{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T18:54:19Z","timestamp":1773946459754,"version":"3.50.1"},"reference-count":82,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T00:00:00Z","timestamp":1460678400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Ontario Research Fund","award":["RE-WR-10"],"award-info":[{"award-number":["RE-WR-10"]}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["RGPIN\/262023-2013"],"award-info":[{"award-number":["RGPIN\/262023-2013"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Optofluidic devices combining micro-optical and microfluidic components bring a host of new advantages to conventional microfluidic devices. Aspects, such as optical beam shaping, can be integrated on-chip and provide high-sensitivity and built-in optical alignment. Optofluidic microflow cytometers have been demonstrated in applications, such as point-of-care diagnostics, cellular immunophenotyping, rare cell analysis, genomics and analytical chemistry. Flow control, light guiding and collecting, data collection and data analysis are the four main techniques attributed to the performance of the optofluidic microflow cytometer. Each of the four areas is discussed in detail to show the basic principles and recent developments. 3D microfabrication techniques are discussed in their use to make these novel microfluidic devices, and the integration of the whole system takes advantage of the miniaturization of each sub-system. The combination of these different techniques is a spur to the development of microflow cytometers, and results show the performance of many types of microflow cytometers developed recently.<\/jats:p>","DOI":"10.3390\/mi7040070","type":"journal-article","created":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T11:36:02Z","timestamp":1460720162000},"page":"70","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Optofluidic Device Based Microflow Cytometers for Particle\/Cell Detection: A Review"],"prefix":"10.3390","volume":"7","author":[{"given":"Yushan","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin","family":"Watts","sequence":"additional","affiliation":[{"name":"ArtIC Photonics, 260 Terence Matthews Cres, Ottawa, ON K2M 2C7, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianyi","family":"Guo","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiyi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Information and Communication Technologies, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changqing","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2786-9884","authenticated-orcid":false,"given":"Qiyin","family":"Fang","sequence":"additional","affiliation":[{"name":"Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L8, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,4,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1039\/C3LC51152A","article-title":"The intersection of flow cytometry with microfluidics and microfabrication","volume":"14","author":"Piyasena","year":"2014","journal-title":"Lab Chip"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1039\/C1LC20785G","article-title":"Simultaneous high speed optical and impedance analysis of single particles with a microfluidic cytometer","volume":"12","author":"Barat","year":"2012","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.tibtech.2014.04.010","article-title":"Commercialization of microfluidic devices","volume":"32","author":"Volpatti","year":"2014","journal-title":"Trends Biotechnol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1038\/nature05060","article-title":"Developing optofluidic technology through the fusion of microfluidics and optics","volume":"442","author":"Psaltis","year":"2006","journal-title":"Nature"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1856","DOI":"10.1039\/b816416a","article-title":"Optofluidics: Field or technique?","volume":"8","author":"Horowitz","year":"2008","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1039\/C3LC51211H","article-title":"Recent advancements in optofluidics-based single-cell analysis: Optical on-chip cellular manipulation, treatment, and property detection","volume":"14","author":"Huang","year":"2014","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1038\/171037b0","article-title":"A device for counting small particles suspended in a fluid through a tube","volume":"171","year":"1953","journal-title":"Nature"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1016\/j.snb.2012.02.077","article-title":"Hydrodynamic focusing for impedance-based detection of specifically bound microparticles and cells: Implications of fluid dynamics on tunable sensitivity","volume":"166\u2013167","author":"Justin","year":"2012","journal-title":"Sens. Actuators B Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2300","DOI":"10.1039\/c3lc41321g","article-title":"A microfluidic impedance flow cytometer for identification of differentiation state of stem cells","volume":"13","author":"Song","year":"2013","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.sna.2003.10.006","article-title":"3D microfabrication with inclined\/rotated UV lithography","volume":"111","author":"Han","year":"2004","journal-title":"Sens. Actuators A Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3263","DOI":"10.3390\/ijms12053263","article-title":"Microfluidic Mixing: A Review","volume":"12","author":"Lee","year":"2011","journal-title":"Int. J. Mol. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"R15","DOI":"10.1088\/0960-1317\/17\/5\/R01","article-title":"Lab-on-chip technologies: Making a microfluidic network and coupling it into a complete microsystem\u2013A review","volume":"17","author":"Abgrall","year":"2007","journal-title":"J. Micromech. Microeng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1038\/nature05058","article-title":"The origins and the future of microfluidics","volume":"442","author":"Whitesides","year":"2006","journal-title":"Nature"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s00216-009-2826-5","article-title":"Emerging optofluidic technologies for point-of-care genetic analysis systems: A review","volume":"395","author":"Brennan","year":"2009","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"81","DOI":"10.5966\/sctm.2013-0118","article-title":"Concise review: Microfluidic technology platforms: Poised to accelerate development and translation of stem cell-derived therapies","volume":"3","author":"Titmarsh","year":"2014","journal-title":"Stem Cells Transl. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4263","DOI":"10.1016\/j.bios.2011.03.042","article-title":"Microflow cytometer for optical analysis of phytoplankton","volume":"26","author":"Hashemi","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1177\/2211068212454853","article-title":"Microfluidic Systems for Diagnostic Applications: A Review","volume":"17","author":"Lei","year":"2012","journal-title":"J. Lab. Autom."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1039\/b717037h","article-title":"Dynamically reconfigurable liquid-core liquid-cladding lens in a microfluidic channel","volume":"8","author":"Tang","year":"2008","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Liang, L., Zuo, Y.F., Wu, W., Zhu, X.Q., and Yang, Y. (2016). Optofluidic restricted imaging, spectroscopy and counting of nanoparticles by evanescent wave using immiscible liquids. Lab Chip.","DOI":"10.1039\/C6LC00078A"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1002\/elps.201400211","article-title":"Counting of Escherichia coli by a microflow cytometer based on a photonic-microfluidic integrated device","volume":"36","author":"Guo","year":"2015","journal-title":"Electrophoresis"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"R73","DOI":"10.1088\/0967-3334\/26\/3\/R02","article-title":"Microfluidics for flow cytometric analysis of cells and particles","volume":"26","author":"Huh","year":"2005","journal-title":"Physiol. Meas"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"50","DOI":"10.3390\/mi5010050","article-title":"Dynamics of microvalve operations in integrated microfluidics","volume":"5","author":"Lau","year":"2014","journal-title":"Micromachines"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"442","DOI":"10.3390\/mi3020442","article-title":"Hydrodynamic flow confinement technology in microfluidic perfusion devices","volume":"3","author":"Ainla","year":"2012","journal-title":"Micromachines"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.snb.2010.09.055","article-title":"Highly efficient dual-channel cytometric-detection of micron-sized particles in microfluidic device","volume":"151","author":"Mu","year":"2011","journal-title":"Sens. Actuators B Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5334","DOI":"10.1021\/ac010504v","article-title":"Flow cytometry of Escherichia coli on microfluidic devices","volume":"73","author":"McClain","year":"2001","journal-title":"Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.snb.2003.10.010","article-title":"PDMS-based opto-fluidic micro flow cytometer with two-color, multi-angle fluorescence detection capability using PIN photodiodes","volume":"98","author":"Tung","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1874","DOI":"10.1002\/elps.200700630","article-title":"A high-discernment microflow cytometer with microweir structure","volume":"29","author":"Fu","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"4674","DOI":"10.3390\/s130404674","article-title":"Microflow cytometers with integrated hydrodynamic focusing","volume":"13","author":"Frankowski","year":"2013","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1002\/elsc.201400078","article-title":"Simultaneous optical and impedance analysis of single cells: A comparison of two microfluidic sensors with sheath flow focusing","volume":"15","author":"Frankowski","year":"2015","journal-title":"Eng. Life Sci."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1115\/1.1385514","article-title":"Hydrodynamic Focusing for a Micromachined Flow Cytometer","volume":"123","author":"Lee","year":"2001","journal-title":"J. Fluids Eng."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1364\/BOE.6.000054","article-title":"Micro flow cytometer with self-aligned 3D hydrodynamic focusing","volume":"6","author":"Testa","year":"2014","journal-title":"Biomed. Opt. Express"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1016\/j.mee.2009.01.017","article-title":"An efficient 3-dimensional hydrodynamic focusing microfluidic device by means of locally increased aspect ratio","volume":"86","author":"Kim","year":"2009","journal-title":"Microelectron. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1109\/JMEMS.2004.832196","article-title":"Three-dimensional hydrodynamic focusing in polydimethylsiloxane (PDMS) microchannels","volume":"13","author":"Sundararajan","year":"2004","journal-title":"J. Microelectromech. Syst."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.snb.2007.11.018","article-title":"Investigations of micrometer sample stream profiles in a three-dimensional hydrodynamic focusing device","volume":"132","author":"Hairer","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1039\/b822442k","article-title":"Multi-wavelength microflow cytometer using groove-generated sheath flow","volume":"9","author":"Golden","year":"2009","journal-title":"Lab Chip"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"5426","DOI":"10.1021\/ac9005827","article-title":"Multiplexed detection of bacteria and toxins using a microflow cytometer","volume":"81","author":"Kim","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.sna.2005.12.043","article-title":"Improved inclined multi-lithography using water as exposure medium and its 3D mixing microchannel application","volume":"128","author":"Sato","year":"2006","journal-title":"Sens. Actuators A Phys."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1039\/C3LC50810B","article-title":"Sub-micrometer-precision, three-dimensional (3D) hydrodynamic focusing via \u201cmicrofluidic drifting\u201d","volume":"14","author":"Nawaz","year":"2014","journal-title":"Lab Chip"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1039\/B716321E","article-title":"Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)","volume":"8","author":"Shi","year":"2007","journal-title":"Lab Chip"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1039\/c1lc20042a","article-title":"Three-dimensional continuous particle focusing in a microfluidic channel via standing surface acoustic waves (SSAW)","volume":"11","author":"Shi","year":"2011","journal-title":"Lab Chip"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1039\/C3LC51139A","article-title":"Standing surface acoustic wave (SSAW)-based microfluidic cytometer","volume":"14","author":"Chen","year":"2014","journal-title":"Lab Chip"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"3710","DOI":"10.1039\/C4LC00588K","article-title":"Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter","volume":"14","author":"Schmid","year":"2014","journal-title":"Lab Chip"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.3390\/mi6121463","article-title":"Three-dimensional electro-sonic flow focusing ionization microfluidic chip for mass spectrometry","volume":"6","author":"Yu","year":"2015","journal-title":"Micromachines"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2668","DOI":"10.1002\/elps.200900017","article-title":"Dielectrophoretic focusing of particles in a microchannel constriction using DC-biased AC flectric fields","volume":"30","author":"Zhu","year":"2009","journal-title":"Electrophoresis"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"261","DOI":"10.3795\/KSME-A.2009.33.3.261","article-title":"A three-dimensional particle focusing channel using the positive dielectrophoresis (pDEP) guided by a dielectric structure between two planar electrodes","volume":"33","author":"Chu","year":"2009","journal-title":"Trans. Korean Soc. Mech. Eng. A"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"62076","DOI":"10.1039\/C4RA13075H","article-title":"Real-time control of inertial focusing in microfluidics using dielectrophoresis (DEP)","volume":"4","author":"Zhang","year":"2014","journal-title":"RSC Adv."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.3390\/mi6111448","article-title":"Digital microfluidic system with vertical functionality","volume":"6","author":"Bender","year":"2015","journal-title":"Micromachines"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"045015","DOI":"10.1088\/0960-1317\/20\/4\/045015","article-title":"High-efficiency magnetic particle focusing using dielectrophoresis and magnetophoresis in a microfluidic device","volume":"20","author":"James","year":"2010","journal-title":"J. Micromech. Microeng."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"105018","DOI":"10.1088\/0960-1317\/22\/10\/105018","article-title":"Three-dimensional magnetic focusing of particles and cells in ferrofluid flow through a straight microchannel","volume":"22","author":"Zeng","year":"2012","journal-title":"J. Micromech. Microeng."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"15496","DOI":"10.3390\/s140815496","article-title":"Lab-on-chip cytometry based on magnetoresistive sensors for bacteria detection in milk","volume":"14","author":"Fernandes","year":"2014","journal-title":"Sensors"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1007\/s00216-007-1827-5","article-title":"The good, the bad, and the tiny: A review of microflow cytometry","volume":"391","author":"Ateya","year":"2008","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1109\/JMEMS.2004.838352","article-title":"Vertical focusing device utilizing dielectrophoretic force and its application on microflow cytometer","volume":"13","author":"Lin","year":"2004","journal-title":"J. Microelectromech. Syst."},{"key":"ref_53","first-page":"1","article-title":"A Review of Single-Mode Fiber Optofluidics","volume":"22","author":"Blue","year":"2015","journal-title":"IEEE J. Sel. Top. Quantum Electron"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"62","DOI":"10.3390\/mi3010062","article-title":"Fabrication and performance of a photonic-microfluidic integrated device","volume":"3","author":"Watts","year":"2012","journal-title":"Micromachines"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1002\/elps.201300195","article-title":"Scattering detection using a photonic-microfluidic integrated device with on-chip collection capabilities","volume":"35","author":"Watts","year":"2013","journal-title":"Electrophoresis"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1971","DOI":"10.3390\/mi6121468","article-title":"Fiber-based, injection-molded optofluidic systems: Improvements in assembly and applications","volume":"6","author":"Matteucci","year":"2015","journal-title":"Micromachines"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.optmat.2015.06.024","article-title":"Versatile liquid-core optofluidic waveguides fabricated in hydrophobic silica aerogels by femtosecond-laser ablation","volume":"47","author":"Yalizay","year":"2015","journal-title":"Opt. Mater."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1039\/C5LC01233C","article-title":"Reconfigurable liquid-core\/liquid-cladding optical waveguides with dielectrophoresis-driven virtual microchannels on an electromicrofluidic platform","volume":"6","author":"Fan","year":"2016","journal-title":"Lab Chip"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1366\/11-06389","article-title":"A solid-cladding\/liquid-core\/liquid-cladding sandwich optical waveguide for the study of dynamic extraction of dye by ionic liquid BmimPF 6","volume":"66","author":"Chen","year":"2012","journal-title":"Appl. Spectrosc."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"4398","DOI":"10.1039\/C5LC01066G","article-title":"Tunable self-imaging effect using hybrid optofluidic waveguides","volume":"15","author":"Shi","year":"2015","journal-title":"Lab Chip"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1039\/C4RA11027G","article-title":"Integrated real-time optofluidic SERS via a liquid-core\/liquid-cladding waveguide","volume":"5","author":"Choi","year":"2015","journal-title":"RSC Adv."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1580","DOI":"10.1039\/b805341c","article-title":"Fluorescent liquid-core\/air-cladding waveguides towards integrated optofluidic light sources","volume":"8","author":"Lim","year":"2008","journal-title":"Lab Chip"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"3182","DOI":"10.1039\/c1lc20435a","article-title":"A tunable 3D optofluidic waveguide dye laser via two centrifugal Dean flow streams","volume":"11","author":"Yang","year":"2011","journal-title":"Lab Chip"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1038\/ncomms1662","article-title":"Optofluidic waveguide as a transformation optics device for lightwave bending and manipulation","volume":"3","author":"Yang","year":"2012","journal-title":"Nat. Commun."},{"key":"ref_65","unstructured":"Watts, B.R. (2012). Development of a Microchip-Based Flow Cytometer with Integrated Optics\u2014Device Design, Fabrication, and Testing. [Ph.D Thesis, McMaster University]."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"27","DOI":"10.2478\/optof-2014-0002","article-title":"Soap films as 1D waveguides","volume":"1","author":"Emile","year":"2014","journal-title":"Optofluid. Microfluid Nanofluid."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1364\/BOE.1.000848","article-title":"Formation and characterization of an ideal excitation beam geometry in an optofluidic device","volume":"1","author":"Watts","year":"2010","journal-title":"Biomed. Opt. Express"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"3236","DOI":"10.1002\/elps.201200311","article-title":"A photonic-microfluidic integrated device for reliable fluorescence detection and counting","volume":"33","author":"Watts","year":"2012","journal-title":"Electrophoresis"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"2784","DOI":"10.1364\/BOE.3.002784","article-title":"Integration of optical components on-chip for scattering and fluorescence detection in an optofluidic device","volume":"3","author":"Watts","year":"2012","journal-title":"Biomed. Opt. Express"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1364\/BOE.4.001051","article-title":"A method for detecting forward scattering signals on-chip with a photonic-microfluidic integrated device","volume":"4","author":"Watts","year":"2013","journal-title":"Biomed. Opt. Express"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.1039\/c3lc41315b","article-title":"Microfluidic oxygen imaging using integrated optical sensor layers and a color camera","volume":"13","author":"Ungerbock","year":"2013","journal-title":"Lab Chip"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1039\/B516401J","article-title":"A microfluidic device for continuous, real time blood plasma separation","volume":"6","author":"Yang","year":"2006","journal-title":"Lab Chip"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"12511","DOI":"10.1039\/C4RA12676A","article-title":"A simple low-cost method to enhance luminescence and fluorescence signals in PDMS-based microfluidic devices","volume":"5","author":"Eyer","year":"2015","journal-title":"RSC Adv."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1039\/C1LC20672A","article-title":"Flexible planar microfluidic chip employing a light emitting diode and a PIN-photodiode for portable flow cytometers","volume":"12","author":"Kettlitz","year":"2012","journal-title":"Lab Chip"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s00216-014-8297-3","article-title":"An integrated microfluidic chip enabling control and spatially resolved monitoring of temperature in micro flow reactors","volume":"407","author":"Hoera","year":"2014","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1002\/cyto.a.22616","article-title":"Time-domain microfluidic fluorescence lifetime flow cytometry for high-throughput F\u00f6rster resonance energy transfer screening","volume":"87","author":"Nedbal","year":"2015","journal-title":"Cytom. A"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"17564","DOI":"10.1021\/ja2071779","article-title":"Three-dimensional paper microfluidic devices assembled using the principles of origami","volume":"133","author":"Liu","year":"2011","journal-title":"J. Am. Chem. Soc."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1021\/cr300337x","article-title":"Advances in microfluidic materials, functions, integration, and applications","volume":"113","author":"Nge","year":"2013","journal-title":"Chem. Rev."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1063\/1.3659016","article-title":"Sealing SU-8 microfluidic channels using PDMS","volume":"5","author":"Zhang","year":"2011","journal-title":"Biomicrofluidics"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.3390\/mi6121465","article-title":"A Simple and Reliable PDMS and SU-8 Irreversible Bonding Method and Its Application on a Microfluidic-MEA Device for Neuroscience Research","volume":"6","author":"Ren","year":"2015","journal-title":"Micromachines"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"1755","DOI":"10.3390\/mi6111454","article-title":"Using a microfluidic gradient generator to characterize BG-11 medium for the growth of cyanobacteria synechococcus elongatus PCC7942","volume":"6","author":"Yang","year":"2015","journal-title":"Micromachines"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1007\/s10404-008-0335-z","article-title":"Optical microflow cytometer for particle counting, sizing and fluorescence detection","volume":"6","author":"Chen","year":"2009","journal-title":"Microfluid. Nanofluid."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/4\/70\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:22:18Z","timestamp":1760210538000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/4\/70"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4,15]]},"references-count":82,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2016,4]]}},"alternative-id":["mi7040070"],"URL":"https:\/\/doi.org\/10.3390\/mi7040070","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4,15]]}}}