{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T07:53:24Z","timestamp":1794470004796,"version":"4.9.1"},"reference-count":28,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2014,12,23]],"date-time":"2014-12-23T00:00:00Z","timestamp":1419292800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000038","name":"NSERC","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Quantitative, reverse transcription, polymerase chain reaction (qRT-PCR) is facilitated by leveraging droplet microfluidic (DMF) system, which due to its precision dispensing and sample handling capabilities at microliter and lower volumes has emerged as a popular method for miniaturization of the PCR platform. This work substantially improves and extends the functional capabilities of our previously demonstrated single qRT-PCR micro-chip, which utilized a combination of electrostatic and electrowetting droplet actuation. In the reported work we illustrate a spatially multiplexed micro-device that is capable of conducting up to eight parallel, real-time PCR reactions per usage, with adjustable control on the PCR thermal cycling parameters (both process time and temperature set-points). This micro-device has been utilized to detect and quantify the presence of two clinically relevant respiratory viruses, Influenza A and Influenza B, in human samples (nasopharyngeal swabs, throat swabs). The device performed accurate detection and quantification of the two respiratory viruses, over several orders of RNA copy counts, in unknown (blind) panels of extracted patient samples with acceptably high PCR efficiency (&gt;94%). The multi-stage qRT-PCR assays on eight panel patient samples were accomplished within 35\u201340 min, with a detection limit for the target Influenza virus RNAs estimated to be less than 10 RNA copies per reaction.<\/jats:p>","DOI":"10.3390\/mi6010063","type":"journal-article","created":{"date-parts":[[2014,12,23]],"date-time":"2014-12-23T15:33:56Z","timestamp":1419348836000},"page":"63-79","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Multiplex, Quantitative, Reverse Transcription PCR Detection of Influenza Viruses Using Droplet Microfluidic Technology"],"prefix":"10.3390","volume":"6","author":[{"given":"Ravi","family":"Prakash","sequence":"first","affiliation":[{"name":"Biosystems Research and Applications Group, Department of Electrical and Computer Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanti","family":"Pabbaraju","sequence":"additional","affiliation":[{"name":"Provincial Laboratory for Public Health of Alberta, Calgary, AB T2N 4W4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sallene","family":"Wong","sequence":"additional","affiliation":[{"name":"Provincial Laboratory for Public Health of Alberta, Calgary, AB T2N 4W4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anita","family":"Wong","sequence":"additional","affiliation":[{"name":"Provincial Laboratory for Public Health of Alberta, Calgary, AB T2N 4W4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond","family":"Tellier","sequence":"additional","affiliation":[{"name":"Provincial Laboratory for Public Health of Alberta, Calgary, AB T2N 4W4, Canada"},{"name":"Department of Microbiology, Immunology and Infectious Diseases, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karan","family":"Kaler","sequence":"additional","affiliation":[{"name":"Biosystems Research and Applications Group, Department of Electrical and Computer Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,12,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1126\/science.2448875","article-title":"Primer-directed enzymatic amplification of DNA with a thermostable DNA polymerase","volume":"239","author":"Saiki","year":"1988","journal-title":"Science"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1046\/j.1420-9101.1995.8030399.x","article-title":"Mullis, K. B., Ferr\u00e9, F. and Gibbs, R. A. (Eds.). 1994. The polymerase chain reaction (PCR). Birkh\u00e4user Verlag AG, Basel, Switzerland. ISBN 3-7643-3607-2 (H.b.). ISBN 3-7643-3750-8 (P.b.)","volume":"8","author":"Langin","year":"1994","journal-title":"J. Evol. Biol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1002\/jcla.2058","article-title":"Multiplex polymerase chain reaction: A practical approach","volume":"16","author":"Markoulatos","year":"2002","journal-title":"J. Clin. Lab. Anal."},{"key":"ref_4","unstructured":"Logan, J., Edwards, K.J., and Saunders, N. (2009). Real-Time PCR: Current Technology and Applications, Caister Academic Press."},{"key":"ref_5","unstructured":"Wittmer, C.T., and Kusukawa, N. (2011). Molecular Microbiology Diagnostic Principles and Practice, ASM Press. [2nd ed.]."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1126\/science.280.5366.1046","article-title":"Chemical amplification: Continuous-flow PCR on a chip","volume":"280","author":"Kopp","year":"1998","journal-title":"Science"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Manz, A., and Becker, H. (1998). Microsystem Technology in Chemistry and Life Sciences, Springer.","DOI":"10.1007\/3-540-69544-3"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1039\/b109031n","article-title":"Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis","volume":"1\u20132","author":"Lagally","year":"2001","journal-title":"Lab Chip"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1021\/ac0353029","article-title":"Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection","volume":"76","author":"Liu","year":"2004","journal-title":"J. Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1038\/nbt.1583","article-title":"Microdroplet-based PCR enrichment for large-scale targeted sequencing","volume":"27","author":"Tewhey","year":"2009","journal-title":"Nat. Biotechnol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3083","DOI":"10.1149\/2.013402jes","article-title":"Droplet microfluidic chip based nucleic acid amplification and real-time detection of influenza viruses","volume":"161","author":"Prakash","year":"2014","journal-title":"J. Electrochem. Soc."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/s10544-006-9034-2","article-title":"Quantitative PCR based expression analysis on a nanoliter scale using polymer nano-well chips","volume":"9","author":"Dahl","year":"2007","journal-title":"Biomed. Microdev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1038\/nprot.2012.021","article-title":"Microfluidic single-cell real-time PCR for comparative analysis of gene expression patterns","volume":"7","author":"Freire","year":"2012","journal-title":"Nat. Protoc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.bios.2013.01.019","article-title":"Rapid, quantitative, reverse transcription PCR in a polymer microfluidic chip","volume":"44","author":"Saunders","year":"2013","journal-title":"Biosens. Bioelec."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2121","DOI":"10.1039\/b811131f","article-title":"A polymer lab-on-a-chip for reverse transcription (RT)-PCR based point-of-care clinical diagnostics","volume":"8","author":"Lee","year":"2008","journal-title":"Lab Chip"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/gm537","article-title":"Killer-cell Immunoglobulin-like receptor gene linkage and copy number variation analysis by droplet digital PCR","volume":"6","author":"Roberts","year":"2014","journal-title":"Genome Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1063\/1.1308534","article-title":"Electrowetting-based actuation of liquid droplets for microfluidic applications","volume":"77","author":"Pollack","year":"2000","journal-title":"Appl. Phys. Lett."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/JMEMS.2002.807467","article-title":"Creating, Transporting, Cutting, and Merging Liquid Droplets by Electrowetting-Based Actuation for Digital Microfluidic Circuits","volume":"12","author":"Cho","year":"2003","journal-title":"J. Microelectromech. Syst."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2091","DOI":"10.1039\/b814922d","article-title":"Development of a digital microfluidic platform for point of care testing","volume":"8","author":"Sista","year":"2008","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2310","DOI":"10.1021\/ac902510u","article-title":"Multiplexed Real-Time Polymerase Chain Reaction on a Digital Microfluidic Platform","volume":"82","author":"Hua","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1039\/b403341h","article-title":"An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids","volume":"4","author":"Srinivasan","year":"2004","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s10544-006-8171-y","article-title":"Integrated polymerase chain reaction chips utilizing digital microfluidics","volume":"8","author":"Chang","year":"2006","journal-title":"Biomed. Microdev."},{"key":"ref_23","unstructured":"Gunji, M., Nakanishi, H., and Washizu, M. (2004, January September). Droplet actuation based on single-phase electrostatic excitation. Proceedings of 8th International Conf. on Miniaturized Systems in Chemistry and Life Sciences (\u03bc-TAS2004), Malm\u00f6, Sweden."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"022805","DOI":"10.1063\/1.3411003","article-title":"Liquid Dieletrophoresis and Surface Microfluidics","volume":"4","author":"Kaler","year":"2010","journal-title":"Biomicrofluidics"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.snb.2013.03.024","article-title":"Dielectrophoretic liquid actuation on nano-textured super hydrophobic surfaces","volume":"182","author":"Prakash","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/S0925-4005(00)00350-6","article-title":"Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system","volume":"63","author":"Lagally","year":"2006","journal-title":"Sens. Actuators B Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1002\/elps.200800491","article-title":"Simply and reliably integrating micro heaters\/sensors in a monolithic PCR-CE microfluidic genetic analysis system","volume":"30","author":"Zhong","year":"2009","journal-title":"Electrophoresis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2002","DOI":"10.1093\/nar\/29.9.e45","article-title":"A new mathematical model for relative quantification in real-time RT-PCR","volume":"29","author":"Pfaffl","year":"2001","journal-title":"Nucleic Acids Res."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/1\/63\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:11:33Z","timestamp":1760217093000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/1\/63"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,23]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["mi6010063"],"URL":"https:\/\/doi.org\/10.3390\/mi6010063","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,23]]}}}