{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T14:33:11Z","timestamp":1785162791951,"version":"3.55.0"},"reference-count":34,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000930","name":"NSF","doi-asserted-by":"publisher","award":["CBET-0853873"],"award-info":[{"award-number":["CBET-0853873"]}],"id":[{"id":"10.13039\/501100000930","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"NSFC","doi-asserted-by":"publisher","award":["51575003"],"award-info":[{"award-number":["51575003"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Electrokinetic manipulation refers to the control of particle and cell motions using an electric field. It is an efficient technique for microfluidic applications with the ease of operation and integration. It, however, suffers from an intrinsic drawback of low throughput due to the linear dependence of the typically very low fluid permittivity. We demonstrate in this work a significantly enhanced throughput for electrokinetic manipulation of particles and cells by the use of multiple parallel microchannels in a two-layer stacked microfluidic device. The fabrication of this device is simple without the need of a precise alignment of the two layers. The number of layers and the number of microchannels in each layer can thus be further increased for a potentially high throughput electrokinetic particle and cell manipulations.<\/jats:p>","DOI":"10.3390\/mi7090156","type":"journal-article","created":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T10:04:28Z","timestamp":1472724268000},"page":"156","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Enhanced Throughput for Electrokinetic Manipulation of Particles and Cells in a Stacked Microfluidic Device"],"prefix":"10.3390","volume":"7","author":[{"given":"Lin","family":"Zhu","sequence":"first","affiliation":[{"name":"School of Engineering, Anhui Agricultural University, Hefei 230036, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3650-1790","authenticated-orcid":false,"given":"Saurin","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Johnson","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshay","family":"Kale","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yash","family":"Raval","sequence":"additional","affiliation":[{"name":"Department of Biological Sciences, Clemson University, Clemson, SC 29634-0314, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1835-9639","authenticated-orcid":false,"given":"Tzuen-Rong","family":"Tzeng","sequence":"additional","affiliation":[{"name":"Department of Biological Sciences, Clemson University, Clemson, SC 29634-0314, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0158-4186","authenticated-orcid":false,"given":"Xiangchun","family":"Xuan","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,9,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3931","DOI":"10.1002\/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO;2-M","article-title":"Recent developments in electrokinetically driven analysis on microfabricated devices","volume":"21","author":"Bruin","year":"2000","journal-title":"Electrophoresis"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1109\/TMECH.2004.828659","article-title":"Electrokinetics in micro devices for biotechnology applications","volume":"9","author":"Wong","year":"2004","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_3","unstructured":"Chang, H.C., and Yeo, L.Y. (2010). Electrokinetically Driven Microfluidics and Nanofluidics, Cambridge University Press."},{"key":"ref_4","unstructured":"Li, D. (2004). Electrokinetics in Microfluidics, Elsevier Academic Press."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Masliyah, J.H., and Bhattacharjee, S. (2006). Electrokinetic and Colloid Transport Phenomena, Wiley-Interscience.","DOI":"10.1002\/0471799742"},{"key":"ref_6","unstructured":"Hunter, R.J. (1981). Zeta Potential in Colloid Science, Academic Press."},{"key":"ref_7","unstructured":"Lyklemma, J. (1991). Fundamentals of Interface and Colloid Science, Academic Press."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1063\/1.1387591","article-title":"Flexible methods for microfluidics","volume":"54","author":"Whitesides","year":"2001","journal-title":"Phys. Today"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s10404-009-0408-7","article-title":"Electrokinetic motion of particles and cells in microchannels","volume":"6","author":"Kang","year":"2009","journal-title":"Microfluid. Nanofluid."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Qian, S., and Ai, Y. (2012). Electrokinetic Particle Transport in Micro-\/Nanofluidics: Direct Numerical Simulation Analysis, CRC Press.","DOI":"10.1201\/b12128"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Probstein, R.F. (1994). Physicochemical Hydrodynamics, John Willey and Sons. [2nd ed.].","DOI":"10.1002\/0471725137"},{"key":"ref_12","unstructured":"Kirby, B.J. (2010). Micro and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices, Cambridge University Press."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1002\/elps.200700302","article-title":"Joule heating in electrokinetic flow","volume":"29","author":"Xuan","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1002\/elps.200700601","article-title":"Effect of Joule heating on electrokinetic transport","volume":"29","author":"Cetin","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1196\/annals.1363.007","article-title":"Cell injury by electric forces","volume":"1066","author":"Lee","year":"2005","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1146\/annurev.bioeng.8.061505.095739","article-title":"Electrical forces for microscale cell manipulation","volume":"8","author":"Voldman","year":"2006","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"033104","DOI":"10.1063\/1.4953183","article-title":"Refinement of current monitoring methodology for electroosmotic flow assessment under low ionic strength conditions","volume":"10","year":"2016","journal-title":"Biomicrofluidics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1039\/b816986a","article-title":"Micromagnetic\u2013microfluidic blood cleansing device","volume":"9","author":"Yung","year":"2009","journal-title":"Lab Chip"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1039\/C0LC00148A","article-title":"Hydrophoretic high-throughput selection of platelets in physiologicalshear-stress range","volume":"11","author":"Choi","year":"2011","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"022206","DOI":"10.1063\/1.3576780","article-title":"High-throughput size-based rare cell enrichment using microscale vortices","volume":"5","author":"Hur","year":"2011","journal-title":"Biomicrofluidics"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.bios.2012.07.021","article-title":"Microfluidic flow fractionation device for label-free isolation of circulating tumor cells (CTCs) from breast cancer patients","volume":"40","author":"Hyun","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1007\/s10404-012-1069-5","article-title":"Enhanced-throughput production of polymersomes using a parallelized capillary microfluidic device","volume":"14","author":"Kim","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"33149","DOI":"10.1039\/C4RA06513A","article-title":"High throughput extraction of plasma using a secondary flow-aided inertial microfluidic device","volume":"4","author":"Zhang","year":"2014","journal-title":"RSC Adv."},{"key":"ref_24","unstructured":"Yu, Z.T.F., Guan, H., Cheung, M.K., McHugh, W.M., Cornell, T.T., Shanley, T.P., Kurabayashi, K., and Fu, J. (2015). Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA. Sci. Rep., 11339."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"034102","DOI":"10.1063\/1.4732800","article-title":"Microfluidic separation of live and dead yeast cells using reservoir-based dielectrophoresis (rDEP)","volume":"6","author":"Patel","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1002\/elps.201200467","article-title":"Reservoir-based dielectrophoresis (rDEP) for microfluidic particle separation by charge","volume":"34","author":"Patel","year":"2013","journal-title":"Electrophoresis"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1002\/elps.201100484","article-title":"Electrokinetic particle entry into microchannels","volume":"33","author":"Zhu","year":"2012","journal-title":"Electrophoresis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.jcis.2004.11.003","article-title":"The electrokinetic properties of latex particles: Comparison of electrophoresis and dielectrophoresis","volume":"285","author":"Ermolina","year":"2005","journal-title":"J. Colloid Interface Sci."},{"key":"ref_29","unstructured":"Morgan, H., and Green, N.G. (2002). AC Electrokinetics: Colloids and Nanoparticles, Research Studies Press."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2526","DOI":"10.1021\/ac991165x","article-title":"Conditions for similitude between the fluid velocity and electric field in electroosmotic flow","volume":"72","author":"Cummings","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2668","DOI":"10.1002\/elps.200900017","article-title":"Dielectrophoretic focusing of particles in a microchannel constriction using DC-biased AC electric fields","volume":"30","author":"Zhu","year":"2009","journal-title":"Electrophoresis"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1002\/elps.200500558","article-title":"Continuous separation of microparticles by size with DC-dielectrophoresis","volume":"27","author":"Kang","year":"2006","journal-title":"Electrophoresis"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1007\/s10404-011-0839-9","article-title":"Continuous flow separation of particles and cells in a serpentine microchannel via curvature-induced dielectrophoresis","volume":"11","author":"Zhu","year":"2011","journal-title":"Microfluid. Nanofluid."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"044109","DOI":"10.1063\/1.3267098","article-title":"Electrokinetic focusing and filtration of cells in a serpentine microchannel","volume":"3","author":"Church","year":"2009","journal-title":"Biomicrofluidics"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/9\/156\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:29:49Z","timestamp":1760210989000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/7\/9\/156"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,1]]},"references-count":34,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2016,9]]}},"alternative-id":["mi7090156"],"URL":"https:\/\/doi.org\/10.3390\/mi7090156","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9,1]]}}}