{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:51:03Z","timestamp":1760241063109,"version":"build-2065373602"},"publisher-location":"Basel Switzerland","reference-count":29,"publisher":"MDPI","license":[{"start":{"date-parts":[[2019,11,21]],"date-time":"2019-11-21T00:00:00Z","timestamp":1574294400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"MINISTERIO DE ECONOMIA Y COMPETITIVIDAD","award":["IPT-2012-1126-300000"],"award-info":[{"award-number":["IPT-2012-1126-300000"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.3390\/proceedings2019031067","type":"proceedings-article","created":{"date-parts":[[2019,11,22]],"date-time":"2019-11-22T02:49:27Z","timestamp":1574390967000},"page":"67","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A Quality and Ergonomic Heart Monitoring Device with User-Friendly App for Telemedicine"],"prefix":"10.3390","author":[{"given":"Andres L.","family":"Bleda","sequence":"first","affiliation":[{"name":"CETEM\u2014Technological Centre of Furniture and Wood of the Region de Murcia, 30510 Yecla, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafael","family":"Maestre","sequence":"additional","affiliation":[{"name":"CETEM\u2014Technological Centre of Furniture and Wood of the Region de Murcia, 30510 Yecla, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Corral","sequence":"additional","affiliation":[{"name":"RGB Medical Devices, 28037 Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ricardo","family":"Ruiz","sequence":"additional","affiliation":[{"name":"RGB Medical Devices, 28037 Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,11,21]]},"reference":[{"key":"ref_1","unstructured":"WHO (2002). Active Ageing: A Policy Framework, WHO."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s12652-009-0003-5","article-title":"Towards evolutionary ambient assisted living systems","volume":"1","author":"Muldoon","year":"2010","journal-title":"J. Ambient Intell. Humaniz. Comput."},{"key":"ref_3","unstructured":"World Health Organization (2018, December 18). Available online: http:\/\/www.who.int\/cardiovascular_diseases\/en\/."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"102ra95","DOI":"10.1126\/scitranslmed.3002557","article-title":"Computationally generated cardiac biomarkers for risk stratification after acute coronary syndrome","volume":"3","author":"Syed","year":"2011","journal-title":"Sci. Transl. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1109\/TBME.2006.872823","article-title":"ECG measurement on a chair without conductive contact","volume":"53","author":"Lim","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Adib, F., Mao, H., Kabelac, Z., Katabi, D., and Miller, R.C. (2015, January 18\u201323). Smart homes that monitor breathing and heart rate. Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems, Seoul, Korea.","DOI":"10.1145\/2702123.2702200"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1161\/01.CIR.0000154900.76284.F6","article-title":"Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research","volume":"111","author":"Pickering","year":"2005","journal-title":"Circulation"},{"key":"ref_8","unstructured":"(2018, December 17). Omron Healthcare. Available online: https:\/\/omronhealthcare.com\/blood-pressure\/."},{"key":"ref_9","unstructured":"(2018, December 17). ViveHealth Blood Pressure Monitor. Available online: https:\/\/www.vivehealth.com\/products\/blood-pressure-monitor-cuff."},{"key":"ref_10","unstructured":"(2018, December 17). QardioArm Blood Pressure Monitor. Available online: https:\/\/www.getqardio.com\/es\/qardioarm-blood-pressure-monitor-iphone-android\/."},{"key":"ref_11","unstructured":"(2018, December 17). QardioArm Mobile Application. Available online: https:\/\/www.getqardio.com\/es\/qardioapp\/."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.emc.2005.08.013","article-title":"ECG techniques and technologies","volume":"24","author":"Garvey","year":"2006","journal-title":"Emerg. Med. Clin."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Ye, C., Coimbra, M.T., and Kumar, B.V. (2010, January 27\u201329). Investigation of human identification using two-lead electrocardiogram (ECG) signals. Proceedings of the 2010 Fourth IEEE International Conference on Biometrics: Theory Applications and Systems (BTAS), Washington, DC, USA.","DOI":"10.1109\/BTAS.2010.5634478"},{"key":"ref_14","unstructured":"(2018, December 17). AliveCor ECG Measurement Device. Available online: https:\/\/www.alivecor.com\/."},{"key":"ref_15","unstructured":"(2018, December 17). CheckMe Lite Vital Signs Monitor. Available online: https:\/\/www.viatomtech.com\/checkme-lite."},{"key":"ref_16","unstructured":"(2018, December 17). SnapECG Handheld ECG Recorder. Available online: http:\/\/www.mhealth365.com\/en\/product-4.html."},{"key":"ref_17","unstructured":"(2018, December 17). QardioCore ECG Monitor. Available online: https:\/\/store-eu.getqardio.com\/products\/qardiocore."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"20170821","DOI":"10.1098\/rsif.2017.0821","article-title":"Computational techniques for ECG analysis and interpretation in light of their contribution to medical advances","volume":"15","author":"Lyon","year":"2018","journal-title":"J. R. Soc. Interface"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"e12390","DOI":"10.1111\/anec.12390","article-title":"Analysis of ECG measures of cardiac repolarization in relation to arrhythmic events in an implantable cardioverter defibrillator population","volume":"22","author":"Shi","year":"2017","journal-title":"Ann. Noninvasive Electrocardiol."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Pinto, J.R., Cardoso, J.S., Louren\u00e7o, A., and Carreiras, C. (2017). Towards a continuous biometric system based on ECG signals acquired on the steering wheel. Sensors, 17.","DOI":"10.3390\/s17102228"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1038\/s41598-017-00540-x","article-title":"Efficient ECG Compression and QRS Detection for E-Health Applications","volume":"7","author":"Elgendi","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_22","first-page":"43","article-title":"Wireless ECG Circuit on Flexible Material: A Preliminary Study","volume":"10","author":"Sahar","year":"2018","journal-title":"J. Telecommun. Electr. Comput. Eng. (JTEC)"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"16451","DOI":"10.3390\/s131216451","article-title":"Mobile cloud-computing-based healthcare service by noncontact ECG monitoring","volume":"13","author":"Fong","year":"2013","journal-title":"Sensors"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"040005","DOI":"10.1063\/1.5023975","article-title":"Design of portable electrocardiogram device using DSO138","volume":"1933","author":"Abuzairi","year":"2018","journal-title":"AIP Conf.Proc."},{"key":"ref_25","unstructured":"(2018, December 17). Qoolife Webpage. Available online: https:\/\/qoolife.com\/?locale=en."},{"key":"ref_26","unstructured":"(2018, December 17). Biopac System. Available online: https:\/\/www.biopac.com\/."},{"key":"ref_27","unstructured":"Kwon, S., Lee, J., Chung, G.S., and Park, K.S. (September, January 30). Validation of heart rate extraction through an iPhone accelerometer. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"11465","DOI":"10.3390\/s150511465","article-title":"A wearable context-aware ECG monitoring system integrated with built-in kinematic sensors of the smartphone","volume":"15","author":"Miao","year":"2015","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Kranjec, J., Begu\u0161, S., Ger\u0161ak, G., \u0160inkovec, M., Drnov\u0161ek, J., and Hudoklin, D. (2017). Design and Clinical Evaluation of a Non-Contact Heart Rate Variability Measuring Device. Sensors, 17.","DOI":"10.3390\/s17112637"}],"event":{"name":"The International Conference on Ubiquitous Computing and Ambient \u202aIntelligence","acronym":"UCAmI 2019"},"container-title":["13th International Conference on Ubiquitous Computing and Ambient \u202aIntelligence UCAmI 2019\u202c"],"original-title":[],"link":[{"URL":"https:\/\/www.mdpi.com\/2504-3900\/31\/1\/67\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:36:13Z","timestamp":1760189773000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2504-3900\/31\/1\/67"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,21]]},"references-count":29,"alternative-id":["proceedings2019031067"],"URL":"https:\/\/doi.org\/10.3390\/proceedings2019031067","relation":{},"subject":[],"published":{"date-parts":[[2019,11,21]]}}}