{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T14:20:29Z","timestamp":1773843629448,"version":"3.50.1"},"reference-count":25,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2014,9,10]],"date-time":"2014-09-10T00:00:00Z","timestamp":1410307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["25-3580"],"award-info":[{"award-number":["25-3580"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>We propose a single cell extraction chip with an open structure, which utilizes vibration-induced whirling flow and a single cell catcher. By applying a circular vibration to a micropillar array spiral pattern, a whirling flow is induced around the micropillars, and target cells are transported towards the single cell catcher placed at the center of the spiral. The single cell catcher is composed of a single-cell-sized hole pattern of thermo-responsive gel. The gel swells at low temperatures (\u227232 \u25e6C) and shrinks at high temperatures (\u227332 \u25e6C), therefore, its volume expansion can be controlled by an integrated microheater. When the microheater is turned on, a single cell is trapped by the hole pattern of the single cell catcher. Then, when the microheater is turned off, the single cell catcher is cooled by the ambient temperature. The gel swells at this temperature, and the hole closes to catch the single cell. The caught cell can then be released into culture wells on a microtiter plate by heating the gel again. We conducted single cell extraction with the proposed chip and achieved a 60% success rate, of which 61% cells yielded live cells.<\/jats:p>","DOI":"10.3390\/mi5030681","type":"journal-article","created":{"date-parts":[[2014,9,11]],"date-time":"2014-09-11T02:22:24Z","timestamp":1410402144000},"page":"681-696","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":63,"title":["A Single Cell Extraction Chip Using Vibration-Induced Whirling Flow and a Thermo-Responsive Gel Pattern"],"prefix":"10.3390","volume":"5","author":[{"given":"Takeshi","family":"Hayakawa","sequence":"first","affiliation":[{"name":"Department of Micro-Nano Systems Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya 464-8601, Japan"}]},{"given":"Shinya","family":"Sakuma","sequence":"additional","affiliation":[{"name":"Department of Micro-Nano Systems Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya 464-8601, Japan"}]},{"given":"Takeshi","family":"Fukuhara","sequence":"additional","affiliation":[{"name":"Laboratory of Oncology, School of Life Sciences, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachiohji, Tokyo 192-0392, Japan"}]},{"given":"Yoshiyuki","family":"Yokoyama","sequence":"additional","affiliation":[{"name":"Toyama Industrial Technology Center, 383 Takata, Toyama 930-0866, Japan"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2508-1615","authenticated-orcid":false,"given":"Fumihito","family":"Arai","sequence":"additional","affiliation":[{"name":"Department of Micro-Nano Systems Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya 464-8601, Japan"}]}],"member":"1968","published-online":{"date-parts":[[2014,9,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.tibtech.2010.03.002","article-title":"Single cellanalysis: the new frontier in \u2018omics\u2019","volume":"28","author":"Wang","year":"2010","journal-title":"Trends Biotechnol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1172\/JCI44635","article-title":"Single cell transcriptional profiling reveals heterogeneity of human induced pluripotent stem cells","volume":"121","author":"Narsinh","year":"2011","journal-title":"J. Clin. Investig."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1126\/science.166.3906.747","article-title":"Cell sorting: Automated separation of mammalian cells as a function of intracellular fluorescence","volume":"166","author":"Hulett","year":"1969","journal-title":"Science"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1063\/1.1685647","article-title":"Fluorescence activated cell sorting","volume":"43","author":"Bonner","year":"1972","journal-title":"Rev. Sci. Instrum."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"R73","DOI":"10.1088\/0967-3334\/26\/3\/R02","article-title":"Microfluidics for flow cytometric analysis of cells and particles","volume":"26","author":"Huh","year":"2005","journal-title":"Physiol. Meas."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1038\/15095","article-title":"A microfabricated fluorescence-activated cell sorter","volume":"17","author":"Fu","year":"1999","journal-title":"Nat. Biotechnol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"5465","DOI":"10.1021\/ac049863r","article-title":"Pinched flow fractionation: Continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel","volume":"76","author":"Yamada","year":"2004","journal-title":"Anal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2827","DOI":"10.1039\/c1lc20330d","article-title":"Automated cellular sample preparation using a centrifuge-on-a-chip","volume":"11","author":"Mach","year":"2011","journal-title":"Lab Chip"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1073\/pnas.0606625104","article-title":"A trap-and-release integrated microfluidic system for dynamic microarray applications","volume":"104","author":"Tan","year":"2007","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1039\/b212919a","article-title":"Isolation and extraction of target microbes using thermal sol-gel transformation","volume":"128","author":"Arai","year":"2003","journal-title":"Analyst"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1039\/b502546j","article-title":"On chip single-cell separation and immobilization using optical tweezers and thermosensitive hydrogel","volume":"5","author":"Arai","year":"2005","journal-title":"Lab Chip"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1126\/science.3547653","article-title":"Optical trapping and manipulation of viruses and bacteria","volume":"235","author":"Ashkin","year":"1987","journal-title":"Science"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1002\/1522-2683(200101)22:2<283::AID-ELPS283>3.0.CO;2-C","article-title":"High-speed separation system of randomly suspended single living cells by laser trap and dielectrophoresis","volume":"22","author":"Arai","year":"2001","journal-title":"Electrophoresis"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1039\/B913587A","article-title":"A microfluidic device for reversible environmental changes around single cells using optical tweezers for cell selection and positioning","volume":"10","author":"Eriksson","year":"2010","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"022811","DOI":"10.1063\/1.3456626","article-title":"Review article \u2014Dielectrophoresis: Status of the theory, technology, and applications","volume":"4","author":"Pethig","year":"2010","journal-title":"Biomicrofluidics"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1038\/nature03831","article-title":"Massively parallel manipulation of single cells and microparticles using optical images","volume":"436","author":"Chiou","year":"2005","journal-title":"Nature"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3984","DOI":"10.1021\/ac0256235","article-title":"A microfabrication-based dynamic array cytometer","volume":"74","author":"Voldman","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3626","DOI":"10.1039\/c3lc50361e","article-title":"Surface acoustic wave microfluidics","volume":"13","author":"Ding","year":"2013","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"012002","DOI":"10.1063\/1.3056040","article-title":"Ultrafast microfluidics using surface acoustic waves","volume":"3","author":"Yeo","year":"2009","journal-title":"Biomicrofluidics"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1121\/1.1907285","article-title":"Boundary layer flow near a cylindrical obstacle in an oscillating imcompressible fluid","volume":"26","author":"Holtsmard","year":"1945","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/BF00384371","article-title":"The steady streaming generated by a vibrating plate parallel to a fixed plate","volume":"39","author":"Wand","year":"1982","journal-title":"Appl. Sci. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5429","DOI":"10.1021\/ac060555y","article-title":"Hydrodynamic tweezers: 1. Noncontact trapping of single cells using steady streaming microeddies","volume":"78","author":"Lutz","year":"2006","journal-title":"Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"074102","DOI":"10.1063\/1.4746247","article-title":"Local streamline generation by mechanical oscillation in a microfluidic chip for noncontact cell manipulations","volume":"101","author":"Hagiwara","year":"2012","journal-title":"Appl. Phys. Lett."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"63","DOI":"10.2494\/photopolymer.24.63","article-title":"Micro- and nano-fabrication of stimulus-responsive polymer using nanoimprint lithography","volume":"24","author":"Yokoyama","year":"2011","journal-title":"J. Photopolym. Sci. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Ito, K., Sakuma, S., Yokoyama, Y., and Arai, F. (2014). On-chip gel-valve using photoprocessable thermoresponsive gel. ROBOMECH J.","DOI":"10.1186\/s40648-014-0005-8"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/5\/3\/681\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:15:46Z","timestamp":1760217346000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/5\/3\/681"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9,10]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2014,9]]}},"alternative-id":["mi5030681"],"URL":"https:\/\/doi.org\/10.3390\/mi5030681","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9,10]]}}}