{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T07:42:53Z","timestamp":1768981373361,"version":"3.49.0"},"reference-count":39,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2014,7,3]],"date-time":"2014-07-03T00:00:00Z","timestamp":1404345600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>An ultrasonic transducer is a key component to achieve ultrasonic imaging. This paper designs a new type of Microelectromechanical Systems (MEMS) based capacitive ultrasonic transducer and a linear array based on the transducer. Through directivity analysis, it can be found that its directivity is weak due to the small size of the designed transducer, but the directivity of the designed linear array is very strong. In order to further suppress the sidelobe interference and improve the resolution of the imaging system and imaging quality, the Dolph-Chebyshev weighting method and the Taylor weighting method are used to process \u221240dB sidelobe suppression, and satisfactory results are obtained, which can meet actual requirements.<\/jats:p>","DOI":"10.3390\/mi5030420","type":"journal-article","created":{"date-parts":[[2014,7,3]],"date-time":"2014-07-03T11:13:17Z","timestamp":1404385997000},"page":"420-431","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Design and Performance Analysis of Capacitive Micromachined Ultrasonic Transducer Linear Array"],"prefix":"10.3390","volume":"5","author":[{"given":"Hongliang","family":"Wang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, MOEMS Education Ministry Key Laboratory, Tianjin University, Tianjin 300072, China"},{"name":"National Key Laboratory for Electronic Measurement Technology, Key Laboratory of Instrumentation Science & Dynamic Measurement (North University of China), Ministry of Education, North University of China, Taiyuan 030051, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangjun","family":"Wang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, MOEMS Education Ministry Key Laboratory, Tianjin University, Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changde","family":"He","sequence":"additional","affiliation":[{"name":"National Key Laboratory for Electronic Measurement Technology, Key Laboratory of Instrumentation Science & Dynamic Measurement (North University of China), Ministry of Education, North University of China, Taiyuan 030051, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenyang","family":"Xue","sequence":"additional","affiliation":[{"name":"National Key Laboratory for Electronic Measurement Technology, Key Laboratory of Instrumentation Science & Dynamic Measurement (North University of China), Ministry of Education, North University of China, Taiyuan 030051, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,7,3]]},"reference":[{"key":"ref_1","first-page":"131","article-title":"Application and development of piezoelectric ultrasonic transducers","volume":"27","author":"Jia","year":"2004","journal-title":"Piezoelectrics Acoustooptics"},{"key":"ref_2","first-page":"74","article-title":"PZT thick film and high frequency ultrasonic transducer","volume":"29","author":"Wen","year":"2010","journal-title":"Tech. Acoust."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1109\/JSEN.2007.896562","article-title":"A micromachined piezoelectric ultrasonic transducer operating in d33 mode using square interdigital electrodes","volume":"7","author":"Wang","year":"2007","journal-title":"IEEE Sens. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1109\/TUFFC.2005.1561640","article-title":"Design and analysis of a PZT-based micromachined acoustic transducer with increased sensitivity","volume":"52","author":"Wang","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2276","DOI":"10.1109\/TUFFC.2005.1563270","article-title":"Piezoelectric micromachined transducers based on PZT thin films","volume":"52","author":"Muralt","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1023\/B:JECR.0000034004.99355.8b","article-title":"Micromachined ultrasonic transducers and acoustic transducers based on piezoelectric thin films","volume":"12","author":"Muralt","year":"2004","journal-title":"J. Electroceramics"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2289","DOI":"10.1109\/TUFFC.2005.1563271","article-title":"Fabrication and characterization of piezoelectric micromachined ultrasonic transducers with thick composite PZT films","volume":"52","author":"Wang","year":"2005","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_8","unstructured":"Wang, Z.H., Zhu, W.G., Miao, J.M., Zhu, H., Chao, C., and Tan, O.K. (2005, January 5\u20139). Micromachined Thick Film Piezoelectric Ultrasonic Transducer Array. Proceedings of the 13th Intemational Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea."},{"key":"ref_9","unstructured":"Eccardt, P.C., Niederer, K., Scheiter, T., and Hierold, C. (1996, January 3\u20136). Surface Micromachined Ultrasound Transducers in CMOS Technology. Proceedings of the 1996 IEEE Ultrasonic Symposium, San Antonio, TE, USA."},{"key":"ref_10","unstructured":"Eccardt, P.C., Niederer, K., and Fischer, B. (1997, January 5\u20138). Micromachined Transducers for Ultrasonic Applications. Proceedings of the 1997 IEEE Ultrasonic Symposium, Toronto, Canada."},{"key":"ref_11","unstructured":"Mills, D.M., and Smith, L.S. (2003, January 5\u20138). Real Time in-vivo Imaging with Capacitive Micromachined Ultrasonic Transducer (cMUT) Linear Arrays. Proceedings of the 2003 IEEE Ultrasonic Symposium, Honolulu, HA, USA."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1109\/TUFFC.2002.1049742","article-title":"Capacitive micromachined ultrasonic transducers: Next-generation arrays for acoustic imaging?","volume":"49","author":"Ergun","year":"2002","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1109\/58.677612","article-title":"Surface micromachined capacitive ultrasonic transducers","volume":"45","author":"Ladabaum","year":"1998","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1061\/(ASCE)0893-1321(2003)16:2(76)","article-title":"Capacitive micromachined ultrasonic Transducers: Theory and technology","volume":"16","author":"Ergun","year":"2003","journal-title":"J. Aerosp. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1109\/58.39112","article-title":"A silicon electrostatic ultrasonic transducer","volume":"36","author":"Suzuki","year":"1989","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/58.484456","article-title":"A surface micromachined electrostatic ultrasonic air transducer","volume":"43","author":"Haller","year":"1996","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_17","unstructured":"Hansen, S.T., Mossawir, B.J., Sanli Ergun, A., Degertekin, F., and Khuri-Yakub, B.T. (1999, January 17\u201320). Air-Coupled Nondestructive Evaluation Using Micromachined Ultrasonic Transducers. Proceedings of the 1999 IEEE Ultrasonics Symposium, Lake Tahoe, NV, USA."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/S0041-624X(02)00161-0","article-title":"Medical imaging using capacitive micromachined ultrasonic transducer arrays","volume":"40","author":"Johnson","year":"2002","journal-title":"Ultrason."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Oralkan, O., Ergun, A.S., Cheng, C.H., Johnson, J.A., Karaman, M., Lee, T.H., and Khuri-Yakub, B.T. (2002, January 8\u201311). Volumetric Imaging Using 2D Capacitive Micromachined Ultrasonic Transducer Arrays (CMUTs): Initial results. Proceedings of the 2002 IEEE Ultrasonics Symposium, Munich, Germany.","DOI":"10.1109\/ULTSYM.2002.1192483"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.sna.2007.04.008","article-title":"Integration of trench-isolated through-wafer interconnects with 2D capacitive micromachined ultrasonic transducer arrays","volume":"138","author":"Zhuang","year":"2007","journal-title":"Sens. Actuators A Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1109\/JMEMS.2008.918381","article-title":"Fabrication of flexible transducer arrays with through-wafer electrical interconnects based on trench refilling with PDMS","volume":"17","author":"Zhuang","year":"2008","journal-title":"J. Microelectromech. Syst."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2145","DOI":"10.1109\/TUFFC.2009.1297","article-title":"An integrated circuit with transmit beam forming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging","volume":"56","author":"Wygant","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Choe, J.W., Oralkan, O., Nikoozadeh, A., Bhuyan, A., Lee, B.C., Gence, M., and Khuri-Yakub, B.T. (2011, January 18\u201321). Real-Time Volumetric Imaging System for CMUT Arrays. Proceedings of the 2011 IEEE Ultrasonics Symposium, Orlando, FL, USA.","DOI":"10.1109\/ULTSYM.2011.0261"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Bhuyan, A., Choe, J.W., Lee, B.C., Wygant, I., Nikoozadeh, A., Oralkan, O., and Khuri-Yakub, B.T. (2013, January 17\u201321). 3D Volumetric Ultrasound Imaging with a 32 \u00d7 32 CMUT Array Integrated with Front-End ICs Using Flip-Chip Bonding Technology. Proceedings of the Solid-State Circuits Conference Digest of Technical Papers (ISSCC)2013 IEEE International, San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2013.6487786"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1109\/JSSC.2003.813294","article-title":"A multichannel pipeline analog-to-digital converter for an integrated 3-D ultrasound imaging system","volume":"38","author":"Kaviani","year":"2003","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Wygant, I.O., Karaman, M., Oralkan, \u00d6., and Khuri-Yakub, B.T. (2006, January 11). Beamforming and Hardware Design for a Multichannel Front-End Integrated Circuit for Real-Time 3-D Catheter-Based Ultrasonic Imaging. Proceedings of the SPIE 6147, Medical Imaging 2006: Ultrasonic Imaging and Signal, San Diego, CA, USA.","DOI":"10.1117\/12.673786"},{"key":"ref_27","unstructured":"Oralkan, \u00d6.S., Hansen, T., Bayram, B., Yaralioglu, G.G., Ergun, A.S., and Khuri-Yakub, B.T. (2004, January 24\u201327). High-Frequency CMUT Arrays for High-Resolution Medical Imaging. Proceedings of the 2007 IEEE Ultrasonics Symposium, Montr\u00e9al, Canada."},{"key":"ref_28","unstructured":"Zhuang, X., Wygant, I.O., Lin, D.S., Kupnik, M., Oralkan, \u00d6., and Khuri-Yakub, B.T. (2007, January 28\u201331). Trench-Isolated CMUT Arrays with a Supporting Frame: Characterization and Imaging Results. Proceedings of the 2007 IEEE Ultrasonics Symposium, New York, NY, USA."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1016\/j.mejo.2005.10.012","article-title":"Capacitive micromachined ultrasonic transducer (CMUT) arrays for medical imaging","volume":"37","author":"Caronti","year":"2006","journal-title":"Microelectron. J."},{"key":"ref_30","first-page":"156","article-title":"Structure design and simulation of capacitive microfabricated ultrasonic transducer","volume":"5","author":"Song","year":"2006","journal-title":"Nanotechnol. Precis. Eng."},{"key":"ref_31","first-page":"2297","article-title":"Silicon condenser microphone with round membranes","volume":"12","author":"Tian","year":"2006","journal-title":"Chin. J. Sens. Actuators"},{"key":"ref_32","first-page":"133","article-title":"Analysis of the resonant frequency of capacitive micro-machined ultrasonic transducer (cMUT) with Finite Element Method","volume":"28","author":"Hao","year":"2009","journal-title":"Tech. Acoust."},{"key":"ref_33","first-page":"1653","article-title":"Design of MEMS capacitiVe ultrasonic transducer based on wafer bonding technology","volume":"25","author":"Miao","year":"2012","journal-title":"Chin. J. Sens. Actuators"},{"key":"ref_34","unstructured":"Luan, G.D., Zhang, J.D., and Wang, R.Q. (2005). Piezoelectric Transducer and Transducer Array, Peking University Press. (In Chinese)."},{"key":"ref_35","unstructured":"Kino, G.S. (1987). Acoustic Waves: Devices, Imaging, and Analog Signal Processing, Prentice-Hall."},{"key":"ref_36","unstructured":"Kinsler, L.E., Frey, A.R., Coppens, A.B., and Sanders, J.V. (2000). Fundamentals of Acoustics, Wiley. [4th ed.]."},{"key":"ref_37","unstructured":"Angelsen, B.A.J. (2000). Ultrasound Imaging: Waves, Signals, and Signal Processing, Emantec."},{"key":"ref_38","unstructured":"Du, G.H., Zhu, Z.M., and Gong, X.F. (2012). Acoustics Foundation, Nanjing University Press. [3rd ed.]. (In Chinese)."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Van Trees, H.L. (2002). Optimum Array Processing, Wiley.","DOI":"10.1002\/0471221104"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/5\/3\/420\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:13:16Z","timestamp":1760217196000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/5\/3\/420"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7,3]]},"references-count":39,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2014,9]]}},"alternative-id":["mi5030420"],"URL":"https:\/\/doi.org\/10.3390\/mi5030420","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,7,3]]}}}