{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:23:56Z","timestamp":1760243036425,"version":"build-2065373602"},"reference-count":51,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2015,5,7]],"date-time":"2015-05-07T00:00:00Z","timestamp":1430956800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>The choice of substrate material in a chip that combines ultrasound with microfluidics for handling biological and synthetic microparticles can have a profound effect on the performance of the device. This is due to the high surface-to-volume ratio that exists within such small structures and acquires particular relevance in polymer-based resonators with 3D standing waves. This paper presents three chips developed to perform particle flow-through separation by ultrasound based on a polymeric SU-8 layer containing channelization over three different substrates: Polymethyl methacrylate (PMMA); Pyrex; and a cracked PMMA composite-like structure. Through direct observations of polystyrene microbeads inside the channel, the three checked chips exhibit their potential as disposable continuous concentration devices with different spatial pressure patterns at frequencies of resonance close to 1 Mhz. Chips with Pyrex and cracked PMMA substrates show restrictions on the number of pressure nodes established in the channel associated with the inhibition of 3D modes in the solid structure. The glass-substrate chip presents some advantages associated with lower energy requirements to collect particles. According to the results, the use of polymer-based chips with rigid substrates can be advantageous for applications that require short treatment times (clinical tests handling human samples) and low-cost fabrication.<\/jats:p>","DOI":"10.3390\/mi6050574","type":"journal-article","created":{"date-parts":[[2015,5,7]],"date-time":"2015-05-07T10:54:29Z","timestamp":1430996069000},"page":"574-591","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Optimizing Polymer Lab-on-Chip Platforms for Ultrasonic Manipulation: Influence of the Substrate"],"prefix":"10.3390","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1814-5235","authenticated-orcid":false,"given":"Itziar","family":"Gonz\u00e1lez","sequence":"first","affiliation":[{"name":"Group of Ultrasonic Resonators, Institute of Physical Technologies and Information, Spanish National Research Council CSIC, Serrano 144, 28006 Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mar\u00eda","family":"Tijero","sequence":"additional","affiliation":[{"name":"Department of Microsystems, IKERLAN, Jose Maria Arizmendiarreta 2, 20500 Mondrag\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9501-3028","authenticated-orcid":false,"given":"Alain","family":"Martin","sequence":"additional","affiliation":[{"name":"Group of Microfludics, Politechnical University of Mondrag\u00f3n, Goiru Kalea, 20500 Mondrag\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victor","family":"Acosta","sequence":"additional","affiliation":[{"name":"Group of Ultrasonic Resonators, Institute of Physical Technologies and Information, Spanish National Research Council CSIC, Serrano 144, 28006 Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Berganzo","sequence":"additional","affiliation":[{"name":"Department of Microsystems, IKERLAN, Jose Maria Arizmendiarreta 2, 20500 Mondrag\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adela","family":"Castillejo","sequence":"additional","affiliation":[{"name":"Group of Molecular Biology, Fundaci\u00f3n Hospital General Universitario de Elche, Camino de la Almazara 11, 03203 Elche, Alicante, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mounir","family":"Bouali","sequence":"additional","affiliation":[{"name":"Group of Microfludics, Politechnical University of Mondrag\u00f3n, Goiru Kalea, 20500 Mondrag\u00f3n, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0234-9188","authenticated-orcid":false,"given":"Jose","family":"Soto","sequence":"additional","affiliation":[{"name":"Group of Molecular Biology, Fundaci\u00f3n Hospital General Universitario de Elche, Camino de la Almazara 11, 03203 Elche, Alicante, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,5,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"5465","DOI":"10.1021\/ac049863r","article-title":"Pinched flow fractionation: Continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel","volume":"15","author":"Yamada","year":"2004","journal-title":"Anal. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1126\/science.1094567","article-title":"Continuous Particle Separation through Deterministic Lateral Displacement","volume":"304","author":"Huang","year":"2004","journal-title":"Science"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1039\/b509386d","article-title":"Hydrodynamic filtration for on-chip particle concentration and classification utilizing microfluidics","volume":"5","author":"Yamada","year":"2005","journal-title":"Lab Chip"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1021\/ac049037i","article-title":"Biomimetic designs of microfluidic device for auto-separation of leukocytes from the whole blood","volume":"77","author":"Shevkoplyas","year":"2005","journal-title":"Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1146\/annurev.bioeng.7.011205.135108","article-title":"Blood on a chip","volume":"7","author":"Toner","year":"2005","journal-title":"Rev. Annu. Biomed. Eng."},{"key":"ref_6","unstructured":"Berthier, J., and Silberzan, P. (2010). Microfluidics for Biotechnology, Artech House."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2005.12.037","article-title":"Microfluidics technology for manipulation and analysis of biological cells","volume":"560","author":"Yi","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1039\/b712784g","article-title":"Continuous flow separations in microfluidic devices","volume":"7","author":"Pamme","year":"2007","journal-title":"Lab Chip"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.chroma.2006.05.020","article-title":"Continuous separation of particles using a microfluidic device equipped with flow rate control valves","volume":"1127","author":"Sai","year":"2006","journal-title":"J. Chromatogr. A"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.aca.2006.11.057","article-title":"Continuous flow microfluidic device for cell separation, cell lysis and DNA purification","volume":"584","author":"Chen","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Nagrath, S., Sequist, L.V., Maheswaran, S., Bell, D.W., Irimia, D., Ulkus, L., Smith, M.R., Kwak, E.L., Digumarthy, S., Muzikansky, A., Ryan, P., Balis, U.J., Tompkins, R.G., Haber, D.A., and Toner, M. (2007). Isolation of rare circulating tumour cells in cancer patients by microchip technology. Nat. Lett., 450.","DOI":"10.1038\/nature06385"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1007\/s10544-009-9305-9","article-title":"Microdevice for the isolation and enumeration of cancer cells from blood","volume":"11","author":"Tan","year":"2009","journal-title":"Biomed. Microdevices"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"3249","DOI":"10.1007\/s00216-010-3721-9","article-title":"Label-free cell separation and sorting in microfluidic systems","volume":"397","author":"Gossett","year":"2010","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1007\/s11517-010-0611-4","article-title":"Microfluidics for cell separation","volume":"48","author":"Bhagat","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"319","DOI":"10.3390\/mi2030319","article-title":"Microfluidic Devices for Blood Fractionation","volume":"2","author":"Hou","year":"2011","journal-title":"Micromachines"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"056301","DOI":"10.1103\/PhysRevE.83.056301","article-title":"Separation of deformable particles in deterministic lateral displacement devices","volume":"83","author":"Quek","year":"2011","journal-title":"Phys. Rev. E"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1083\/jcb.201010021","article-title":"Circulating tumor cells: Approaches to isolation and characterization","volume":"192","author":"Yu","year":"2011","journal-title":"J. Cell Biol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.snb.2007.07.126","article-title":"Microfluidic Devices for Blood cell separation and collection based on crosflow filtration","volume":"130","author":"Chen","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"3163","DOI":"10.1039\/c3lc00052d","article-title":"Advances of lab-on-a-chip in isolation, detection and post-processing of circulating tumour cells","volume":"13","author":"Yu","year":"2013","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1038\/nature02144","article-title":"Microfluidic sorting in an optical lattice","volume":"426","author":"MacDonald","year":"2003","journal-title":"Nature"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"14322","DOI":"10.1364\/OE.15.014322","article-title":"Optofluidic trapping and transport on solid core waveguides within a microfluidic device","volume":"15","author":"Schmidt","year":"2007","journal-title":"Opt. Express"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1021\/ac034804j","article-title":"Dielectrophoretic Concentration and Separation of Live and Dead Bacteria in an Array of Insulators","volume":"76","author":"Simmons","year":"2004","journal-title":"Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1002\/elps.200500558","article-title":"Continuous separation of microparticles by size with Direct current-dielectrophoresis","volume":"27","author":"Kang","year":"2006","journal-title":"Electrophoresis"},{"key":"ref_24","first-page":"527","article-title":"Continuous Electrodeless Dielectrophoretic Separation in a Circular Channel","volume":"34","author":"Zhang","year":"2006","journal-title":"J. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4552","DOI":"10.1021\/ac070534j","article-title":"Electrophoretic and Dielectrophoretic Field Gradient Technique for Separating Bioparticles","volume":"79","author":"Pysher","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1002\/elps.200800373","article-title":"Isolation of rare cells from cell mixtures by Dielectrophoresis","volume":"30","author":"Gascoyne","year":"2009","journal-title":"Electrophoresis"},{"key":"ref_27","first-page":"73","article-title":"Ultrasonic manipulation of particles and cells","volume":"4","author":"Coakley","year":"1994","journal-title":"Bioseparation"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/S0301-5629(00)00212-X","article-title":"Plasma preparation from whole blood using ultrasound","volume":"26","author":"Cousins","year":"2000","journal-title":"Ultrasound Med. Biol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/S0925-4005(01)00553-6","article-title":"Force field particle filter combining ultrasound standing waves and laminar flow","volume":"75","author":"Hawkes","year":"2001","journal-title":"Sens. Actuators B Chem."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1021\/ac048394q","article-title":"Carrier Medium Exchange through Ultrasonic Particle Switching in Microfluidic Channels","volume":"77","author":"Petersson","year":"2005","journal-title":"Anal. Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.ultrasmedbio.2005.03.004","article-title":"Manipulation of cells using an ultrasonic pressure field","volume":"31","author":"Haake","year":"2005","journal-title":"Ultrasound Med. Biol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1562","DOI":"10.1088\/0960-1317\/16\/8\/017","article-title":"A micro-particle positioning technique combining an ultrasonic manipulator and a microgripper","volume":"16","author":"Neild","year":"2006","journal-title":"J. Micromech. Microeng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"P01012","DOI":"10.1088\/1742-5468\/2006\/01\/P01012","article-title":"Continuous particle size separation and size sorting using ultrasound in a Microchannel","volume":"2006","author":"Kapishnikov","year":"2006","journal-title":"J. Stat. Mech. Theory Exp."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1039\/B612064B","article-title":"Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip","volume":"6","author":"Wiklund","year":"2006","journal-title":"Lab Chip"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1039\/B601326K","article-title":"Chip integrated strategies for acoustic separation and manipulation of cells and particles","volume":"36","author":"Laurell","year":"2007","journal-title":"Chem. Soc. Rev."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1364\/OL.32.001144","article-title":"Fractionation of polydisperse colloid with acousto-optically generated potential energy landscapes","volume":"32","author":"Milne","year":"2007","journal-title":"Opt. Lett."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.ultras.2008.06.005","article-title":"Performance of a quarter-wavelength particle concentrator","volume":"48","author":"Townsend","year":"2008","journal-title":"Ultrasonics"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.ultras.2009.09.004","article-title":"Strategies for single particle manipulation using acoustic and flow fields","volume":"50","author":"Oberti","year":"2010","journal-title":"Ultrasonics"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"EL195","DOI":"10.1121\/1.3479976","article-title":"Manipulation of microparticles using phase-controllable ultrasonic standing wave","volume":"128","author":"Courtney","year":"2010","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1039\/b915522h","article-title":"Surface acoustic wave actuated cell sorting (SAWACS)","volume":"10","author":"Franke","year":"2010","journal-title":"Lab Chip"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2859","DOI":"10.1364\/BOE.2.002859","article-title":"Combined acoustic and optical trapping","volume":"2","author":"Thalhammer","year":"2011","journal-title":"Biomed. Opt. Express"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.ultras.2012.01.005","article-title":"Controlled Cell aggregation in a pulsed acoustic field","volume":"52","author":"Bazou","year":"2012","journal-title":"Ultrasonics"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"11105","DOI":"10.1073\/pnas.1209288109","article-title":"On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves","volume":"109","author":"Ding","year":"2012","journal-title":"Proc. Nat. Acad. Sci. USA"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1039\/C3LC41369A","article-title":"Acoustic Manipulation combined with other force fields","volume":"13","author":"Hill","year":"2013","journal-title":"Lab Chip"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.snb.2009.10.042","article-title":"A polymeric chip for micromanipulation and particle sorting by ultrasounds based on a multilayer configuration","volume":"144","author":"Fernandez","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_46","unstructured":"Gonz\u00e1lez, I., Fernandez, L.J., Gomez, T., Soto, J.L., Martin, A., and Berganzo, J. (2011, January 3\u20135). Ultrasonic extraction of circulating tumor cells from peripheral blood- a noninvasive method to keep the cells viable for later biomolecular analysis. Proceedings of the 2011 6th International Conference on Microtechnologies in Medicine and Biology (MMB2011), Luzern, Switzerland."},{"key":"ref_47","first-page":"8","article-title":"A lateral mode flow-through PMMA ultrasonic separator","volume":"5","author":"Harris","year":"2012","journal-title":"Int. J. Appl. Biomed. Eng."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"125006","DOI":"10.1088\/0960-1317\/23\/12\/125006","article-title":"Continuous acoustic separation in a thermoplastic microchannel","volume":"23","author":"Mueller","year":"2013","journal-title":"J. Micromech. Microeng."},{"key":"ref_49","first-page":"773","article-title":"On the forces acting on a small particle in an acoustical field in an ideal fluid","volume":"6","year":"1962","journal-title":"Sov. Phys. Dokl."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Mitra, S.K., and Chakraborty, S. (2012). Microfluidics and Nanofluidics Handbook, CRC Press. Chapter 8.","DOI":"10.1201\/b16864"},{"key":"ref_51","unstructured":"SU-8 2000. Available online: http:\/\/www.microchem.com\/pdf\/SU-82000DataSheet2000_5thru2015Ver4.pdf."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/5\/574\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:45:56Z","timestamp":1760215556000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/5\/574"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5,7]]},"references-count":51,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2015,5]]}},"alternative-id":["mi6050574"],"URL":"https:\/\/doi.org\/10.3390\/mi6050574","relation":{},"ISSN":["2072-666X"],"issn-type":[{"type":"electronic","value":"2072-666X"}],"subject":[],"published":{"date-parts":[[2015,5,7]]}}}