{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T14:43:27Z","timestamp":1778856207183,"version":"3.51.4"},"reference-count":24,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2016,3,10]],"date-time":"2016-03-10T00:00:00Z","timestamp":1457568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"The Major State Basic Research Development Program  of China (973 Program)","award":["no. 2012CB825804"],"award-info":[{"award-number":["no. 2012CB825804"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Microfluidic system is widely employed in the detection of environmental contaminants and biological specimens. One of the critical issues which limits the applications of microfluidic chips is the limit of detection of trace specimens. Liquid\u2013liquid extraction is of great importance in the preprocessing in microfluidic devices. In this paper, we developed a real-time fluorescence detection microfluidic chip combined with a microstructure-enhanced liquid\u2013liquid laminar extraction technique, which concentrated the trace compound and realized real-time monitoring. Auxiliary microstructures integrated in the microfluidic chip were applied to increase the extraction efficiency, which was proved by the FEM (finite element method) simulation as well. A common fluorescence probe, Rhodamine 6G (Rh6g), was used in the experiment to demonstrate the performance of the microfluidic system. It revealed that the liquid\u2013liquid laminar extraction combined with auxiliary microstructures of a cross shape was an effective method for enrichment. The efficiency of microstructure-enhanced liquid\u2013liquid extraction was increased by 350% compared to the traditional laminar flow extraction.<\/jats:p>","DOI":"10.3390\/mi7030046","type":"journal-article","created":{"date-parts":[[2016,3,10]],"date-time":"2016-03-10T10:53:48Z","timestamp":1457607228000},"page":"46","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Microstructure-Enhanced Liquid\u2013Liquid Extraction in a Real-Time Fluorescence Detection Microfluidic Chip"],"prefix":"10.3390","volume":"7","author":[{"given":"Penghui","family":"Xiong","sequence":"first","affiliation":[{"name":"Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3618-5954","authenticated-orcid":false,"given":"Xiangyu","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Xiong","sequence":"additional","affiliation":[{"name":"National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gang","family":"Liu","sequence":"additional","affiliation":[{"name":"National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yangchao","family":"Tian","sequence":"additional","affiliation":[{"name":"National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,3,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1038\/nature05062","article-title":"Control and detection of chemical reactions in microfluidic systems","volume":"442","author":"DeMello","year":"2006","journal-title":"Nature"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Xiao, J., Song, F.C., and Seo, S.W. (2013). A multilayered integrated sensor for three-dimensional, micro total analysis systems. J. Micromech. Microeng., 23.","DOI":"10.1088\/0960-1317\/23\/9\/095022"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1021\/ac3031543","article-title":"Micro total analysis systems: Fundamental advances and applications in the laboratory, clinic, and field","volume":"85","author":"Kovarik","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1021\/ac403688g","article-title":"Micro total analysis systems: Fundamental advances and biological applications","volume":"86","author":"Culbertson","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"5427","DOI":"10.1016\/S0040-4020(02)00513-6","article-title":"Solution phase synthesis of \u03b2-peptides using micro reactors","volume":"58","author":"Watts","year":"2002","journal-title":"Tetrahedron"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1126\/science.282.5388.484","article-title":"An integrated nanoliter DNA analysis device","volume":"282","author":"Burns","year":"1998","journal-title":"Science"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.1021\/ac0255330","article-title":"An integrated microfabricated cell sorter","volume":"74","author":"Fu","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.chroma.2005.04.013","article-title":"Complexities in tetracycline analysis-chemistry, matrix extraction, cleanup, and liquid chromatography","volume":"1075","author":"Anderson","year":"2005","journal-title":"J. Chromatogr. A"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1542","DOI":"10.1021\/ac0615246","article-title":"A reproducible surface-enhanced raman spectroscopy approach. Online SERS measurements in a segmented microfluidic system","volume":"79","author":"Strehle","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1815","DOI":"10.1002\/elps.200700554","article-title":"Recent advances in surface-enhanced raman scattering detection technology for microfluidic chips","volume":"29","author":"Chen","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.watres.2008.11.027","article-title":"Fluorescence as a potential monitoring tool for recycled water systems: A review","volume":"43","author":"Henderson","year":"2009","journal-title":"Water Res."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2342","DOI":"10.1016\/j.chroma.2009.11.088","article-title":"Evolution of dispersive liquid-liquid microextraction method","volume":"1217","author":"Rezaee","year":"2010","journal-title":"J. Chromatogr. A"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0924-4247(97)80219-1","article-title":"Diffusion-based extraction in a microfabricated device","volume":"58","author":"Brody","year":"1997","journal-title":"Sens. Actuators A Phys."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1115\/1.2768373","article-title":"Numerical characterization of diffusion-based extraction in cell-laden flow through a microfluidic channel","volume":"129","author":"Fleming","year":"2007","journal-title":"J. Biomech. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1007\/s11814-010-0533-8","article-title":"Microfluidic extraction using two phase laminar flow for chemical and biological applications","volume":"28","author":"Huh","year":"2011","journal-title":"Korean J. Chem. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lin, B. (2011). Microfluidics: Technologies and Applications, Springer.","DOI":"10.1007\/978-3-642-23050-9"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1039\/b600374e","article-title":"Initial study of two-phase laminar flow extraction chip for sample preparation for gas chromatography","volume":"6","author":"Xiao","year":"2006","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1039\/b411630p","article-title":"Intermittent partition walls promote solvent extraction of metal ions in a microfluidic device","volume":"129","author":"Maruyama","year":"2004","journal-title":"Analyst"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1039\/C5LC00045A","article-title":"Mixing with herringbone-inspired microstructures: Overcoming the diffusion limit in co-laminar microfluidic devices","volume":"15","author":"Marschewski","year":"2015","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"5123","DOI":"10.1016\/j.ces.2007.03.015","article-title":"Micro-channel reactor with guideline structure for organic\u2013aqueous binary system","volume":"62","author":"Tagawa","year":"2007","journal-title":"Chem. Eng. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/S0142-727X(02)00210-2","article-title":"Reynolds averaged simulation of unsteady separated flow","volume":"24","author":"Iaccarino","year":"2003","journal-title":"Int. J. Heat Fluid Flow"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Friend, J., and Yeo, L. (2010). Fabrication of microfluidic devices using polydimethylsiloxane. Biomicrofluidics, 4.","DOI":"10.1063\/1.3259624"},{"key":"ref_23","unstructured":"Zhou, Y. (2013). A Fluorescence Oil Detection Device, Louisiana State University."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1007\/s10404-013-1245-2","article-title":"Aqueous two-phase extraction for bovine serum albumin (BSA) with co-laminar flow in a simple coaxial capillary microfluidic device","volume":"16","author":"Huang","year":"2014","journal-title":"Microfluid. Nanofluid."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/3\/46\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:20:30Z","timestamp":1760210430000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/3\/46"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,10]]},"references-count":24,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2016,3]]}},"alternative-id":["mi7030046"],"URL":"https:\/\/doi.org\/10.3390\/mi7030046","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,3,10]]}}}