fourier transforms using min-max interpolation","volume":"51","author":"Fessler","year":"2003","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1553\/etna_vol52s509","article-title":"Primal-dual block-proximal splitting for a class of non-convex problems","volume":"52","author":"Mazurenko","year":"2020","journal-title":"Electron. Trans. Numer. Anal."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1007\/s10851-010-0251-1","article-title":"A first-order primal-dual algorithm for convex problems with applications to imaging","volume":"40","author":"Chambolle","year":"2011","journal-title":"J. Math. Imaging Vision"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1109\/TMI.2006.885337","article-title":"An optimal radial profile order based on the golden ratio for time-resolved MRI","volume":"26","author":"Winkelmann","year":"2007","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Bernstein, M.A., King, K.F., and Zhou, X.J. (2004). Handbook of MRI Pulse Sequences, Academic Press.","DOI":"10.1016\/B978-012092861-3\/50021-2"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/mrm.21134","article-title":"Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rho off-weighted imaging","volume":"57","author":"Witschey","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_27","unstructured":"(2022, May 03). Michigan Image Reconstruction Toolbox (MIRT). Available online: https:\/\/github.com\/JeffFessler\/mirt."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: The application of compressed sensing for rapid MR imaging","volume":"58","author":"Lustig","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1002\/mrm.21236","article-title":"Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint","volume":"57","author":"Block","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1137\/090769521","article-title":"Total generalized variation","volume":"3","author":"Bredies","year":"2010","journal-title":"SIAM J. Imaging Sci."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"3506","DOI":"10.1109\/TIP.2014.2329448","article-title":"Adaptive Regularization of the NL-Means: Application to Image and Video Denoising","volume":"23","author":"Sutour","year":"2014","journal-title":"IEEE Trans. Image Process"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1109\/TMI.2010.2090538","article-title":"MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning","volume":"30","author":"Ravishankar","year":"2011","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1002\/mrm.20241","article-title":"Reduction of residual dipolar interaction in cartilage by spin-lock technique","volume":"52","author":"Akella","year":"2004","journal-title":"Magn. Reson. Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1177\/1947603515569529","article-title":"T1rho Dispersion in Articular Cartilage: Relationship to Material Properties and Macromolecular Content","volume":"6","author":"Keenan","year":"2015","journal-title":"Cartilage"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/6\/157\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:22:32Z","timestamp":1760138552000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/6\/157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,31]]},"references-count":34,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["jimaging8060157"],"URL":"https:\/\/doi.org\/10.3390\/jimaging8060157","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2022,5,31]]}}}