{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T23:00:01Z","timestamp":1776812401473,"version":"3.51.2"},"reference-count":21,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2015,5,22]],"date-time":"2015-05-22T00:00:00Z","timestamp":1432252800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Flow cytometry is a well-established diagnostic tool for cell counting and characterization. It utilizes fluorescence and scattered excitation light simultaneously emitted from cells passing an excitation laser focus to discriminate various cell types and estimate cell size. Here, we apply the principle of spatially modulated emission (SME) to fluorescently stained SUP-B15 cells as a model system for cancer cells and Marinococcus luteus as model for bacteria. We demonstrate that the experimental apparatus is able to detect these model cells and that the results are comparable to those obtained by a commercially available CASY\u00ae TT Counter. Furthermore, by examining the velocity distribution of the cells, we observe clear relationships between cell condition\/size and cell velocity. Thus, the cell velocity provides information comparable to the scatter signal in conventional flow cytometry. These results indicate that the SME technique is a promising method for simultaneous cell counting and viability characterization.<\/jats:p>","DOI":"10.3390\/mi6050634","type":"journal-article","created":{"date-parts":[[2015,5,26]],"date-time":"2015-05-26T04:16:36Z","timestamp":1432613796000},"page":"634-647","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Cell Size Discrimination Based on the Measurement of the Equilibrium Velocity in Rectangular Microchannels"],"prefix":"10.3390","volume":"6","author":[{"given":"Lisa","family":"Schott","sequence":"first","affiliation":[{"name":"Fraunhofer ICT-IMM, Carl-Zeiss-Str. 18-20, Mainz 55129, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Sommer","sequence":"additional","affiliation":[{"name":"Fraunhofer ICT-IMM, Carl-Zeiss-Str. 18-20, Mainz 55129, Germany"},{"name":"Technische Universit\u00e4t Darmstadt, Schlo\u00dfgartenstra\u00dfe 7, Darmstadt 64289, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joern","family":"Wittek","sequence":"additional","affiliation":[{"name":"Fraunhofer ICT-IMM, Carl-Zeiss-Str. 18-20, Mainz 55129, Germany"},{"name":"Technische Universit\u00e4t Darmstadt, Schlo\u00dfgartenstra\u00dfe 7, Darmstadt 64289, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Khaliun","family":"Myagmar","sequence":"additional","affiliation":[{"name":"Fraunhofer ICT-IMM, Carl-Zeiss-Str. 18-20, Mainz 55129, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Walther","sequence":"additional","affiliation":[{"name":"Technische Universit\u00e4t Darmstadt, Schlo\u00dfgartenstra\u00dfe 7, Darmstadt 64289, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Ba\u00dfler","sequence":"additional","affiliation":[{"name":"Fraunhofer ICT-IMM, Carl-Zeiss-Str. 18-20, Mainz 55129, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,5,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Shapiro, H.M. (2003). Practical Flow Cytometry, John Wiley and Sons. [4th ed.].","DOI":"10.1002\/0471722731"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1039\/C3LC51152A","article-title":"The intersection of flow cytometry with microfluidics and microfabrication","volume":"14","author":"Piyasena","year":"2014","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4511","DOI":"10.1002\/elps.200700620","article-title":"Recent advances in miniaturized microfluidic flow cytometry for clinical use","volume":"28","author":"Chung","year":"2007","journal-title":"Electrophoresis"},{"key":"ref_4","unstructured":"Bassler, M., Kiesel, P., Schmidt, O., and Johnson, N.M. (2008). Method and system implementing spatially modulated excitation or emission for particle characterization with enhanced sensitivity. (2008\/0181827 A1), U.S. Patent."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"041107","DOI":"10.1063\/1.3070536","article-title":"Spatially modulated fluorescence emission from moving particles","volume":"94","author":"Kiesel","year":"2009","journal-title":"Appl. Phys. Lett."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1039\/C3LC51336J","article-title":"The equilibrium velocity of spherical particles in rectangular microfluidic channels for size measurement","volume":"14","author":"Sommer","year":"2014","journal-title":"Lab Chip"},{"key":"ref_7","unstructured":"Brebbia, C.A., Hern\u00e1ndez, S., and Rahman, M. (2014). Advances in Fluid Mechanics X, WIT Press."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Wang, Y., Cao, L., Tang, S., Lou, K., Mao, P., Jin, X., Jiang, C., Xu, L., and Li, W. (2009). Int. J. Syst. Evol. Microbiol., 59, 2875\u20132879.","DOI":"10.1099\/ijs.0.009670-0"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"\u201cSketch of the experimental setup\u201d by Christian Sommer is licensed under CC BY 3.0, published by The Royal Society of Chemistry, Lab Chip 2014, 14, 2319\u20132326.","DOI":"10.1039\/C3LC51336J"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"\u201cSketch of the optical mask generated from the LABS 50\u201d by Christian Sommer is licensed under CC BY 3.0, published by The Royal Society of Chemistry, Lab Chip 2014, 14, 2319\u20132326.","DOI":"10.1039\/C3LC51336J"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"\u201cSketch of the fluidic chip\u201d by Christian Sommer is licensed under CC BY 3.0, published by The Royal Society of Chemistry, Lab Chip 2014, 14, 2319\u20132326.","DOI":"10.1039\/C3LC51336J"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"\u201cREM picture of the channel cross section in the fluidic chip\u201d by Christian Sommer is licensed under CC BY 3.0, published by The Royal Society of Chemistry, Lab Chip 2014, 14, 2319\u20132326.","DOI":"10.1039\/C3LC51336J"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1038\/189209a0","article-title":"Radial Particle Displacements in Poiseuille Flow of Suspensions","volume":"189","author":"Silberberg","year":"1961","journal-title":"Nature"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1017\/S0022112062001111","article-title":"Behaviour of macroscopic rigid spheres in Poiseuille flow Part 2. Experimental results and interpretation","volume":"14","author":"Silberberg","year":"1962","journal-title":"J. Fluid Mech."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/0095-8522(62)90056-9","article-title":"The flow of suspensions through tubes. I. Single spheres, rods, and discs","volume":"17","author":"Goldsmith","year":"1962","journal-title":"J. Colloid Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/0021-9797(66)90048-8","article-title":"The kinetics of flowing dispersions","volume":"22","author":"Karnis","year":"1966","journal-title":"J. Colloid Interface Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1039\/c0lc00595a","article-title":"Deformability-based cell classification and enrichment using inertial microfluidics","volume":"11","author":"Hur","year":"2011","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2757","DOI":"10.1002\/smll.201200588","article-title":"Inertial manipulation and transfer of microparticles across laminar fluid streams","volume":"8","author":"Gossett","year":"2012","journal-title":"Small"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1002\/aic.690160222","article-title":"Radialmigration of spherical particles in couette systems","volume":"16","author":"Halow","year":"1970","journal-title":"AIChE J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1039\/B919495A","article-title":"Sheathless inertial cell ordering for extremethroughput low cytometry","volume":"10","author":"Hur","year":"2010","journal-title":"Lab Chip"},{"key":"ref_21","unstructured":"Roche Diagnostics Corporation CASY Model TTC\u2014Cell Counter and Analyzer. Available online: http:\/\/lifescience.roche.com\/wcsstore\/RASCatalogAssetStore\/Articles\/05966680001_04.10_US.pdf."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/5\/634\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:46:51Z","timestamp":1760215611000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/5\/634"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5,22]]},"references-count":21,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2015,5]]}},"alternative-id":["mi6050634"],"URL":"https:\/\/doi.org\/10.3390\/mi6050634","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,5,22]]}}}