{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T21:08:37Z","timestamp":1770152917498,"version":"3.49.0"},"reference-count":31,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2015,4,7]],"date-time":"2015-04-07T00:00:00Z","timestamp":1428364800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>The unibody lab-on-a-chip (ULOC) concept entails a fast and affordable  micro-prototyping system built around a single monolithic 3D printed element (unibody). A consumer-grade stereo lithography (SL) 3D printer can configure ULOCs with different forms of sample delivery, transport, handling and readout, while minimizing material costs and fabrication time. ULOC centralizes all complex fabrication procedures and replaces the need for clean room resources, delivering prototypes for less than 1 US$, which can be printed in 10 min and ready for testing in less than 30 min. Recent examples of ULOC integration of transport, chemical sensing for optical readout and flow mixing capabilities are discussed, as well as the integration of the first check-valves for ULOC devices. ULOC valves are strictly unidirectional up to 100 psi, show an exponential forward flow behavior up to 70 psi and can be entirely fabricated with the ULOC approach.<\/jats:p>","DOI":"10.3390\/mi6040437","type":"journal-article","created":{"date-parts":[[2015,4,8]],"date-time":"2015-04-08T03:01:07Z","timestamp":1428462067000},"page":"437-451","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":48,"title":["3D Printed Unibody Lab-on-a-Chip: Features Survey and Check-Valves Integration"],"prefix":"10.3390","volume":"6","author":[{"given":"Germ\u00e1n","family":"Comina","sequence":"first","affiliation":[{"name":"Optical Devices Laboratory, Department of Physics, Chemistry and Biology, Link\u00f6ping University, S58183 Link\u00f6ping, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anke","family":"Suska","sequence":"additional","affiliation":[{"name":"Optical Devices Laboratory, Department of Physics, Chemistry and Biology, Link\u00f6ping University, S58183 Link\u00f6ping, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Filippini","sequence":"additional","affiliation":[{"name":"Optical Devices Laboratory, Department of Physics, Chemistry and Biology, Link\u00f6ping University, S58183 Link\u00f6ping, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,4,7]]},"reference":[{"key":"ref_1","unstructured":"Mitra, S.K., and Chakraborty, S. (2012). Microfluidics and Nanofluidics Handbook: Fabrication, Implementation, and Applications, CRC Press and Taylor & Francis Group."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"6005","DOI":"10.1021\/la010655t","article-title":"Microscope projection photolithography for rapid prototyping of masters with micron-scale features for use in soft lithography","volume":"17","author":"Love","year":"2001","journal-title":"Langmuir"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.sna.2004.12.011","article-title":"Projection micro-stereolithography using digital micro-mirror dynamic mask","volume":"121","author":"Sun","year":"2005","journal-title":"Sens. Actuators A Phys."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1039\/C0LC00331J","article-title":"Fabrication of monolithic 3D micro-systems","volume":"11","author":"Preechaburana","year":"2011","journal-title":"Lab Chip"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1021\/ac010938q","article-title":"Prototyping of microfluidic devices in poly(dimethylsiloxane) using solid-object printing","volume":"74","author":"McDonald","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"3267","DOI":"10.1039\/c2lc40761b","article-title":"Configurable 3D-printed millifluidic and microfluidic \u201clab on a chip\u201d reactionware devices","volume":"12","author":"Kitson","year":"2012","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Evans, B. (2012). Practical 3D Printers: The Science and Art of 3D Printing, Apress and Springer Science+Business Media.","DOI":"10.1007\/978-1-4302-4393-9"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3124","DOI":"10.1021\/ac4041857","article-title":"Cost-effective three-dimensional printing of visibly transparent microchips within minutes","volume":"86","author":"Shallan","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1039\/C3LC50956G","article-title":"PDMS lab-on-a-chip fabrication using 3D printed templates","volume":"14","author":"Comina","year":"2014","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2978","DOI":"10.1039\/C4LC00394B","article-title":"Low cost lab-on-a-chip prototyping with a consumer grade 3D printer","volume":"14","author":"Comina","year":"2014","journal-title":"Lab Chip"},{"key":"ref_11","unstructured":"MiiCraft\u00ae,MiiCraft 3D Printer. Available online: http:\/\/www.miicraft.com\/products\/."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Wong, R., Harley, I., and Tse, Y. (2009). Lateral Flow Immunoassay, Humana Press and Springer Science+Business Media.","DOI":"10.1007\/978-1-59745-240-3"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"479","DOI":"10.5012\/bkcs.2006.27.4.479","article-title":"Microfluidic immunoassay platform using antbody-immobilized glas beads and its appliacation for the detection of Escherichia coli O157:H7","volume":"27","author":"Lee","year":"2006","journal-title":"Bull. Korean Chem. Soc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"179","DOI":"10.3390\/mi2020179","article-title":"Microvalves and micropumps for BioMEMS","volume":"2","author":"Au","year":"2011","journal-title":"Micromachines"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.sna.2006.07.016","article-title":"Planar micro-check valves exploiting large polymer compliance","volume":"134","author":"Yang","year":"2007","journal-title":"Sens. Actuators A Phys."},{"key":"ref_16","unstructured":"Mosadegh, B., Kuo, C., Tung, Y., Torisawa, Y., and Takayama, S. (2008, January 12\u201316). A monolithic passive check-valve for systematic control of temporal actuation in microfluidic devices. Proceedings of the Twelfth International Conference on Miniaturized Systems for Chemistry and Life Sciences, San Diego, CA, USA."},{"key":"ref_17","unstructured":"Suska, A., Comina, G., and Filippini, D. (2014, January 8\u201310). Unibody three channels injector with integrated manual pumps. Proceedings of the MFHS 2014\u20132nd International Conference on MicroFluidic Handling Systems, Freiburg, Germany."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.bios.2009.08.012","article-title":"G protein-coupled receptor mediated trimethylamine sensing","volume":"25","author":"Suska","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/978-1-61779-108-6_5","article-title":"Assessment of cell proliferation with resazurin-based fluorescent dye","volume":"740","author":"Czekanska","year":"2011","journal-title":"Methods Mol. Biol."},{"key":"ref_20","unstructured":"3D Printer Guide. Available online: http:\/\/www.3dhubs.com\/best-3d-printer-guide."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1080\/10715760310001616032","article-title":"Hydrogen peroxide in urine as a potential biomarker of whole body oxidative stress","volume":"37","author":"Yuen","year":"2003","journal-title":"Free Radic. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1042\/BJ20061131","article-title":"Oxidative stress and cancer: Have we moved forward?","volume":"401","author":"Halliwell","year":"2007","journal-title":"Biochem. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/BF00944786","article-title":"Oxidative stress and heart failure","volume":"147","author":"Singh","year":"1995","journal-title":"Mol. Cell. Biochem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10544-008-9187-2","article-title":"Autonomous capillary system for one-step immunoassays","volume":"11","author":"Zimmermann","year":"2009","journal-title":"Biomed. Microdevices"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"19606","DOI":"10.1073\/pnas.0810903105","article-title":"Three-dimensional microfluidic devices fabricated in layered paper and tape","volume":"105","author":"Martinez","year":"2008","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7091","DOI":"10.1021\/ac901071p","article-title":"Understanding wax printing: A simple micropatterning process for paper-based microfluidics","volume":"81","author":"Carrilho","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0960-1317\/15\/2\/R01","article-title":"Micromixers\u2014A review","volume":"15","author":"Nguyen","year":"2005","journal-title":"J. Micromech. Microeng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"11585","DOI":"10.1002\/anie.201206804","article-title":"Surface plasmon resonance chemical sensing on cell phones","volume":"52","author":"Preechaburana","year":"2012","journal-title":"Angew. Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3790","DOI":"10.1039\/C4LC00500G","article-title":"Finger-powered microfluidic systems using multilayer soft lithography and injection molding processes","volume":"14","author":"Iwai","year":"2014","journal-title":"Lab Chip"},{"key":"ref_30","unstructured":"Somos\u00ae WaterShed XC 11122: The Difference Is Clear. Available online: http:\/\/www.dsm.com\/products\/somos\/en_US\/offerings\/offerings-somos-water-shed.html."},{"key":"ref_31","unstructured":"ASIGA Material World. Available online: https:\/\/www.asiga.com\/products\/materials\/."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/4\/437\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:44:23Z","timestamp":1760215463000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/4\/437"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4,7]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2015,4]]}},"alternative-id":["mi6040437"],"URL":"https:\/\/doi.org\/10.3390\/mi6040437","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,4,7]]}}}