{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T19:16:59Z","timestamp":1776712619850,"version":"3.51.2"},"reference-count":47,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2015,2,6]],"date-time":"2015-02-06T00:00:00Z","timestamp":1423180800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>In the past decade a large amount of analysis techniques have been scaled down to the microfluidic level. However, in many cases the necessary sample preparation, such as separation, mixing and concentration, remains to be performed off-chip. This represents a major hurdle for the introduction of miniaturized sample-in\/answer-out systems, preventing the exploitation of microfluidic\u2019s potential for small, rapid and accurate diagnostic products. New flow engineering methods are required to address this hitherto insufficiently studied aspect. One microfluidic tool that can be used to miniaturize and integrate sample preparation procedures are microvortices. They have been successfully applied as microcentrifuges, mixers, particle separators, to name but a few. In this work, we utilize a novel corner structure at a sudden channel expansion of a microfluidic chip to enhance the formation of a microvortex. For a maximum area of the microvortex, both chip geometry and corner structure were optimized with a computational fluid dynamic (CFD) model. Fluorescent particle trace measurements with the optimized design prove that the corner structure increases the size of the vortex. Furthermore, vortices are induced by the corner structure at low flow rates while no recirculation is observed without a corner structure. Finally, successful separation of plasma from human blood was accomplished, demonstrating a potential application for clinical sample preparation. The extracted plasma was characterized by a flow cytometer and compared to plasma obtained from a standard benchtop centrifuge and from chips without a corner structure.<\/jats:p>","DOI":"10.3390\/mi6020239","type":"journal-article","created":{"date-parts":[[2015,2,6]],"date-time":"2015-02-06T10:51:12Z","timestamp":1423219872000},"page":"239-251","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Microfluidic Vortex Enhancement for on-Chip Sample Preparation"],"prefix":"10.3390","volume":"6","author":[{"given":"Anna","family":"Haller","sequence":"first","affiliation":[{"name":"Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstrasse 27-29\/E366, 1040 Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2657-6836","authenticated-orcid":false,"given":"Andreas","family":"Spittler","sequence":"additional","affiliation":[{"name":"Core Facility Flow Cytometry & Department of Surgery, Research Laboratories, Center of Translational Research, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lukas","family":"Brandhoff","sequence":"additional","affiliation":[{"name":"Institute of Microsensors, -Actuators and -Systems (IMSAS) & Microsystems Center Bremen (MCB), University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helene","family":"Zirath","sequence":"additional","affiliation":[{"name":"Health and Environment Department, Austrian Institute of Technology, Muthgasse 11, 1190 Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dietmar","family":"Puchberger-Enengl","sequence":"additional","affiliation":[{"name":"Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstrasse 27-29\/E366, 1040 Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franz","family":"Keplinger","sequence":"additional","affiliation":[{"name":"Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstrasse 27-29\/E366, 1040 Vienna, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Vellekoop","sequence":"additional","affiliation":[{"name":"Institute of Microsensors, -Actuators and -Systems (IMSAS) & Microsystems Center Bremen (MCB), University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,2,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1039\/c2lc41104k","article-title":"Microfluidic sample preparation for diagnostic cytopathology","volume":"13","author":"Mach","year":"2013","journal-title":"Lab Chip"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1021\/ac403688g","article-title":"Micro total analysis systems: Fundamental advances and biological applications","volume":"86","author":"Culbertson","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1002\/1522-2683(200203)23:5<677::AID-ELPS677>3.0.CO;2-8","article-title":"Microfluidic chips for clinical and forensic analysis","volume":"23","author":"Verpoorte","year":"2002","journal-title":"Electrophoresis"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1039\/c4lc00128a","article-title":"Inertial microfluidic physics","volume":"14","author":"Amini","year":"2014","journal-title":"Lab Chip"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1038\/425038a","article-title":"Microfluidic systems: High radial acceleration in microvortices","volume":"425","author":"Shelby","year":"2003","journal-title":"Nature"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1039\/b402479f","article-title":"Controlled rotation of biological micro- and nano-particles in microvortices","volume":"4","author":"Shelby","year":"2004","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s00216-006-0611-2","article-title":"Cellular manipulations in microvortices","volume":"387","author":"Chiu","year":"2007","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2827","DOI":"10.1039\/c1lc20330d","article-title":"Automated cellular sample preparation using a Centrifuge-on-a-Chip","volume":"11","author":"Mach","year":"2011","journal-title":"Lab Chip"},{"key":"ref_9","first-page":"317","article-title":"Microfluidic centrifuge based on a counterflow configuration","volume":"12","author":"Baier","year":"2011","journal-title":"Microfluid. Nanofluid."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.snb.2007.11.027","article-title":"Microfluidic centrifuge of nano-particles using rotating flow in a microchamber","volume":"132","author":"Lee","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1039\/B813952K","article-title":"Continuous focusing of microparticles using inertial lift force and vorticity via multi-orifice microfluidic channels","volume":"9","author":"Park","year":"2009","journal-title":"Lab Chip"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"044119","DOI":"10.1063\/1.4818906","article-title":"Vortex-aided inertial microfluidic device for continuous particle separation with high size-selectivity, efficiency, and purity","volume":"7","author":"Wang","year":"2013","journal-title":"Biomicrofluidics"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1039\/b813434k","article-title":"Microvortex for focusing, guiding and sorting of particles","volume":"8","author":"Hsu","year":"2008","journal-title":"Lab Chip"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"529","DOI":"10.3390\/mi3020529","article-title":"Simulation and experimental characterization of microscopically accessible hydrodynamic microvortices","volume":"3","author":"Zhang","year":"2012","journal-title":"Micromachines"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/s10404-013-1176-y","article-title":"Enhanced size-dependent trapping of particles using microvortices","volume":"15","author":"Zhou","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1021\/nl2032487","article-title":"Selective trapping and manipulation of microscale objects using mobile microvortices","volume":"12","author":"Petit","year":"2012","journal-title":"Nano Lett."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"022206","DOI":"10.1063\/1.3576780","article-title":"High-throughput size-based rare cell enrichment using microscale vortices","volume":"5","author":"Hur","year":"2011","journal-title":"Biomicrofluidics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1039\/C3LC50689D","article-title":"Size-selective collection of circulating tumor cells using Vortex technology","volume":"14","author":"Sollier","year":"2014","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1007\/s10544-010-9456-8","article-title":"Rapid multivortex mixing in an alternately formed contraction-expansion array microchannel","volume":"12","author":"Lee","year":"2010","journal-title":"Biomed. Microdevices"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1016\/j.ces.2008.11.011","article-title":"Mixing efficiency of a multilamination micromixer with consecutive recirculation zones","volume":"64","author":"Lee","year":"2009","journal-title":"Chem. Eng. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s10404-007-0238-4","article-title":"A high-efficiency planar micromixer with convection and diffusion mixing over a wide Reynolds number range","volume":"5","author":"Shih","year":"2007","journal-title":"Microfluid. Nanofluid."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3587","DOI":"10.1021\/nl301253v","article-title":"Mass production and size control of lipid-polymer hybrid nanoparticles through controlled microvortices","volume":"12","author":"Kim","year":"2012","journal-title":"Nano Lett."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s10404-013-1296-4","article-title":"Multi-step microfluidic system for blood plasma separation: Architecture and separation efficiency","volume":"17","author":"Marchalot","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s10544-010-9405-6","article-title":"Fast and continuous plasma extraction from whole human blood based on expanding cell-free layer devices","volume":"12","author":"Sollier","year":"2010","journal-title":"Biomed. Microdevices"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10404-013-1291-9","article-title":"Particle separation and sorting in microfluidic devices: A review","volume":"17","author":"Sajeesh","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/s10404-013-1200-2","article-title":"Study on microchannel flows with a sudden contraction-expansion at a wide range of Knudsen number using lattice Boltzmann method","volume":"16","author":"Liou","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/s10404-014-1343-9","article-title":"Unsteady pulsating characteristics of the fluid flow through a sudden expansion microvalve","volume":"17","author":"Nejat","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1007\/s10404-012-1005-8","article-title":"Investigations of vortex formation in microbifurcations","volume":"13","author":"Balan","year":"2012","journal-title":"Microfluid. Nanofluid."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"026308","DOI":"10.1103\/PhysRevE.82.026308","article-title":"Dynamic particle trapping, release, and sorting by microvortices on a substrate","volume":"82","author":"Liu","year":"2010","journal-title":"Phys. Rev. E"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"044114","DOI":"10.1063\/1.4771407","article-title":"Bacterial aggregation and biofilm formation in a vortical flow","volume":"6","author":"Yazdi","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1758","DOI":"10.1007\/s00348-014-1758-9","article-title":"Vortex generation in a microfluidic chamber with actuations","volume":"55","author":"Shang","year":"2014","journal-title":"Exp. Fluids"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2016","DOI":"10.1039\/b821247c","article-title":"Self-powered microfluidic chips for multiplexed protein assays from whole blood","volume":"9","author":"Qin","year":"2009","journal-title":"Lab Chip"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"14103","DOI":"10.1063\/1.2409629","article-title":"Microfluidic blood plasma separation via bulk electrohydrodynamic flows","volume":"1","author":"Arifin","year":"2007","journal-title":"Biomicrofluidics"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"233512","DOI":"10.1063\/1.2212275","article-title":"Electrohydrodynamic surface microvortices for mixing and particle trapping","volume":"88","author":"Yeo","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/s10404-013-1166-0","article-title":"Mapping low-Reynolds-number microcavity flows using microfluidic screening devices","volume":"15","author":"Fishler","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s10404-011-0864-8","article-title":"Formation of recirculation zones in a sudden expansion microchannel with a rectangular block structure over a wide Reynolds number range","volume":"12","author":"Tsai","year":"2011","journal-title":"Microfluid. Nanofluid."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"24108","DOI":"10.1063\/1.4704504","article-title":"High-performance microfluidic rectifier based on sudden expansion channel with embedded block structure","volume":"6","author":"Tsai","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1115\/1.1760532","article-title":"Backward-facing step flows for various expansion ratios at low and moderate Reynolds numbers","volume":"126","author":"Biswas","year":"2004","journal-title":"J. Fluids Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/j.proeng.2011.12.109","article-title":"Towards an optimized blood plasma separation chip: Finite element analysis of a novel corner structure in a backward-facing step","volume":"25","author":"Haller","year":"2011","journal-title":"Procedia Eng."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"16505","DOI":"10.1063\/1.3689939","article-title":"A practical guide for the fabrication of microfluidic devices using glass and silicon","volume":"6","author":"Iliescu","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1002\/smll.201302907","article-title":"Microfluidic blood cell sorting: Now and beyond","volume":"10","author":"Yu","year":"2014","journal-title":"Small"},{"key":"ref_42","first-page":"147","article-title":"Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma","volume":"43","author":"Faivre","year":"2006","journal-title":"Biorheology"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"319","DOI":"10.3390\/mi2030319","article-title":"Microfluidic devices for blood fractionation","volume":"2","author":"Hou","year":"2011","journal-title":"Micromachines"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"3323","DOI":"10.1039\/c3lc50432h","article-title":"Micro-scale blood plasma separation: From acoustophoresis to egg-beaters","volume":"13","author":"Sollier","year":"2013","journal-title":"Lab Chip"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.snb.2009.05.023","article-title":"Passive microfluidic devices for plasma extraction from whole human blood","volume":"141","author":"Sollier","year":"2009","journal-title":"Sensors Actuators B Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1002\/bit.22833","article-title":"Continuous scalable blood filtration device using inertial microfluidics","volume":"107","author":"Mach","year":"2010","journal-title":"Biotechnol. Bioeng."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1039\/b926834k","article-title":"Validation of a blood plasma separation system by biomarker detection","volume":"10","author":"Kavanagh","year":"2010","journal-title":"Lab Chip"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/2\/239\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:42:27Z","timestamp":1760215347000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/2\/239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,6]]},"references-count":47,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2015,2]]}},"alternative-id":["mi6020239"],"URL":"https:\/\/doi.org\/10.3390\/mi6020239","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,6]]}}}