{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T18:52:08Z","timestamp":1792003928784,"version":"4.4.0"},"reference-count":28,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:00:00Z","timestamp":1695772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Region Bourgogne Franche Comt\u00e9 and its ISITE-BFC research fund (\u00abInitiatives Science Innovation Territoire Economie en Bourgogne-Franche-Comt\u00e9\u00bb)"},{"name":"SAFRAN Aircraft Engines"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>In the thermography process, accurately determining emissivity is crucial to obtain precise temperature measurements as it enables the conversion of radiometric values to absolute temperatures. However, assessing emissivity is not a straightforward task as it depends on various other parameters. Traditional methods for measuring emissivity often involve costly materials and cannot be carried out simultaneously with infrared image acquisition. This article presents a method for obtaining pixel-wise emissivity using data from a multispectral infrared camera. Consequently, this method allows for direct emissivity measurement during infrared camera acquisition without the need for additional materials or experiments.<\/jats:p>","DOI":"10.3390\/jimaging9100198","type":"journal-article","created":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T03:04:18Z","timestamp":1695783858000},"page":"198","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["In-Situ Pixel-wise Emissivity Measurement Using a Multispectral Infrared Camera"],"prefix":"10.3390","volume":"9","author":[{"given":"Corentin","family":"Poissenot-Arrigoni","sequence":"first","affiliation":[{"name":"Arts et M\u00e9tiers Institute of Technology, LaBoMaP, UBFC, HESAM, F-71250 Cluny, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertrand","family":"Marcon","sequence":"additional","affiliation":[{"name":"Arts et M\u00e9tiers Institute of Technology, LaBoMaP, UBFC, HESAM, F-71250 Cluny, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fr\u00e9d\u00e9ric","family":"Rossi","sequence":"additional","affiliation":[{"name":"Arts et M\u00e9tiers Institute of Technology, LaBoMaP, UBFC, HESAM, F-71250 Cluny, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillaume","family":"Fromentin","sequence":"additional","affiliation":[{"name":"Arts et M\u00e9tiers Institute of Technology, LaBoMaP, UBFC, HESAM, F-71250 Cluny, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,9,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/j.1747-1567.2004.tb00157.x","article-title":"Prediction of Tensile Failure of 316 Stainless Steel Using Infrared Thermography","volume":"28","author":"Venkatraman","year":"2004","journal-title":"Exp. Tech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1007\/s40799-016-0078-9","article-title":"Thermomechanical Fatigue Tests Development and Life Prediction of a Nickel Base Superalloy","volume":"40","year":"2016","journal-title":"Exp. Tech."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s40799-021-00537-2","article-title":"Analysis of Chip Formation and Temperature Measurement in Machining of Titanium Alloy (Ti-6Al-4V)","volume":"47","author":"Palanikumar","year":"2023","journal-title":"Exp. Tech."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s10765-022-03058-1","article-title":"Non-contact Steady-State Thermal Characterization of Lithium-Ion Battery Plates Using Infrared Thermography","volume":"43","author":"Liu","year":"2022","journal-title":"Int. J. Thermophys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s40799-017-0200-7","article-title":"Infrared Techniques for Practical Defect Identification in Bonded Joints in Liquefied Natural Gas Carriers","volume":"42","author":"Tighe","year":"2018","journal-title":"Exp. Tech."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1111\/j.1747-1567.2010.00658.x","article-title":"Defect Detection in Concrete Structures Using Thermal Imaging Techniques","volume":"35","author":"Bhalla","year":"2011","journal-title":"Exp. Tech."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Schager, A., Zauner, G., Mayr, G., and Burgholzer, P. (2020). Extension of the Thermographic Signal Reconstruction Technique for an Automated Segmentation and Depth Estimation of Subsurface Defects. J. Imaging, 6.","DOI":"10.3390\/jimaging6090096"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Mouhoubi, K., Detalle, V., Vallet, J.-M., and Bodnar, J.-L. (2019). Improvement of the Non-Destructive Testing of Heritage Mural Paintings Using Stimulated Infrared Thermography and Frequency Image Processing. J. Imaging, 5.","DOI":"10.3390\/jimaging5090072"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"De Finis, R., Palumbo, D., and Galietti, U. (2016). Mechanical Behaviour of Stainless Steels under Dynamic Loading: An Investigation with Thermal Methods. J. Imaging, 2.","DOI":"10.3390\/jimaging2040032"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s10765-022-03138-2","article-title":"On the Thermal Characterization of Insulating Solids Using Laser-Spot Thermography in a Front Detection Configuration","volume":"44","author":"Bedoya","year":"2023","journal-title":"Int. J. Thermophys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1007\/s10765-022-03109-7","article-title":"Thermophysical Properties Mapping of Composites by Lock-in Thermography: Applications on Carbon Fiber Reinforced Plastics","volume":"43","author":"Alasli","year":"2022","journal-title":"Int. J. Thermophys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/s10765-021-02866-1","article-title":"Temperature Distribution Characteristics of Steel Circular Tube Members under Oil Pool Fire Conditions: Experiment and Numerical Simulation","volume":"42","author":"Wu","year":"2021","journal-title":"Int. J. Thermophys."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"103813","DOI":"10.1016\/j.infrared.2021.103813","article-title":"Analysis of multi-factor on measurement improvement of an infrared imager in low-temperature environments","volume":"116","author":"He","year":"2021","journal-title":"Infrared Phys. Technol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.infrared.2009.07.003","article-title":"A method to retrieve blackbody temperature errors in the two points radiometric calibration","volume":"52","author":"Jeseck","year":"2009","journal-title":"Infrared Phys. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.infrared.2016.11.008","article-title":"Proposition of a compensated pixelwise calibration for photonic infrared cameras and comparison to classic calibration procedures: Case of thermoelastic stress analysis","volume":"80","author":"Doudard","year":"2017","journal-title":"Infrared Phys. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.infrared.2014.05.012","article-title":"Non-uniformity correction of infrared focal plane array in point target surveillance systems","volume":"66","author":"Hu","year":"2014","journal-title":"Infrared Phys. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Monchau, J.-P., and Hameury, J. (2018). Mesure de l\u2019\u00e9missivit\u00e9 thermique. Tech. L\u2019ing\u00e9nieur, 27, (In French).","DOI":"10.51257\/a-v1-r2747"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jallcom.2011.09.097","article-title":"Normal spectral emittance of Inconel 718 aeronautical alloy coated with yttria stabilized zirconia films","volume":"513","author":"Tello","year":"2012","journal-title":"J. Alloys Compd."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.ijheatmasstransfer.2004.10.003","article-title":"Emissivity characteristics of polished aluminum alloy surfaces and assessment of multispectral radiation thermometry (MRT) emissivity models","volume":"48","author":"Wen","year":"2005","journal-title":"Int. J. Heat Mass Transf."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.nucengdes.2015.02.018","article-title":"Total hemispherical emissivity of Inconel 718","volume":"287","author":"Keller","year":"2015","journal-title":"Nucl. Eng. Des."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.jallcom.2009.09.091","article-title":"Emissivity measurements on aeronautical alloys","volume":"489","author":"Esquisabel","year":"2010","journal-title":"J. Alloys Compd."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"584","DOI":"10.2514\/3.23259","article-title":"Pyrometry for turbine blade development","volume":"6","author":"Suarez","year":"1990","journal-title":"J. Propuls. Power"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"105203","DOI":"10.1088\/0957-0233\/26\/10\/105203","article-title":"Analysis and improvement of gas turbine blade temperature measurement error","volume":"26","author":"Gao","year":"2015","journal-title":"Meas. Sci. Technol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1115\/1.1452245","article-title":"Development and Evaluation of a High-Resolution Turbine Pyrometer System","volume":"124","author":"Eggert","year":"2002","journal-title":"J. Turbomach."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"104741","DOI":"10.1016\/j.infrared.2023.104741","article-title":"Fast and easy radiometric calibration method integration time insensitive for infrared thermography","volume":"133","author":"Marcon","year":"2023","journal-title":"Infrared Phys. Technol."},{"key":"ref_26","unstructured":"Monchau, J.-P. (2013). Mesure d\u2019\u00c9missivit\u00e9 pour la Thermographie Infrarouge Appliqu\u00e9e au Diagnostic Quantitatif des Structures. [Ph.D. Thesis, Paris-East Cr\u00e9teil University]. (In French)."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Pajani, D. (2013). Thermographie\u2014Principes et Mesure, Techniques de l\u2019Ingenieur. (In French).","DOI":"10.51257\/a-v2-r2740"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.infrared.2018.09.004","article-title":"Effect of pyrometer type and wavelength selection on temperature measurement errors for turbine blades","volume":"94","author":"Li","year":"2018","journal-title":"Infrared Phys. Technol."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/10\/198\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:59:17Z","timestamp":1760129957000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/9\/10\/198"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,27]]},"references-count":28,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["jimaging9100198"],"URL":"https:\/\/doi.org\/10.3390\/jimaging9100198","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,27]]}}}