{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T18:22:55Z","timestamp":1790706175343,"version":"4.1.0"},"reference-count":164,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2023,5,16]],"date-time":"2023-05-16T00:00:00Z","timestamp":1684195200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Loughborough University"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Portable gamma cameras suitable for intraoperative imaging are in active development and testing. These cameras utilise a range of collimation, detection, and readout architectures, each of which can have significant and interacting impacts on the performance of the system as a whole. In this review, we provide an analysis of intraoperative gamma camera development over the past decade. The designs and performance of 17 imaging systems are compared in depth. We discuss where recent technological developments have had the greatest impact, identify emerging technological and scientific requirements, and predict future research directions. This is a comprehensive review of the current and emerging state-of-the-art as more devices enter clinical practice.<\/jats:p>","DOI":"10.3390\/jimaging9050102","type":"journal-article","created":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T01:52:41Z","timestamp":1684288361000},"page":"102","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Intraoperative Gamma Cameras: A Review of Development in the Last Decade and Future Outlook"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9232-6280","authenticated-orcid":false,"given":"Andrew L.","family":"Farnworth","sequence":"first","affiliation":[{"name":"Department of Physics, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9589-6249","authenticated-orcid":false,"given":"Sarah L.","family":"Bugby","sequence":"additional","affiliation":[{"name":"Department of Physics, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Herrmann, K., Nieweg, O.E., and Povoski, S.P. (2016). Radioguided Surgery, Springer.","DOI":"10.1007\/978-3-319-26051-8"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2012.05.002","article-title":"Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applications","volume":"29","author":"Tsuchimochi","year":"2013","journal-title":"Phys. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1080\/17434440.2019.1642104","article-title":"Recent advances in nuclear and hybrid detection modalities for image-guided surgery","volume":"16","author":"Rietbergen","year":"2019","journal-title":"Expert Rev. Med. Devices"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2967","DOI":"10.1002\/hed.26780","article-title":"Utility of intraoperative digital scintigraphy in radioguided parathyroidectomy","volume":"43","author":"Creighton","year":"2021","journal-title":"Head Neck"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Perkins, A.C., and Lees, J.E. (2016). Gamma Cameras for Interventional and Intraoperative Imaging, CRC Press.","DOI":"10.1201\/9781315370224"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Herrmann, K., Nieweg, O.E., and Povoski, S.P. (2016). (Eds.) Radioguided Surgery, Current Applications and Innovative Directions in Clinical Practice, Springer.","DOI":"10.1007\/978-3-319-26051-8"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1118\/1.3081412","article-title":"Imaging performance comparison between a scintillator based and a CdTe semiconductor based photon counting compact gamma camera","volume":"36","author":"Russo","year":"2009","journal-title":"Med. Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1118\/1.3555034","article-title":"Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging","volume":"38","author":"Russo","year":"2011","journal-title":"Med. Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.ejmp.2019.12.024","article-title":"CdTe compact gamma camera for coded aperture imaging in radioguided surgery","volume":"69","author":"Russo","year":"2020","journal-title":"Phys. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1109\/TNS.2014.2308284","article-title":"Development and Characterization of a Round Hand-Held Silicon Photomultiplier Based Gamma Camera for Intraoperative Imaging","volume":"61","author":"Popovic","year":"2014","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.ejmp.2013.10.004","article-title":"Characterisation of a high resolution small field of view portable gamma camera","volume":"30","author":"Bugby","year":"2014","journal-title":"Phys. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"229","DOI":"10.26502\/jcsct.5079037","article-title":"The Role of Intra-Operative Mobile Gamma Camera and Gamma Probe in Detection of Sentinel Lymph Node in Early Stage Breast Cancer","volume":"3","author":"Ibraheem","year":"2019","journal-title":"J. Cancer Sci. Clin. Ther."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Perkins, A.C., and Lees, J.E. (2016). Gamma Cameras for Interventional and Intraoperative Imaging, CRC Press.","DOI":"10.1201\/9781315370224"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s40336-016-0198-3","article-title":"Hybrid tracers and devices for intraoperative imaging: The future for radioguided surgery?","volume":"4","author":"Gambini","year":"2016","journal-title":"Clin. Transl. Imaging"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.ejmp.2014.08.004","article-title":"A scheme for assessing the performance characteristics of small field-of-view gamma cameras","volume":"31","author":"Bhatia","year":"2015","journal-title":"Phys. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1093\/rpd\/ncy229","article-title":"Characterization of a small FOV portable GC: MediPROBE","volume":"183","author":"Acampa","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.ejmp.2016.06.004","article-title":"Design and development of a dedicated portable gamma camera system for intra-operative imaging","volume":"32","author":"Kaviani","year":"2016","journal-title":"Phys. Med."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Netter, E., Pinot, L., M\u00e9nard, L., Duval, M.A., Janvier, B., Lefebvre, F., Siebert, R., and Charon, Y. (November, January 24). The Tumor Resection Camera (TReCam), a multipixel imaging probe for radio-guided surgery. Proceedings of the 2009 IEEE Nuclear Science Symposium Conference Record (NSS\/MIC), Orlando, FL, USA.","DOI":"10.1109\/NSSMIC.2009.5402022"},{"key":"ref_19","unstructured":"United States Food and Drug Administration (2022, February 24). 510(k) Summary for Portable Gamma Camera: Sentinella 102, Available online: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf9\/K092471.pdf."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.nima.2016.03.060","article-title":"Development of a high resolution gamma camera system using finely grooved GAGG scintillator","volume":"821","author":"Yamamoto","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.radphyschem.2018.02.018","article-title":"Dual-modality imaging with a ultrasound-gamma device for oncology","volume":"147","author":"Polito","year":"2018","journal-title":"Radiat. Phys. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"4210","DOI":"10.1118\/1.2358199","article-title":"Performance tests of two portable mini gamma cameras for medical applications","volume":"33","author":"Gimenez","year":"2006","journal-title":"Med. Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1016\/j.ejmp.2015.12.002","article-title":"Investigation of an SFOV hybrid gamma camera for thyroid imaging","volume":"32","author":"Bugby","year":"2016","journal-title":"Phys. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/s13550-020-00729-8","article-title":"Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients","volume":"10","author":"Kogler","year":"2020","journal-title":"EJNMMI Res."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Cherry, S.R., Sorenson, J.A., and Phelps, M.E. (2012). Physics in Nuclear Medicine, Elsevier Health Sciences.","DOI":"10.1016\/B978-1-4160-5198-5.00001-0"},{"key":"ref_26","unstructured":"Moyer, R. (1974). Low-Energy Multihole Converging Collimator Compared with a Pinhole Collimator, Technical Report; Searle Radiographics Inc."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1063\/1.1722607","article-title":"Gamma-ray collimator penetration and scattering effects","volume":"28","author":"Mather","year":"1957","journal-title":"J. Appl. Phys."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1109\/42.938241","article-title":"Analytic determination of pinhole collimator sensitivity with penetration","volume":"20","author":"Metzler","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1109\/TMI.2004.826951","article-title":"Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator","volume":"23","author":"Accorsi","year":"2004","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1016\/j.sab.2011.09.011","article-title":"The xraylib library for X-ray\u2013matter interactions. Recent developments","volume":"66","author":"Schoonjans","year":"2011","journal-title":"Spectrochim. Acta Part B At. Spectrosc."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.nima.2016.06.124","article-title":"A novel fully integrated handheld gamma camera","volume":"832","author":"Massari","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.nima.2015.01.083","article-title":"SiPM arrays and miniaturized readout electronics for compact gamma camera","volume":"787","author":"Dinu","year":"2015","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.21037\/abs-19-108","article-title":"Interest of a hand-held gamma camera (TReCam) in breast SNOLL procedure","volume":"4","author":"Bricou","year":"2020","journal-title":"Ann. Breast Surg."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Perkins, A.C., and Lees, J.E. (2016). Gamma Cameras for Interventional and Intraoperative Imaging, CRC Press.","DOI":"10.1201\/9781315370224"},{"key":"ref_35","unstructured":"Hamamatsu Photonics, K.K. (2015). Flat Panel Type Multianode Photomultiplier Tube Assembly H9500 Series, H9500-03, Technical Report; Hamamatsu Photonics K.K. (Electron Tube Division)."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"C02022","DOI":"10.1088\/1748-0221\/9\/02\/C02022","article-title":"ROC chips for imaging calorimetry at the International Linear Collider","volume":"9","author":"Callier","year":"2014","journal-title":"J. Instrum."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.nuclphysbps.2009.10.109","article-title":"Revisited position arithmetics for LaBr3: Ce continuous crystals","volume":"197","author":"Pani","year":"2009","journal-title":"Nucl. Phys. B-Proc. Suppl."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/MNM.0b013e32835a7ccd","article-title":"Phantom study of a new hand-held \u03b3-imaging probe for radio-guided surgery","volume":"34","author":"Ferretti","year":"2013","journal-title":"Nucl. Med. Commun."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"134731","DOI":"10.1155\/2015\/134731","article-title":"Radioguided parathyroidectomy with portable mini gamma-camera for the treatment of primary hyperparathyroidism","volume":"2015","author":"Casella","year":"2015","journal-title":"Int. J. Endocrinol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"e132","DOI":"10.1097\/RLU.0b013e31827a278d","article-title":"Intraoperative hand-held imaging \u03b3-camera for sentinel node detection in patients with breast cancer: Feasibility evaluation and preliminary experience on 16 patients","volume":"38","author":"Chondrogiannis","year":"2013","journal-title":"Clin. Nucl. Med."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1016\/j.nima.2007.03.037","article-title":"New high spatial resolution portable camera in medical imaging","volume":"577","author":"Trotta","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_42","unstructured":"Hamamatsu Photonics, K.K. (2022, February 25). Flat Panel Type Multianode PMT Assembly H8500 Series\/H10966 Series. Available online: http:\/\/hamamatsu.com.cn\/UserFiles\/DownFile\/Product\/H8500_H10966_TPMH1327E02.pdf."},{"key":"ref_43","first-page":"61","article-title":"Performance evaluation of a solid-state detector based handheld gamma camera system","volume":"1","author":"Knoll","year":"2014","journal-title":"Front. Biomed. Technol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1515\/cdbme-2021-2036","article-title":"Hybrid handheld gamma-ultrasound prototype for radioguided surgery: Initial results","volume":"7","author":"Pashazadeh","year":"2021","journal-title":"Curr. Dir. Biomed. Eng."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s40658-020-00313-y","article-title":"Characterisation of a hand-held CZT-based gamma camera for 177Lu imaging","volume":"7","author":"Roth","year":"2020","journal-title":"EJNMMI Phys."},{"key":"ref_46","unstructured":"SurgicEye GmbH (2022, February 25). declipseSPECT Imaging Probe. Available online: https:\/\/www.surgiceye.com\/for-healthcare-professionals\/declipsespect-imaging-probe\/."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1148\/radiol.14132415","article-title":"Hybrid integration of real-time US and freehand SPECT: Proof of concept in patients with thyroid diseases","volume":"271","author":"Freesmeyer","year":"2014","journal-title":"Radiology"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.nima.2008.09.036","article-title":"Characterization and selection of CZT detector modules for HEX experiment onboard Chandrayaan-1","volume":"598","author":"Vadawale","year":"2009","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s10686-010-9189-y","article-title":"Instruments of RT-2 experiment onboard CORONAS-PHOTON and their test and evaluation II: RT-2\/CZT payload","volume":"29","author":"Kotoch","year":"2011","journal-title":"Exp. Astron."},{"key":"ref_50","first-page":"1433","article-title":"Evaluation of mobile gamma camera imaging in sentinel lymph node biopsy for melanoma independent of pre-operative lymphoscintigraphy","volume":"53","author":"Judge","year":"2012","journal-title":"J. Nucl. Med."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.jss.2022.12.013","article-title":"Evaluation of Preoperative and Intraoperative Mobile Gamma Camera Imaging in Sentinel Lymph Node Biopsy for Melanoma Independent of Preoperative Lymphoscintigraphy","volume":"285","author":"Judge","year":"2023","journal-title":"J. Surg. Res."},{"key":"ref_52","unstructured":"Goertzen, A.L., Thiessen, J.D., McIntosh, B., Simpson, M.J., and Schellenberg, J. (November, January 27). Characterization of a handheld gamma camera for intraoperative use for sentinel lymph node biopsy. Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS\/MIC), Seoul, Republic of Korea."},{"key":"ref_53","unstructured":"Imando, T.A., Dinu, N., Callier, S., Cuisy, D., Gaspard, M., Pinot, L., Puill, V., Raux, L., Trochet, S., and Menard, L. (2012, January 13\u201315). Miniaturized multi-channels SiPM read-out electronics for medical imaging application. Proceedings of the International Workshop on New Photon-Detectors (PhotoDet2012), LAL Orsay, France."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1016\/j.phpro.2012.02.486","article-title":"EASIROC, an easy & versatile readout device for SiPM","volume":"37","author":"Callier","year":"2012","journal-title":"Phys. Procedia"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1384","DOI":"10.1118\/1.1755570","article-title":"Design and tests of a portable mini gamma camera","volume":"31","author":"Benlloch","year":"2004","journal-title":"Med. Phys."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s00259-006-0239-7","article-title":"Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy","volume":"34","author":"Ortega","year":"2007","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"700","DOI":"10.2967\/jnumed.109.071407","article-title":"A portable gamma-camera for intraoperative detection of sentinel nodes in the head and neck region","volume":"51","author":"Vermeeren","year":"2010","journal-title":"J. Nucl. Med."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1097\/RLU.0000000000000874","article-title":"A New Portable Hybrid Camera for Fused Optical and Scintigraphic Imaging","volume":"41","author":"Hellingman","year":"2015","journal-title":"Clin. Nucl. Med."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Perkins, A.C., and Lees, J.E. (2016). Gamma Cameras for Interventional and Intraoperative Imaging, CRC Press.","DOI":"10.1201\/9781315370224"},{"key":"ref_60","first-page":"4","article-title":"Development of a leakage monitoring system in isolated limb perfusion with portable gamma camera","volume":"40","author":"Molina","year":"2021","journal-title":"Rev. Esp. Med. Nucl. Imagen Mol. Engl. Ed."},{"key":"ref_61","unstructured":"Point Grey Research (2022, February 24). Bumblebee 2 Stereo Vision System Preliminary Specifications. Available online: http:\/\/www.nast-group.caltech.edu\/~murray\/dgc05\/upload\/9\/92\/Point_grey_bumblebee_2_product_brochure.pdf."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.nima.2014.04.060","article-title":"Two-dimensional diced scintillator array for innovative, fine-resolution gamma camera","volume":"765","author":"Fujita","year":"2014","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_63","unstructured":"Hamamatsu Photonics, K.K. (2022, February 25). Position Sensitive Photomultiplier Tubes R8900-00-C12, R8900U-00-c12. Available online: https:\/\/www.hamamatsu.com\/content\/dam\/hamamatsu-photonics\/sites\/documents\/99_SALES_LIBRARY\/etd\/R8900(U)-00-C12_TPMH1299E.pdf."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1097\/MNM.0000000000000546","article-title":"\u03bb-Eye: A high-sensitivity \u03b3 imaging probe for axillary sentinel lymph node mapping","volume":"37","author":"Georgiou","year":"2016","journal-title":"Nucl. Med. Commun."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"P09010","DOI":"10.1088\/1748-0221\/7\/09\/P09010","article-title":"Optimization of a gamma imaging probe for axillary sentinel lymph mapping","volume":"7","author":"Georgiou","year":"2012","journal-title":"J. Instrum."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"T11004","DOI":"10.1088\/1748-0221\/8\/11\/T11004","article-title":"Low cost FPGA based data acquisition system for a gamma imaging probe","volume":"8","author":"Fysikopoulos","year":"2013","journal-title":"J. Instrum."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Massari, R., Soluri, A., Caputo, D., and Ronchi, S. (2015, January 18\u201319). Low power readout circuits for large area silicon photomultiplier array. Proceedings of the 2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI), Gallipoli, Italy.","DOI":"10.1109\/IWASI.2015.7184962"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"C12033","DOI":"10.1088\/1748-0221\/6\/12\/C12033","article-title":"A high resolution Small Field Of View (SFOV) gamma camera: A columnar scintillator coated CCD imager for medical applications","volume":"6","author":"Lees","year":"2011","journal-title":"J. Instrum."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1097\/MNM.0000000000000715","article-title":"A novel compact small field of view hybrid gamma camera: First clinical results","volume":"38","author":"Ng","year":"2017","journal-title":"Nucl. Med. Commun."},{"key":"ref_70","unstructured":"Teledyne e2v (UK) Limited (2022, February 25). CCD97-00 Datasheet. Available online: https:\/\/www.teledyneimaging.com\/download\/f68f9696-ff81-45c2-80e0-3fc83fac6c67\/."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Lees, J.E., Bugby, S.L., Alqahtani, M.S., Jambi, L.K., Dawood, N.S., McKnight, W.R., Ng, A.H., and Perkins, A.C. (2017). A multimodality hybrid gamma-optical camera for intraoperative imaging. Sensors, 17.","DOI":"10.3390\/s17030554"},{"key":"ref_72","doi-asserted-by":"crossref","unstructured":"Cencelli, V.O., de Notaristefani, F., Fabbri, A., Petulla, F., D\u2019Abramo, E., Pani, R., Cinti, M., Bennati, P., Boccaccio, P., and Lanconelli, N. (November, January 24). A gamma camera with the useful field of view coincident with the crystal area. Proceedings of the 2009 IEEE Nuclear Science Symposium Conference Record (NSS\/MIC), Orlando, FL, USA.","DOI":"10.1109\/NSSMIC.2009.5402162"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.nima.2009.03.169","article-title":"A dual-modality ultrasound-gamma system: Monte Carlo simulations of the scintillation imager","volume":"607","author":"Meo","year":"2009","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_74","unstructured":"Fabbri, A., De Notaristefani, F., Cencelli, V.O., Bennati, P., Cinti, M., Petulla, F., Pellegrini, R., De Vincentis, G., and Pani, R. (November, January 30). Independent channel readout system for a 2 \u00d7 2 array of H8500 with SBA photocatode. Proceedings of the IEEE Nuclear Science Symposuim & Medical Imaging Conference, Knoxville, TN, USA."},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Pani, R., Cinti, M.N., Bennati, P., Pellegrini, R., Scaf\u00e9, R., Bettiol, M., Marchioni, C., Meo, S.L., and Fabbri, A. (2011, January 23\u201329). New position arithmetic for scintillation camera based on floating weight system. Proceedings of the 2011 IEEE Nuclear Science Symposium Conference Record, Valencia, Spain.","DOI":"10.1109\/NSSMIC.2011.6152616"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"161705","DOI":"10.1016\/j.nima.2018.12.020","article-title":"Development of a sub-miniature gamma camera for multimodal imaging system","volume":"954","author":"Jung","year":"2020","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Di Lillo, F., Corvino, V., Mettivier, G., Sarno, A., and Russo, P. (November, January 29). Performance of the MediPROBE compact gamma camera for coded aperture imaging. Proceedings of the 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS\/MIC\/RTSD), Strasbourg, France.","DOI":"10.1109\/NSSMIC.2016.8069612"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"P10021","DOI":"10.1088\/1748-0221\/8\/10\/P10021","article-title":"A hybrid camera for locating sources of gamma radiation in the environment","volume":"8","author":"Lees","year":"2013","journal-title":"J. Instrum."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"045031","DOI":"10.1088\/1361-6560\/abd955","article-title":"Stereoscopic portable hybrid gamma imaging for source depth estimation","volume":"66","author":"Bugby","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"C03037","DOI":"10.1088\/1748-0221\/11\/03\/C03037","article-title":"Integrated ultrasound and gamma imaging probe for medical diagnosis","volume":"11","author":"Pani","year":"2016","journal-title":"J. Instrum."},{"key":"ref_81","unstructured":"Kross, B.J., McKisson, J., Stolin, A., Weisenberger, A.G., and Zorn, C. (2012). Collimator with Attachment Mechanism and System, Technical Report; Thomas Jefferson National Accelerator Facility."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.amsu.2020.06.020","article-title":"Improving ergonomics in the operating room for orthopaedic surgeons in order to reduce work-related musculoskeletal injuries","volume":"56","author":"Alaqeel","year":"2020","journal-title":"Ann. Med. Surg."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"012019","DOI":"10.1088\/1742-6596\/1248\/1\/012019","article-title":"Operator motion effects of a small field of view hybrid gamma camera: To hold or not to hold, that is the question?","volume":"1248","author":"Ng","year":"2019","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.nima.2005.08.091","article-title":"New imaging probe with crystals integrated in the collimator\u2019s square holes","volume":"554","author":"Soluri","year":"2005","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_85","unstructured":"Royle, G., Royle, N., Pani, R., and Speller, R. (1995, January 21\u201328). Design of high resolution collimators for small gamma cameras. Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, San Francisco, CA, USA."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ijrmhm.2016.10.015","article-title":"Injection molding of tungsten powder treated by jet mill with high powder loading: A solution for fabrication of dense tungsten component at relative low temperature","volume":"62","author":"Li","year":"2017","journal-title":"Int. J. Refract. Met. Hard Mater."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40658-018-0238-3","article-title":"Characterisation of the attenuation properties of 3D-printed tungsten for use in gamma camera collimation","volume":"6","author":"Gear","year":"2019","journal-title":"EJNMMI Phys."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"104998","DOI":"10.1016\/j.ijrmhm.2019.104998","article-title":"Laser powder bed fusion of a pure tungsten ultra-fine single pinhole collimator for use in gamma ray detector characterisation","volume":"84","author":"Sidambe","year":"2019","journal-title":"Int. J. Refract. Met. Hard Mater."},{"key":"ref_89","unstructured":"Netter, E. (2011). Developpement de la Mini Gamma Camera TReCam Pour Assister le Traitement Chirurgical du Cancer du Sein. [Ph.D. Thesis, Universit\u00e9 Paris-Diderot VII]."},{"key":"ref_90","unstructured":"Crystal Photonics GmbH (2022, February 24). CrystalCam Hand Held Gamma Camera Product Brochure. Available online: https:\/\/jrtassociates.com\/pdfs\/CrystalCam.pdf."},{"key":"ref_91","doi-asserted-by":"crossref","unstructured":"Pani, R., Pellegrini, R., Bennati, P., Cinti, M.N., Scaf\u00e8, R., De Vincentis, G., Navarria, F., Moschini, G., Cencelli, V.O., and De Notaristefani, F. (2009, January 10\u201315). Performance of a lanthanum bromide detector and a new conception collimator for radiopharmaceuticals molecular imaging in oncology. Proceedings of the AIP Conference Proceedings. American Institute of Physics, Fort Worth, TX, USA.","DOI":"10.1063\/1.3120080"},{"key":"ref_92","unstructured":"Mettivier, G., and Farnworth, A.L. Personal communication."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s11307-011-0494-2","article-title":"Optimization of coded aperture radioscintigraphy for sentinel lymph node mapping","volume":"14","author":"Fujii","year":"2012","journal-title":"Mol. Imaging Biol."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"012016","DOI":"10.1088\/1742-6596\/637\/1\/012016","article-title":"3-D localization of gamma ray sources with coded apertures for medical applications","volume":"637","author":"Kaissas","year":"2015","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"505","DOI":"10.3769\/radioisotopes.51.505","article-title":"Analysis of Tomographical Information of Tracer Distribution by Using a CdZnTe Semiconductor-Based Gamma Counter Equipped with Using Coded Aperture","volume":"51","author":"Anzai","year":"2002","journal-title":"Radioisotopes"},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.radmeas.2016.08.002","article-title":"Coded-aperture imaging systems: Past, present and future development\u2014A review","volume":"92","author":"Gamage","year":"2016","journal-title":"Radiat. Meas."},{"key":"ref_97","unstructured":"Derenzo, S., Boswell, M., Weber, M., and Brennan, K. (2022, September 06). Scintillation Properties Database, Available online: http:\/\/scintillator.lbl.gov\/."},{"key":"ref_98","doi-asserted-by":"crossref","unstructured":"Borrazzo, C., Bettiol, M., Bennati, P., Preziosi, E., Fabbri, A., Scaf\u00e8, R., Pellegrini, R., and Pani, R. (November, January 29). Monte Carlo simulation to evaluate factors affecting imaging performances of compact scintillation gamma camera. Proceedings of the 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS\/MIC\/RTSD), Strasbourg, France.","DOI":"10.1109\/NSSMIC.2016.8069537"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.nima.2017.11.010","article-title":"LaBr3: Ce and NaI: Tl performance comparison for single photon emission detector","volume":"912","author":"Bettiol","year":"2018","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_100","doi-asserted-by":"crossref","unstructured":"Xie, S., Zhang, X., Zhang, Y., Ying, G., Huang, Q., Xu, J., and Peng, Q. (2020). Evaluation of various scintillator materials in radiation detector design for positron emission tomography (PET). Crystals, 10.","DOI":"10.3390\/cryst10100869"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"P09009","DOI":"10.1088\/1748-0221\/11\/09\/P09009","article-title":"A comparison of CsI: Tl and GOS in a scintillator-CCD detector for nuclear medicine imaging","volume":"11","author":"Bugby","year":"2016","journal-title":"J. Instrum."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.1109\/TNS.2013.2251661","article-title":"Design and performance of a resistor multiplexing readout circuit for a SiPM detector","volume":"60","author":"Goertzen","year":"2013","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1109\/TNS.2017.2649563","article-title":"Development of a multipurpose gamma-ray imaging detector module with enhanced expandability","volume":"64","author":"Min","year":"2017","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_104","unstructured":"Hamamatsu Photonics, K.K. (2022, February 25). Hamamatsu News\u2014MPPC Array S12641\/S12642\/S12892\/S12894 Series. Available online: https:\/\/www.hamamatsu-news.de\/issues\/hamamatsu_news_02_2014\/files\/assets\/basic-html\/index.html#9."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1088\/0031-9155\/45\/3\/315","article-title":"Performance of a PSPMT based detector for scintimammography","volume":"45","author":"Williams","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"P12010","DOI":"10.1088\/1748-0221\/8\/12\/P12010","article-title":"Study of position reconstruction of a LaBr3: Ce continuous scintillation crystal for medical applications","volume":"8","author":"Fabbri","year":"2013","journal-title":"J. Instrum."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.nima.2010.10.077","article-title":"Super spatial resolution (SSR) method for scintigraphic imaging","volume":"626","author":"Trinci","year":"2011","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.nima.2016.11.026","article-title":"Monte Carlo optimization of crystal configuration for pixelated molecular SPECT scanners","volume":"844","author":"Mahani","year":"2017","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_109","unstructured":"Barrett, H.H., and Swindell, W. (1996). Radiological Imaging: The Theory of Image Formation, Detection, and Processing, Academic Press."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.nima.2019.05.064","article-title":"Experimental evaluation of reconstruction algorithms for scintillation crystal array based on charge projection readout","volume":"937","author":"Shi","year":"2019","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"17TR01","DOI":"10.1088\/1361-6560\/ab7b2d","article-title":"The silicon photomultiplier: Fundamentals and applications of a modern solid-state photon detector","volume":"65","author":"Gundacker","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"ref_112","unstructured":"Knoll, G.F. (2010). Radiation Detection and Measurement, John Wiley & Sons."},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"P01007","DOI":"10.1088\/1748-0221\/11\/01\/P01007","article-title":"Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging","volume":"11","author":"Ballabriga","year":"2016","journal-title":"J. Instrum."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.nima.2007.08.079","article-title":"Timepix, a 65k programmable pixel readout chip for arrival time, energy and\/or photon counting measurements","volume":"581","author":"Llopart","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0168-9002(96)00292-6","article-title":"Characterization of CdZnTe and CdTe: Cl materials and their relationship to X-and \u03b3-ray detector performance","volume":"380","author":"Verger","year":"1996","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1103\/PhysRevLett.75.156","article-title":"Charge transport in arrays of semiconductor gamma-ray detectors","volume":"75","author":"Barrett","year":"1995","journal-title":"Phys. Rev. Lett."},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Wilson, M.D., Seller, P., Veale, M.C., and Sellin, P.J. (November, January 26). Investigation of the small pixel effect in CdZnTe detectors. Proceedings of the 2007 IEEE Nuclear Science Symposium Conference Record, Honolulu, HI, USA.","DOI":"10.1109\/NSSMIC.2007.4437231"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.nima.2019.06.017","article-title":"Energy-loss correction in charge sharing events for improved performance of pixellated compound semiconductors","volume":"940","author":"Bugby","year":"2019","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_119","unstructured":"Yang, C., Zannoni, E., and Meng, L.J. (2022, January 5\u201312). X-Y-Z-E 4-D Reconstruction of Charge Sharing Events in Small-Pixel CdTe and CZT Detectors Using Vector-Net and Joint-Net for Multi-Isotope Hyperspectral SPECT Imaging. Proceedings of the IEEE NPSS MIC RTSD, Milan, Italy."},{"key":"ref_120","first-page":"173","article-title":"Detector and telescope development for ProtoEXIST and fine beam measurements of spectral response of CZT detectors","volume":"Volume 5898","author":"Hong","year":"2005","journal-title":"Proceedings of the UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIV"},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1109\/TNS.2002.803788","article-title":"Medipix2: A 64k pixel readout chip with 55 \u03bcm square elements working in single photon counting mode","volume":"49","author":"Llopart","year":"2002","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_122","unstructured":"Lee, B., Kim, D., Chung, M.A., Baek, C.H., Han, D.H., Cha, H., Jeong, S., Yeom, J.Y., Lee, K., and Lee, H. (2022, January 5\u201312). Development of a Compact Gamma Camera with a Diverging Collimator for Iridium-192 Brachytherapy. Proceedings of the IEEE NPSS MIC RTSD, Milan, Italy."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"C01012","DOI":"10.1088\/1748-0221\/15\/01\/C01012","article-title":"Signal to noise ratio optimization for extended sources with a new kind of MURA masks","volume":"15","author":"Kaissas","year":"2020","journal-title":"J. Instrum."},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"P01006","DOI":"10.1088\/1748-0221\/18\/01\/P01006","article-title":"Quantitative comparison of planar coded aperture imaging reconstruction methods","volume":"18","author":"Rozhkov","year":"2023","journal-title":"J. Instrum."},{"key":"ref_125","doi-asserted-by":"crossref","unstructured":"Furenlid, L., May, M., Kupinski, M., Feng, Y., and Sabet, H. (2022, January 5\u201312). Comparison of Printed versus Machined Tungsten Collimators. Proceedings of the IEEE NPSS MIC RTSD, Milan, Italy.","DOI":"10.1109\/NSS\/MIC44845.2022.10398902"},{"key":"ref_126","unstructured":"Hu, Y., Fan, P., Lyu, Z., Qi, C., Liu, Y., and Ma, T. (2022, January 5\u201312). A High-Sensitivity Mobile Medical Gamma Camera with Mosaic-Patterned Scintillator-Glass Detector for Intraoperative Imaging Guidance. Proceedings of the IEEE NPSS MIC RTSD, Milan, Italy."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1016\/j.nima.2016.06.071","article-title":"Prototype of a single probe Compton camera for laparoscopic surgery","volume":"845","author":"Koyama","year":"2017","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/j.nima.2016.06.056","article-title":"Development of a compact scintillator-based high-resolution Compton camera for molecular imaging","volume":"845","author":"Kishimoto","year":"2017","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_129","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.1038\/s41598-017-02377-w","article-title":"First demonstration of multi-color 3-D in vivo imaging using ultra-compact Compton camera","volume":"7","author":"Kishimoto","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.nima.2015.08.041","article-title":"Development of new scintillators for medical applications","volume":"809","author":"Lecoq","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"2102439","DOI":"10.1002\/advs.202102439","article-title":"Structured scintillators for efficient radiation detection","volume":"9","author":"Lin","year":"2022","journal-title":"Adv. Sci."},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1109\/TRPMS.2021.3069624","article-title":"Metascintillators for ultrafast gamma detectors: A review of current state and future perspectives","volume":"6","author":"Konstantinou","year":"2021","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"ref_133","doi-asserted-by":"crossref","first-page":"1620","DOI":"10.1038\/s41598-018-38188-w","article-title":"Role of selenium addition to CdZnTe matrix for room-temperature radiation detector applications","volume":"9","author":"Roy","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_134","first-page":"1183804","article-title":"Optimization of CZTS gamma-ray detectors","volume":"Volume 11838","author":"Cherepy","year":"2021","journal-title":"Hard X-ray, Gamma-Ray, and Neutron Detector Physics XXIII"},{"key":"ref_135","doi-asserted-by":"crossref","first-page":"55","DOI":"10.3389\/fphy.2020.00055","article-title":"Thallium bromide gamma-ray spectrometers and pixel arrays","volume":"8","author":"Kim","year":"2020","journal-title":"Front. Phys."},{"key":"ref_136","doi-asserted-by":"crossref","first-page":"2002098","DOI":"10.1002\/advs.202002098","article-title":"Metal halide perovskites for high-energy radiation detection","volume":"7","author":"Kakavelakis","year":"2020","journal-title":"Adv. Sci."},{"key":"ref_137","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1038\/s41377-019-0191-5","article-title":"Single-photon avalanche diode imagers in biophotonics: Review and outlook","volume":"8","author":"Bruschini","year":"2019","journal-title":"Light. Sci. Appl."},{"key":"ref_138","first-page":"1200806","article-title":"Next generation fast sCMOS detector development for EUV and soft X-ray high-harmonic generation, semiconductor metrology, X-ray absorption spectroscopy, soft X-ray microscopy, and tomography","volume":"Volume 12008","author":"Busse","year":"2022","journal-title":"Photonic Instrumentation Engineering IX"},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1109\/TRPMS.2020.3002949","article-title":"Photon counting detectors for X-ray imaging with emphasis on CT","volume":"5","author":"Ballabriga","year":"2020","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"C10012","DOI":"10.1088\/1748-0221\/17\/10\/C10012","article-title":"Spectroscopic X-ray imaging at MHz frame rates\u2014The HEXITECMHz ASIC","volume":"17","author":"Jones","year":"2022","journal-title":"J. Instrum."},{"key":"ref_141","doi-asserted-by":"crossref","first-page":"C02016","DOI":"10.1088\/1748-0221\/8\/02\/C02016","article-title":"The Medipix3RX: A high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging","volume":"8","author":"Ballabriga","year":"2013","journal-title":"J. Instrum."},{"key":"ref_142","doi-asserted-by":"crossref","unstructured":"Ricci, R., Kostou, T., Chatzipapas, K., Fysikopoulos, E., Loudos, G., Montalto, L., Scalise, L., Rinaldi, D., and David, S. (2019). Monte Carlo optical simulations of a small FoV gamma camera. effect of scintillator thicknesses and septa materials. Crystals, 9.","DOI":"10.3390\/cryst9080398"},{"key":"ref_143","doi-asserted-by":"crossref","first-page":"455","DOI":"10.3938\/jkps.72.455","article-title":"Effects of Varying Matching Between Collimator Hole and Scintillator Pixel on Gamma Camera Image Resolution","volume":"72","author":"Kim","year":"2018","journal-title":"J. Korean Phys. Soc."},{"key":"ref_144","doi-asserted-by":"crossref","unstructured":"Jambi, L.K., Lees, J.E., Bugby, S.L., Bhatia, B.S., Alqahtani, M.S., Dawood, N.S., Ng, A.H., and Perkins, A.C. (November, January 29). Comparison of columnar and pixelated scintillators for small field of view hybrid gamma camera imaging. Proceedings of the 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS\/MIC\/RTSD), Strasbourg, France.","DOI":"10.1109\/NSSMIC.2016.8069402"},{"key":"ref_145","unstructured":"Myronakis, M.E., Zvelebil, M., and Darambara, D.G. (November, January 27). Effect of collimator design and anode dimensions on gamma-cameras based on pixelated CdZnTe. Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS\/MIC), Seoul, Republic of Korea."},{"key":"ref_146","doi-asserted-by":"crossref","unstructured":"Hatefi Hesari, S., Haque, M.A., and McFarlane, N. (2021). A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems. Photonics, 8.","DOI":"10.3390\/photonics8070266"},{"key":"ref_147","doi-asserted-by":"crossref","first-page":"163220","DOI":"10.1016\/j.nima.2019.163220","article-title":"Characterization of the acquisition modes implemented in Pixirad-1\/Pixie-III X-ray Detector: Effects of charge sharing correction on spectral resolution and image quality","volume":"955","author":"Bravin","year":"2020","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_148","doi-asserted-by":"crossref","first-page":"C01095","DOI":"10.1088\/1748-0221\/6\/01\/C01095","article-title":"First CT using Medipix3 and the MARS-CT-3 spectral scanner","volume":"6","author":"Walsh","year":"2011","journal-title":"J. Instrum."},{"key":"ref_149","doi-asserted-by":"crossref","first-page":"P06021","DOI":"10.1088\/1748-0221\/17\/06\/P06021","article-title":"Automatic detection of scintillation light splashes using conventional and deep learning methods","volume":"17","author":"Jiang","year":"2022","journal-title":"J. Instrum."},{"key":"ref_150","doi-asserted-by":"crossref","unstructured":"Decuyper, M., Deprez, K., and Mollet, P. (2022, January 5\u201312). Neural networks for gamma interaction positioning in continuous SPECT detectors. Proceedings of the 2022 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference (IEEE NPSS MIC RTSD), Milano, Italy.","DOI":"10.1109\/NSS\/MIC44845.2022.10399306"},{"key":"ref_151","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.nucmedbio.2019.01.010","article-title":"Dual-isotope imaging allows in vivo immunohistochemistry using radiolabelled antibodies in tumours","volume":"70","author":"Knight","year":"2019","journal-title":"Nucl. Med. Biol."},{"key":"ref_152","first-page":"361","article-title":"Hyperspectral SPECT: Time to revisit the spectral domain for gamma ray imaging?","volume":"59","author":"Zannoni","year":"2018","journal-title":"J. Nucl. Med."},{"key":"ref_153","doi-asserted-by":"crossref","first-page":"C06002","DOI":"10.1088\/1748-0221\/10\/06\/C06002","article-title":"LaBr3: Ce small FOV gamma camera with excellent energy resolution for multi-isotope imaging","volume":"10","author":"Pani","year":"2015","journal-title":"J. Instrum."},{"key":"ref_154","doi-asserted-by":"crossref","first-page":"C02022","DOI":"10.1088\/1748-0221\/8\/02\/C02022","article-title":"Dual isotope imaging with LaBr3: Ce crystal and H8500 PSPMT","volume":"8","author":"Fabbri","year":"2013","journal-title":"J. Instrum."},{"key":"ref_155","doi-asserted-by":"crossref","first-page":"P08027","DOI":"10.1088\/1748-0221\/7\/08\/P08027","article-title":"A CdTe detector for hyperspectral SPECT imaging","volume":"7","author":"Scuffham","year":"2012","journal-title":"J. Instrum."},{"key":"ref_156","doi-asserted-by":"crossref","unstructured":"Mont\u00e9mont, G., Bohuslav, P., Dubosq, J., Feret, B., Monnet, O., Oehling, O., Skala, L., Stanchina, S., Verger, L., and Werthmann, G. (2017, January 21\u201328). NuVISION: A portable multimode gamma camera based on HiSPECT imaging module. Proceedings of the 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS\/MIC), Atlanta, GA, USA.","DOI":"10.1109\/NSSMIC.2017.8532713"},{"key":"ref_157","doi-asserted-by":"crossref","first-page":"106362","DOI":"10.1016\/j.radmeas.2020.106362","article-title":"Development and characterization of a handheld radiation detector for radio-guided surgery","volume":"135","author":"Bedir","year":"2020","journal-title":"Radiat. Meas."},{"key":"ref_158","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1038\/s41551-022-00866-6","article-title":"Simultaneous visualization of multiple radionuclides in vivo","volume":"6","author":"Yagishita","year":"2022","journal-title":"Nat. Biomed. Eng."},{"key":"ref_159","doi-asserted-by":"crossref","first-page":"190","DOI":"10.23736\/S1824-4785.21.03370-7","article-title":"Therapeutic applications of radioactive sources: From image-guided brachytherapy to radio-guided surgical resection","volume":"65","author":"Dickhoff","year":"2021","journal-title":"Q. J. Nucl. Med. Mol. Imaging"},{"key":"ref_160","doi-asserted-by":"crossref","unstructured":"Wu, Z., Fabbri, A., Yang, X., Qi, Y., Zhan, B., Wang, J., Liu, Z., Cencelli, V., and Tsui, B. (2022, January 5\u201312). Design and development of a high-resolution handheld gamma camera for thyroid and sentinel nodes imaging. Proceedings of the 2022 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference (IEEE NPSS MIC RTSD), Milano, Italy.","DOI":"10.1109\/NSS\/MIC44845.2022.10399163"},{"key":"ref_161","unstructured":"Shen, Z.M., and Meng, L.J. (November, January 27). Development and evaluation of compact and high resolution CdTe\/CZT detectors for handheld gamma camera and probe application. Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS\/MIC), Seoul, Republic of Korea."},{"key":"ref_162","doi-asserted-by":"crossref","first-page":"C01059","DOI":"10.1088\/1748-0221\/12\/01\/C01059","article-title":"Imaging of spatially extended hot spots with coded apertures for intra-operative nuclear medicine applications","volume":"12","author":"Kaissas","year":"2017","journal-title":"J. Instrum."},{"key":"ref_163","doi-asserted-by":"crossref","first-page":"8325","DOI":"10.1364\/OE.26.008325","article-title":"Proof-of-concept of a multimodal laparoscope for simultaneous NIR\/gamma\/visible imaging using wavelength division multiplexing","volume":"26","author":"Kang","year":"2018","journal-title":"Opt. Express"},{"key":"ref_164","doi-asserted-by":"crossref","first-page":"2364","DOI":"10.1364\/OE.415732","article-title":"SiPM-based gamma detector with a central GRIN lens for a visible\/NIRF\/gamma multi-modal laparoscope","volume":"29","author":"Han","year":"2021","journal-title":"Opt. Express"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/5\/102\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:36:18Z","timestamp":1760124978000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/5\/102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,16]]},"references-count":164,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["jimaging9050102"],"URL":"https:\/\/doi.org\/10.3390\/jimaging9050102","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,16]]}}}