{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,5]],"date-time":"2026-07-05T01:10:34Z","timestamp":1783213834669,"version":"3.54.6"},"reference-count":29,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2012,6,15]],"date-time":"2012-06-15T00:00:00Z","timestamp":1339718400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Single-cell studies of phenotypic heterogeneity reveal more information about pathogenic processes than conventional bulk-cell analysis methods. By enabling high-resolution structural and functional imaging, a single-cell three-dimensional (3D) imaging system can be used to study basic biological processes and to diagnose diseases such as cancer at an early stage. One mechanism that such systems apply to accomplish 3D imaging is rotation of a single cell about a fixed axis. However, many cell rotation mechanisms require intricate and tedious microfabrication, or fail to provide a suitable environment for living cells. To address these and related challenges, we applied numerical simulation methods to design new microfluidic chambers capable of generating fluidic microvortices to rotate suspended cells. We then compared several microfluidic chip designs experimentally in terms of: (1) their ability to rotate biological cells in a stable and precise manner; and (2) their suitability, from a geometric standpoint, for microscopic cell imaging. We selected a design that incorporates a trapezoidal side chamber connected to a main flow channel because it provided well-controlled circulation and met imaging requirements. Micro particle-image velocimetry (micro-PIV) was used to provide a detailed characterization of flows in the new design. Simulated and experimental results demonstrate that a trapezoidal side chamber represents a viable option for accomplishing controlled single cell rotation. Further, agreement between experimental and simulated results confirms that numerical simulation is an effective method for chamber design.<\/jats:p>","DOI":"10.3390\/mi3020529","type":"journal-article","created":{"date-parts":[[2012,6,15]],"date-time":"2012-06-15T11:38:02Z","timestamp":1339760282000},"page":"529-541","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Simulation and Experimental Characterization of Microscopically Accessible Hydrodynamic Microvortices"],"prefix":"10.3390","volume":"3","author":[{"given":"Wenjie","family":"Zhang","sequence":"first","affiliation":[{"name":"Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA"},{"name":"School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David H.","family":"Frakes","sequence":"additional","affiliation":[{"name":"School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287, USA"},{"name":"School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haithem","family":"Babiker","sequence":"additional","affiliation":[{"name":"School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shih-hui","family":"Chao","sequence":"additional","affiliation":[{"name":"Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cody","family":"Youngbull","sequence":"additional","affiliation":[{"name":"Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger H.","family":"Johnson","sequence":"additional","affiliation":[{"name":"Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deirdre R.","family":"Meldrum","sequence":"additional","affiliation":[{"name":"Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA"},{"name":"School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2012,6,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1038\/nrmicro1460","article-title":"Microbial cell individuality and the underlying sources of heterogeneity","volume":"4","author":"Avery","year":"2006","journal-title":"Nat. Rev. Microbiol."},{"key":"ref_2","first-page":"15","article-title":"Connections between single-cell biomechanics and human disease states: Gastrointestinal cancer and malaria","volume":"1","author":"Suresh","year":"2005","journal-title":"ActaBiomater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1073\/pnas.0334858100","article-title":"Multiple mutations and cancer","volume":"100","author":"Loeb","year":"2003","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1002\/cyto.a.20997","article-title":"Quantitative characterization of preneoplastic progression using single-cell computed tomography and three-dimensional karyometry","volume":"79A","author":"Nandakumar","year":"2011","journal-title":"Cytometry"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.patcog.2008.06.018","article-title":"Automated cell analysis in 2D and 3D: A comparative study","volume":"42","author":"Meyer","year":"2009","journal-title":"Pattern Recogn."},{"key":"ref_6","first-page":"1","article-title":"Confocal microscopy","volume":"23","author":"Semwogerere","year":"2005","journal-title":"Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"4210","DOI":"10.1364\/OPEX.13.004210","article-title":"Three-dimensional imaging of single isolated cell nuclei using optical projection tomography","volume":"13","author":"Fauver","year":"2005","journal-title":"Opt. Express"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Miao, Q., Rahn, J.R., Tourovskaia, A., Meyer, M.G., Neumann, T., Nelson, A.C., and Seibel, E.J. (2009). Dual-modal three-dimensional imaging of single cells with isometric high resolution using an optical projection tomography microscope. J. Biomed. Opt.","DOI":"10.1117\/1.3275470"},{"key":"ref_9","unstructured":"Arai, F., Kawaji, A., Luangjarmekom, P., Fukuda, T., and Itoigawa, K. (2001, January 21\u201326). Three-dimensional Bio-micromanipulation under the microscope. Proceedings of the 2001 IEEE International Conference on Robotics and Automation, Seoul, Korea."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"8937","DOI":"10.1021\/ac800972t","article-title":"Trapping of bioparticles via microvortices in a microfluidic device for bioassay applications","volume":"80","author":"Lin","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1038\/nrmicro755","article-title":"Life-on-a-chip","volume":"1","author":"Lidstrom","year":"2003","journal-title":"Nat. Rev. Microbiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1039\/B613650H","article-title":"A microfluidic system in combination with optical tweezers for analyzing rapid and reversible cytological alterations in single cells upon environmental changes","volume":"7","author":"Eriksson","year":"2007","journal-title":"Lab Chip"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1128\/MMBR.68.3.538-559.2004","article-title":"Single-cell microbiology: Tools, technologies, and applications","volume":"68","author":"Johnson","year":"2004","journal-title":"Microbiol. Mol. Biol. Rev."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Shelby, J.P., Lim, D.S.W., Kuo, J.S., and Chiu, D.T. (2003). High radial acceleration in microvortices. Nature.","DOI":"10.1038\/425038a"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1039\/b402479f","article-title":"Controlled rotation of biological micro- and nano-particles in microvortices","volume":"4","author":"Shelby","year":"2004","journal-title":"Lab Chip"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1038\/330769a0","article-title":"Optical trapping and manipulation of single cells using infrared-laser beams","volume":"330","author":"Ashkin","year":"1987","journal-title":"Nature"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2787","DOI":"10.1063\/1.1785844","article-title":"Optical trapping","volume":"75","author":"Neuman","year":"2004","journal-title":"Rev. Sci. Instrum."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"5955","DOI":"10.1021\/la8003917","article-title":"Cell culture chip using low-shear mass transport","volume":"24","author":"Liu","year":"2008","journal-title":"Langmuir"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2492","DOI":"10.1021\/ac035531v","article-title":"Direct manipulation and observation of the rotational motion of single optically trapped microparticles and biological cells in microvortices","volume":"76","author":"Shelby","year":"2004","journal-title":"Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Ha, J.B., Bahk, Y.K., Yoon, S.H., Lee, J.H., Jeong, E.H., Yoon, S.Y., Arakawa, T., Ko, J.S., Shin, B.S., Kim, K.C., Boo, J.S., Shoji, S., and Go, J.S. (2007, January 10\u201314). Microfludic centrifuge of nano particles using rotating flow in a microchamber. Proceedings of the Solid-State SensorsActuators and Microsystems ConferenceTRANSDUCERS 2007, Lyon, France.","DOI":"10.1109\/SENSOR.2007.4300283"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1021\/ac026275+","article-title":"Mapping fast flows over micrometer-length scales using flow-tagging velocimetry and single-molecule detection","volume":"75","author":"Shelby","year":"2003","journal-title":"Anal. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1007\/s003480050235","article-title":"A particle image velocimetry system for microfluidics","volume":"25","author":"Santiago","year":"1998","journal-title":"Exp. Fluids"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Raffel, M., Willert, C.E., Wereley, S.T., and Kompenhaus, J. (2007). Particle Image Velocimetry a Practical Guide, Springer. [2nd].","DOI":"10.1007\/978-3-540-72308-0"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s10404-009-0459-9","article-title":"MicroPIV and micromixing study of corona wind induced microcentrifugation flows in a cylindrical cavity","volume":"8","author":"Qin","year":"2009","journal-title":"Microfluid. Nanofluid."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.snb.2009.11.061","article-title":"Three-dimensional spheroid-forming lab-on-a-chip using micro-rotational flow","volume":"147","author":"Ota","year":"2010","journal-title":"Sens. Actuat. B Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1039\/b500972c","article-title":"Geometric effects on fluid mixing in passive grooved micromixers","volume":"5","author":"Yang","year":"2005","journal-title":"Lab Chip"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1039\/B813952K","article-title":"Continuous focusing of microparticles using inertial lift force and vorticity via multi-orifice microfluidic channels","volume":"9","author":"Park","year":"2009","journal-title":"Lab Chip"},{"key":"ref_28","unstructured":"Fox, R.W., Pritchard, P.J., and McDonald, A.T. (2008). Introduction to Fluid Mechanics, Wiley. [7th]."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.2113\/gsecongeo.58.8.1246","article-title":"Principles of geostatistics","volume":"58","author":"Matheron","year":"1963","journal-title":"Econ. Geol."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/3\/2\/529\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:50:49Z","timestamp":1760219449000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/3\/2\/529"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,15]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2012,6]]}},"alternative-id":["mi3020529"],"URL":"https:\/\/doi.org\/10.3390\/mi3020529","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6,15]]}}}