{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:25:59Z","timestamp":1760243159297,"version":"build-2065373602"},"reference-count":25,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2015,12,10]],"date-time":"2015-12-10T00:00:00Z","timestamp":1449705600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61172081"],"award-info":[{"award-number":["61172081"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004731","name":"Natural Science Foundation of Zhejiang Province","doi-asserted-by":"publisher","award":["LZ13F010001"],"award-info":[{"award-number":["LZ13F010001"]}],"id":[{"id":"10.13039\/501100004731","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>An in-plane liquid gradient index (L-GRIN) microlens is designed for dynamically adjusting the beam focusing. The ethylene glycol solution (core liquid) withde-ionized (DI) water (cladding liquid) is co-injected into the lens chamber to form a gradient refractive index profile. The influences of the diffusion coefficient, mass fraction of ethylene glycol and flow rate of liquids on the refractive index profile of L-GRIN microlens are analyzed, and the finite element method and ray tracing method are used to simulate the convection-diffusion process and beam focusing process, which is helpful for the prediction of focusing effects and manipulation of the device. It is found that not only the focal length but the focal spot of the output beam can be adjusted by the diffusion coefficient, mass fraction and flow rate of liquids. The focal length of the microlens varies from 942 to 11 \u03bcm when the mass fraction of the ethylene glycol solution varies from 0.05 to 0.4, and the focal length changes from 127.1 to 8 \u03bcm by varying the flow rate of the core liquid from 0.5 \u00d7 103 to 5 \u00d7 103 pL\/s when there is no slip between the core and cladding inlet. The multiple adjustable microlens with a simple planar microfluidic structure can be used in integrated optics and lab-on-chip systems.<\/jats:p>","DOI":"10.3390\/mi6121469","type":"journal-article","created":{"date-parts":[[2015,12,14]],"date-time":"2015-12-14T02:57:29Z","timestamp":1450061849000},"page":"1984-1995","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Liquid Gradient Refractive Index Microlens for Dynamically Adjusting the Beam Focusing"],"prefix":"10.3390","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9745-8565","authenticated-orcid":false,"given":"Zichun","family":"Le","sequence":"first","affiliation":[{"name":"College of Sciences, Zhejiang University of Technology, Hangzhou 310023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunli","family":"Sun","sequence":"additional","affiliation":[{"name":"College of Sciences, Zhejiang University of Technology, Hangzhou 310023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7919-5060","authenticated-orcid":false,"given":"Ying","family":"Du","sequence":"additional","affiliation":[{"name":"College of Sciences, Zhejiang University of Technology, Hangzhou 310023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,12,10]]},"reference":[{"key":"ref_1","first-page":"74","article-title":"Optofluidics emerges from the laboratory","volume":"42","author":"Erickson","year":"2008","journal-title":"Photon. Spectra"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1039\/b822982a","article-title":"A tunable optofluidic microlens based on gradient refractive index","volume":"9","author":"Mao","year":"2009","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"061106","DOI":"10.1063\/1.2266887","article-title":"Demonstration of two-dimensional fluidic lens for integration into microfluidic flow cytometers","volume":"89","author":"Godin","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1039\/B400663A","article-title":"Measurements of scattered light on a microchip flow cytometer with integrated polymer based optical elements","volume":"4","author":"Wang","year":"2004","journal-title":"Lab Chip"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"5057","DOI":"10.1039\/c2lc40515f","article-title":"Time encoded multicolour fluorescence detection in a microfluidic flow cytometer","volume":"12","author":"Martini","year":"2012","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1039\/b708861b","article-title":"Tailoring the transmission of liquid-core waveguides for wavelength filtering on a chip","volume":"7","author":"Yin","year":"2007","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3728","DOI":"10.1039\/c2lc40700k","article-title":"Dual-core optofluidic chip for independent particle detection an tunable spectral filtering","volume":"12","author":"Ozcelik","year":"2012","journal-title":"Lab Chip"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1063\/1.1779954","article-title":"Variable-focus liquid lens for miniature cameras","volume":"85","author":"Kuiper","year":"2004","journal-title":"Appl. Phys. Lett."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"5931","DOI":"10.1364\/OE.15.005931","article-title":"Variable-focus liquid lens","volume":"15","author":"Ren","year":"2007","journal-title":"Opt. Express"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2646","DOI":"10.1364\/OE.16.002646","article-title":"Tunable-focus liquid microlens array using dielectrophoretic effect","volume":"16","author":"Ren","year":"2008","journal-title":"Opt. Express"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"14954","DOI":"10.1364\/OE.16.014954","article-title":"Adaptive dielectric liquid lens","volume":"16","author":"Ren","year":"2008","journal-title":"Opt. Express"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1038\/nature05024","article-title":"Adaptive liquid microlenses activated by stimuli-responsive hydrogels","volume":"442","author":"Dong","year":"2006","journal-title":"Nature"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2370","DOI":"10.1364\/OE.11.002370","article-title":"Tunable liquid-filled microlens array integrated with microfluidic network","volume":"11","author":"Chronis","year":"2003","journal-title":"Opt. Express"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"9003","DOI":"10.1364\/OPEX.13.009003","article-title":"A set of two orthogonal adaptive cylindrical lenses in a monolith elastomer device","volume":"13","author":"Pang","year":"2005","journal-title":"Opt. Express"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1039\/b717037h","article-title":"Dynamically reconfigurable liquid-core liquid-cladding lens in a microfluidic channel","volume":"8","author":"Tang","year":"2008","journal-title":"Lab Chip"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4237","DOI":"10.1364\/OE.14.004237","article-title":"MEMS compatible micro-GRIN lenses for fiber to chip coupling of light","volume":"14","author":"Zickar","year":"2006","journal-title":"Opt. Express"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2387","DOI":"10.1039\/c005071g","article-title":"Tunable Two-Dimensional Liquid Gradient Refractive Index (L-GRIN) Lens for Variable Light Focusing","volume":"10","author":"Huang","year":"2010","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"10494","DOI":"10.1364\/OE.14.010494","article-title":"Mechanically tunable optofluidic distributed feedback dye laser","volume":"14","author":"Li","year":"2006","journal-title":"Opt. Express"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"12434","DOI":"10.1073\/pnas.0404423101","article-title":"Dynamic control of liquid-core\/liquid-cladding optical waveguides","volume":"101","author":"Wolfe","year":"2004","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1061\/(ASCE)1084-0699(1999)4:2(160)","article-title":"Approximate Convection-Diffusion Equations","volume":"4","author":"Perumal","year":"1999","journal-title":"J. Hydrol. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/j.snb.2004.11.014","article-title":"Hydrodynamic focusing in microchannels under consideration of diffusive dispersion: Theories and experiments","volume":"107","author":"Wu","year":"2005","journal-title":"Sens. Actuators B"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/BF00382036","article-title":"Flow of incompressible immiscible fluids between two plates","volume":"13","author":"Kapur","year":"1964","journal-title":"Appl. Sci. Res. A"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1038\/ncomms1662","article-title":"Optofluidic waveguide as a transformation optics device for lightwave bending and manipulation","volume":"3","author":"Yang","year":"2012","journal-title":"Nat. Commun."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1021\/je9501705","article-title":"Mutual diffusion coefficients of water + ethylene glycol and water + glycerol mixtures","volume":"41","author":"Ternstrom","year":"1996","journal-title":"Chem. Eng. Data"},{"key":"ref_25","unstructured":"Wang, M.H. (2009). Measurement of Binary Mutual Diffusion Coefficient of Several Aqueous Glycol Solutions. [Master\u2019s Thesis, Chung Yuan Christian University]. (In Chinese)."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/12\/1469\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:53:52Z","timestamp":1760216032000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/6\/12\/1469"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,10]]},"references-count":25,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["mi6121469"],"URL":"https:\/\/doi.org\/10.3390\/mi6121469","relation":{},"ISSN":["2072-666X"],"issn-type":[{"type":"electronic","value":"2072-666X"}],"subject":[],"published":{"date-parts":[[2015,12,10]]}}}