{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T07:59:12Z","timestamp":1769068752485,"version":"3.49.0"},"reference-count":43,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2015,10,5]],"date-time":"2015-10-05T00:00:00Z","timestamp":1444003200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Combinatorial droplet microfluidic devices with programmable microfluidic valves have recently emerged as a viable approach for performing multiplexed experiments in microfluidic droplets. However, the serial operation in these devices restricts their throughput. To address this limitation, we present a parallelized combinatorial droplet device that enhances device throughput via droplet bifurcation, parallelized droplet fusion, and parallelized droplet detection. In this device, sample droplets split evenly at bifurcating Y-junctions before multiple independent reagent droplets are injected directly into the split sample droplets for robust droplet fusion. Finally, the fused sample and reagent droplets can be imaged in parallel via microscopy. The combination of these approaches enabled us to improve the throughput over traditional, serially-operated combinatorial droplet devices by 16-fold\u2014with ready potential for further enhancement. Given its current performance and prospect for future improvements, we believe the parallelized combinatorial droplet device has the potential to meet the demand as a flexible and cost-effective tool that can perform high throughput screening applications.<\/jats:p>","DOI":"10.3390\/mi6101434","type":"journal-article","created":{"date-parts":[[2015,10,5]],"date-time":"2015-10-05T10:26:41Z","timestamp":1444040801000},"page":"1490-1504","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Enhancing Throughput of Combinatorial Droplet Devices via Droplet Bifurcation, Parallelized Droplet Fusion, and Parallelized Detection"],"prefix":"10.3390","volume":"6","author":[{"given":"Kuangwen","family":"Hsieh","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helena","family":"Zec","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Polly","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tushar","family":"Rane","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tza-Huei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"},{"name":"Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,10,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3476","DOI":"10.1021\/ac400257c","article-title":"The potential impact of droplet microfluidics in biology","volume":"85","author":"Schneider","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1039\/C0CC02474K","article-title":"Droplet microfluidics: Recent developments and future applications","volume":"47","author":"Solvas","year":"2011","journal-title":"Chem. Commun."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3183","DOI":"10.1021\/ac902683t","article-title":"High-performance single cell genetic analysis using microfluidic emulsion generator arrays","volume":"82","author":"Zeng","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"7570","DOI":"10.1021\/ac201678g","article-title":"Multifunctional picoliter droplet manipulation platform and its application in single cell analysis","volume":"83","author":"Gu","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3341","DOI":"10.1039\/c2lc40537g","article-title":"Droplet microfluidics for amplification-free genetic detection of single cells","volume":"12","author":"Rane","year":"2012","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"8866","DOI":"10.1021\/ac4022067","article-title":"Droplet-based microfluidic platform for high-throughput, multi-parameter screening of photosensitizer activity","volume":"85","author":"Cho","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"14613","DOI":"10.1021\/ja0354566","article-title":"Millisecond kinetics on a microfluidic chip using nanoliters of reagents","volume":"125","author":"Song","year":"2003","journal-title":"J. Am. Chem. Soc."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5840","DOI":"10.1021\/ac900811y","article-title":"Measuring rapid enzymatic kinetics by electrochemical method in droplet-based microfluidic devices with pneumatic valves","volume":"81","author":"Han","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1039\/b403378g","article-title":"Multi-step synthesis of nanoparticles performed on millisecond time scale in a microfluidic droplet-based system","volume":"4","author":"Shestopalov","year":"2004","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"9543","DOI":"10.1021\/ja802157y","article-title":"Microfluidic fabrication of monodisperse biocompatible and biodegradable polymersomes with controlled permeability","volume":"130","author":"Shum","year":"2008","journal-title":"J. Am. Chem. Soc."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2161","DOI":"10.1039\/b809915b","article-title":"Microfluidic generation of microgels from synthetic and natural polymers","volume":"38","author":"Tumarkin","year":"2009","journal-title":"Chem. Soc. Rev."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"8604","DOI":"10.1021\/ac202028g","article-title":"High-throughput droplet digital PCR system for absolute quantitation of DNA copy number","volume":"83","author":"Hindson","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1039\/c1lc20126c","article-title":"Multiplex digital PCR: Breaking the one target per color barrier of quantitative PCR","volume":"11","author":"Zhong","year":"2011","journal-title":"Lab Chip"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1039\/C4LC01158A","article-title":"Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP)","volume":"15","author":"Rane","year":"2015","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2518","DOI":"10.1002\/anie.200804326","article-title":"Detection and analysis of low-abundance cell-surface biomarkers using enzymatic amplification in microfluidic droplets","volume":"48","author":"Joensson","year":"2009","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"19163","DOI":"10.1073\/pnas.1006888107","article-title":"High-throughput injection with microfluidics using picoinjectors","volume":"107","author":"Abate","year":"2010","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1039\/C4LC01162G","article-title":"Low-volume multiplexed proteolytic activity assay and inhibitor analysis through a pico-injector array","volume":"15","author":"Ng","year":"2015","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"19243","DOI":"10.1073\/pnas.0607502103","article-title":"Nanoliter microfluidic hybrid method for simultaneous screening and optimization validated with crystallization of membrane proteins","volume":"103","author":"Li","year":"2006","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1039\/b804911d","article-title":"Detecting bacteria and determining their susceptibility to antibiotics by stochastic confinement in nanoliter droplets using plug-based microfluidics","volume":"8","author":"Boedicker","year":"2008","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1039\/c2lc21019c","article-title":"Microfluidic platform for combinatorial synthesis in picolitre droplets","volume":"12","author":"Theberge","year":"2012","journal-title":"Lab Chip"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"3995","DOI":"10.1039\/c2lc40540g","article-title":"Automated generation of libraries of nL droplets","volume":"12","author":"Kaminski","year":"2012","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"14195","DOI":"10.1073\/pnas.0903542106","article-title":"Droplet microfluidic technology for single-cell high-throughput screening","volume":"106","author":"Brouzes","year":"2009","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1039\/b821803j","article-title":"Microvalve-actuated precise control of individual droplets in microfluidic devices","volume":"9","author":"Zeng","year":"2009","journal-title":"Lab Chip"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"233701","DOI":"10.1063\/1.3521283","article-title":"Valve-based microfluidic device for droplet on-demand operation and static assay","volume":"97","author":"Guo","year":"2010","journal-title":"Appl. Phys. Lett."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"3358","DOI":"10.1021\/ac103217p","article-title":"Creation of stepwise concentration gradient in picoliter droplets for parallel reactions of matrix metalloproteinase II and IX","volume":"83","author":"Jambovane","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.bios.2011.11.013","article-title":"Real-time luminescence-based colorimetric determination of double-strand DNA in droplet on demand","volume":"32","author":"Xiang","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3055","DOI":"10.1039\/c2lc40399d","article-title":"Microfluidic platform for on-demand generation of spatially indexed combinatorial droplets","volume":"12","author":"Zec","year":"2012","journal-title":"Lab Chip"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.talanta.2014.11.027","article-title":"Assembly-line manipulation of droplets in microfluidic platform for fluorescence encoding and simultaneous multiplexed DNA detection","volume":"134","author":"Chen","year":"2015","journal-title":"Talanta"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1950","DOI":"10.1021\/ac504330x","article-title":"A barcode-free combinatorial screening platform for matrix metalloproteinase screening","volume":"87","author":"Rane","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"054503","DOI":"10.1103\/PhysRevLett.92.054503","article-title":"Geometrically mediated breakup of drops in microfluidic devices","volume":"92","author":"Link","year":"2004","journal-title":"Phys. Rev. Lett."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"035303(R)","DOI":"10.1103\/PhysRevE.74.035303","article-title":"Droplet breakup in microfluidic junctions of arbitrary angles","volume":"74","author":"Tabeling","year":"2006","journal-title":"Phys. Rev. E"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2509","DOI":"10.1039\/c0lc00553c","article-title":"Tunable 3D droplet self-assembly for ultra-high-density digital micro-reactor arrays","volume":"11","author":"Hatch","year":"2011","journal-title":"Lab Chip"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"3838","DOI":"10.1039\/c1lc20561g","article-title":"1-million droplet array with wide-field fluorescence imaging for digital PCR","volume":"11","author":"Hatch","year":"2011","journal-title":"Lab Chip"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"034105","DOI":"10.1063\/1.4739072","article-title":"Behavior of liquid plugs at bifurcations in a microfluidic tree network","volume":"6","author":"Song","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"197","DOI":"10.3390\/mi4020197","article-title":"Active and precise control of microdroplet division using horizontal pneumatic valves in bifurcating microchannel","volume":"4","author":"Yoon","year":"2013","journal-title":"Micromachines"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s10404-014-1409-8","article-title":"Separation of magnetic microparticles in segmented flow using asymmetric splitting regimes","volume":"18","author":"Verbruggen","year":"2015","journal-title":"Microfluid. Nanofluid."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1126\/science.288.5463.113","article-title":"Monolithic microfabricated valves and pumps by multilayer soft lithography","volume":"288","author":"Unger","year":"2000","journal-title":"Science"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1038\/nprot.2013.046","article-title":"Single-cell analysis and sorting using droplet-based microfluidics","volume":"8","author":"Mazutis","year":"2013","journal-title":"Nat. Protoc."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH image to imageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.aca.2003.11.024","article-title":"Effects of viscosity on droplet formation and mixing in microfluidic channels","volume":"507","author":"Tice","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s10404-013-1239-0","article-title":"Effects of viscosity, interfacial tension, and flow geometry on droplet formation in a microfluidic T-junction","volume":"16","author":"Wehking","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1177\/2211068212455169","article-title":"A serial sample loading system: Interfacing multiwell plates with microfluidic devices","volume":"17","author":"Rane","year":"2012","journal-title":"J. Lab. Autom."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2397","DOI":"10.1039\/c3lc50072a","article-title":"Simple, distance-based measurement for paper analytical devices","volume":"13","author":"Cate","year":"2013","journal-title":"Lab Chip"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/10\/1434\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:49:40Z","timestamp":1760215780000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/10\/1434"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,5]]},"references-count":43,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2015,10]]}},"alternative-id":["mi6101434"],"URL":"https:\/\/doi.org\/10.3390\/mi6101434","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,5]]}}}