{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,5]],"date-time":"2026-07-05T01:19:24Z","timestamp":1783214364615,"version":"3.54.6"},"reference-count":56,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2016,5,4]],"date-time":"2016-05-04T00:00:00Z","timestamp":1462320000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>This paper presents a simple three-dimensional (3D) fabrication method based on soft lithography techniques and laminated object manufacturing. The method can create 3D structures that have undercuts with general machines for mass production and laboratory scale prototyping. The minimum layer thickness of the method is at least 4 \u00b5m and bonding strength between layers is over 330 kPa. The performance reaches conventional fabrication techniques used for two-dimensionally (2D)-designed microfluidic devices. We fabricated some 3D structures, i.e., fractal structures, spiral structures, and a channel-in-channel structure, in microfluidic channels and demonstrated 3D microfluidics. The fabrication method can be achieved with a simple black light for bio-molecule detection; thus, it is useful for not only lab-scale rapid prototyping, but also for commercial manufacturing.<\/jats:p>","DOI":"10.3390\/mi7050082","type":"journal-article","created":{"date-parts":[[2016,5,4]],"date-time":"2016-05-04T10:07:08Z","timestamp":1462356428000},"page":"82","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Three-Dimensional Fabrication for Microfluidics by Conventional Techniques and Equipment Used in Mass Production"],"prefix":"10.3390","volume":"7","author":[{"given":"Toyohiro","family":"Naito","sequence":"first","affiliation":[{"name":"Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noritada","family":"Kaji","sequence":"additional","affiliation":[{"name":"Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"},{"name":"ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Kubo","sequence":"additional","affiliation":[{"name":"Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinobu","family":"Baba","sequence":"additional","affiliation":[{"name":"Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"},{"name":"ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1088-0569","authenticated-orcid":false,"given":"Koji","family":"Otsuka","sequence":"additional","affiliation":[{"name":"Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,5,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3430","DOI":"10.1016\/S0006-3495(96)79538-3","article-title":"Biotechnology at low reynolds numbers","volume":"71","author":"Brody","year":"1996","journal-title":"Biophys. J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1126\/science.283.5400.346","article-title":"Microfluidic diffusion-based separation and detection","volume":"283","author":"Weigl","year":"1999","journal-title":"Science"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1021\/ar000062u","article-title":"Fabrication inside microchannels using fluid flow","volume":"33","author":"Kenis","year":"2000","journal-title":"Acc. Chem. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1126\/science.285.5424.83","article-title":"Microfabrication inside capillaries using multiphase laminar flow patterning","volume":"285","author":"Kenis","year":"1999","journal-title":"Science"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1039\/b305892a","article-title":"A novel in-plane passive microfluidic mixer with modified tesla structures","volume":"4","author":"Hong","year":"2004","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1126\/science.1094567","article-title":"Continuous particle separation through deterministic lateral displacement","volume":"304","author":"Huang","year":"2004","journal-title":"Science"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"14779","DOI":"10.1073\/pnas.0605967103","article-title":"Deterministic hydrodynamics: Taking blood apart","volume":"103","author":"Davis","year":"2006","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1448","DOI":"10.1039\/b805614e","article-title":"Crossing microfluidic streamlines to lyse, label and wash cells","volume":"8","author":"Morton","year":"2008","journal-title":"Lab Chip"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1039\/B809123D","article-title":"Size-selective separation of micro beads by utilizing secondary flow in a curved rectangular microchannel","volume":"9","author":"Yoon","year":"2009","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"094503","DOI":"10.1103\/PhysRevLett.102.094503","article-title":"Particle segregation and dynamics in confined flows","volume":"102","author":"Edd","year":"2009","journal-title":"Phys. Rev. Lett."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"7228","DOI":"10.1073\/pnas.0507976103","article-title":"Multivortex micromixing","volume":"103","author":"Sudarsan","year":"2006","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"18892","DOI":"10.1073\/pnas.0704958104","article-title":"Continuous inertial focusing, ordering, and separation of particles in microchannels","volume":"104","author":"Irimia","year":"2007","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1126\/science.1066238","article-title":"Chaotic mixer for microchannels","volume":"295","author":"Stroock","year":"2002","journal-title":"Science"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"015301","DOI":"10.1103\/PhysRevE.77.015301","article-title":"Bridging kinematics and concentration content in a chaotic micromixer","volume":"77","author":"Villermaux","year":"2008","journal-title":"Phys. Rev. E"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3356","DOI":"10.1039\/c1lc20342h","article-title":"Microfluidic baker\u2032s transformation device for three-dimensional rapid mixing","volume":"11","author":"Yasui","year":"2011","journal-title":"Lab Chip"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"57","DOI":"10.2116\/analsci.28.57","article-title":"Confocal microscopic evaluation of mixing performance or three-dimensional microfluidic mixer","volume":"28","author":"Yasui","year":"2012","journal-title":"Anal. Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6121","DOI":"10.1016\/j.biomaterials.2010.04.050","article-title":"A review on stereolithography and its applications in biomedical engineering","volume":"31","author":"Melchels","year":"2010","journal-title":"Biomaterials"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1039\/b103848f","article-title":"Static micromixers based on large-scale industrial mixer geometry","volume":"1","author":"Bertsch","year":"2001","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1109\/84.846699","article-title":"Passive mixing in a three-dimensional serpentine microchannel","volume":"9","author":"Liu","year":"2000","journal-title":"J. Microelectromech. Syst."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1039\/b923101c","article-title":"A simple method for fabricating multi-layer pdms structures for 3d microfluidic chips","volume":"10","author":"Zhang","year":"2010","journal-title":"Lab Chip"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1126\/science.288.5463.113","article-title":"Monolithic microfabricated valves and pumps by multilayer soft lithography","volume":"288","author":"Unger","year":"2000","journal-title":"Science"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1088\/0960-1317\/15\/5\/017","article-title":"A pneumatically controllable flexible and polymeric microfluidic valve fabricated via in situ development","volume":"15","author":"Baek","year":"2005","journal-title":"J. Micromech. Microeng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1038\/nphys1637","article-title":"Integrated elastomeric components for autonomous regulation of sequential and oscillatory flow switching in microfluidic devices","volume":"6","author":"Mosadegh","year":"2010","journal-title":"Nat. Phys."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3124","DOI":"10.1021\/ac4041857","article-title":"Cost-effective three-dimensional printing of visibly transparent microchips within minutes","volume":"86","author":"Shallan","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5437","DOI":"10.1021\/acs.analchem.5b00903","article-title":"3D-printed fluidic devices for nanoparticle preparation and flow-injection amperometry using integrated prussian blue nanoparticle-modified electrodes","volume":"87","author":"Bishop","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s10404-014-1542-4","article-title":"Direct, one-step molding of 3D-printed structures for convenient fabrication of truly 3d pdms microfluidic chips","volume":"19","author":"Chan","year":"2015","journal-title":"Microfluid. Nanofluid."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3124","DOI":"10.1002\/adma.201305506","article-title":"3D bioprinting of vascularized, heterogeneous cell-laden tissue constructs","volume":"26","author":"Kolesky","year":"2014","journal-title":"Adv. Mater"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1021\/acs.biomac.5b00188","article-title":"3D bioprinting human chondrocytes with nanocellulose-alginate bioink for cartilage tissue engineering applications","volume":"16","author":"Markstedt","year":"2015","journal-title":"Biomacromolecules"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3279","DOI":"10.1002\/adma.201500222","article-title":"Microfluidic printheads for multimaterial 3d printing of viscoelastic inks","volume":"27","author":"Hardin","year":"2015","journal-title":"Adv Mater"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1109\/JMEMS.2004.839334","article-title":"Stamp-and-stick room-temperature bonding technique for microdevices","volume":"14","author":"Satyanarayana","year":"2005","journal-title":"J. Microelectromech. Syst."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1039\/B712368J","article-title":"Microfluidic stickers","volume":"8","author":"Bartolo","year":"2008","journal-title":"Lab Chip"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1039\/b716594c","article-title":"Rapid prototyping of multilayer thiolene microfluidic chips by photopolymerization and transfer lamination","volume":"8","author":"Natali","year":"2008","journal-title":"Lab Chip"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1039\/c004436a","article-title":"Low-temperature, simple and fast integration technique of microfluidic chips by using a uv-curable adhesive","volume":"10","author":"Arayanarakool","year":"2010","journal-title":"Lab Chip"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"037002","DOI":"10.1088\/0960-1317\/23\/3\/037002","article-title":"Fabrication and bonding of thiol-ene-based microfluidic devices","volume":"23","author":"Sikanen","year":"2013","journal-title":"J. Micromech. Microeng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1039\/C2LC41030C","article-title":"Temperature-driven self-actuated microchamber sealing system for highly integrated microfluidic devices","volume":"13","author":"Naito","year":"2013","journal-title":"Lab Chip"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"3136","DOI":"10.1039\/c1lc20388f","article-title":"Beyond pdms: Off-stoichiometry thiol-ene (OSTE) based soft lithography for rapid prototyping of microfluidic devices","volume":"11","author":"Carlborg","year":"2011","journal-title":"Lab Chip"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1108\/RPJ-04-2013-0038","article-title":"Options for additive rapid prototyping methods (3D printing) in mems technology","volume":"20","author":"Lifton","year":"2014","journal-title":"Rapid Prototyp. J."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Farzadi, A., Solati-Hashjin, M., Asadi-Eydivand, M., and Abu Osman, N.A. (2014). Effect of layer thickness and printing orientation on mechanical properties and dimensional accuracy of 3D printed porous samples for bone tissue engineering. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0108252"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2721","DOI":"10.1152\/jn.00955.2014","article-title":"Incorporating 3d-printing technology in the design of head-caps and electrode drives for recording neurons in multiple brain regions","volume":"113","author":"Headley","year":"2015","journal-title":"J. Neurophysiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"9875","DOI":"10.1038\/srep09875","article-title":"Development of a 3D printer using scanning projection stereolithography","volume":"5","author":"Lee","year":"2015","journal-title":"Sci. Rep."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1108\/RPJ-09-2013-0093","article-title":"Evaluation of dimensional accuracy and material properties of the makerbot 3d desktop printer","volume":"21","author":"Melenka","year":"2015","journal-title":"Rapid Prototyp. J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1109\/JMEMS.2005.844746","article-title":"Studies on surface wettability of poly(dimethyl) siloxane (pdms) and glass under oxygen-plasma treatment and correlation with bond strength","volume":"14","author":"Bhattacharya","year":"2005","journal-title":"J. Microelectromech. Syst."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1088\/0964-1726\/15\/1\/018","article-title":"Microfluidic channel fabrication by pdms-interface bonding","volume":"15","author":"Chow","year":"2006","journal-title":"Smart Mater. Struct."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"067001","DOI":"10.1088\/0960-1317\/18\/6\/067001","article-title":"Determining the optimal PDMS-PDMS bonding technique for microfluidic devices","volume":"18","author":"Eddings","year":"2008","journal-title":"J. Micromech. Microeng."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1039\/b818389a","article-title":"Rapid prototyping of microfluidic systems using a pdms\/polymer tape composite","volume":"9","author":"Kim","year":"2009","journal-title":"Lab Chip"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.chaos.2014.11.004","article-title":"A fractal approach to the dark silicon problem: A comparison of 3D computer architectures\u2014Standard slices versus fractal menger sponge geometry","volume":"70","author":"Herrmann","year":"2015","journal-title":"Chaos Solitons Fractals"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1736","DOI":"10.1039\/C4LC01392A","article-title":"Monolithic multilayer microfluidics via sacrificial molding of 3D-printed isomalt","volume":"15","author":"Gelber","year":"2015","journal-title":"Lab Chip"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Parekh, D.P., Ladd, C., Panich, L., Moussa, K., and Dickey, M.D. (2016). 3D printing of liquid metals as fugitive inks for fabrication of 3D microfluidic channels. Lab Chip.","DOI":"10.1039\/C6LC00198J"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"2336","DOI":"10.1088\/0960-1317\/16\/11\/013","article-title":"A monolithically three-dimensional flow-focusing device for formation of single\/double emulsions in closed\/open microfluidic systems","volume":"16","author":"Huang","year":"2006","journal-title":"J. Micromech. Microeng."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1039\/C3LC51072G","article-title":"Interdroplet bilayer arrays in millifluidic droplet traps from 3D-printed moulds","volume":"14","author":"King","year":"2014","journal-title":"Lab Chip"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s40684-015-0027-6","article-title":"Geometry modulation of microlens array using spin coating and evaporation processes of photoresist mixture","volume":"2","author":"Kim","year":"2015","journal-title":"Int. J. Precis. Eng. Manuf. Green Technol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"159ra147","DOI":"10.1126\/scitranslmed.3004249","article-title":"A human disease model of drug toxicity\u2013induced pulmonary edema in a lung-on-a-chip microdevice","volume":"4","author":"Huh","year":"2012","journal-title":"Sci. Transl. Med."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"2165","DOI":"10.1039\/c2lc40074j","article-title":"Human gut-on-a-chip inhabited by microbial flora that experiences intestinal peristalsis-like motions and flow","volume":"12","author":"Kim","year":"2012","journal-title":"Lab Chip"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1038\/nmeth.2938","article-title":"Bone marrow-on-a-chip replicates hematopoietic niche physiology in vitro","volume":"11","author":"Torisawa","year":"2014","journal-title":"Nat. Methods"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1039\/C4LC01252F","article-title":"A lung-on-a-chip array with an integrated bio-inspired respiration mechanism","volume":"15","author":"Stucki","year":"2015","journal-title":"Lab Chip"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"3663","DOI":"10.1039\/c3lc50274k","article-title":"Size based sorting and patterning of microbeads by evaporation driven flow in a 3D micro-traps array","volume":"13","author":"Wong","year":"2013","journal-title":"Lab Chip"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/5\/82\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:23:15Z","timestamp":1760210595000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/5\/82"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,4]]},"references-count":56,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2016,5]]}},"alternative-id":["mi7050082"],"URL":"https:\/\/doi.org\/10.3390\/mi7050082","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,4]]}}}