{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:23:05Z","timestamp":1760242985813,"version":"build-2065373602"},"reference-count":42,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2015,3,23]],"date-time":"2015-03-23T00:00:00Z","timestamp":1427068800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>This paper presents a transdermal power transfer device for the application of implantable devices or systems. The device mainly consists of plug and socket. The power transfer process can be started after inserting the plug into the socket with an applied potential on the plug. In order to improve the maneuverability and reliability of device during power transfer process, the metal net with mesh structure were added as a part of the socket to serve as intermediate electrical connection layer. The socket was encapsulated by polydimethylsiloxane (PDMS) with good biocompatibility and flexibility. Two stainless steel hollow needles placed in the same plane acted as the insertion part of the needle plug, and Parylene C thin films were deposited on needles to serve as insulation layers. At last,  the properties of the transdermal power transfer device were tested. The average contact resistance between needle and metal mesh was 0.454 \u03a9 after 50 random insertions, which showed good electrical connection. After NiMH (nickel-metal hydride) batteries were recharged for 10 min with current up to 200 mA, the caused resistive heat was less than  0.6 \u00b0C, which also demonstrated the low charging temperature and was suitable for charging implantable devices.<\/jats:p>","DOI":"10.3390\/mi6030396","type":"journal-article","created":{"date-parts":[[2015,3,23]],"date-time":"2015-03-23T12:17:00Z","timestamp":1427113020000},"page":"396-408","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Transdermal Power Transfer Device for the Application of Implantable Microsystems"],"prefix":"10.3390","volume":"6","author":[{"given":"Jing-Quan","family":"Liu","sequence":"first","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue-Feng","family":"Rui","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiao-Yang","family":"Kang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Yang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiang","family":"Chen","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chun-Sheng","family":"Yang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Science and Technology on Micro\/Nano Fabrication, Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering,  Department of Micro\/Nano-electronics, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,3,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Gamini, D.S., and Shastry, P.N. (2009, January 7\u201312). Design and measurements of implantable chip radiator and external receptor for wireless blood pressure monitoring system. Proceedings of IEEE 2009 MTT-S International Microwave Symposium Digest, Boston, MA, USA.","DOI":"10.1109\/MWSYM.2009.5166038"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Hao, S.Y., Taylor, J., Miles, A.W., and Bowen, C.R. (2009, January 5\u20137). An implantable electronic system for in-vivo stability evaluation of prosthesis in total hip and knee arthroplasty. Proceedings of IEEE 2009 Instrumentation and Measurement Technology Conference, Singapore.","DOI":"10.1109\/IMTC.2009.5168438"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Ko, W.H., Guo, J., Ye, X.S., Zhang, R., Young, D.J., and Megerian, C.A. (2008, January 18\u201321). Mems acoustic sensors for totally implantable hearing aid systems. Proceedings of IEEE 2008 International Symposium on Circuits and Systems (ISCAS 2008), Seattle, WA, USA.","DOI":"10.1109\/ISCAS.2008.4541792"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s10544-010-9491-5","article-title":"Implantable drug delivery device using frequency-controlled wireless hydrogel microvalves","volume":"13","author":"Rahimi","year":"2011","journal-title":"Biomed. Microdevices"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/j.addr.2004.02.008","article-title":"Biodegradable polymers and their potential use in parenteral veterinary drug delivery systems","volume":"56","author":"Winzenburg","year":"2004","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1007\/s10544-009-9344-2","article-title":"A monolithic polymeric microdevice for pH-responsive drug delivery","volume":"11","author":"Chen","year":"2009","journal-title":"Biomed. Microdevices"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1213\/ane.0b013e318181b818","article-title":"Perioperative management of patients with an intrathecal drug delivery system for chronic pain","volume":"107","author":"Grider","year":"2008","journal-title":"Anesth. Analg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s10544-007-9132-9","article-title":"A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord","volume":"10","author":"Meacham","year":"2008","journal-title":"Biomed. Microdevices"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.heares.2007.11.014","article-title":"Cochlear nucleus auditory prostheses","volume":"242","author":"McCreery","year":"2008","journal-title":"Hear. Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1109\/JPROC.2008.922577","article-title":"Cochlear and brainstern auditory prostheses \u201cneural interface for hearing restoration: Cochlear and brain stem implants\u201d","volume":"96","author":"Fayad","year":"2008","journal-title":"Proc. IEEE"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1109\/JMEMS.2010.2090498","article-title":"Arrowhead-shaped microelectrodes fabricated on a flexible substrate for enhancing the spherical conformity of retinal prostheses","volume":"20","author":"Koo","year":"2011","journal-title":"J. Microelectromech. Syst."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1146\/annurev.bioeng.10.061807.160547","article-title":"Ultralow-power electronics for biomedical applications","volume":"10","author":"Chandrakasan","year":"2008","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1109\/TBCAS.2013.2284254","article-title":"An efficient and compact compressed sensing microsystem for implantable neural recordings","volume":"8","author":"Zhang","year":"2014","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"6014","DOI":"10.3390\/s130506014","article-title":"An implantable neural sensing microsystem with fiber-optic data transmission and power delivery","volume":"13","author":"Park","year":"2013","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"4624","DOI":"10.3390\/s130404624","article-title":"A wireless and batteryless microsystem with implantable grid electrode\/3-dimensional probe array for ecog and extracellular neural recording in rats","volume":"13","author":"Chang","year":"2013","journal-title":"Sensors"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2466","DOI":"10.1109\/TBME.2012.2203131","article-title":"An inductively powered implantable blood flow sensor microsystem for vascular grafts","volume":"59","author":"Cheong","year":"2012","journal-title":"IEEE Trans. BioMed. Eng."},{"key":"ref_17","first-page":"201","article-title":"Trends in cardiac pacemaker batteries","volume":"4","author":"Mallela","year":"2004","journal-title":"Indian Pacing Electrophysiol. J."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Cong, P., Suster, M.A., Chaimanonart, N., and Young, D.J. (2009, January 25\u201328). Wireless power recharging for implantable bladder pressure sensor. Proceedings of 2009 IEEE Sensors, Christchurch, New Zealand.","DOI":"10.1109\/ICSENS.2009.5398518"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1117\/12.600621","article-title":"Remote power delivery for hybrid integrated bio-implantable electrical stimulation system","volume":"5763","author":"Gaddam","year":"2005","journal-title":"Proc. SPIE"},{"key":"ref_20","unstructured":"Li, P.F., Bashirullah, R., and Principe, J.C. (2006, January 21\u201324). A low power battery management system for rechargeable wireless implantable electronics. Proceedings of 2006 IEEE International Symposium on Circuits and Systems, 2006, ISCAS 2006, Island of Kos, Greece."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s10544-009-9371-z","article-title":"Transdermal power transfer for recharging implanted drug delivery devices via the refill port","volume":"12","author":"Evans","year":"2010","journal-title":"Biomed. Microdevices"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3631","DOI":"10.1109\/JSSC.2009.2035551","article-title":"A wireless and batteryless 10-bit implantable blood pressure sensing microsystem with adaptive RF powering for real-time laboratory mice monitoring","volume":"44","author":"Cong","year":"2009","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_23","first-page":"327","article-title":"Wireless implantable blood pressure sensing microsystem design for monitoring of small laboratory animals","volume":"20","author":"Cong","year":"2008","journal-title":"Sens. Mater."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1109\/MCOM.2010.5439082","article-title":"Integrated electronic system design for an implantable wireless batteryless blood pressure sensing microsystem","volume":"48","author":"Cong","year":"2010","journal-title":"IEEE Commun. Mag."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1109\/JSEN.2009.2030982","article-title":"Wireless batteryless implantable blood pressure monitoring microsystem for small laboratory animals","volume":"10","author":"Cong","year":"2010","journal-title":"IEEE Sens. J."},{"key":"ref_26","first-page":"5","article-title":"Low-power implantable microsystem intended to multichannel cortical recording","volume":"4","author":"Gosselin","year":"2004","journal-title":"IEEE Int. Symp. Circuits Syst."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Martelli, D., Silvani, A., McAllen, R.M., May, C.N., and Ramchandra, R. (2014). The low frequency power of heart rate variability is neither a measure of cardiac sympathetic tone nor of baroreflex sensitivity. Am. J. Physiol. Heart. Circ. Physiol., 307.","DOI":"10.1152\/ajpheart.00361.2014"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1007\/s00421-014-2913-y","article-title":"Modified high-intensity interval training increases peak cardiac power output in patients with heart failure","volume":"114","author":"Huang","year":"2014","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Grodin, J.L., Dupont, M., Mullens, W., Taylor, D.O., Starling, R.C., and Tang, W. (2014). The prognostic role of cardiac power indices in advanced chronic heart failure. J. Heart Lung Transpl., 33.","DOI":"10.1016\/j.healun.2014.01.133"},{"key":"ref_30","unstructured":"Mun, J.Y., Seo, M.G., Kang, W.G., Jun, H.Y., Park, Y.H., and Pack, J.K. (2012, January 19\u201323). Study on the human effect of a wireless power transfer device at low frequency. Proceedings of 2012 Progress in Electromagnetics Research Symposium (PIERS 2012), Moscow, Russia."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Leung, H.Y., Budgett, D.M., Taberner, A., and Hu, P. (2014). Power loss measurement of implantable wireless power transfer components using a peltier device balance calorimeter. Meas. Sci. Technol., 25.","DOI":"10.1088\/0957-0233\/25\/9\/095010"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1109\/TBME.2013.2280460","article-title":"Noninvasive control of the power transferred to an implanted device by an ultrasonic transcutaneous energy transfer link","volume":"61","author":"Shmilovitz","year":"2014","journal-title":"IEEE Trans. BioMed. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"210170","DOI":"10.1155\/2014\/210170","article-title":"Analysis of heat transfer in power split device for hybrid electric vehicle using thermal network method","volume":"2014","author":"Wang","year":"2014","journal-title":"Adv. Mech. Eng."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Jonah, O., Georgakopoulos, S.V., and Tentzeris, M.M. (2013, January 7\u20139). Wireless power transfer to mobile wearable device via resonance magnetic. Proceedings of IEEE 14th Annual Wireless and Microwave Technology Conference (WAMICON), Orlando, FL, USA.","DOI":"10.1109\/WAMICON.2013.6572768"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3009","DOI":"10.1109\/TMAG.2012.2236347","article-title":"Decoupled modeling in a multifrequency domain: Integration of actuation and power transfer in one device","volume":"49","author":"Krop","year":"2013","journal-title":"IEEE Trans. Magn."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1002\/nau.22427","article-title":"Diagnostic power of the noninvasive condom catheter method in patients eligible for transurethral resection of the prostate","volume":"33","author":"Boeve","year":"2014","journal-title":"Neurourol. Urodynam."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.echo.2013.06.013","article-title":"Noninvasive assessment of vascular function and hydraulic power and efficiency in pediatric fontan patients","volume":"26","author":"Myers","year":"2013","journal-title":"J. Am. Soc. Echocardiog."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2811","DOI":"10.1109\/TMAG.2011.2151273","article-title":"The improvement of the noninvasive power-supply system using magnetic coupling for medical implants","volume":"47","author":"Suzuki","year":"2011","journal-title":"IEEE Trans. Magn."},{"key":"ref_39","first-page":"1481","article-title":"Research on continuum power regression in noninvasive measurement of human blood glucose","volume":"31","author":"Li","year":"2011","journal-title":"Spectrosc. Spect. Anal."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.snb.2007.10.069","article-title":"Flexible parylene-based multielectrode array technology for high-density neural stimulation and recording","volume":"132","author":"Rodger","year":"2008","journal-title":"Sens. Actuat. B Chem."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Wei, P., Taylor, R., Ding, Z., Chung, C., Abilez, O.J., Higgs, G., Pruitt, B.L., and Ziaie, B. (2011). Stretchable microelectrode array using room-temperature liquid alloy interconnects. J. Micromech. Microeng., 21.","DOI":"10.1088\/0960-1317\/21\/5\/054015"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s10544-011-9613-8","article-title":"Parylene-based implantable platinum-black coated wire microelectrode for orbicularis oculi muscle electrical stimulation","volume":"14","author":"Rui","year":"2012","journal-title":"Biomed. Microdevices"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/3\/396\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:43:49Z","timestamp":1760215429000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/3\/396"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3,23]]},"references-count":42,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2015,3]]}},"alternative-id":["mi6030396"],"URL":"https:\/\/doi.org\/10.3390\/mi6030396","relation":{},"ISSN":["2072-666X"],"issn-type":[{"type":"electronic","value":"2072-666X"}],"subject":[],"published":{"date-parts":[[2015,3,23]]}}}