{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:05:09Z","timestamp":1760144709620,"version":"build-2065373602"},"reference-count":31,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T00:00:00Z","timestamp":1715904000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics"],"abstract":"<jats:p>Augmentative exoskeletons (AEs) are wearable orthotic devices that, when coupled with a healthy individual, can significantly enhance endurance, speed, and strength. Exoskeletons are function-specific and individual-specific, with a multitude of possible configurations and joint mechanisms. This complexity presents a challenging scenario to quantitatively determine the optimal choice of the kinematic configuration of the exoskeleton for the intended activity. A comprehensive simulation-based framework for obtaining an optimal configuration of a passive augmentative exoskeleton for backpack load carriage during walking is the theme of this research paper. A musculoskeletal-based simulation approach on 16 possible kinematic configurations with different Degrees of Freedom (DoF) at the exoskeleton structure\u2019s hip, knee, and ankle joints was performed, and a configuration with three DoF at the hip, one DoF at the knee, three DoF at the ankle was quantitatively chosen. The Root Mean Square of Deviations (RMSD) and Maximum Deviations (MaxDev) between the kinematically coupled human\u2013exoskeleton system were used as criteria along with the Cumulative Weight Score (CWS). The chosen configuration from the simulation was designed, realised, and experimentally validated. The error of the joint angles between the simulation and experiments with the chosen configuration was less than 3\u00b0 at the hip and ankle joints and less than 6\u00b0 at the knee joints.<\/jats:p>","DOI":"10.3390\/robotics13050079","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T06:53:49Z","timestamp":1715928829000},"page":"79","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Simulation-Based Framework to Determine the Kinematic Compatibility of an Augmentative Exoskeleton during Walking"],"prefix":"10.3390","volume":"13","author":[{"given":"S.","family":"Nagarajan","sequence":"first","affiliation":[{"name":"Defence Bioengineering and Electromedical Laboratory (DEBEL), DRDO, MoD, Bengaluru 560093, Karnataka, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Mohanavelu","sequence":"additional","affiliation":[{"name":"Defence Bioengineering and Electromedical Laboratory (DEBEL), DRDO, MoD, Bengaluru 560093, Karnataka, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3456-1220","authenticated-orcid":false,"given":"S.","family":"Sujatha","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600036, Tamil Nadu, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,5,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"102044","DOI":"10.1088\/1742-6596\/1507\/10\/102044","article-title":"A preliminary study of the military applications and future of individual exoskeletons","volume":"1507","author":"Zhou","year":"2020","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/s10033-019-0389-8","article-title":"A Review on Lower Limb Rehabilitation Exoskeleton Robots","volume":"32","author":"Shi","year":"2019","journal-title":"Chin. J. Mech. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Golabchi, A., Chao, A., and Tavakoli, M. (2022). A Systematic Review of Industrial Exoskeletons for Injury Prevention: Efficacy Evaluation Metrics, Target Tasks, and Supported Body Postures. Sensors, 22.","DOI":"10.3390\/s22072714"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1242\/jeb.00279","article-title":"Insights into the evolution of human bipedalism from experimental studies of humans and other primates","volume":"206","author":"Schmitt","year":"2003","journal-title":"J. Exp. Biol."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Gull, M.A., Bai, S., and Bak, T. (2020). A Review on Design of Upper Limb Exoskeletons. Robotics, 9.","DOI":"10.3390\/robotics9010016"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Torricelli, D., Del Ama, A.J., Gonzalez, J., Moreno, J., Gil, A., and Pons, J.L. (2015, January 1\u20133). Benchmarking lower limb wearable robots: Emerging approaches and technologies. Proceedings of the 8th ACM International Conference on PErvasive Technologies Related to Assistive Environments, Cofru, Greece.","DOI":"10.1145\/2769493.2769589"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"535","DOI":"10.3109\/17483107.2015.1080766","article-title":"Exoskeletons\u2019 design and usefulness evidence according to a systematic review of lower limb exoskeletons used for functional mobility by people with spinal cord injury","volume":"11","author":"Lajeunesse","year":"2015","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"138042","DOI":"10.1109\/ACCESS.2021.3115956","article-title":"Recent Development of Unpowered Exoskeletons for Lower Extremity: A Survey","volume":"9","author":"Zhang","year":"2021","journal-title":"IEEE Access"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1155\/2014\/585837","article-title":"Design considerations of a lower limb exoskeleton system to assist walking and load-carrying of infantry soldiers","volume":"11","author":"Yu","year":"2014","journal-title":"Appl. Bion. Biomech."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1109\/TRO.2008.915453","article-title":"Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art","volume":"24","author":"Dollar","year":"2008","journal-title":"IEEE Trans. Robot."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1109\/TNSRE.2016.2521160","article-title":"State of the Art and Future Directions for Lower Limb Robotic Exoskeletons","volume":"25","author":"Young","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Mallat, R., Khalil, M., Venture, G., Bonnet, V., and Mohammed, S. (2019, January 17\u201319). Human-exoskeleton joint misalignment: A systematic review. Proceedings of the 2019 Fifth International Conference on Advances in Biomedical Engineering (ICABME), Tripoli, Lebanon.","DOI":"10.1109\/ICABME47164.2019.8940321"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3389\/fnbot.2018.00018","article-title":"A Subject-Specific Kinematic Model to Predict Human Motion in Exoskeleton-Assisted Gait","volume":"12","author":"Torricelli","year":"2018","journal-title":"Front. Neurorobot."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Cenciarini, M., and Dollar, A.M. (July, January 29). Biomechanical considerations in the design of lower limb exoskeletons. Proceedings of the 2011 IEEE International Conference on Rehabilitation Robotics, Zurich, Switzerland.","DOI":"10.1109\/ICORR.2011.5975366"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/1743-0003-6-21","article-title":"Exoskeletons and orthoses: Classification, design challenges and future directions","volume":"6","author":"Herr","year":"2009","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s12984-017-0247-9","article-title":"Physical interface dynamics alter how robotic exosuits augment human movement: Implications for optimizing wearable assistive devices","volume":"14","author":"Yandell","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"050802","DOI":"10.1115\/1.4042523","article-title":"Misalignment Compensation for Full Human-Exoskeleton Kinematic Compatibility: State of the Art and Evaluation","volume":"70","author":"Junius","year":"2018","journal-title":"Appl. Mech. Rev."},{"key":"ref_18","first-page":"5751391","article-title":"A Review on Compliant Joint Mechanisms for Lower Limb Exoskeletons","volume":"2016","year":"2016","journal-title":"J. Robot."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1109\/TRO.2009.2019147","article-title":"Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations","volume":"25","author":"Stienen","year":"2009","journal-title":"IEEE Trans. Robot."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1109\/TRO.2012.2226381","article-title":"Self-Alignment Mechanisms for Assistive Wearable Robots: A Kinetostatic Compatibility Method","volume":"29","author":"Cempini","year":"2012","journal-title":"IEEE Trans. Robot."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1109\/TRO.2011.2178151","article-title":"Connecting a Human Limb to an Exoskeleton","volume":"28","author":"Jarrasse","year":"2011","journal-title":"IEEE Trans. Robot."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Bartenbach, V., Wyss, D., Seuret, D., and Riener, R. (2015, January 11\u201314). A lower limb exoskeleton research platform to investigate human-robot interaction. Proceedings of the 2015 IEEE International Conference on Rehabilitation Robotics (ICORR), Singapore.","DOI":"10.1109\/ICORR.2015.7281266"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1109\/TRO.2015.2450414","article-title":"Knee Joint Misalignment in Exoskeletons for the Lower Extremities: Effects on User\u2019s Gait","volume":"31","author":"Zanotto","year":"2015","journal-title":"IEEE Trans. Robot."},{"key":"ref_24","first-page":"1","article-title":"Xsens MVN: Consistent Tracking of Human Motion Using Inertial Sensing","volume":"1","author":"Schepers","year":"2018","journal-title":"Xsens. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.medengphy.2018.12.021","article-title":"Musculoskeletal model-based inverse dynamic analysis under ambulatory conditions using inertial motion capture","volume":"65","author":"Karatsidis","year":"2019","journal-title":"Med. Eng. Phys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1016\/j.jbiomech.2014.12.034","article-title":"TLEM 2.0\u2014A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity","volume":"48","author":"Carbone","year":"2015","journal-title":"J. Biomech."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1016\/j.simpat.2006.09.001","article-title":"Analysis of musculoskeletal systems in the AnyBody Modeling System","volume":"14","author":"Damsgaard","year":"2006","journal-title":"Simul. Model. Pract. Theory"},{"key":"ref_28","first-page":"1","article-title":"Xsens MVN: Full 6DOF human motion tracking using miniature inertial sensors","volume":"1","author":"Roetenberg","year":"2009","journal-title":"Xsens Motion Technol. BV Tech. Rep."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.apergo.2018.09.013","article-title":"Lower extremity kinematics of cross-slope roof walking","volume":"75","author":"Breloff","year":"2018","journal-title":"Appl. Ergon."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.gaitpost.2014.03.004","article-title":"Footwear traction and three-dimensional kinematics of level, downhill, uphill and cross-slope walking","volume":"40","author":"Wannop","year":"2014","journal-title":"Gait Posture"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/s12984-022-00990-z","article-title":"Assessing effects of exoskeleton misalignment on knee joint load during swing using an instrumented leg simulator","volume":"19","author":"Schaake","year":"2022","journal-title":"J. Neuroeng. Rehabil."}],"container-title":["Robotics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2218-6581\/13\/5\/79\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:43:58Z","timestamp":1760107438000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2218-6581\/13\/5\/79"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,17]]},"references-count":31,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,5]]}},"alternative-id":["robotics13050079"],"URL":"https:\/\/doi.org\/10.3390\/robotics13050079","relation":{},"ISSN":["2218-6581"],"issn-type":[{"type":"electronic","value":"2218-6581"}],"subject":[],"published":{"date-parts":[[2024,5,17]]}}}