{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T17:27:34Z","timestamp":1794590854805,"version":"4.9.1"},"reference-count":33,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,6,7]],"date-time":"2022-06-07T00:00:00Z","timestamp":1654560000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>The mandibular incisive canal (MIC) is a small bony channel located in the interforaminal region; it represents the anterior continuation of the mandibular canal. Cone-beam computed tomography (CBCT) is the most commonly utilized radiological technique for assessing the MIC. The main purpose of this study was to evaluate the detectability and variability in measurements of the MIC on CBCT. A total of 220 dentate hemi-mandibles were retrospectively selected for this study. For each hemi-mandible, the detectability, diameter, and distance of the MIC from anatomical landmarks (cortical plates and tooth apices) were evaluated in consensus by two observers. The analysis was performed at four different levels (first premolar, canine, lateral incisor, and central incisor) and was repeated after one month. The variability of MIC measurements was expressed as the coefficient of repeatability (CR), obtained from the Bland\u2013Altman analysis. The MIC detection rate reduced from the first premolar to the central incisor (from 82.3% to 0.5%). The CR of MIC measurements (diameter and distances from anatomical landmarks) was \u22640.74 mm. Although the MIC is difficult to detect in a non-negligible percentage of cases, the limited variability in measurements confirms that CBCT is an effective technique for the assessment of the MIC.<\/jats:p>","DOI":"10.3390\/jimaging8060161","type":"journal-article","created":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T02:25:33Z","timestamp":1654827933000},"page":"161","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Detection Rate and Variability in Measurement of Mandibular Incisive Canal on Cone-Beam Computed Tomography: A Study of 220 Dentate Hemi-Mandibles from Italy"],"prefix":"10.3390","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4761-2923","authenticated-orcid":false,"given":"Andrea","family":"Borghesi","sequence":"first","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Di Salvo","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro","family":"Ciolli","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teresa","family":"Falcone","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Ravanelli","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Farina","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Carapella","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/j.1600-0501.2011.02393.x","article-title":"Safe zone for bone harvesting from the interforaminal region of the mandible","volume":"24","author":"Nambiar","year":"2013","journal-title":"Clin. Oral. Implant. Res."},{"key":"ref_2","first-page":"e3","article-title":"Anatomy of Mandibular Vital Structures. Part II: Mandibular Incisive Canal, Mental Foramen and Associated Neurovascular Bundles in Relation with Dental Implantology","volume":"1","author":"Juodzbalys","year":"2010","journal-title":"J. Oral. Maxillofac. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1111\/j.1708-8208.2009.00228.x","article-title":"Mandibular incisive canal: Cone beam computed tomography","volume":"14","author":"Pires","year":"2012","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1007\/s00276-017-1934-8","article-title":"Anatomical landmarks of mandibular interforaminal region related to dental implant placement with 3D CBCT: Comparison between edentulous and dental mandibles","volume":"40","author":"Sener","year":"2018","journal-title":"Surg. Radiol. Anat."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"409","DOI":"10.5115\/acb.21.113","article-title":"Comprehensive review of the incisive branch of the inferior alveolar nerve","volume":"54","author":"Caughey","year":"2021","journal-title":"Anat. Cell Biol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1007\/s00784-010-0459-x","article-title":"Histology and intramandibular course of the inferior alveolar nerve","volume":"15","author":"Kqiku","year":"2011","journal-title":"Clin. Oral. Investig."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.archoralbio.2011.09.007","article-title":"A review of the mandibular and maxillary nerve supplies and their clinical relevance","volume":"57","author":"Rodella","year":"2012","journal-title":"Arch. Oral. Biol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1007\/s00276-018-2040-2","article-title":"Analysis of the frequency of visualization of morphological variations in anatomical bone features in the mandibular interforaminal region through cone-beam computed tomography","volume":"40","author":"Tedesco","year":"2018","journal-title":"Surg. Radiol. Anat."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1111\/j.1708-8208.2003.tb00204.x","article-title":"Clinical assessment and surgical implications of anatomic challenges in the anterior mandible","volume":"5","author":"Mraiwa","year":"2003","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"e420","DOI":"10.4317\/medoral.17520","article-title":"Characteristics of anatomical landmarks in the mandibular interforaminal region: A cone-beam computed tomography study","volume":"17","author":"Parnia","year":"2012","journal-title":"Med. Oral. Patol. Oral. Cir. Bucal."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e405","DOI":"10.1097\/SCS.0b013e318292c7d5","article-title":"Anterior mandibular zone safe for implants","volume":"24","author":"Topan","year":"2013","journal-title":"J. Craniofac. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1097\/ID.0b013e318264d70d","article-title":"Brisk, pulsatile bleeding from the anterior mandibular incisive canal during implant surgery: A case report and use of an active hemostatic matrix to terminate acute bleeding","volume":"21","author":"Lee","year":"2012","journal-title":"Implant. Dent."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.joms.2008.05.352","article-title":"Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: A second attempt introducing cone beam computed tomography","volume":"67","author":"Uchida","year":"2009","journal-title":"J. Oral. Maxillofac. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1111\/cid.12474","article-title":"Characteristics of intrabony nerve canals in mandibular interforaminal region by using cone-beam computed tomography and a recommendation of safe zone for implant and bone harvesting","volume":"19","author":"Yang","year":"2017","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1007\/s00276-016-1779-6","article-title":"Study of the mandibular incisive canal anatomy using cone beam computed tomography","volume":"39","author":"Kabak","year":"2017","journal-title":"Surg. Radiol. Anat."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s10006-018-0716-8","article-title":"Anatomic evaluation of the incisive canal with cone beam computed tomography and its relevance to surgical procedures in the mental region: A retrospective study in a Brazilian population","volume":"22","author":"Gomes","year":"2018","journal-title":"Oral. Maxillofac. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.morpho.2018.12.005","article-title":"Mandibular incisive canal and lingual foramina characterization by cone-beam computed tomography","volume":"103","author":"Gilis","year":"2019","journal-title":"Morphologie"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1007\/s12663-018-1168-2","article-title":"Evaluation of Mandibular Incisive Canal using Cone Beam Computed Tomography in Malaysians","volume":"18","author":"Lim","year":"2019","journal-title":"J. Maxillofac. Oral. Surg."},{"key":"ref_19","first-page":"241","article-title":"Prevalence and Morphology of Mandibular Incisive Canal: Comparison among Healthy, Periodontitis and Edentulous Mandibles in a Population of the Beijing Area Using Cone-beam Computed Tomography","volume":"22","author":"Zhang","year":"2019","journal-title":"Chin. J. Dent. Res."},{"key":"ref_20","first-page":"205","article-title":"Assessment of prevalence and position of mandibular incisive canal: A cone beam computed tomography study","volume":"32","author":"Ayesha","year":"2019","journal-title":"Ci Ji Yi Xue Za Zhi"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"149","DOI":"10.4103\/ams.ams_144_19","article-title":"CBCT Evaluation of the Vital Mandibular Interforaminal Anatomical Structures","volume":"10","author":"Puri","year":"2020","journal-title":"Ann. Maxillofac. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e337","DOI":"10.4317\/medoral.23350","article-title":"Mandibular incisive canal-related prevalence, morphometric parameters, and implant placement implications: A multicenter study of 847 CBCT scans","volume":"25","author":"Barbosa","year":"2020","journal-title":"Med. Oral. Patol. Oral. Cir. Bucal."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4103\/jos.jos_108_21","article-title":"Cone-beam computed tomography evaluation of prevalence and location of mandibular incisive canal in patients attending King Saud University Dental Hospital","volume":"10","author":"Alshamrani","year":"2021","journal-title":"J. Orthod. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1038\/sj.dmfr.4600719","article-title":"Appearance, location, course, and morphology of the mandibular incisive canal: An assessment on spiral CT scan","volume":"31","author":"Jacobs","year":"2002","journal-title":"Dentomaxillofac. Radiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.joen.2011.02.022","article-title":"Dental magnetic resonance imaging: Making the invisible visible","volume":"37","author":"Idiyatullin","year":"2011","journal-title":"J. Endod."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s00276-011-0910-y","article-title":"Study of inferior dental canal and its contents using high-resolution magnetic resonance imaging","volume":"34","author":"Krasny","year":"2012","journal-title":"Surg. Radiol. Anat."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Reda, R., Zanza, A., Cicconetti, A., Bhandi, S., Miccoli, G., Gambarini, G., and Di Nardo, D. (2021). Ultrasound Imaging in Dentistry: A Literature Overview. J. Imaging, 7.","DOI":"10.3390\/jimaging7110238"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s00276-018-1969-5","article-title":"Five mental foramina in the same mandible: CBCT findings of an unusual anatomical variant","volume":"40","author":"Borghesi","year":"2018","journal-title":"Surg. Radiol. Anat."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"471","DOI":"10.5603\/FM.a2020.0057","article-title":"Unilateral triple mandibular canal with double mandibular foramen: Cone-beam computed tomography findings of an unexpected anatomical variant","volume":"80","author":"Borghesi","year":"2021","journal-title":"Folia Morphol."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Lu, M.J., Zhong, W.H., Liu, Y.X., Miao, H.Z., Li, Y.C., and Ji, M.H. (2016). Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. Int. J. Biostat., 12.","DOI":"10.1515\/ijb-2015-0039"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.ajodo.2011.06.034","article-title":"Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth","volume":"141","author":"Patcas","year":"2012","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Ruetters, M., Kim, T.S., Hagenfeld, D., Kronsteiner, D., Gehrig, H., Lux, C.J., and Sen, S. (J. Orofac. Orthop., 2021). Ex vivo assessment of the buccal and oral bone by CBCT, J. Orofac. Orthop., Online ahead of print.","DOI":"10.1007\/s00056-021-00335-w"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/6\/161\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:25:15Z","timestamp":1760138715000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/8\/6\/161"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,7]]},"references-count":33,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["jimaging8060161"],"URL":"https:\/\/doi.org\/10.3390\/jimaging8060161","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,7]]}}}