{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T15:52:39Z","timestamp":1773330759045,"version":"3.50.1"},"reference-count":29,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2016,8,8]],"date-time":"2016-08-08T00:00:00Z","timestamp":1470614400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Seventh Framework Programme","award":["248763"],"award-info":[{"award-number":["248763"]}]},{"DOI":"10.13039\/501100003132","name":"Agentschap voor Innovatie door Wetenschap en Technologie","doi-asserted-by":"publisher","award":["111212"],"award-info":[{"award-number":["111212"]}],"id":[{"id":"10.13039\/501100003132","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000781","name":"European Research Council","doi-asserted-by":"publisher","award":["340931"],"award-info":[{"award-number":["340931"]}],"id":[{"id":"10.13039\/501100000781","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS) pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD). A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS) and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode) and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12    \u03bc   V\/V\/mmHg) and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg\/day drift after 50 h). During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.<\/jats:p>","DOI":"10.3390\/mi7080135","type":"journal-article","created":{"date-parts":[[2016,8,8]],"date-time":"2016-08-08T10:14:38Z","timestamp":1470651278000},"page":"135","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device"],"prefix":"10.3390","volume":"7","author":[{"given":"Luigi","family":"Brancato","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Heverlee, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Grim","family":"Keulemans","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Heverlee, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Verbelen","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Sciences, Experimental Cardiac Surgery, KU Leuven, Herestraat 49, 3000 Leuven, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bart","family":"Meyns","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Sciences, Experimental Cardiac Surgery, KU Leuven, Herestraat 49, 3000 Leuven, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Puers","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Heverlee, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,8,8]]},"reference":[{"key":"ref_1","unstructured":"World Health Organization Fact sheet 310\u2014The top 10 causes of death. Available online: http:\/\/www.who.int\/mediacenter\/factsheets\/fs310\/en\/."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.healun.2015.10.003","article-title":"Seventh INTERMACS annual report: 15,000 patients and counting","volume":"34","author":"Kirklin","year":"2015","journal-title":"J. Heart Lung Transpl."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1109\/TBCAS.2014.2346015","article-title":"An innovative adaptive control strategy for sensorized left ventricular assist devices","volume":"8","author":"Verbeni","year":"2014","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Cysyk, J., Jhun, C.S., Newswanger, R., Weiss, W., and Rosenberg, G. (September, January 30). Rotary blood pump control using integrated inlet pressure sensor. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.","DOI":"10.1109\/IEMBS.2011.6090121"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/34\/1\/R1","article-title":"Developments in control systems for rotary left ventricular assist devices for heart failure patients: A review","volume":"34","author":"AlOmari","year":"2012","journal-title":"Physiol. Meas."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s10544-007-9146-3","article-title":"Long term, implantable blood pressure monitoring systems","volume":"10","author":"Potkay","year":"2008","journal-title":"Biomed. Microdevices"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1177\/1538574410375128","article-title":"A Novel Treatment Approach to a Type II Endoleak at Endograft Implantation Using Components of an Endosensor Monitoring Device","volume":"44","author":"Louwers","year":"2010","journal-title":"Vasc. Endovasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"20620","DOI":"10.3390\/s141120620","article-title":"Chronically implanted pressure sensors: Challenges and state of the field","volume":"14","author":"Yu","year":"2014","journal-title":"Sensors"},{"key":"ref_9","unstructured":"St. Jude Medical CardioMEMS HF System, Pulmonary Artery (PA) Pressure Monitoring. Available online: https:\/\/www.sjm.com\/en\/sjm\/cardiomems?alert=DeepLinkSoftAlertclset=af584191-45c9-4201-8740-5409f4cf8bdd%3ab20716c1-c2a6-4e4c-844b-d0dd6899eb3a."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0140-6736(15)00723-0","article-title":"Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: Complete follow-up results from the CHAMPION randomised trial","volume":"387","author":"Abraham","year":"2015","journal-title":"Lancet"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1109\/JSEN.2009.2030982","article-title":"Wireless batteryless implantable blood pressure monitoring microsystem for small laboratory animals","volume":"10","author":"Cong","year":"2010","journal-title":"Sensors"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1023\/A:1012452613720","article-title":"An implantable microsystem for tonometric blood pressure measurement","volume":"3","author":"Ziaie","year":"2001","journal-title":"Biomed. Microdevices"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1046\/j.1525-1594.2001.025005376.x","article-title":"A Blood Pressure Sensor for Long-Term Implantation","volume":"25","author":"Bullister","year":"2001","journal-title":"Artif. Organs"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/MAT.0b013e3181d2a56e","article-title":"Development of an inlet pressure sensor for control in a left ventricular assist device","volume":"56","author":"Fritz","year":"2010","journal-title":"ASAIO J."},{"key":"ref_15","unstructured":"Saito, I., Chinzei, T., Isoyama, T., Miura, H., Kouno, A., Ono, T., Nakagawa, H., Yamaguchi-Sekine, S., Shi, W., and Inoue, Y. (2008). 7th Asian-Pacific Conference on Medical and Biological Engineering (APCMBE), Springer."},{"key":"ref_16","unstructured":"Wei, S., Saito, I., Chinzei, T., Isoyama, T., Miura, H., Kouno, A., Ono, T., Nakagawa, H., Yamaguchi, S., and Inoue, Y. (2008). 7th Asian-Pacific Conference on Medical and Biological Engineering (APCMBE), Springer."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3376","DOI":"10.1039\/b703416b","article-title":"Current strategies towards hemocompatible coatings","volume":"17","author":"Werner","year":"2007","journal-title":"J. Mater. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3405","DOI":"10.1039\/b801491d","article-title":"Advances in polymers for anti-biofouling surfaces","volume":"18","author":"Krishnan","year":"2008","journal-title":"J. Mater. Chem."},{"key":"ref_19","unstructured":"Specialty Coating Systems SCS Parylene Properties. Available online: http:\/\/scscoatings.com\/corporate\/technical-library\/."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1002\/jbm.10076","article-title":"Hemocompatibility of materials used in microelectromechanical systems: Platelet adhesion and morphology in vitro","volume":"60","author":"Weisenberg","year":"2002","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1046\/j.1525-1594.2002.07126.x","article-title":"Physiologic control algorithms for rotary blood pumps using pressure sensor input","volume":"26","author":"Bullister","year":"2002","journal-title":"Artif. Organs"},{"key":"ref_22","unstructured":"Teng, M.F., Hariz, A.J., and Hsu, H.Y. (2006). Smart Materials, Nano-and Micro-Smart Systems, International Society for Optics and Photonics."},{"key":"ref_23","unstructured":"Tomita, M., Takayama, N., Wada, H., Hirafune, S., Okude, S., and Suemasu, T. Digital Output Ultra-Small Atmospheric Pressure Sensor. Available online: http:\/\/www.fujikura.co.jp\/eng\/rd\/gihou\/backnumber\/pages\/icsFiles\/afieldfile\/2014\/07\/04\/43e03.pdf."},{"key":"ref_24","unstructured":"TDK Electronics T5403: Digital Barometric Pressure Sensor. Available online: http:\/\/en.tdk.eu\/blob\/531174\/download\/4\/t5403-applicationnote.pdf."},{"key":"ref_25","unstructured":"STMicroelectronics LPS22HB: MEMS Nano Pressure Sensor. Available online: http:\/\/www.st.com\/content\/ccc\/resource\/technical\/document\/datasheet\/bf\/c1\/4f\/23\/61\/17\/44\/8a\/DM00140895.pdf\/files\/DM00140895.pdf\/jcr:content\/translations\/en.DM00140895.pdf."},{"key":"ref_26","unstructured":"Lipps, N., and Velderrain, M. (2011). Moisture Permeability of Silicone Systems: Case Study #2, NuSil Technology LLC."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1053\/j.semtcvs.2008.08.001","article-title":"Current Axial-Flow Devices -The HeartMate II and Jarvik 2000 Left Ventricular Assist Devices","volume":"20","author":"John","year":"2008","journal-title":"Semin. Thorac. Cardiovasc. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/00002480-200107000-00020","article-title":"HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor","volume":"47","author":"Bourque","year":"2001","journal-title":"ASAIO J."},{"key":"ref_29","first-page":"12","article-title":"HeartWare Miniature Axial-Flow Ventricular Assist Device","volume":"36","author":"Slaughter","year":"2009","journal-title":"TEX Heart Inst. J."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/8\/135\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:28:00Z","timestamp":1760210880000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/8\/135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,8]]},"references-count":29,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,8]]}},"alternative-id":["mi7080135"],"URL":"https:\/\/doi.org\/10.3390\/mi7080135","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,8]]}}}