{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T11:06:05Z","timestamp":1785236765795,"version":"3.55.0"},"reference-count":21,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2023,8,4]],"date-time":"2023-08-04T00:00:00Z","timestamp":1691107200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"German Research Council (DFG)","doi-asserted-by":"publisher","award":["HE 7079\/4-1"],"award-info":[{"award-number":["HE 7079\/4-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25\u00b0 as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30\u00b0 tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.<\/jats:p>","DOI":"10.3390\/jimaging9080157","type":"journal-article","created":{"date-parts":[[2023,8,5]],"date-time":"2023-08-05T10:21:39Z","timestamp":1691230899000},"page":"157","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Target Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5798-8895","authenticated-orcid":false,"given":"Jonas","family":"Fell","sequence":"first","affiliation":[{"name":"Lightweight Systems, Department of Materials Science, Campus E3 1, Saarland University, 66123 Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Wetzler","sequence":"additional","affiliation":[{"name":"Lightweight Systems, Department of Materials Science, Campus E3 1, Saarland University, 66123 Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Maisl","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Nondestructive Testing IZFP, Campus E3 1, 66123 Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3471-1516","authenticated-orcid":false,"given":"Hans-Georg","family":"Herrmann","sequence":"additional","affiliation":[{"name":"Lightweight Systems, Department of Materials Science, Campus E3 1, Saarland University, 66123 Saarbr\u00fccken, Germany"},{"name":"Fraunhofer Institute for Nondestructive Testing IZFP, Campus E3 1, 66123 Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,8,4]]},"reference":[{"key":"ref_1","unstructured":"Lutter, F., Dremel, K., Engel, J., Althoff, D., Zabler, S., Westphal, N., and Hanke, R. (2019, January 2\u20134). XRM-II nanoCT\u2013SEM based computed tomography. Proceedings of the International Symposium on Digital Industrial Radiology and Computed Tomography, F\u00fcrth, Germany."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.nimb.2021.05.006","article-title":"Combining X-ray Nano Tomography with focused ion beam serial section imaging\u2014Application of correlative tomography to integrated circuits","volume":"500","author":"Lutter","year":"2021","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. At."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Engstler, M., Fell, J., Lutter, F., Maisl, M., Herrmann, H.G., and M\u00fccklich, F. (2020, January 4\u20137). Correlative Tomography\u2013Combining X-ray Nanotomography and FIB\/SEM Serial Sectioning to analyze Al-Si cast alloys. Proceedings of the 10th International Conference on Industrial Computed Tomography, Wels, Austria.","DOI":"10.58286\/25100"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1017\/S1431927622012405","article-title":"A FIB-SEM Based Correlative Methodology for X-Ray Nanotomography and Secondary Ion Mass Spectrometry: An Application Example in Lithium Batteries Research","volume":"28","author":"Cressa","year":"2022","journal-title":"Microsc. Microanal."},{"key":"ref_5","first-page":"100009","article-title":"Three-dimensional imaging of microstructural evolution in SEM-based nano-CT","volume":"2","author":"Fell","year":"2023","journal-title":"Tomogr. Mater. Struct."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jvolgeores.2014.11.016","article-title":"High-resolution 3D analyses of the shape and internal constituents of small volcanic ash particles: The contribution of SEM micro-computed tomography (SEM micro-CT)","volume":"293","author":"Vonlanthen","year":"2015","journal-title":"J. Volcanol. Geotherm. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1046\/j.1365-2818.2002.01046.x","article-title":"Quantitative X-ray projection microscopy: Phase-contrast and multi-spectral imaging","volume":"207","author":"Mayo","year":"2002","journal-title":"J. Microsc."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/j.1365-2818.2007.01857.x","article-title":"Software image alignment for X-ray microtomography with submicrometre resolution using a SEM-based X-ray microscope","volume":"228","author":"Mayo","year":"2007","journal-title":"J. Microsc."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1154\/1.3416936","article-title":"Towards sub-100-nm X-ray microscopy for tomographic applications","volume":"25","author":"Bruyndonckx","year":"2010","journal-title":"Powder Diffr."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"063706","DOI":"10.1063\/1.4989406","article-title":"Developments on a SEM-based X-ray tomography system: Stabilization scheme and performance evaluation","volume":"88","author":"Bleuet","year":"2017","journal-title":"Rev. Sci. Instrum."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Sasov, A., Pauwels, B., Bruyndonckx, P., and Liu, X. (2010, January 15\u201320). New Lens-Free X-ray Source for Laboratory Nano-CT with 50-nm Spatial Resolution. Proceedings of the 10th International Conference on X-ray Microscopy, Chicago, IL, USA.","DOI":"10.1117\/12.860340"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1002\/sca.20000","article-title":"CASINO V2. 42\u2014A fast and easy-to-use modeling tool for scanning electron microscopy and microanalysis users","volume":"29","author":"Drouin","year":"2007","journal-title":"J. Scanning Microsc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1017\/S1431927609990407","article-title":"Spectrum simulation in DTSA-II","volume":"15","author":"Ritchie","year":"2009","journal-title":"Microsc. Microanal."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Reimer, L. (1998). Scanning Electron Microscopy, Springer-Verlag. [2nd ed.].","DOI":"10.1007\/978-3-540-38967-5"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Zhao, W., Liu, J., Niu, G., Ma, Y., and Han, L. (2016, January 26). Research on the electron beam spot detection methods based on SEM. Proceedings of the 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Subnanometer Accuracy Measurement for Synchrotron Optics and X-ray Optics, Suzhou, China.","DOI":"10.1117\/12.2245029"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/S0065-2539(08)60212-7","article-title":"Electron probe microanalysis","volume":"13","author":"Castaing","year":"1960","journal-title":"Adv. Electron. Electron Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1002\/pssa.2210900232","article-title":"Maximum depth of characteristic X-ray generation","volume":"90","author":"Gaber","year":"1985","journal-title":"Phys. Status Solidi"},{"key":"ref_18","unstructured":"Berger, M.J., Hubbell, J.H., Seltzer, S.M., Chang, J., Coursey, J.S., Sukumar, R., Zucker, D.S., and Olsen, K. (2023, June 14). XCOM: Photon Cross Section Database (Version 1.5), Available online: http:\/\/physics.nist.gov\/xcom."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"227","DOI":"10.2334\/josnusd.54.227","article-title":"Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines","volume":"54","author":"Bechara","year":"2012","journal-title":"J. Oral Sci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1002\/sca.21179","article-title":"The contrast-to-noise ratio for image quality evaluation in scanning electron microscopy","volume":"37","author":"Timischl","year":"2015","journal-title":"Scanning"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/8\/157\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:26:08Z","timestamp":1760127968000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/8\/157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,4]]},"references-count":21,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2023,8]]}},"alternative-id":["jimaging9080157"],"URL":"https:\/\/doi.org\/10.3390\/jimaging9080157","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,4]]}}}