{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T20:53:05Z","timestamp":1793307185177,"version":"4.5.0"},"reference-count":13,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2015,12,8]],"date-time":"2015-12-08T00:00:00Z","timestamp":1449532800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>This paper demonstrates and compares different experimental techniques utilized to estimate the quality factor (Q) and natural frequency from non-contact measurements of Microelectromechanical Systems (MEMS) motions. The relative merits of those techniques are contrasted in Q factor estimation for a cantilever beam MEMS actuator, operated in three configurations: free standing, arc-shaped, and s-shaped. It is found that damping estimation techniques that seek to minimize the deviation between the response of an \u201cassumed\u201d linear oscillator and the measured time-history of the motions are superior to those traditional techniques, such as logarithmic decrement and half-power bandwidth. Further, it is found that Q increases three-fold as the actuator contact with the substrate evolves from a line to an area.<\/jats:p>","DOI":"10.3390\/mi6121466","type":"journal-article","created":{"date-parts":[[2015,12,9]],"date-time":"2015-12-09T15:21:41Z","timestamp":1449674501000},"page":"1935-1945","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Measuring the Quality Factor in MEMS Devices"],"prefix":"10.3390","volume":"6","author":[{"given":"Savas","family":"Ozdemir","sequence":"first","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sohail","family":"Akhtar","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ozgur","family":"Gunal","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmoud","family":"Khater","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Resul","family":"Saritas","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3709-7593","authenticated-orcid":false,"given":"Eihab","family":"Abdel-Rahman","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa","family":"Yavuz","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,12,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Castellini, P., Marchetti, B., and Tomasini, E. (2002, January 18). Scanning laser doppler vibrometer for dynamic measurements on small microsystems. Proceedings of Fifth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, Ancona, Italy.","DOI":"10.1117\/12.468137"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"055501","DOI":"10.1088\/0957-0233\/22\/5\/055501","article-title":"Measurement and modelling of non-contact atomic force microscope cantilever properties from ultra-high vacuum to normal pressure conditions","volume":"22","author":"Temmen","year":"2011","journal-title":"J. Meas. Sci. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1109\/JMEMS.2013.2286199","article-title":"Estimating damping in microresonators by measuring thermomechanical noise using laser doppler vibrometry","volume":"23","author":"Labuda","year":"2014","journal-title":"J. MEMS"},{"key":"ref_4","unstructured":"Laser Doppler Vibrometer, Polytec Inc. Available online: www. polytec.com."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Marioli, D., Sardini, E., Serpelloni, M., And\u00f2, B., Baglio, S., Savalli, N., and Trigona, C. (2009, January 5\u20137). Hybrid telemetric MEMS for high temperature measurements into harsh industrial environments. Proceedings of I2MTC 2009 International Instrumentation and Measurement Technology Conference, Singapore.","DOI":"10.1109\/IMTC.2009.5168678"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"And\u00f3, B., Baglio, S., Pitrone, N., Savalli, N., and Trigona, C. (2008, January 12\u201315). Bent beam MEMS temperature sensors for contactless measurements in harsh environments. Proceedings of IEEE Instrumentation and Measurement Technology Conference, Victoria, Canada.","DOI":"10.1109\/IMTC.2008.4547363"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1163\/15685610360554393","article-title":"Mechanics of adhesion in MEMS\u2014A review","volume":"17","author":"Zhao","year":"2003","journal-title":"J. Adhesion Sci. Technol."},{"key":"ref_8","unstructured":"Inman, D.J. (1994). Engineering Vibrations, Prentice Hall."},{"key":"ref_9","unstructured":"Brincker, R., Ventura, C.E., and Andersen, P. (February, January ). Damping estimation by frequency domain decomposition. Proceedings of the SPIE 19th International Modal Analysis Conference, Orlando, FL, USA."},{"key":"ref_10","unstructured":"Heiman, G.W. (2003). Basic Statistics, Houghton Mifflin Company."},{"key":"ref_11","unstructured":"Kennedy, J., and Eberhart, R. (December, January 27). Particle swarm optimization. Proceedings of IEEE International Conference on Neural Networks, Perth, Australia."},{"key":"ref_12","unstructured":"Kennedy, J., and Eberhart, R.C. (1999). New Ideas in Optimization, McGraw-Hill Ltd."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Akhtar, S., Abdel-Rahman, E., and Ahmad, A. (2014, January 7\u20139). A New Fitness Based Adaptive Parameter Particle Swarm Optimizer. Proceedings of The 11th Conference on Computer and Robot Vision: CRV, Montreal, QC, Canada.","DOI":"10.1109\/CRV.2014.52"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/12\/1466\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:53:36Z","timestamp":1760216016000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/12\/1466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,8]]},"references-count":13,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["mi6121466"],"URL":"https:\/\/doi.org\/10.3390\/mi6121466","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,8]]}}}