{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:46:28Z","timestamp":1792028788419,"version":"4.4.0"},"reference-count":23,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2015,7,3]],"date-time":"2015-07-03T00:00:00Z","timestamp":1435881600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Research Foundation of Korea (NRF)","award":["2009-0083510"],"award-info":[{"award-number":["2009-0083510"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>In this study, a numerical investigation on mixing and flow structure in a serpentine microchannel with non-aligned input channels was performed. The non-aligned input channels generate a vortical flow, which is formed by incoming fluid streams through tangentially aligned channels. Mixing index was evaluated to measure the degree of mixing in the micromixer. Analyses of mixing and flow field were investigated for a Reynolds number range starting from 0.1 to 120. The vortical structure of the flow was analyzed to find  its effect on the mixing performance. Mixing of two working fluids in the micromixer was evaluated by using three-dimensional Navier\u2013Stokes equations. In order to compare the mixing performance between the serpentine micromixers with and without non-aligned inputs, the geometric parameters, such as cross-section areas of the input channels and main channel, height of the channel, axial length of the channel, and number of pitches, were kept constant. Pressure drops were also calculated with fixed axial length in both cases.<\/jats:p>","DOI":"10.3390\/mi6070842","type":"journal-article","created":{"date-parts":[[2015,7,3]],"date-time":"2015-07-03T16:19:37Z","timestamp":1435940377000},"page":"842-854","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["Mixing Performance of a Serpentine Micromixer with  Non-Aligned Inputs"],"prefix":"10.3390","volume":"6","author":[{"given":"Shakhawat","family":"Hossain","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, Incheon 402-751, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1046-3071","authenticated-orcid":false,"given":"Kwang-Yong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, Incheon 402-751, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,7,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1016\/j.addr.2013.08.002","article-title":"Microfluidic and lab-on-a-chip preparation routes for organic nanoparticles and vesicular systems for nanomedicine applications","volume":"65","author":"Capretto","year":"2013","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1039\/b921430e","article-title":"Applications of micromixing technology","volume":"135","author":"Jeong","year":"2010","journal-title":"Analyst"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2623","DOI":"10.1021\/ac0202435","article-title":"Micro total analysis systems. 1. Introduction, theory and technology","volume":"74","author":"Reyes","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Nguyen, N.-T., and Wu, Z. (2005). Micromixers\u2014A review. J. Micromech. Microeng., 15.","DOI":"10.1088\/0960-1317\/15\/2\/R01"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2479","DOI":"10.1016\/j.ces.2004.11.033","article-title":"Micromixers\u2014A review on passive and active mixing principles","volume":"60","author":"Hessel","year":"2005","journal-title":"Chem. Eng. Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.snb.2004.02.008","article-title":"Micro T-mixer as a rapid mixing micromixer","volume":"100","author":"Wong","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Thomas, S., Ameel, T., and Guilkey, J. (2010). Mixing kinematics of moderate Reynolds number flows in a T-channel. Phys. Fluids, 22.","DOI":"10.1063\/1.3283063"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.cej.2007.07.048","article-title":"Numerical and experimental investigations of liquid mixing in T-type micromixers","volume":"135","author":"Soleymani","year":"2008","journal-title":"Chem. Eng. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.cej.2012.01.046","article-title":"Effect of inlet conditions on the engulfment pattern in a T-shaped micro-mixer","volume":"185\u2013186","author":"Galletti","year":"2012","journal-title":"Chem. Eng. J."},{"key":"ref_10","first-page":"150","article-title":"Flow regimes in T-shaped micro-mixers Comp","volume":"76","author":"Salvetti","year":"2015","journal-title":"Chem. Eng. J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1002\/ceat.201100611","article-title":"Numerical study of split T-micromixers","volume":"35","author":"Roudgar","year":"2012","journal-title":"Chem. Eng. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.ces.2013.03.015","article-title":"Water\u2013ethanol mixing in T-shaped microdevices","volume":"9","author":"Orsi","year":"2013","journal-title":"Chem. Eng. Sci."},{"key":"ref_13","first-page":"1471","article-title":"Mixing of two miscible liquids in T-shaped microdevices","volume":"32","year":"2013","journal-title":"Chem. Eng. Trans."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.cej.2009.02.033","article-title":"Evaluation of the mixing performance of three passive micromixers","volume":"150","author":"Hossain","year":"2009","journal-title":"Chem. Eng. J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2217","DOI":"10.1002\/aic.11833","article-title":"A numerical study of mixing in a microchannel with circular mixing chambers","volume":"55","author":"Ansari","year":"2009","journal-title":"AIChE J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1088\/0960-1317\/15\/5\/006","article-title":"A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions","volume":"15","author":"Lin","year":"2005","journal-title":"J. Micromech. Microeng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.ces.2012.02.010","article-title":"Experimental study of flow regime and mixing in T-jets mixers","volume":"73","author":"Sultan","year":"2012","journal-title":"Chem. Eng. Sci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1016\/j.cej.2011.11.113","article-title":"Vortex micro T-mixer with non-aligned inputs","volume":"181\u2013182","author":"Ansari","year":"2012","journal-title":"Chem. Eng. J."},{"key":"ref_19","unstructured":"(2006). CFX-12.1, Solver Theory, ANSYS Inc."},{"key":"ref_20","unstructured":"Bird, R.B., Stewart, W.E., and Lightfoot, E.N. (1960). 1960 Transport Phenomenon, Wiley."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1002\/aic.690490305","article-title":"Laminar mixing in different inter-digital micromixers: II. Numerical simulations","volume":"49","author":"Hardt","year":"2003","journal-title":"AIChE J."},{"key":"ref_22","first-page":"147","article-title":"Enhancement of the SIMPLE method for predicting incompressible fluid flows","volume":"7","author":"Raithby","year":"1985","journal-title":"Numer. Heat Trans."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1080\/00986445.2013.841150","article-title":"Multi-Objective Optimization of a Passive Micromixer Based on Periodic Variation of Velocity Profile","volume":"202","author":"Afzal","year":"2015","journal-title":"Chem. Eng. Commu."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/7\/842\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:48:43Z","timestamp":1760215723000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/7\/842"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7,3]]},"references-count":23,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2015,7]]}},"alternative-id":["mi6070842"],"URL":"https:\/\/doi.org\/10.3390\/mi6070842","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,3]]}}}