{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T01:29:00Z","timestamp":1795051740090,"version":"4.10.2"},"reference-count":18,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2015,6,30]],"date-time":"2015-06-30T00:00:00Z","timestamp":1435622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>We developed a minimally invasive glucose monitoring system that uses a microneedle to permeate the skin surface and a small hydrogel to accumulate interstitial fluid glucose. The measurement of glucose and sodium ion levels in the hydrogel is required for estimating glucose levels in blood; therefore, we developed a small, enzyme-fixed glucose sensor with a high-selectivity, all-solid-state, sodium ion-selective electrode (ISE) integrated into its design. The glucose sensor immobilized glucose oxidase showed a good correlation between the glucose levels in the hydrogels and the reference glucose levels (r &gt; 0.99), and exhibited a good precision (coefficient of variation = 2.9%, 0.6 mg\/dL). In the design of the sodium ISEs, we used the insertion material Na0.33MnO2 as the inner contact layer and DD16C5 exhibiting high Na+\/K+ selectivity as the ionophore. The developed sodium ISE exhibited high selectivity (\\( \\log \\,k^{pot}_{Na,K} = -2.8\\)) and good potential stability. The sodium ISE could measure 0.4 mM (10\u22123.4 M) sodium ion levels in the hydrogels containing 268 mM (10\u22120.57 M) KCl. The small integrated sensor (\u03d5 &lt; 10 mm) detected glucose and sodium ions in hydrogels simultaneously within 1 min, and it exhibited sufficient performance for use as a minimally invasive glucose monitoring system.<\/jats:p>","DOI":"10.3390\/mi6070831","type":"journal-article","created":{"date-parts":[[2015,6,30]],"date-time":"2015-06-30T11:40:13Z","timestamp":1435664413000},"page":"831-841","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["An Integrated Glucose Sensor with an All-Solid-State Sodium Ion-Selective Electrode for a Minimally Invasive Glucose Monitoring System"],"prefix":"10.3390","volume":"6","author":[{"given":"Junko","family":"Kojima","sequence":"first","affiliation":[{"name":"Central Research Laboratories, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe,  Hyogo 651-2271, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samiko","family":"Hosoya","sequence":"additional","affiliation":[{"name":"Central Research Laboratories, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe,  Hyogo 651-2271, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chihiro","family":"Suminaka","sequence":"additional","affiliation":[{"name":"Central Research Laboratories, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe,  Hyogo 651-2271, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyasu","family":"Hori","sequence":"additional","affiliation":[{"name":"Central Research Laboratories, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe,  Hyogo 651-2271, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiyuki","family":"Sato","sequence":"additional","affiliation":[{"name":"Central Research Laboratories, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe,  Hyogo 651-2271, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,6,30]]},"reference":[{"key":"ref_1","unstructured":"International Diabetes Federation (2014). Diabetes Atlas, International Diabetes Federation. [6th ed.]."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"DECODE Study Group (2003). Is the current definition for diabetes relevant to mortality risk from all causes and cardiovascular and noncardiovascular diseases?. Diabetes Care, 26, 688\u2013696.","DOI":"10.2337\/diacare.26.3.688"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1007\/s00125-004-1334-6","article-title":"Hyperglycaemia and mortality from all causes and from cardiovascular disease in five populations of Asian origin: The DECODA study","volume":"47","author":"Nakagami","year":"2004","journal-title":"Diabetologia"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1089\/dia.2011.0089","article-title":"A novel technique of glucose area under the curve monitoring with interstitial fluid","volume":"13","author":"Sato","year":"2011","journal-title":"Diabetes Technol. Ther."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1089\/dia.2011.0255","article-title":"A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology; evaluation of the accuracy and usefulness with oral glucose tolerance tests in subject with and without diabetes","volume":"14","author":"Sakaguchi","year":"2012","journal-title":"Diabetes Technol. Ther."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1111\/jdi.12096","article-title":"Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients","volume":"4","author":"Sakamoto","year":"2013","journal-title":"J. Diabetes Investig."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1260\/2040-2295.4.4.529","article-title":"Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system","volume":"4","author":"Kuranuki","year":"2013","journal-title":"J. Healthc. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0003-2670(00)85149-1","article-title":"A chemically-modified enzyme membrane electrode as an amperometric glucose sensor","volume":"148","author":"Yao","year":"1983","journal-title":"Anal. Chim. Acta"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/S0003-2670(01)82476-4","article-title":"An enzyme electrode for the amperometric determination of glucose","volume":"64","author":"Guilbault","year":"1973","journal-title":"Anal. Chim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1149\/1.2096713","article-title":"Electrochemical fabrication of amperometric microenzyme sensor","volume":"136","author":"Ikariyama","year":"1989","journal-title":"J. Electrochem. Soc."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1021\/ac00244a055","article-title":"Coated wire sodium- and potassium-selective electrodes based on bis(crown ether) compounds","volume":"54","author":"Tamura","year":"1982","journal-title":"Anal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/j.snb.2006.03.024","article-title":"Study of the potentiometric response towards sodium ions of Na0.44\u2212xMnO2 for the development of selective sodium ion sensors","volume":"120","author":"Sauvage","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1149\/05012.0279ecst","article-title":"Redox-active alkali insertion materials as inner contact layer in all-solid-state ion-selective electrodes","volume":"50","author":"Komaba","year":"2013","journal-title":"ECS Trans."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1021\/ac50058a010","article-title":"Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer","volume":"52","author":"Kamin","year":"1980","journal-title":"Anal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.snb.2009.01.002","article-title":"An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes","volume":"138","author":"Kong","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_16","unstructured":"Horiba, Ltd. Instruction Manuals (Sodium Ion Electrode 1512A-10C). Available online: http:\/\/www.horiba.com\/application\/material-property-characterization\/water-analysis\/water-quality-electrochemistry-instrumentation\/electrodes-accessories\/ion-electrodes\/details\/sodium-ion-electrode-1512a-10c-9563\/."},{"key":"ref_17","unstructured":"T.P.S. Pty Ltd. TPS uniPROBE Sodium (Na+) ISE. Available online: http:\/\/www.tps.com.au\/handbooks\/uniPROBE%20Sodium%20Instruction%20Sheet%20v2_2.pdf."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1351\/pac199466122527","article-title":"Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)","volume":"66","author":"Buck","year":"1994","journal-title":"Pure Appl. Chem."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/7\/831\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:48:36Z","timestamp":1760215716000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/7\/831"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6,30]]},"references-count":18,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2015,7]]}},"alternative-id":["mi6070831"],"URL":"https:\/\/doi.org\/10.3390\/mi6070831","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6,30]]}}}