{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T08:15:15Z","timestamp":1778832915649,"version":"3.51.4"},"reference-count":32,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2023,5,31]],"date-time":"2023-05-31T00:00:00Z","timestamp":1685491200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"CNRS"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>This work reports on a terahertz tomography technique using constant velocity flying spot scanning as illumination. This technique is essentially based on the combination of a hyperspectral thermoconverter and an infrared camera used as a sensor, a source of terahertz radiation held on a translation scanner, and a vial of hydroalcoholic gel used as a sample and mounted on a rotating stage for the measurement of its absorbance at several angular positions. From the projections made in 2.5 h and expressed in terms of sinograms, the 3D volume of the absorption coefficient of the vial is reconstructed by a back-projection method based on the inverse Radon transform. This result confirms that this technique is usable on samples of complex and nonaxisymmetric shapes; moreover, it allows 3D qualitative chemical information with a possible phase separation in the terahertz spectral range to be obtained in heterogeneous and complex semitransparent media.<\/jats:p>","DOI":"10.3390\/jimaging9060112","type":"journal-article","created":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T01:40:56Z","timestamp":1685583656000},"page":"112","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Terahertz Constant Velocity Flying Spot for 3D Tomographic Imaging"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0672-1960","authenticated-orcid":false,"given":"Abderezak","family":"Aouali","sequence":"first","affiliation":[{"name":"I2M TREFLE, UMR 5295 CNRS-UB-ENSAM, 351 Cours de la Lib\u00e9ration, 33400 Talence, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4614-1867","authenticated-orcid":false,"given":"St\u00e9phane","family":"Chevalier","sequence":"additional","affiliation":[{"name":"I2M TREFLE, UMR 5295 CNRS-UB-ENSAM, 351 Cours de la Lib\u00e9ration, 33400 Talence, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alain","family":"Sommier","sequence":"additional","affiliation":[{"name":"I2M TREFLE, UMR 5295 CNRS-UB-ENSAM, 351 Cours de la Lib\u00e9ration, 33400 Talence, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christophe","family":"Pradere","sequence":"additional","affiliation":[{"name":"EPSYL-Alcen, Esplanade des Arts et M\u00e9tiers, CEDEX, 33405 Talence, France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,31]]},"reference":[{"key":"ref_1","first-page":"R29","article-title":"X-ray computed tomography","volume":"1","author":"Withers","year":"2021","journal-title":"Nat. Rev. Methods Prim."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/j.tplants.2021.07.010","article-title":"X-ray computed tomography for 3D plant imaging","volume":"26","author":"Piovesan","year":"2021","journal-title":"Trends Plant Sci."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.tcb.2004.11.009","article-title":"New views of cells in 3D: An introduction to electron tomography","volume":"15","author":"McIntosh","year":"2005","journal-title":"Trends Cell Biol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.neuroimage.2005.08.008","article-title":"Cerebral hemodynamics evaluation by near-infrared time-resolved spectroscopy: Correlation with simultaneous positron emission tomography measurements","volume":"29","author":"Ohmae","year":"2006","journal-title":"Neuroimage"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"22310","DOI":"10.1038\/s41598-020-78887-x","article-title":"3D infrared thermospectroscopic imaging","volume":"10","author":"Aouali","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1007\/s10762-014-0057-0","article-title":"Review of terahertz tomography techniques","volume":"35","author":"Guillet","year":"2014","journal-title":"J. Infrared Millim. Terahertz Waves"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1098\/rsta.2003.1321","article-title":"Applications of terahertz spectroscopy to pharmaceutical sciences","volume":"362","author":"Taday","year":"2004","journal-title":"Philos. Trans. R. Soc. Lond. Ser. A Math. Phys. Eng. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1117\/12.525466","article-title":"Through container THz sensing: Applications for explosives screening","volume":"Volume 5354","author":"Cook","year":"2004","journal-title":"Proceedings of the Terahertz and Gigahertz Electronics and Photonics III"},{"key":"ref_9","first-page":"27","article-title":"Terahertz radiation: Applications and sources","volume":"9","author":"Mueller","year":"2003","journal-title":"Ind. Phys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"S266","DOI":"10.1088\/0268-1242\/20\/7\/018","article-title":"THz imaging and sensing for security applications\u2014Explosives, weapons and drugs","volume":"20","author":"Federici","year":"2005","journal-title":"Semicond. Sci. Technol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1088\/0034-4885\/70\/8\/R02","article-title":"Imaging with terahertz radiation","volume":"70","author":"Chan","year":"2007","journal-title":"Rep. Prog. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2549","DOI":"10.1364\/OE.11.002549","article-title":"Non-destructive terahertz imaging of illicit drugs using spectral fingerprints","volume":"11","author":"Kawase","year":"2003","journal-title":"Opt. Express"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"White, J., and Zimdars, D. (2007, January 6\u201311). Time domain terahertz non destructive evaluation of water intrusion in composites and corrosion under insulation. Proceedings of the 2007 Conference on Lasers and Electro-Optics (CLEO), Baltimore, MD, USA.","DOI":"10.1109\/CLEO.2007.4453590"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"031208","DOI":"10.1117\/1.OE.53.3.031208","article-title":"Aeronautics composite material inspection with a terahertz time-domain spectroscopy system","volume":"53","author":"Ospald","year":"2013","journal-title":"Opt. Eng."},{"key":"ref_15","unstructured":"Beckmann, J., Richter, H., Zscherpel, U., Ewert, U., Weinzierl, J., Schmidt, L.P., Rutz, F., Koch, M., H\u00fcbers, H.W., and Richter, H. (2006, January 25\u201329). Imaging Capability of Terahertz and Millimeter-Wave Instrumentations for NDT of Polymer Materials. Proceedings of the 9th European Conference on NDT, Berlin, Germany."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/S0009-2614(00)00227-X","article-title":"Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz","volume":"320","author":"Markelz","year":"2000","journal-title":"Chem. Phys. Lett."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"R301","DOI":"10.1088\/0022-3727\/39\/17\/R01","article-title":"Biomedical applications of terahertz technology","volume":"39","author":"Pickwell","year":"2006","journal-title":"J. Phys. Appl. Phys."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1098\/rsta.2003.1317","article-title":"Three-dimensional terahertz wave imaging","volume":"362","author":"Zhang","year":"2004","journal-title":"Philos. Trans. R. Soc. Lond. Ser. A Math. Phys. Eng. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"B1","DOI":"10.1364\/AO.440847","article-title":"3D image reconstruction of terahertz computed tomography at sparse angles by total variation minimization","volume":"61","author":"Wang","year":"2022","journal-title":"Appl. Opt."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1109\/TTHZ.2016.2519263","article-title":"Advanced processing sequence for 3-D THz imaging","volume":"6","author":"Balacey","year":"2016","journal-title":"IEEE Trans. Terahertz Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Yim, J.H., Kim, S.y., Kim, Y., Cho, S., Kim, J., and Ahn, Y.H. (2021). Rapid 3D-imaging of semiconductor chips using THz time-of-flight technique. Appl. Sci., 11.","DOI":"10.3390\/app11114770"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"374001","DOI":"10.1088\/0022-3727\/47\/37\/374001","article-title":"A review of terahertz sources","volume":"47","author":"Lewis","year":"2014","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"433001","DOI":"10.1088\/1361-6463\/ab31d5","article-title":"A review of terahertz detectors","volume":"52","author":"Lewis","year":"2019","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"346","DOI":"10.2478\/s11772-011-0033-3","article-title":"Terahertz detectors and focal plane arrays","volume":"19","author":"Rogalski","year":"2011","journal-title":"Opto-Electron. Rev."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"17915","DOI":"10.1364\/OE.22.017915","article-title":"Highly precise and accurate terahertz polarization measurements based on electro-optic sampling with polarization modulation of probe pulses","volume":"22","author":"Nemoto","year":"2014","journal-title":"Opt. Express"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7995","DOI":"10.1364\/AO.432479","article-title":"Ultra-broadband contactless imaging power meter","volume":"60","author":"Aouali","year":"2021","journal-title":"Appl. Opt."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1007\/s10762-015-0241-x","article-title":"Broadband Sub-terahertz Camera Based on Photothermal Conversion and IR Thermography","volume":"37","author":"Romano","year":"2016","journal-title":"J. Infrared Millim. Terahertz Waves"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1146\/annurev-anchem-071114-040435","article-title":"Infrared imaging and spectroscopy beyond the diffraction limit","volume":"8","author":"Centrone","year":"2015","journal-title":"Annu. Rev. Anal. Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"047006","DOI":"10.1117\/1.3570648","article-title":"Development of a compact terahertz time-domain spectrometer for the measurement of the optical properties of biological tissues","volume":"16","author":"Wilmink","year":"2011","journal-title":"J. Biomed. Opt."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Settles, G.S. (2001). Schlieren and Shadowgraph Techniques: Visualizing Phenomena in Transparent Media, Springer Science & Business Media.","DOI":"10.1007\/978-3-642-56640-0"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s00348-008-0526-0","article-title":"On the experimental investigation on primary atomization of liquid streams","volume":"45","author":"Dumouchel","year":"2008","journal-title":"Exp. Fluids"},{"key":"ref_32","first-page":"1343","article-title":"Analytic and iterative reconstruction algorithms in SPECT","volume":"43","author":"Bruyant","year":"2002","journal-title":"J. Nucl. Med."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/6\/112\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:46:04Z","timestamp":1760125564000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/6\/112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,31]]},"references-count":32,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["jimaging9060112"],"URL":"https:\/\/doi.org\/10.3390\/jimaging9060112","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,31]]}}}