{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,15]],"date-time":"2025-11-15T04:05:09Z","timestamp":1763179509473,"version":"build-2065373602"},"reference-count":84,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T00:00:00Z","timestamp":1693440000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Promedica foundation"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>In clinical practice, image-based postoperative evaluation is still performed without state-of-the-art computer methods, as these are not sufficiently automated. In this study we propose a fully automatic 3D postoperative outcome quantification method for the relevant steps of orthopaedic interventions on the example of Periacetabular Osteotomy of Ganz (PAO). A typical orthopaedic intervention involves cutting bone, anatomy manipulation and repositioning as well as implant placement. Our method includes a segmentation based deep learning approach for detection and quantification of the cuts. Furthermore, anatomy repositioning was quantified through a multi-step registration method, which entailed a coarse alignment of the pre- and postoperative CT images followed by a fine fragment alignment of the repositioned anatomy. Implant (i.e., screw) position was identified by 3D Hough transform for line detection combined with fast voxel traversal based on ray tracing. The feasibility of our approach was investigated on 27 interventions and compared against manually performed 3D outcome evaluations. The results show that our method can accurately assess the quality and accuracy of the surgery. Our evaluation of the fragment repositioning showed a cumulative error for the coarse and fine alignment of 2.1 mm. Our evaluation of screw placement accuracy resulted in a distance error of 1.32 mm for screw head location and an angular deviation of 1.1\u00b0 for screw axis. As a next step we will explore generalisation capabilities by applying the method to different interventions.<\/jats:p>","DOI":"10.3390\/jimaging9090180","type":"journal-article","created":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T11:33:25Z","timestamp":1693481605000},"page":"180","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Automatic 3D Postoperative Evaluation of Complex Orthopaedic Interventions"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2277-2808","authenticated-orcid":false,"given":"Jo\u00eblle","family":"Ackermann","sequence":"first","affiliation":[{"name":"Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"},{"name":"Laboratory for Orthopaedic Biomechanics, ETH Zurich, 8093 Zurich, Switzerland"}]},{"given":"Armando","family":"Hoch","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"}]},{"given":"Jess Gerrit","family":"Snedeker","sequence":"additional","affiliation":[{"name":"Laboratory for Orthopaedic Biomechanics, ETH Zurich, 8093 Zurich, Switzerland"},{"name":"Department of Orthopedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"}]},{"given":"Patrick Oliver","family":"Zingg","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2572-1798","authenticated-orcid":false,"given":"Hooman","family":"Esfandiari","sequence":"additional","affiliation":[{"name":"Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"}]},{"given":"Philipp","family":"F\u00fcrnstahl","sequence":"additional","affiliation":[{"name":"Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland"}]}],"member":"1968","published-online":{"date-parts":[[2023,8,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1146\/annurev.bioeng.2.1.315","article-title":"Current methods in medical image segmentation","volume":"2","author":"Pham","year":"2000","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_2","first-page":"3","article-title":"Automated medical image segmentation techniques","volume":"35","author":"Sharma","year":"2010","journal-title":"J. Med. Phys.\/Assoc. Med. Phys. India"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1111\/os.12323","article-title":"Computer-assisted orthopaedic surgery","volume":"9","author":"Hernandez","year":"2017","journal-title":"Orthop. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1186\/s13018-016-0372-3","article-title":"Clinical evaluation of a biomechanical guidance system for periacetabular osteotomy","volume":"11","author":"Murphy","year":"2016","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1109\/MC.2012.75","article-title":"First deployments of augmented reality in operating rooms","volume":"45","author":"Navab","year":"2012","journal-title":"Computer"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1038\/s41698-020-0115-0","article-title":"Accurate surgical navigation with real-time tumor tracking in cancer surgery","volume":"4","author":"Kok","year":"2020","journal-title":"NPJ Precis. Oncol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1007\/s11548-019-01973-7","article-title":"Pedicle screw navigation using surface digitization on the Microsoft HoloLens","volume":"14","author":"Liebmann","year":"2019","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Ackermann, J., Liebmann, F., Hoch, A., Snedeker, J.G., Farshad, M., Rahm, S., Zingg, P.O., and F\u00fcrnstahl, P. (2021). Augmented reality based surgical navigation of complex pelvic osteotomies\u2014A feasibility study on cadavers. Appl. Sci., 11.","DOI":"10.3390\/app11031228"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Vlachopoulos, L., Schweizer, A., Graf, M., Nagy, L., and F\u00fcrnstahl, P. (2015). Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides. BMC Musculoskelet. Disord., 16.","DOI":"10.1186\/s12891-015-0793-x"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1007\/s00776-010-1520-y","article-title":"Computed tomography-based navigation for curved periacetabular osteotomy","volume":"15","author":"Akiyama","year":"2010","journal-title":"J. Orthop. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1080\/17453670610012656","article-title":"Image-guided periacetabular osteotomy: Computer-assisted navigation compared with the conventional technique: A randomized study of 36 patients followed for 2 years","volume":"77","author":"Hsieh","year":"2006","journal-title":"Acta Orthop."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/00003086-199809000-00012","article-title":"Computer assistance for pelvic osteotomies","volume":"354","author":"Langlotz","year":"1998","journal-title":"Clin. Orthop. Relat. Res. (1976\u20132007)"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Jecklin, S., Jancik, C., Farshad, M., F\u00fcrnstahl, P., and Esfandiari, H. (2022). X23D\u2014Intraoperative 3D Lumbar Spine Shape Reconstruction Based on Sparse Multi-View X-ray Data. J. Imaging, 8.","DOI":"10.3390\/jimaging8100271"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"317","DOI":"10.3109\/10929089709149831","article-title":"The first twelve cases of computer assisted periacetabular osteotomy","volume":"2","author":"Langlotz","year":"1997","journal-title":"Comput. Aided Surg. Off. J. Int. Soc. Comput. Aided Surg. (ISCAS)"},{"key":"ref_15","unstructured":"Kulyk, P., Vlachopoulos, L., F\u00fcrnstahl, P., and Zheng, G. (2018, January 16). Fully automatic planning of total shoulder arthroplasty without segmentation: A deep learning based approach. Proceedings of the Computational Methods and Clinical Applications in Musculoskeletal Imaging: 6th International Workshop, MSKI 2018, Held in Conjunction with MICCAI 2018, Granada, Spain. Revised Selected Papers 6."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ackermann, J., Wieland, M., Hoch, A., Ganz, R., Snedeker, J.G., Oswald, M.R., Pollefeys, M., Zingg, P.O., Esfandiari, H., and F\u00fcrnstahl, P. (October, January 27). A new approach to orthopedic surgery planning using deep reinforcement learning and simulation. Proceedings of the Medical Image Computing and Computer Assisted Intervention\u2013MICCAI 2021: 24th International Conference, Strasbourg, France. Proceedings, Part IV 24.","DOI":"10.1007\/978-3-030-87202-1_52"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2325967121S00026","DOI":"10.1177\/2325967121S00026","article-title":"Preoperative 3D modeling and printing for guiding periacetabular osteotomy","volume":"9","author":"Shelton","year":"2021","journal-title":"Orthop. J. Sport. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.jcot.2018.07.006","article-title":"Publication trends and knowledge mapping in 3D printing in orthopaedics","volume":"9","author":"Vaishya","year":"2018","journal-title":"J. Clin. Orthop. Trauma"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1243\/09544119JEIM276","article-title":"Computer-assisted single-or double-cut oblique osteotomies for the correction of lower limb deformities","volume":"221","author":"Belei","year":"2007","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Carrillo, F., Vlachopoulos, L., Schweizer, A., Nagy, L., Snedeker, J., and F\u00fcrnstahl, P. (2017, January 11\u201313). A time saver: Optimization approach for the fully automatic 3D planning of forearm osteotomies. Proceedings of the Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI 2017: 20th International Conference, Quebec City, QC, Canada. Proceedings, Part II 20.","DOI":"10.1007\/978-3-319-66185-8_55"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"345","DOI":"10.3109\/10929080500389951","article-title":"Computer-assisted optimization of correction osteotomies on lower extremities","volume":"10","author":"Schkommodau","year":"2005","journal-title":"Comput. Aided Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.media.2016.02.008","article-title":"Regression forest-based automatic estimation of the articular margin plane for shoulder prosthesis planning","volume":"31","author":"Tschannen","year":"2016","journal-title":"Med. Image Anal."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Hoch, A., Grossenbacher, G., Jungwirth-Weinberger, A., G\u00f6tschi, T., F\u00fcrnstahl, P., and Zingg, P.O. (2022). The periacetabular osteotomy: Angulation of the supraacetabular osteotomy for quantification of correction. Hip Int., 11207000221103079.","DOI":"10.1177\/11207000221103079"},{"key":"ref_24","first-page":"26","article-title":"A New Periacetabular Osteotomy for the Treatment of Hip Dysplasias Technique and Preliminary Results","volume":"232","author":"Ganz","year":"1988","journal-title":"Clin. Orthop. Relat. Res. (1976\u20132007)"},{"key":"ref_25","unstructured":"T\u00f6nnis, D. (2012). Congenital Dysplasia and Dislocation of the Hip in Children and Adults, Springer Science & Business Media."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1007\/s11999-014-4038-3","article-title":"What are the radiographic reference values for acetabular under-and overcoverage?","volume":"473","author":"Tannast","year":"2015","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Ibrahim, M.M., and Smit, K. (2020). Anatomical description and classification of hip dysplasia. Hip Dysplasia Underst. Treat. Instab. Nativ. Hip, 23\u201337.","DOI":"10.1007\/978-3-030-33358-4_3"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jhsa.2015.10.009","article-title":"Computer-assisted 3-dimensional reconstructions of scaphoid fractures and nonunions with and without the use of patient-specific guides: Early clinical outcomes and postoperative assessments of reconstruction accuracy","volume":"41","author":"Schweizer","year":"2016","journal-title":"J. Hand Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1177\/1558944717726135","article-title":"Corrective osteotomies of phalangeal and metacarpal malunions using patient-specific guides: CT-based evaluation of the reduction accuracy","volume":"13","author":"Hirsiger","year":"2018","journal-title":"Hand"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/j.jhsa.2020.05.023","article-title":"Accuracy and early clinical outcome after 3-dimensional correction of distal radius intra-articular malunions using patient-specific instruments","volume":"45","author":"Roner","year":"2020","journal-title":"J. Hand Surg."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1031.e1","DOI":"10.1016\/j.jhsa.2017.07.002","article-title":"Accuracy and early clinical outcome of 3-dimensional planned and guided single-cut osteotomies of malunited forearm bones","volume":"42","author":"Roner","year":"2017","journal-title":"J. Hand Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"e150","DOI":"10.2106\/JBJS.K.00829","article-title":"Computer-assisted corrective osteotomy for malunited diaphyseal forearm fractures","volume":"94","author":"Miyake","year":"2012","journal-title":"JBJS"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1016\/j.jse.2017.02.011","article-title":"Computer-assisted planning and patient-specific guides for the treatment of midshaft clavicle malunions","volume":"26","author":"Vlachopoulos","year":"2017","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1016\/j.jse.2016.04.038","article-title":"Three-dimensional corrective osteotomies of complex malunited humeral fractures using patient-specific guides","volume":"25","author":"Vlachopoulos","year":"2016","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"e270","DOI":"10.1097\/BOT.0000000000000301","article-title":"Complex osteotomies of tibial plateau malunions using computer-assisted planning and patient-specific surgical guides","volume":"29","author":"Vlachopoulos","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/s40634-020-00224-y","article-title":"Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy","volume":"7","author":"Fucentese","year":"2020","journal-title":"J. Exp. Orthop."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1302\/0301-620X.95B11.32950","article-title":"Virtual 3D planning and patient specific surgical guides for osteotomies around the knee: A feasibility and proof-of-concept study","volume":"95","author":"Victor","year":"2013","journal-title":"Bone Jt. J."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.otsr.2016.11.020","article-title":"Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study","volume":"103","author":"Munier","year":"2017","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2757","DOI":"10.1007\/s00264-019-04372-4","article-title":"Patient-specific cutting guides for open-wedge high tibial osteotomy: Safety and accuracy analysis of a hundred patients continuous cohort","volume":"43","author":"Chaouche","year":"2019","journal-title":"Int. Orthop."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Vieh\u00f6fer, A.F., Wirth, S.H., Zimmermann, S.M., Jaberg, L., Dennler, C., F\u00fcrnstahl, P., and Farshad, M. (2020). Augmented reality guided osteotomy in hallux Valgus correction. BMC Musculoskelet. Disord., 21.","DOI":"10.1186\/s12891-020-03373-4"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1053\/j.jfas.2017.05.025","article-title":"Three-dimensional correction of complex ankle deformities with computer-assisted planning and patient-specific surgical guides","volume":"56","author":"Weigelt","year":"2017","journal-title":"J. Foot Ankle Surg."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2473011418S00518","DOI":"10.1177\/2473011418S00518","article-title":"Augmented Reality Guided Osteotomy in Hallux Valgus Surgery","volume":"3","author":"Wirth","year":"2018","journal-title":"Foot Ankle Orthop."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"52","DOI":"10.3109\/10929088.2015.1076047","article-title":"Effects of coordinate-system construction methods on postoperative computed tomography evaluation of implant orientation after total hip arthroplasty","volume":"20","author":"Kyo","year":"2015","journal-title":"Comput. Aided Surg."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Gubian, A., Kausch, L., Neumann, J.O., Kiening, K., Ishak, B., Maier-Hein, K., Unterberg, A., and Scherer, M. (2022). CT-Navigated Spinal Instrumentations\u2013Three-Dimensional Evaluation of Screw Placement Accuracy in Relation to a Screw Trajectory Plan. Medicina, 58.","DOI":"10.3390\/medicina58091200"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"818","DOI":"10.20965\/jaciii.2013.p0818","article-title":"An automatic three-dimensional evaluation of screw placement after anterior cruciate ligament reconstruction using mdct images","volume":"17","author":"Uozumi","year":"2013","journal-title":"J. Adv. Comput. Intell. Intell. Inform."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1037\/h0071325","article-title":"Analysis of a complex of statistical variables into principal components","volume":"24","author":"Hotelling","year":"1933","journal-title":"J. Educ. Psychol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1007\/s11548-018-1776-9","article-title":"A deep learning framework for segmentation and pose estimation of pedicle screw implants based on C-arm fluoroscopy","volume":"13","author":"Esfandiari","year":"2018","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"19061","DOI":"10.1007\/s00521-022-07510-z","article-title":"Deep learning-based localization and segmentation of wrist fractures on X-ray radiographs","volume":"34","author":"Joshi","year":"2022","journal-title":"Neural Comput. Appl."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"103345","DOI":"10.1016\/j.cviu.2021.103345","article-title":"Automatic detection and localization of thighbone fractures in X-ray based on improved deep learning method","volume":"216","author":"Guan","year":"2022","journal-title":"Comput. Vis. Image Underst."},{"key":"ref_50","unstructured":"Wei, J., Yao, J., Zhanga, G., Guan, B., Zhang, Y., and Wang, S. (2022). Semi-supervised object detection based on single-stage detector for thighbone fracture localization. arXiv."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.diii.2021.10.007","article-title":"External validation of a commercially available deep learning algorithm for fracture detection in children","volume":"103","author":"Dupuis","year":"2022","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1007\/s00330-022-09205-4","article-title":"Musculoskeletal radiologist-level performance by using deep learning for detection of scaphoid fractures on conventional multi-view radiographs of hand and wrist","volume":"33","author":"Hendrix","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"237.e1","DOI":"10.1016\/j.crad.2019.10.022","article-title":"Detection and localisation of hip fractures on anteroposterior radiographs with artificial intelligence: Proof of concept","volume":"75","author":"Yu","year":"2020","journal-title":"Clin. Radiol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"108925","DOI":"10.1016\/j.ejrad.2020.108925","article-title":"Detection and localization of distal radius fractures: Deep learning system versus radiologists","volume":"126","author":"Becker","year":"2020","journal-title":"Eur. J. Radiol."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"2437","DOI":"10.1097\/BRS.0b013e3181b2eb69","article-title":"Development of a clinical workflow tool to enhance the detection of vertebral fractures: Accuracy and precision evaluation","volume":"34","author":"Brett","year":"2009","journal-title":"Spine"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1080\/17453674.2017.1344459","article-title":"Artificial intelligence for analyzing orthopedic trauma radiographs: Deep learning algorithms\u2014Are they on par with humans for diagnosing fractures?","volume":"88","author":"Olczak","year":"2017","journal-title":"Acta Orthop."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1080\/17453674.2018.1453714","article-title":"Automated detection and classification of the proximal humerus fracture by using deep learning algorithm","volume":"89","author":"Chung","year":"2018","journal-title":"Acta Orthop."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/j.crad.2017.11.015","article-title":"Artificial intelligence in fracture detection: Transfer learning from deep convolutional neural networks","volume":"73","author":"Kim","year":"2018","journal-title":"Clin. Radiol."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"11591","DOI":"10.1073\/pnas.1806905115","article-title":"Deep neural network improves fracture detection by clinicians","volume":"115","author":"Lindsey","year":"2018","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/1754-9485.12828","article-title":"Computer vs. human: Deep learning versus perceptual training for the detection of neck of femur fractures","volume":"63","author":"Adams","year":"2019","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00256-018-3016-3","article-title":"Detecting intertrochanteric hip fractures with orthopedist-level accuracy using a deep convolutional neural network","volume":"48","author":"Urakawa","year":"2019","journal-title":"Skelet. Radiol."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.compbiomed.2018.05.011","article-title":"Deep neural networks for automatic detection of osteoporotic vertebral fractures on CT scans","volume":"98","author":"Tomita","year":"2018","journal-title":"Comput. Biol. Med."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1002\/jbmr.4146","article-title":"Clinical utility of computer-aided diagnosis of vertebral fractures from computed tomography images","volume":"35","author":"Kolanu","year":"2020","journal-title":"J. Bone Miner. Res."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"3815","DOI":"10.1007\/s00330-020-07418-z","article-title":"Automatic detection and classification of rib fractures based on patients\u2019 CT images and clinical information via convolutional neural network","volume":"31","author":"Zhou","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"3434","DOI":"10.1038\/s41598-023-30640-w","article-title":"Maxillofacial fracture detection and classification in computed tomography images using convolutional neural network-based models","volume":"13","author":"Warin","year":"2023","journal-title":"Sci. Rep."},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"He, K., Gkioxari, G., Doll\u00e1r, P., and Girshick, R. (2017, January 22\u201329). Mask r-cnn. Proceedings of the IEEE International Conference on Computer Vision, Venice, Italy.","DOI":"10.1109\/ICCV.2017.322"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1007\/s00256-012-1458-6","article-title":"Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements","volume":"42","author":"Lewis","year":"2013","journal-title":"Skelet. Radiol."},{"key":"ref_68","first-page":"586","article-title":"A Method for Registration of 3-D Shapes","volume":"1611","author":"BESL","year":"1992","journal-title":"Trans. PAMI"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"184","DOI":"10.5201\/ipol.2017.208","article-title":"Iterative Hough transform for line detection in 3D point clouds","volume":"7","author":"Dalitz","year":"2017","journal-title":"Image Process. Line"},{"key":"ref_70","first-page":"3","article-title":"A fast voxel traversal algorithm for ray tracing","volume":"87","author":"Amanatides","year":"1987","journal-title":"Eurographics"},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"\u00c7i\u00e7ek, \u00d6., Abdulkadir, A., Lienkamp, S.S., Brox, T., and Ronneberger, O. (2016, January 17\u201321). 3D U-Net: Learning dense volumetric segmentation from sparse annotation. Proceedings of the Medical Image Computing and Computer-Assisted Intervention\u2013MICCAI 2016: 19th International Conference, Athens, Greece. Proceedings, Part II 19.","DOI":"10.1007\/978-3-319-46723-8_49"},{"key":"ref_72","unstructured":"Kingma, D.P., and Ba, J. (2014). Adam: A method for stochastic optimization. arXiv."},{"key":"ref_73","doi-asserted-by":"crossref","unstructured":"Milletari, F., Navab, N., and Ahmadi, S. (2016, January 25\u201328). V-net: Fully convolutional neural networks for volumetric medical image segmentation. Proceedings of the 2016 Fourth International Conference on 3D Vision (3DV), Stanford, CA, USA.","DOI":"10.1109\/3DV.2016.79"},{"key":"ref_74","unstructured":"Zhang, Z., and Sabuncu, M. (2018). Generalized cross entropy loss for training deep neural networks with noisy labels. Adv. Neural Inf. Process. Syst., 31."},{"key":"ref_75","unstructured":"Yoo, T.S., Ackerman, M.J., Lorensen, W.E., Schroeder, W., Chalana, V., Aylward, S., Metaxas, D., and Whitaker, R. (2002). Medicine Meets Virtual Reality 02\/10, IOS Press."},{"key":"ref_76","unstructured":"Johnson, H.J., McCormick, M., and Ibanez, L. (2015). The ITK Software Guide: Design and Functionality, Kitware Inc."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"12","DOI":"10.15623\/ijret.2014.0317003","article-title":"Application of normalized cross correlation to image registration","volume":"3","author":"Rao","year":"2014","journal-title":"Int. J. Res. Eng. Technol."},{"key":"ref_78","unstructured":"Mambo, S. (2018). Optimisation and Performance Evaluation in Image Registration Technique. [Ph.D. Thesis, Universit\u00e9 Paris-Est, Tshwane University of Technology]."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1016\/j.patcog.2014.08.027","article-title":"A survey of Hough Transform","volume":"48","author":"Mukhopadhyay","year":"2015","journal-title":"Pattern Recognit."},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Burger, W., and Burge, M. (2010). Principles of Digital Image Processing: Core Algorithms, Springer.","DOI":"10.1007\/978-1-84800-195-4"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1109\/TMI.2011.2158349","article-title":"Evaluation of registration methods on thoracic CT: The EMPIRE10 challenge","volume":"30","author":"Murphy","year":"2011","journal-title":"IEEE Trans. Med Imaging"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"519","DOI":"10.3171\/2020.3.SPINE20208","article-title":"Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory","volume":"33","author":"Jiang","year":"2020","journal-title":"J. Neurosurg. Spine"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"6793","DOI":"10.1007\/s00330-021-07824-x","article-title":"Pelvic bone CT: Can tin-filtered ultra-low-dose CT and virtual radiographs be used as alternative for standard CT and digital radiographs?","volume":"31","author":"Stern","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_84","doi-asserted-by":"crossref","unstructured":"Kasten, Y., Doktofsky, D., and Kovler, I. (2020, January 8). End-to-end convolutional neural network for 3D reconstruction of knee bones from bi-planar X-ray images. Proceedings of the Machine Learning for Medical Image Reconstruction: Third International Workshop, MLMIR 2020, Held in Conjunction with MICCAI 2020, Lima, Peru. Proceedings 3.","DOI":"10.1007\/978-3-030-61598-7_12"}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/9\/180\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:44:11Z","timestamp":1760129051000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/9\/180"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,31]]},"references-count":84,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,9]]}},"alternative-id":["jimaging9090180"],"URL":"https:\/\/doi.org\/10.3390\/jimaging9090180","relation":{},"ISSN":["2313-433X"],"issn-type":[{"type":"electronic","value":"2313-433X"}],"subject":[],"published":{"date-parts":[[2023,8,31]]}}}