{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T22:06:12Z","timestamp":1766268372367,"version":"build-2065373602"},"reference-count":22,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2014,12,24]],"date-time":"2014-12-24T00:00:00Z","timestamp":1419379200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>This paper presents a novel dosing concept for drug delivery based on a peristaltic piezo-electrically actuated micro membrane pump. The design of the silicon micropump itself is straight-forward, using two piezoelectrically actuated membrane valves as inlet and outlet, and a pump chamber with a piezoelectrically actuated pump membrane in-between. To achieve a precise dosing, this micropump is used to fill a metering unit placed at its outlet. In the final design this metering unit will be made from a piezoelectrically actuated inlet valve, a storage chamber with an elastic cover membrane and a piezoelectrically actuated outlet valve, which are connected in series. During a dosing cycle the metering unit is used to adjust the drug volume to be dispensed before delivery and to control the actually dispensed volume. To simulate the new drug delivery concept, a lumped parameter model has been developed to find the decisive design parameters. With the knowledge taken from the model a drug delivery system is designed that includes a silicon micro pump and, in a first step, a silicon chip with the storage chamber and two commercial microvalves as a metering unit. The lumped parameter model is capable to simulate the maximum flow, the frequency response created by the micropump, and also the delivered volume of the drug delivery system.<\/jats:p>","DOI":"10.3390\/mi6010080","type":"journal-article","created":{"date-parts":[[2014,12,24]],"date-time":"2014-12-24T11:51:41Z","timestamp":1419421901000},"page":"80-95","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["A New Concept of a Drug Delivery System with Improved Precision and Patient Safety Features"],"prefix":"10.3390","volume":"6","author":[{"given":"Florian","family":"Thoma","sequence":"first","affiliation":[{"name":"Design of Microsystems, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6168-0140","authenticated-orcid":false,"given":"Frank","family":"Goldschmidtb\u00f6ing","sequence":"additional","affiliation":[{"name":"Design of Microsystems, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Woias","sequence":"additional","affiliation":[{"name":"Design of Microsystems, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,12,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Wang, W., and Soper, S.A. (2006). Bio-MEMS: Technologies and Applications, CRC Press.","DOI":"10.1201\/9781420018677"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1590","DOI":"10.1016\/j.addr.2012.02.005","article-title":"Reservoir-based drug delivery systems utilizing microtechnology","volume":"64","author":"Stevenson","year":"2012","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Jain, K.K. (2009). Textbook of Personalized Medicine, Springer.","DOI":"10.1007\/978-1-4419-0769-1"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1016\/j.addr.2012.08.006","article-title":"MEMS-enabled implantable drug infusion pumps for laboratory animal research, preclinical, and clinical applications","volume":"64","author":"Meng","year":"2012","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"R50","DOI":"10.1088\/0960-1317\/17\/5\/R02","article-title":"Microsystem technologies for implantable applications","volume":"17","author":"Receveur","year":"2007","journal-title":"J. Micromech. Microeng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1088\/0960-1317\/15\/4\/001","article-title":"A generic analytical model for micro-diaphragm pumps with active valves","volume":"15","author":"Doll","year":"2005","journal-title":"J. Micromech. Microeng."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Woias, P. (2001, January 22). Micropumps-summarizing the first two decades. Proceeding of SPIE 4560, Microfluidics and BioMEMS, San Francisco, CA, USA.","DOI":"10.1117\/12.443069"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/0924-4247(90)85039-7","article-title":"Piezoelectric micropump with three valves working peristaltically","volume":"21","author":"Smits","year":"1990","journal-title":"Sens. Actuators A Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.sna.2008.01.016","article-title":"Development of serial-connection piezoelectric pumps","volume":"144","author":"Kan","year":"2008","journal-title":"Sens. Actuators A Phys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.sna.2008.12.008","article-title":"Study on a piezohydraulic pump for linear actuators","volume":"149","author":"Kan","year":"2009","journal-title":"Sens. Actuators A Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.sna.2007.11.024","article-title":"An implantable active microport based on a self-priming high-performance two-stage micropump","volume":"145\u2013146","author":"Geipel","year":"2008","journal-title":"Sens. Actuators A Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/S0924-4247(98)00112-5","article-title":"Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena","volume":"70","author":"Dufour","year":"1998","journal-title":"Sens. Actuators A Phys."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1088\/0960-1317\/17\/2\/006","article-title":"Dynamic simulation of a peristaltic micropump considering coupled fluid flow and structural motion","volume":"17","author":"Lin","year":"2007","journal-title":"J. Micromech. Microeng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1088\/0960-1317\/6\/4\/006","article-title":"Modeling micropumps with electrical equivalent networks","volume":"6","author":"Bourouina","year":"1996","journal-title":"J. Micromech. Microeng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3121","DOI":"10.1016\/j.jsv.2010.01.035","article-title":"Modeling and study of dynamic performance of a valveless micropump","volume":"329","author":"Hamdan","year":"2010","journal-title":"J. Sound Vib."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Oertel, H., B\u00f6hle, M., and Dohrmann, U. (2009). Str\u00f6mungsmechanik: Grundlagen, Grundgleichungen, L\u00f6sungsmethoden, Softwarebeispiele, Springer Vieweg. [4th ed.].","DOI":"10.1007\/978-3-8348-9248-5"},{"key":"ref_17","unstructured":"Truckenbrodt, E. (2013). Fluidmechanik, Springer Vieweg. [4th ed.]."},{"key":"ref_18","unstructured":"Goldschmidtb\u00f6ing, F. (2004). Entwurf, Design und Experimentelle Charakterisierung von Mikro-Freistrahldispensern. [Ph.D. Thesis, Universit\u00e4tsbibliothek Freiburg]. (In German)."},{"key":"ref_19","unstructured":"Thoma, F., Feth, H.F., Goldschmidtboeing, F., and Woias, P. (2012, January 3\u20137). Integrated fluidic system for an artificial sphincter prosthesis. Proceeding of 2012 IEEE Micro- and Nanoengineering in Medicine Conference, Maui, HI, USA."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"105022","DOI":"10.1088\/0960-1317\/20\/10\/105022","article-title":"Design and simulation of advanced charge recovery piezoactuator drivers","volume":"20","author":"Biancuzzi","year":"2010","journal-title":"J. Micromech. Microeng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1896","DOI":"10.1109\/T-ED.1979.19783","article-title":"Development of a miniature pressure transducer for biomedical applications","volume":"26","author":"Ko","year":"1979","journal-title":"IEEE Trans. Electron Devices"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1631\/jzus.C12MNT03","article-title":"A planar capacitive sensor for 2D long-range displacement measurement","volume":"14","author":"Yu","year":"2013","journal-title":"J. Zhejiang Univ. Sci C"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/1\/80\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:11:42Z","timestamp":1760217102000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/1\/80"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,24]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["mi6010080"],"URL":"https:\/\/doi.org\/10.3390\/mi6010080","relation":{},"ISSN":["2072-666X"],"issn-type":[{"type":"electronic","value":"2072-666X"}],"subject":[],"published":{"date-parts":[[2014,12,24]]}}}