{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T18:01:58Z","timestamp":1791309718299,"version":"4.3.1"},"reference-count":118,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2015,11,13]],"date-time":"2015-11-13T00:00:00Z","timestamp":1447372800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003958","name":"Technologiestichting STW","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003958","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Even though droplet microfluidics has been developed since the early 1980s, the number of applications that have resulted in commercial products is still relatively small. This is partly due to an ongoing maturation and integration of existing methods, but possibly also because of the emergence of new techniques, whose potential has not been fully realized. This review summarizes the currently existing techniques for manipulating droplets in two-phase flow microfluidics. Specifically, very recent developments like the use of acoustic waves, magnetic fields, surface energy wells, and electrostatic traps and rails are discussed. The physical principles are explained, and (potential) advantages and drawbacks of different methods in the sense of versatility, flexibility, tunability and durability are discussed, where possible, per technique and per droplet operation: generation, transport, sorting, coalescence and splitting.<\/jats:p>","DOI":"10.3390\/mi6111455","type":"journal-article","created":{"date-parts":[[2015,11,16]],"date-time":"2015-11-16T05:40:47Z","timestamp":1447652447000},"page":"1768-1793","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":80,"title":["Droplet Manipulations in Two Phase Flow Microfluidics"],"prefix":"10.3390","volume":"6","author":[{"given":"Arjen","family":"Pit","sequence":"first","affiliation":[{"name":"Physics of Complex Fluids Group, MESA+ Institute, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mich\u00e8l","family":"Duits","sequence":"additional","affiliation":[{"name":"Physics of Complex Fluids Group, MESA+ Institute, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frieder","family":"Mugele","sequence":"additional","affiliation":[{"name":"Physics of Complex Fluids Group, MESA+ Institute, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,11,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1038\/nature05058","article-title":"The origins and the future of microfluidics","volume":"442","author":"Whitesides","year":"2006","journal-title":"Nature"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1039\/C4LC01122H","article-title":"Droplet-based microfluidics at the femtolitre scale","volume":"15","author":"Leman","year":"2015","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4674","DOI":"10.1039\/c3lc50957e","article-title":"Combinatorial generation of droplets by controlled assembly and coalescence","volume":"13","author":"Um","year":"2013","journal-title":"Lab Chip"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"054503","DOI":"10.1103\/PhysRevLett.92.054503","article-title":"Geometrically mediated breakup of drops in microfluidic devices","volume":"92","author":"Link","year":"2004","journal-title":"Phys. Rev. Lett."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4228","DOI":"10.1039\/c1lc20541b","article-title":"Combining rails and anchors with laser forcing for selective manipulation within 2D droplet arrays","volume":"11","author":"Fradet","year":"2011","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1039\/B813709A","article-title":"Static microdroplet arrays: A microfluidic device for droplet trapping, incubation and release for enzymatic and cell-based assays","volume":"9","author":"Huebner","year":"2009","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"034118","DOI":"10.1063\/1.4885079","article-title":"Coalescing drops in microfluidic parking networks: A multifunctional platform for drop-based microfluidics","volume":"8","author":"Bithi","year":"2014","journal-title":"Biomicrofluidics"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1016\/S1872-2040(11)60567-7","article-title":"Droplet Microfluidic Technology: Mirodroplets Formation and Manipulation","volume":"40","author":"Chen","year":"2012","journal-title":"Chin. J. Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2572","DOI":"10.3390\/ijms12042572","article-title":"Droplets Formation and Merging in Two-Phase Flow Microfluidics","volume":"12","author":"Gu","year":"2011","journal-title":"Int. J. Mol. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.1039\/c001191f","article-title":"Dynamics of microfluidic droplets","volume":"10","author":"Baroud","year":"2010","journal-title":"Lab Chip"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3439","DOI":"10.1039\/C5LC00614G","article-title":"The Poisson distribution and beyond: Methods for microfluidic droplet production and single cell encapsulation","volume":"15","author":"Collins","year":"2015","journal-title":"Lab Chip"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1039\/C0CC02474K","article-title":"Droplet microfluidics: Recent developments and future applications","volume":"47","author":"Solvas","year":"2011","journal-title":"Chem. Commun."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/JMEMS.2002.807467","article-title":"Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits","volume":"12","author":"Cho","year":"2003","journal-title":"J. Microelectromech. Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"23283","DOI":"10.3390\/s141223283","article-title":"Droplet Microfluidics for Chip-Based Diagnostics","volume":"14","author":"Kaler","year":"2014","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3377","DOI":"10.1039\/b904493k","article-title":"Fundamental challenges in electrowetting: From equilibrium shapes to contact angle saturation and drop dynamics","volume":"5","author":"Mugele","year":"2009","journal-title":"Soft Matter"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2146","DOI":"10.1039\/c2lc21147e","article-title":"Droplet microfluidics for high-throughput biological assays","volume":"12","author":"Guo","year":"2012","journal-title":"Lab Chip"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1007\/s00216-011-4984-5","article-title":"Droplet microfluidics for the study of artificial cells","volume":"400","author":"Takinoue","year":"2011","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"5846","DOI":"10.1002\/anie.200906653","article-title":"Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology","volume":"49","author":"Theberge","year":"2010","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1039\/C1LC20582J","article-title":"Surfactants in droplet-based microfluidics","volume":"12","author":"Baret","year":"2012","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"016601","DOI":"10.1088\/0034-4885\/75\/1\/016601","article-title":"Droplet based microfluidics","volume":"75","author":"Seemann","year":"2012","journal-title":"Rep. Prog. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"7336","DOI":"10.1002\/anie.200601554","article-title":"Reactions in droplets in microfluidic channels","volume":"45","author":"Song","year":"2006","journal-title":"Angew. Chem. Int. Ed. Engl."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1146\/annurev-anchem-062011-143028","article-title":"Digital Microfluidics","volume":"5","author":"Choi","year":"2012","journal-title":"Annu. Rev. Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Day, P., Manz, A., and Zhang, Y. (2012). Microdroplet Technology: Principles and Emerging Applications in Biology and Chemisty, Springer.","DOI":"10.1007\/978-1-4614-3265-4"},{"key":"ref_24","unstructured":"Bruus, H. (2008). Theoretical Microfluidics, Oxford University Press."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1039\/B815002H","article-title":"Hydrodynamic resistance of single confined moving drops in rectangular microchannels","volume":"9","author":"Vanapalli","year":"2009","journal-title":"Lab Chip"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1039\/c3lc51121a","article-title":"Electrostatic potential wells for on-demand drop manipulation in microchannels","volume":"14","author":"Pit","year":"2014","journal-title":"Lab Chip"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"035003","DOI":"10.1088\/0960-1317\/20\/3\/035003","article-title":"Droplet merging in a straight microchannel using droplet size or viscosity difference","volume":"20","author":"Jin","year":"2010","journal-title":"J. Micromech. Microeng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"6761","DOI":"10.1021\/ac034663l","article-title":"On-chip hydrodynamic chromatography separation and detection of nanoparticles and biomolecules","volume":"75","author":"Blom","year":"2003","journal-title":"Anal. Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"5122","DOI":"10.1039\/C5SM01077B","article-title":"Collective dynamics of non-coalescing and coalescing droplets in microfluidic parking networks","volume":"11","author":"Bithi","year":"2015","journal-title":"Soft Matter"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"4096","DOI":"10.1039\/c3lc50347j","article-title":"Microfluidic traps for hard-wired operations on droplets","volume":"13","author":"Korczyk","year":"2013","journal-title":"Lab Chip"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"124501","DOI":"10.1103\/PhysRevLett.107.124501","article-title":"Trapping microfluidic drops in wells of surface energy","volume":"107","author":"Dangla","year":"2011","journal-title":"Phys. Rev. Lett."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"054006","DOI":"10.1103\/PhysRevApplied.3.054006","article-title":"Breaking Anchored Droplets in a Microfluidic Hele-Shaw Cell","volume":"3","author":"Amselem","year":"2015","journal-title":"Phys. Rev. Appl."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1039\/C0LC00104J","article-title":"Rails and anchors: Guiding and trapping droplet microreactors in two dimensions","volume":"11","author":"Abbyad","year":"2011","journal-title":"Lab Chip"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1073\/pnas.1209186110","article-title":"Droplet microfluidics driven by gradients of confinement","volume":"110","author":"Dangla","year":"2013","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3936","DOI":"10.1039\/c2lc40456g","article-title":"Fusion and sorting of two parallel trains of droplets using a railroad-like channel network and guiding tracks","volume":"12","author":"Xu","year":"2012","journal-title":"Lab Chip"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1002\/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO;2-C","article-title":"Fabrication of microfluidic systems in poly(dimethylsiloxane)","volume":"21","author":"McDonald","year":"2000","journal-title":"Electrophoresis"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"4974","DOI":"10.1021\/ac980656z","article-title":"Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)","volume":"70","author":"Duffy","year":"1998","journal-title":"Anal. Chem."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1126\/science.288.5463.113","article-title":"Monolithic microfabricated valves and pumps by multilayer soft lithography","volume":"288","author":"Unger","year":"2000","journal-title":"Science"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"203509","DOI":"10.1063\/1.3431281","article-title":"Microfluidic sorting with high-speed single-layer membrane valves","volume":"96","author":"Abate","year":"2010","journal-title":"Appl. Phys. Lett."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s10404-009-0412-y","article-title":"Predictive model on micro droplet generation through mechanical cutting","volume":"7","author":"Lee","year":"2009","journal-title":"Microfluid. Nanofluid."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1039\/b821803j","article-title":"Microvalve-actuated precise control of individual droplets in microfluidic devices","volume":"9","author":"Zeng","year":"2009","journal-title":"Lab Chip"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"3358","DOI":"10.1021\/ac103217p","article-title":"Creation of Stepwise Concentration Gradient in Picoliter Droplets for Parallel Reactions of Matrix Metalloproteinase II and IX","volume":"83","author":"Jambovane","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"7665","DOI":"10.1073\/pnas.1106752109","article-title":"A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities","volume":"109","author":"Leung","year":"2012","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2410","DOI":"10.1002\/elps.201100167","article-title":"Dielectrophoresis in microfluidics technology","volume":"32","author":"Cetin","year":"2011","journal-title":"Electrophoresis"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"022811","DOI":"10.1063\/1.3456626","article-title":"Review article-dielectrophoresis: Status of the theory, technology, and applications","volume":"4","author":"Pethig","year":"2010","journal-title":"Biomicrofluidics"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"024104","DOI":"10.1063\/1.2164911","article-title":"Dielectrophoretic manipulation of drops for high-speed microfluidic sorting devices","volume":"88","author":"Ahn","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"R705","DOI":"10.1088\/0953-8984\/17\/28\/R01","article-title":"Electrowetting: From basics to applications","volume":"17","author":"Mugele","year":"2005","journal-title":"J. Phys. Condens. Matter"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2832","DOI":"10.1039\/c2lc21036c","article-title":"Use of electrowetting to measure dynamic interfacial tensions of a microdrop","volume":"12","author":"Wennink","year":"2012","journal-title":"Lab Chip"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"7717","DOI":"10.1039\/C5SM01511A","article-title":"On the shape of a droplet in a wedge: New insight from electrowetting","volume":"11","author":"Baratian","year":"2015","journal-title":"Soft Matter"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"4437","DOI":"10.1021\/la025616b","article-title":"On the relationship of dielectrophoresis and electrowetting","volume":"18","author":"Jones","year":"2002","journal-title":"Langmuir"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1039\/b801516c","article-title":"All-terrain droplet actuation","volume":"8","author":"Abdelgawad","year":"2008","journal-title":"Lab Chip"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"4416","DOI":"10.1039\/c2lc40647k","article-title":"Droplet sensing by measuring the capacitance between coplanar electrodes in a digital microfluidic system","volume":"12","author":"Bhattacharjee","year":"2012","journal-title":"Lab Chip"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1038\/nature01988","article-title":"Video-speed electronic paper based on electrowetting","volume":"425","author":"Hayes","year":"2003","journal-title":"Nature"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"3305","DOI":"10.1039\/c2lc40273d","article-title":"Programmable large area digital microfluidic array with integrated droplet sensing for bioassays","volume":"12","author":"Hadwen","year":"2012","journal-title":"Lab Chip"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/j.jcis.2011.07.014","article-title":"High-speed droplet actuation on single-plate electrode arrays","volume":"362","author":"Banerjee","year":"2011","journal-title":"J. Colloid Interface Sci."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1016\/j.mejo.2014.05.016","article-title":"Polydimethylsiloxane material as hydrophobic and insulating layer in electrowetting-on-dielectric systems","volume":"45","author":"Caputo","year":"2014","journal-title":"Microelectron. J."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"193513","DOI":"10.1063\/1.4807118","article-title":"DropBot: An open-source digital microfluidic control system with precise control of electrostatic driving force and instantaneous drop velocity measurement","volume":"102","author":"Fobel","year":"2013","journal-title":"Appl. Phys. Lett."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"044116","DOI":"10.1063\/1.4928452","article-title":"High-throughput sorting of drops in microfluidic chips using electric capacitance","volume":"9","author":"Pit","year":"2015","journal-title":"Biomicrofluidics"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"2556","DOI":"10.1002\/anie.200503540","article-title":"Electric control of droplets in microfluidic devices","volume":"45","author":"Link","year":"2006","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"024113","DOI":"10.1063\/1.3604393","article-title":"On-demand electrostatic droplet charging and sorting","volume":"5","author":"Ahn","year":"2011","journal-title":"Biomicrofluidics"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.snb.2014.12.057","article-title":"A microfluidic electrostatic separator based on pre-charged droplets","volume":"210","author":"Rao","year":"2015","journal-title":"Sens. Actuators B Chem."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"10765","DOI":"10.1002\/anie.201203862","article-title":"Programmable Magnetic Tweezers and Droplet Microfluidic Device for High-Throughput Nanoliter Multi-Step Assays","volume":"51","author":"Begolo","year":"2012","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"2344","DOI":"10.1039\/c3lc50353d","article-title":"A low cost and high throughput magnetic bead-based immuno-agglutination assay in confined droplets","volume":"13","author":"Teste","year":"2013","journal-title":"Lab Chip"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s10404-015-1556-6","article-title":"Selective handling of droplets in a microfluidic device using magnetic rails","volume":"19","author":"Teste","year":"2015","journal-title":"Microfluid. Nanofluid."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1038\/nphys3341","article-title":"Synchronous universal droplet logic and control","volume":"11","author":"Katsikis","year":"2015","journal-title":"Nat. Phys."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1063\/1.1754276","article-title":"Direct Piezoelectric Coupling to Surface Elastic Waves","volume":"7","author":"White","year":"1965","journal-title":"Appl. Phys. Lett."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1039\/B716321E","article-title":"Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)","volume":"8","author":"Shi","year":"2008","journal-title":"Lab Chip"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"2625","DOI":"10.1039\/b906819h","article-title":"Surface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices","volume":"9","author":"Franke","year":"2009","journal-title":"Lab Chip"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"3030","DOI":"10.1039\/C5LC00468C","article-title":"Microfluidic plug steering using surface acoustic waves","volume":"15","author":"Sesen","year":"2015","journal-title":"Lab Chip"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"3325","DOI":"10.1039\/C4LC00456F","article-title":"Microfluidic on-demand droplet merging using surface acoustic waves","volume":"14","author":"Sesen","year":"2014","journal-title":"Lab Chip"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1039\/C4LC01453G","article-title":"Planar microfluidic drop splitting and merging","volume":"15","author":"Collignon","year":"2015","journal-title":"Lab Chip"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"3710","DOI":"10.1039\/C4LC00588K","article-title":"Sorting drops and cells with acoustics: Acoustic microfluidic fluorescence-activated cell sorter","volume":"14","author":"Schmid","year":"2014","journal-title":"Lab Chip"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"6482","DOI":"10.1364\/AO.54.006482","article-title":"Imaging local acoustic pressure in microchannels","volume":"54","author":"Oever","year":"2015","journal-title":"Appl. Opt."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"8122","DOI":"10.1039\/C4SM01453G","article-title":"Droplet manipulation in a microfluidic chamber with acoustic radiation pressure and acoustic streaming","volume":"10","author":"Cheung","year":"2014","journal-title":"Soft Matter"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"2896","DOI":"10.1039\/C5LC00083A","article-title":"Microfluidic droplet handling by bulk acoustic wave (BAW) acoustophoresis","volume":"15","author":"Leibacher","year":"2015","journal-title":"Lab Chip"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1364\/OL.11.000288","article-title":"Observation of a Single-Beam Gradient Force Optical Trap for Dielectric Particles","volume":"11","author":"Ashkin","year":"1986","journal-title":"Opt. Lett."},{"key":"ref_77","first-page":"20120265","article-title":"Pushing, pulling and twisting liquid crystal systems: Exploring new directions with laser manipulation","volume":"371","author":"Sanders","year":"2013","journal-title":"Philos. Trans. A"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0030-4018(02)01524-9","article-title":"Dynamic holographic optical tweezers","volume":"207","author":"Curtis","year":"2002","journal-title":"Opt. Commun."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"161111","DOI":"10.1063\/1.2912031","article-title":"Quantitative force mapping of an optical vortex trap","volume":"92","author":"Zhao","year":"2008","journal-title":"Appl. Phys. Lett."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s10404-013-1263-0","article-title":"Optical separation of droplets on a microfluidic platform","volume":"16","author":"Jung","year":"2014","journal-title":"Microfluid. Nanofluid."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1039\/b702472j","article-title":"An optical toolbox for total control of droplet microfluidics","volume":"7","author":"Baroud","year":"2007","journal-title":"Lab Chip"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1039\/c0lc00555j","article-title":"High-speed droplet generation on demand driven by pulse laser-induced cavitation","volume":"11","author":"Park","year":"2011","journal-title":"Lab Chip"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"4163","DOI":"10.1103\/PhysRevLett.86.4163","article-title":"Dynamic pattern formation in a vesicle-generating microfluidic device","volume":"86","author":"Thorsen","year":"2001","journal-title":"Phys. Rev. Lett."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.ces.2011.10.048","article-title":"Study on the mechanism of droplet formation in T-junction microchannel","volume":"69","author":"Li","year":"2012","journal-title":"Chem. Eng. Sci."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1063\/1.1537519","article-title":"Formation of dispersions using \u201cflow focusing\u201d in microchannels","volume":"82","author":"Anna","year":"2003","journal-title":"Appl. Phys. Lett."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"3045","DOI":"10.1016\/j.ces.2004.04.006","article-title":"Drop formation in a co-flowing ambient fluid","volume":"59","author":"Cramer","year":"2004","journal-title":"Chem. Eng. Sci."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"104502","DOI":"10.1103\/PhysRevLett.99.104502","article-title":"Stability of a jet in confined pressure-driven biphasic flows at low reynolds numbers","volume":"99","author":"Guillot","year":"2007","journal-title":"Phys. Rev. Lett."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1557\/mrs2007.145","article-title":"Dripping, jetting, drops, and wetting: The magic of microfluidics","volume":"32","author":"Utada","year":"2007","journal-title":"MRS Bull."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"082109","DOI":"10.1063\/1.4892949","article-title":"Dynamics of step-emulsification: From a single to a collection of emulsion droplet generators","volume":"26","author":"Mittal","year":"2014","journal-title":"Phys. Fluids"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1039\/C4LC01289E","article-title":"Step-emulsification in a microfluidic device","volume":"15","author":"Li","year":"2015","journal-title":"Lab Chip"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"114003","DOI":"10.1088\/0022-3727\/46\/11\/114003","article-title":"The physical mechanisms of step emulsification","volume":"46","author":"Dangla","year":"2013","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"4787","DOI":"10.1038\/srep04787","article-title":"The Microfluidic Jukebox","volume":"4","author":"Tan","year":"2014","journal-title":"Sci. Rep."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"011101","DOI":"10.1063\/1.3570666","article-title":"A microfluidic platform for on-demand formation and merging of microdroplets using electric control","volume":"5","author":"Gu","year":"2011","journal-title":"Biomicrofluidics"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1039\/b110474h","article-title":"Electrowetting-based actuation of droplets for integrated microfluidics","volume":"2","author":"Pollack","year":"2002","journal-title":"Lab Chip"},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"3225","DOI":"10.1039\/c3lc50372k","article-title":"Surface acoustic waves for on-demand production of picoliter droplets and particle encapsulation","volume":"13","author":"Collins","year":"2013","journal-title":"Lab Chip"},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"024103","DOI":"10.1063\/1.3699972","article-title":"Novel on-demand droplet generation for selective fluid sample extraction","volume":"6","author":"Lin","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"115005","DOI":"10.1088\/0960-1317\/18\/11\/115005","article-title":"On-demand liquid-in-liquid droplet metering and fusion utilizing pneumatically actuated membrane valves","volume":"18","author":"Lin","year":"2008","journal-title":"J. Micromech. Microeng."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"5468","DOI":"10.1021\/ac400548d","article-title":"An On-Chip, Multichannel Droplet Sorter Using Standing Surface Acoustic Waves","volume":"85","author":"Li","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.1039\/b902504a","article-title":"Fluorescence-activated droplet sorting (FADS): Efficient microfluidic cell sorting based on enzymatic activity","volume":"9","author":"Baret","year":"2009","journal-title":"Lab Chip"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1039\/b819267g","article-title":"Negative DEP traps for single cell immobilisation","volume":"9","author":"Thomas","year":"2009","journal-title":"Lab Chip"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1063\/1.1308534","article-title":"Electrowetting-based actuation of liquid droplets for microfluidic applications","volume":"77","author":"Pollack","year":"2000","journal-title":"Appl.Phys. Lett."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"024501","DOI":"10.1103\/PhysRevLett.100.024501","article-title":"Decompressing emulsion droplets favors coalescence","volume":"100","author":"Bremond","year":"2008","journal-title":"Phys. Rev. Lett."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1007\/s10404-014-1522-8","article-title":"In situ seriate droplet coalescence under an optical force","volume":"18","author":"Jung","year":"2015","journal-title":"Microfluid. Nanofluid."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1021\/ac061586w","article-title":"Vortex-trap-induced fusion of femtoliter-volume aqueous droplets","volume":"79","author":"Lorenz","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_105","first-page":"1059","article-title":"Prolonged Shelf Stability and Biocompatibility of a Concentrated Injectable Fluorocarbon Emulsion","volume":"20","author":"Follana","year":"1992","journal-title":"Biomater. Artif. Cells Immobil. Biotechnol."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1039\/C4LC01285B","article-title":"Chemically induced coalescence in droplet-based microfluidics","volume":"15","author":"Akartuna","year":"2015","journal-title":"Lab Chip"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1002\/elps.201300179","article-title":"High-throughput deterministic single-cell encapsulation and droplet pairing, fusion, and shrinkage in a single microfluidic device","volume":"35","author":"Schoeman","year":"2014","journal-title":"Electrophoresis"},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"4809","DOI":"10.1039\/c2lc21155f","article-title":"Pressure driven digital logic in PDMS based microfluidic devices fabricated by multilayer soft lithography","volume":"12","author":"Devaraju","year":"2012","journal-title":"Lab Chip"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1126\/science.1136907","article-title":"Microfluidic bubble logic","volume":"315","author":"Prakash","year":"2007","journal-title":"Science"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"3069","DOI":"10.1039\/c0lc00219d","article-title":"A microdroplet-based shift register","volume":"10","author":"Zagnoni","year":"2010","journal-title":"Lab Chip"},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"9951","DOI":"10.1038\/srep09951","article-title":"Droplet-interface-bilayer assays in microfluidic passive networks","volume":"5","author":"Schlicht","year":"2015","journal-title":"Sci. Rep."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"9127","DOI":"10.1021\/la030090w","article-title":"Formation of droplets and mixing in multiphase microfluidics at low values of the Reynolds and the capillary numbers","volume":"19","author":"Tice","year":"2003","journal-title":"Langmuir"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"14195","DOI":"10.1073\/pnas.0903542106","article-title":"Droplet microfluidic technology for single-cell high-throughput screening","volume":"106","author":"Brouzes","year":"2009","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1002\/anie.200390203","article-title":"A microfluidic system for controlling reaction networks in time","volume":"42","author":"Song","year":"2003","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1039\/B307628H","article-title":"Rapid droplet mixers for digital microfluidic systems","volume":"3","author":"Paik","year":"2003","journal-title":"Lab Chip"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"154102","DOI":"10.1063\/1.3645621","article-title":"Controlling flow patterns in oscillating sessile drops by breaking azimuthal symmetry","volume":"99","author":"Mampallil","year":"2011","journal-title":"Appl. Phys. Lett."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"8805","DOI":"10.1021\/ac3020627","article-title":"Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays","volume":"84","author":"Ng","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"3677","DOI":"10.1039\/C5LC00651A","article-title":"A programmable microfluidic static droplet array for droplet generation, transportation, fusion, storage, and retrieval","volume":"15","author":"Jin","year":"2015","journal-title":"Lab Chip"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/11\/1455\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:52:05Z","timestamp":1760215925000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/11\/1455"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,13]]},"references-count":118,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2015,11]]}},"alternative-id":["mi6111455"],"URL":"https:\/\/doi.org\/10.3390\/mi6111455","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,13]]}}}