{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T04:01:45Z","timestamp":1793332905426,"version":"4.5.0"},"reference-count":127,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:00:00Z","timestamp":1734480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"MUR","award":["H53D23000610006"],"award-info":[{"award-number":["H53D23000610006"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics"],"abstract":"<jats:p>In the last decades, there has been an increasing number of human patients who suffer from upper-limb disorders limiting their motor abilities. One of the possible solutions that gained extensive research interest is the development of robot-aided rehabilitation training setups, including either end-effector or exoskeleton robots, which showed various advantages compared to traditional manual rehabilitation therapy. One of the main challenges of these systems is to control the robot\u2019s motion to track a desirable rehabilitation training trajectory while being affected by either voluntary or involuntary human forces depending on the patient\u2019s recovery state. Several previous studies have been targeting exoskeleton robotic systems focusing on their structure, clinical features, and control methods, with limited review on end-effector-based robotic rehabilitation systems. In this regard, an overview of the most common end-effector robotic devices used for upper-limb rehabilitation is provided in this paper, describing their mechanical structure, features, clinical application, commercialization, advantages, and shortcomings. Additionally, a comprehensive review on possible control methods applied to end-effector rehabilitation exploitation is presented. These control methods are categorized as conventional, robust, intelligent, and most importantly, adaptive controllers implemented to serve for diverse rehabilitation control modes, addressing their development, implementation, findings, and possible drawbacks.<\/jats:p>","DOI":"10.3390\/robotics13120181","type":"journal-article","created":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T11:17:22Z","timestamp":1734520642000},"page":"181","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["A Comprehensive Review of Control Challenges and Methods in End-Effector Upper-Limb Rehabilitation Robots"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1854-1951","authenticated-orcid":false,"given":"Dalia M.","family":"Mahfouz","sequence":"first","affiliation":[{"name":"Mechatronics Department, Faculty of Engineering and Materials Science, German University in Cairo (GUC), Cairo 11835, Egypt"},{"name":"Multi-Robot Systems (MRS) Research Group, Cairo 11835, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3604-3534","authenticated-orcid":false,"given":"Omar M.","family":"Shehata","sequence":"additional","affiliation":[{"name":"Mechatronics Department, Faculty of Engineering and Materials Science, German University in Cairo (GUC), Cairo 11835, Egypt"},{"name":"Multi-Robot Systems (MRS) Research Group, Cairo 11835, Egypt"},{"name":"Mechatronics Department, Faculty of Engineering, Ain Shams University (ASU), Cairo 11517, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elsayed I.","family":"Morgan","sequence":"additional","affiliation":[{"name":"Mechatronics Department, Faculty of Engineering and Materials Science, German University in Cairo (GUC), Cairo 11835, Egypt"},{"name":"Multi-Robot Systems (MRS) Research Group, Cairo 11835, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9750-8289","authenticated-orcid":false,"given":"Filippo","family":"Arrichiello","sequence":"additional","affiliation":[{"name":"Electrical and Information Engineering Department, University of Cassino and Southern Lazio (UNICAS), 03043 Cassino, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,18]]},"reference":[{"key":"ref_1","unstructured":"World Health Organization (2022). Global Oral Health Status Report: Towards Universal Health Coverage for Oral Health by 2030, World Health Organization."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1136\/annrheumdis-2019-215142","article-title":"The world-wide burden of musculoskeletal diseases: A systematic analysis of the World Health Organization Burden of Diseases Database","volume":"78","author":"Sebbag","year":"2019","journal-title":"Ann. Rheum. Dis."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Belluzzi, E., Pozzuoli, A., and Ruggieri, P. (2023). Musculoskeletal Diseases: From Molecular Basis to Therapy. Biomedicines, 12.","DOI":"10.3390\/biomedicines12010032"},{"key":"ref_4","unstructured":"World Health Organization (2006). Neurological Disorders: Public Health Challenges, World Health Organization."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1177\/17474930211065917","article-title":"World Stroke Organization (WSO): Global stroke fact sheet 2022","volume":"17","author":"Feigin","year":"2022","journal-title":"Int. J. Stroke"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"155","DOI":"10.23736\/S1973-9087.17.04746-3","article-title":"The World Health Organization \u201crehabilitation 2030: A call for action\u201d","volume":"53","author":"Gimigliano","year":"2017","journal-title":"Eur. J. Phys. Rehabil. Med."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Zhang, L., Guo, S., and Sun, Q. (2020). An assist-as-needed controller for passive, assistant, active, and resistive robot-aided rehabilitation training of the upper extremity. Appl. Sci., 11.","DOI":"10.3390\/app11010340"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.medengphy.2016.04.004","article-title":"Bilateral robots for upper-limb stroke rehabilitation: State of the art and future prospects","volume":"38","author":"Sheng","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"S174","DOI":"10.1016\/j.pmrj.2018.06.005","article-title":"Exoskeleton and end-effector robots for upper and lower limbs rehabilitation: Narrative review","volume":"10","author":"Molteni","year":"2018","journal-title":"PM&R"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Iandolo, R., Marini, F., Semprini, M., Laffranchi, M., Mugnosso, M., Cherif, A., De Michieli, L., Chiappalone, M., and Zenzeri, J. (2019). Perspectives and challenges in robotic neurorehabilitation. Appl. Sci., 9.","DOI":"10.3390\/app9153183"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"106117","DOI":"10.1109\/ACCESS.2022.3210514","article-title":"Wearable robotics for impaired upper-limb assistance and rehabilitation: State of the art and future perspectives","volume":"10","author":"Proietti","year":"2022","journal-title":"IEEE Access"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s42454-023-00048-y","article-title":"A comparative study of end-effector and exoskeleton type rehabilitation robots in human upper extremity rehabilitation","volume":"5","author":"Bhujel","year":"2023","journal-title":"Hum.-Intell. Syst. Integr."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Qassim, H.M., and Wan Hasan, W. (2020). A review on upper limb rehabilitation robots. Appl. Sci., 10.","DOI":"10.3390\/app10196976"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1109\/TCDS.2021.3098350","article-title":"Machine learning in robot assisted upper limb rehabilitation: A focused review","volume":"15","author":"Ai","year":"2021","journal-title":"IEEE Trans. Cogn. Dev. Syst."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1743-0003-1-5","article-title":"Rehabilitation robotics: Pilot trial of a spatial extension for MIT-Manus","volume":"1","author":"Krebs","year":"2004","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1310\/RYT5-62N4-CTVX-8JTE","article-title":"Advances in the understanding and treatment of stroke impairment using robotic devices","volume":"12","author":"Hidler","year":"2005","journal-title":"Top. Stroke Rehabil."},{"key":"ref_17","unstructured":"Nef, T., and Riener, R. (July, January 28). ARMin-design of a novel arm rehabilitation robot. Proceedings of the 9th International Conference on Rehabilitation Robotics, ICORR 2005, Chicago, IL, USA."},{"key":"ref_18","unstructured":"Lum, P.S., Burgar, C.G., Van der Loos, M., Shor, P.C., Majmundar, M., and Yap, R. (July, January 28). The MIME robotic system for upper-limb neuro-rehabilitation: Results from a clinical trial in subacute stroke. Proceedings of the 9th International Conference on Rehabilitation Robotics, ICORR 2005, Chicago, IL, USA."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1016\/S0003-9993(02)04954-7","article-title":"Robot-assisted arm trainer for the passive and active practice of bilateral forearm and wrist movements in hemiparetic subjects","volume":"84","author":"Hesse","year":"2003","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_20","unstructured":"Loureiro, R., Amirabdollahian, F., and Harwin, W. (2004). 22 A Gentle\/S Approach to Robot Assisted Neuro-Rehabilitation. Advances in Rehabilitation Robotics: Human-Friendly Technologies on Movement Assistance and Restoration for People with Disabilities, Springer."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Stefano, M., Patrizia, P., Mario, A., Ferlini, G., Rizzello, R., and Rosati, G. (2014). Robotic upper limb rehabilitation after acute stroke by NeReBot: Evaluation of treatment costs. BioMed Res. Int., 2014.","DOI":"10.1155\/2014\/265634"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ellis, M.D., Sukal, T., DeMott, T., and Dewald, J.P. (2007, January 12\u201315). ACT 3D exercise targets gravity-induced discoordination and improves reaching work area in individuals with stroke. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics, Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428529"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Stienen, A.H., McPherson, J.G., Schouten, A.C., and Dewald, J.P. (July, January 29). The ACT-4D: A novel rehabilitation robot for the quantification of upper limb motor impairments following brain injury. Proceedings of the 2011 IEEE International Conference on Rehabilitation Robotics, Zurich, Switzerland.","DOI":"10.1109\/ICORR.2011.5975460"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1080\/17483107.2018.1425747","article-title":"Robot-assisted upper extremity rehabilitation for cervical spinal cord injuries: A systematic scoping review","volume":"13","author":"Singh","year":"2018","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Balasubramanian, S., Wei, R., Perez, M., Shepard, B., Koeneman, E., Koeneman, J., and He, J. (2008, January 25\u201327). RUPERT: An exoskeleton robot for assisting rehabilitation of arm functions. Proceedings of the 2008 Virtual Rehabilitation, Vancouver, BC, Canada.","DOI":"10.1109\/ICVR.2008.4625154"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Fitle, K.D., Pehlivan, A.U., and O\u2019malley, M.K. (2015, January 26\u201330). A robotic exoskeleton for rehabilitation and assessment of the upper limb following incomplete spinal cord injury. Proceedings of the 2015 IEEE International Conference on Robotics and Automation (ICRA), Seattle, WA, USA.","DOI":"10.1109\/ICRA.2015.7139888"},{"key":"ref_27","first-page":"100279","article-title":"Myoelectric arm orthosis assists functional activities: A 3-month home use outcome report","volume":"5","author":"Chang","year":"2023","journal-title":"Arch. Rehabil. Res. Clin. Transl."},{"key":"ref_28","unstructured":"Garcia, D.A., Arredondo, R., Morris, M., and Tosunoglu, S. (August, January 30). A review of rehabilitation strategies for stroke recovery. Proceedings of the ASME Early Career Technical Conference, Atlanta, GA, USA."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1109\/TMECH.2007.901934","article-title":"Upper-limb powered exoskeleton design","volume":"12","author":"Perry","year":"2007","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., and Riener, R. (2007, January 12\u201315). ARMin-Exoskeleton for arm therapy in stroke patients. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics, Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428408"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Nef, T., Guidali, M., Klamroth-Marganska, V., and Riener, R. (2009). ARMin-exoskeleton robot for stroke rehabilitation. Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Munich, Germany, 7\u201312 September 2009: Vol. 25\/9 Neuroengineering, Neural Systems, Rehabilitation and Prosthetics, Springer.","DOI":"10.1007\/978-3-642-03889-1_35"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Gopura, R.A.R.C., Kiguchi, K., and Li, Y. (2009, January 11\u201315). SUEFUL-7: A 7DOF upper-limb exoskeleton robot with muscle-model-oriented EMG-based control. Proceedings of the 2009 IEEE\/RSJ International Conference on Intelligent Robots and Systems, St. Louis, MO, USA.","DOI":"10.1109\/IROS.2009.5353935"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1080\/11762320902920575","article-title":"Isotropy of an upper limb exoskeleton and the kinematics and dynamics of the human arm","volume":"6","author":"Perry","year":"2009","journal-title":"Appl. Bionics Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/PHM.0000000000000852","article-title":"Efficacy of Armeo\u00ae robotic therapy versus conventional therapy on upper limb function in children with hemiplegic cerebral palsy","volume":"97","year":"2018","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Hyakutake, K., Morishita, T., Saita, K., Fukuda, H., Shiota, E., Higaki, Y., Inoue, T., and Uehara, Y. (2019). Effects of Home-Based Robotic Therapy Involving the Single-Joint Hybrid Assistive Limb Robotic Suit in the Chronic Phase of Stroke: A Pilot Study. BioMed Res. Int., 2019.","DOI":"10.1155\/2019\/5462694"},{"key":"ref_36","first-page":"972069","article-title":"A systematic review of bilateral upper limb training devices for poststroke rehabilitation","volume":"2012","author":"Peper","year":"2012","journal-title":"Stroke Res. Treat."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1109\/RBME.2016.2552201","article-title":"Upper-limb robotic exoskeletons for neurorehabilitation: A review on control strategies","volume":"9","author":"Proietti","year":"2016","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Krebs, H.I., Edwards, D.J., and Volpe, B.T. (2022). Forging mens et manus: The mit experience in upper extremity robotic therapy. Neurorehabilitation Technology, Springer.","DOI":"10.1007\/978-3-031-08995-4_26"},{"key":"ref_39","first-page":"653","article-title":"Understanding and treating arm movement impairment after chronic brain injury: Progress with the ARM guide","volume":"37","author":"Reinkensmeyer","year":"2000","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Sadeghnejad, S., Abadi, V.S.E., and Jafari, B. (2023). Rehabilitation robotics: History, applications, and recent advances. Medical and Healthcare Robotics, Academic Press.","DOI":"10.1016\/B978-0-443-18460-4.00008-1"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1109\/TNSRE.2007.908560","article-title":"Design, implementation and clinical tests of a wire-based robot for neurorehabilitation","volume":"15","author":"Rosati","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_42","unstructured":"Rosati, G., Gallina, P., Masiero, S., and Rossi, A. (July, January 28). Design of a new 5 dof wire-based robot for rehabilitation. Proceedings of the 9th International Conference on Rehabilitation RoboticsICORR 2005, Chicago, IL, USA."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1109\/TNSRE.2004.827225","article-title":"Evidence for improved muscle activation patterns after retraining of reaching movements with the MIME robotic system in subjects with post-stroke hemiparesis","volume":"12","author":"Lum","year":"2004","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1682\/JRRD.2010.04.0062","article-title":"Robot-assisted upper-limb therapy in acute rehabilitation setting following stroke: Department of Veterans Affairs multisite clinical trial","volume":"48","author":"Burgar","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Hsieh, Y.W., Liing, R.J., Lin, K.C., Wu, C.Y., Liou, T.H., Lin, J.C., and Hung, J.W. (2016). Sequencing bilateral robot-assisted arm therapy and constraint-induced therapy improves reach to press and trunk kinematics in patients with stroke. J. Neuroeng. Rehabil.","DOI":"10.1186\/s12984-016-0138-5"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/1743-0003-10-35","article-title":"Unilateral versus bilateral robot-assisted rehabilitation on arm-trunk control and functions post stroke: A randomized controlled trial","volume":"10","author":"Wu","year":"2013","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1743-0003-4-4","article-title":"Multivariate analysis of the Fugl-Meyer outcome measures assessing the effectiveness of GENTLE\/S robot-mediated stroke therapy","volume":"4","author":"Amirabdollahian","year":"2007","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1108\/01439910310506783","article-title":"HapticMaster\u2013a generic force controlled robot for human interaction","volume":"30","author":"Lammertse","year":"2003","journal-title":"Ind. Robot. Int. J."},{"key":"ref_49","unstructured":"Van der Linde, R.Q., Lammertse, P., Frederiksen, E., and Ruiter, B. (2002). The HapticMaster, a new high-performance haptic interface. Proc. Eurohaptics, Edinburgh University."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/1743-0003-11-45","article-title":"Effects of task-oriented robot training on arm function, activity, and quality of life in chronic stroke patients: A randomized controlled trial","volume":"11","author":"Timmermans","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"580","DOI":"10.2340\/16501977-0087","article-title":"Robot-mediated upper limb physiotherapy for patients with spastic hemiparesis: A preliminary study","volume":"39","author":"Fazekas","year":"2007","journal-title":"J. Rehabil. Med."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Bratanov, D., and Vitliemov, P. (2020, January 28\u201329). The experience behind the reharob project\u2013a new robotic system for simultaneous rehabilitation of upper and lower human limbs. Proceedings of the 2020 International Conference on Assistive and Rehabilitation Technologies (iCareTech), Gaza, Palestine.","DOI":"10.1109\/iCareTech49914.2020.00010"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Ellis, M.D., and Dewald, J.P. (2009). Application of the ACT 3D Robot in the Evaluation of Functional Reaching Performance and the Administration of Experimental Interventions. Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Munich, Germany, 7\u201312 September 2009: Vol. 25\/9 Neuroengineering, Neural Systems, Rehabilitation and Prosthetics, Springer.","DOI":"10.1007\/978-3-642-03889-1_100"},{"key":"ref_54","first-page":"132","article-title":"Effectiveness of robotic therapy in the proximal and distal rehabilitation of the upper limb in patients after stroke using the Amadeo\u00ae and Armeo\u00ae devices: A systematic review of randomized clinical trials (Efectividad de la terapia rob\u00f3tica en la rehabilitaci\u00f3n proximal y distal del miembro superior en personas tras un ictus con los dispositivos Amadeo\u00ae y Armeo\u00ae: Una revisi\u00f3n sistem\u00e1tica de ensayos cl\u00ednicos aleatorizados)","volume":"43","year":"2022","journal-title":"Stud. Psychol."},{"key":"ref_55","unstructured":"Helbok, R., Schoenherr, G., Spiegel, M., Sojer, M., and Brenneis, C. (2010). Robot-Assisted Hand Training (Amadeo) Compared with Conventional Physiotherapy Techniques in Chronic Ischemic Stroke Patients: A Pilot Study, DGNR."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Serrano-L\u00f3pez Terradas, P.A., Criado Ferrer, T., Jakob, I., and Calvo-Arenillas, J.I. (2022). Quo Vadis, Amadeo Hand Robot? A Randomized Study with a Hand Recovery Predictive Model in Subacute Stroke. Int. J. Environ. Res. Public Health, 20.","DOI":"10.3390\/ijerph20010690"},{"key":"ref_57","unstructured":"L\u00f3pez-Terradas, P.A.S., Rosendo, D.M., and Lago, M.R. (2013). Hand Functional Recovery in Sub-acute Brain Injury Stage Patients using AMADEO\u00ae Robotic-assisted Therapy-A Pilot Clinical Study with Apraxic and Neglect Patients. Special Session on Virtual and Augmented Reality Systems for Upper Limbs Rehabilitation, Scitepress."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1109\/TNSRE.2012.2195679","article-title":"Taking a lesson from patients\u2019 recovery strategies to optimize training during robot-aided rehabilitation","volume":"20","author":"Colombo","year":"2012","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/1743-0003-7-13","article-title":"Self-adaptive robot training of stroke survivors for continuous tracking movements","volume":"7","author":"Vergaro","year":"2010","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3233\/THC-2006-14301","article-title":"Braccio di Ferro: A new haptic workstation for neuromotor rehabilitation","volume":"14","author":"Casadio","year":"2006","journal-title":"Technol. Health Care"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Elangovan, N., Yeh, I.L., Holst-Wolf, J., and Konczak, J. (2019, January 24\u201328). A robot-assisted sensorimotor training program can improve proprioception and motor function in stroke survivors. Proceedings of the 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR), Toronto, ON, Canada.","DOI":"10.1109\/ICORR.2019.8779409"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1186\/s12984-021-00925-0","article-title":"Efficacy of wrist robot-aided orthopedic rehabilitation: A randomized controlled trial","volume":"18","author":"Albanese","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_63","unstructured":"Konczak, J. (2024, November 24). WristBot: A Robotic System for the Diagnosis and Physical Rehabilitation of Sensory and Motor Dysfunction of the Wrist and Hand. Available online: https:\/\/news.cehd.umn.edu\/konczak-receives-grant-to-advance-robotic-rehabilitation-technology\/."},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Passon, A., Schauer, T., and Seel, T. (2020). Inertial-robotic motion tracking in end-effector-based rehabilitation robots. Front. Robot. AI, 7.","DOI":"10.3389\/frobt.2020.554639"},{"key":"ref_65","unstructured":"MOTIONrehab (2024, November 27). Robot-Assisted Arm Rehabilitation with DIEGO. Available online: https:\/\/www.motionrehab.co.uk\/intensive-neurological-rehabilitation-centre\/diego\/."},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Saracino, L., Avizzano, C.A., Ruffaldi, E., Cappiello, G., Curto, Z., and Scoglio, A. (2016, January 24\u201327). MOTORE++ a portable haptic device for domestic rehabilitation. Proceedings of the IECON 2016-42nd Annual Conference of the IEEE Industrial Electronics Society, Florence, Italy.","DOI":"10.1109\/IECON.2016.7793115"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"O\u2019Flaherty, D., and Ali, K. (2024). Recommendations for upper limb motor recovery: An overview of the UK and European rehabilitation after stroke guidelines (2023). Healthcare, 12.","DOI":"10.3390\/healthcare12141433"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1080\/09593985.2018.1480679","article-title":"Variations in physiotherapy practice in neurological rehabilitation trajectories\u2013an explorative interview and observational study","volume":"36","author":"Irgens","year":"2020","journal-title":"Physiother. Theory Pract."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Harmelink, K., Dandis, R., der Van der Wees Pj, P., Zeegers, A., der Sanden, M.N.V., and Staal, J. (2021). Recovery trajectories over six weeks in patients selected for a high-intensity physiotherapy program after Total knee Arthroplasty: A latent class analysis. BMC Musculoskelet. Disord., 22.","DOI":"10.1186\/s12891-021-04037-7"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1002\/mus.27384","article-title":"Different trajectories in upper limb and gross motor function in spinal muscular atrophy","volume":"64","author":"Coratti","year":"2021","journal-title":"Muscle Nerve"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jcm.2020.07.003","article-title":"The proprioceptive neuromuscular facilitation concept in parkinson disease: A systematic review and meta-analysis","volume":"19","author":"Luvizutto","year":"2020","journal-title":"J. Chiropr. Med."},{"key":"ref_72","unstructured":"Adler, S.S., Beckers, D., and Buck, M. (2007). PNF in Practice: An Illustrated Guide, Springer."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"391","DOI":"10.15406\/mojap.2018.05.00232","article-title":"PNF in acute stroke","volume":"5","author":"Chaturvedi","year":"2018","journal-title":"MOJ Anat. Physiol."},{"key":"ref_74","first-page":"263","article-title":"A review of technological and clinical aspects of robot-aided rehabilitation of upper-extremity after stroke","volume":"11","author":"Babaiasl","year":"2016","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.cnc.2019.11.004","article-title":"Stroke rehabilitation","volume":"32","year":"2020","journal-title":"Crit. Care Nurs. Clin."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1080\/10749357.2021.1943797","article-title":"A scoping review of design requirements for a home-based upper limb rehabilitation robot for stroke","volume":"29","author":"Li","year":"2022","journal-title":"Top. Stroke Rehabil."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Casals, A. (2013). Adaptive control in neurorehabilitation. Converging Clinical and Engineering Research on Neurorehabilitation, Springer.","DOI":"10.1007\/978-3-642-34546-3_20"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/1743-0003-11-3","article-title":"A survey on robotic devices for upper limb rehabilitation","volume":"11","author":"Maciejasz","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_79","first-page":"42","article-title":"Clinical Demands of Designs for Rehabilitation Robots in Taiwan","volume":"1","author":"Yeh","year":"2022","journal-title":"Innovation"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1017\/S0263574703005320","article-title":"Design and control of a three degree of freedom pneumatic physiotherapy robot","volume":"21","author":"Richardson","year":"2003","journal-title":"Robotica"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.mechatronics.2017.12.001","article-title":"Hybrid impedance control of a robot manipulator for wrist and forearm rehabilitation: Performance analysis and clinical results","volume":"49","author":"Aktan","year":"2018","journal-title":"Mechatronics"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1682\/JRRD.2005.02.0052","article-title":"Machines to support motor rehabilitation after stroke: 10 years of experience in Berlin","volume":"43","author":"Hesse","year":"2006","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Loureiro, R.C., and Harwin, W.S. (2007, January 13\u201315). Reach & grasp therapy: Design and control of a 9-DOF robotic neuro-rehabilitation system. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics, Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428510"},{"key":"ref_84","unstructured":"T\u00f3th, A., Arz, G., Fazekas, G., Bratanov, D., and Zlatov, N. (2004). 25 Post stroke shoulder-elbow physiotherapy with industrial robots. Advances in Rehabilitation Robotics: Human-Friendly Technologies on Movement Assistance and Restoration for People with Disabilities, Springer."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Yao, J., Sheaff, C., and Dewald, J.P. (2007, January 12\u201315). Usage of the ACT 3D Robot in a Brain Machine Interface for Hand Opening and Closing in Stroke Survivors. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics, Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428536"},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Huang, X., Naghdy, F., Du, H., Naghdy, G., and Todd, C. (2018). Temporal difference (TD) based critic-actor adaptive control for a fine hand motion rehabilitation robot. Mechatronics and Machine Vision in Practice 3, Springer.","DOI":"10.1007\/978-3-319-76947-9_14"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"4765","DOI":"10.1007\/s12008-024-01735-z","article-title":"Understanding human\u2013robot interaction forces: A new mechanical solution","volume":"18","author":"Pippo","year":"2024","journal-title":"Int. J. Interact. Des. Manuf. (IJIDeM)"},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Fareh, R., Elsabe, A., Baziyad, M., Kawser, T., Brahmi, B., and Rahman, M.H. (2023). Will your next therapist be a robot?\u2014A review of the advancements in robotic upper extremity rehabilitation. Sensors, 23.","DOI":"10.3390\/s23115054"},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Li, M., Zhang, J., Zuo, G., Feng, G., and Zhang, X. (2022). Assist-as-needed control strategy of bilateral upper limb rehabilitation robot based on GMM. Machines, 10.","DOI":"10.3390\/machines10020076"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1186\/s10033-024-01056-y","article-title":"Assistive Robotics for Upper Limb Physical Rehabilitation: A Systematic Review and Future Prospects","volume":"37","author":"Guatibonza","year":"2024","journal-title":"Chin. J. Mech. Eng."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"203382","DOI":"10.1109\/ACCESS.2020.3036596","article-title":"Review of control methods for upper limb telerehabilitation with robotic exoskeletons","volume":"8","author":"Bauer","year":"2020","journal-title":"IEEE Access"},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"17298806221118855","DOI":"10.1177\/17298806221118855","article-title":"A novel end-effector upper limb rehabilitation robot: Kinematics modeling based on dual quaternion and low-speed spiral motion tracking control","volume":"19","author":"Li","year":"2022","journal-title":"Int. J. Adv. Robot. Syst."},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Maithani, H., Ramon, J.A.C., and Mezouar, Y. (2019, January 16\u201319). Predicting human intent for cooperative physical human-robot interaction tasks. Proceedings of the 2019 IEEE 15th International Conference on Control and Automation (ICCA), Edinburgh, UK.","DOI":"10.1109\/ICCA.2019.8899490"},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Khan, M.M.R., Swapnil, A.A.Z., Ahmed, T., Rahman, M.M., Islam, M.R., Brahmi, B., Fareh, R., and Rahman, M.H. (2022). Development of an end-effector type therapeutic robot with sliding mode control for upper-limb rehabilitation. Robotics, 11.","DOI":"10.3390\/robotics11050098"},{"key":"ref_95","unstructured":"Wang, J., and Li, Y. (2010, January 21\u201324). Hybrid impedance control of a 3-DOF robotic arm used for rehabilitation treatment. Proceedings of the 2010 IEEE International Conference on Automation Science and Engineering, Toronto, ON, Canada."},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Papaleo, E., Zollo, L., Spedaliere, L., and Guglielmelli, E. (2013, January 6\u201310). Patient-tailored adaptive robotic system for upper-limb rehabilitation. Proceedings of the 2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany.","DOI":"10.1109\/ICRA.2013.6631120"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1109\/TRO.2015.2392451","article-title":"Passivity and stability of human\u2013robot interaction control for upper-limb rehabilitation robots","volume":"31","author":"Zhang","year":"2015","journal-title":"IEEE Trans. Robot."},{"key":"ref_98","doi-asserted-by":"crossref","unstructured":"Luo, L., Peng, L., Hou, Z., and Wang, W. (2017, January 5\u20138). An adaptive impedance controller for upper limb rehabilitation based on estimation of patients\u2019 stiffness. Proceedings of the 2017 IEEE International Conference on Robotics and Biomimetics (ROBIO), Macau, China.","DOI":"10.1109\/ROBIO.2017.8324471"},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Li, X., Liu, Y.H., and Yu, H. (2018, January 4\u20138). Adaptive impedance control for compliantly actuated robots with a unified safety measure. Proceedings of the 2018 13th World Congress on Intelligent Control and Automation (WCICA), Changsha, China.","DOI":"10.1109\/WCICA.2018.8630718"},{"key":"ref_100","doi-asserted-by":"crossref","unstructured":"Zhang, L., Guo, S., and Sun, Q. (2020). Development and assist-as-needed control of an end-effector upper limb rehabilitation robot. Appl. Sci., 10.","DOI":"10.3390\/app10196684"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"102919","DOI":"10.1016\/j.mechatronics.2022.102919","article-title":"Performance-based assistance control for robot-mediated upper-limbs rehabilitation","volume":"89","author":"Zhang","year":"2023","journal-title":"Mechatronics"},{"key":"ref_102","doi-asserted-by":"crossref","unstructured":"Guatibonza, A., Solaque, L., Velasco, A., and Penuela, L. (2021, January 6\u20138). Hybrid Impedance and Nonlinear Adaptive Control for a 7-DoF Upper Limb Rehabilitation Robot: Formulation and Stability Analysis. Proceedings of the ICINCO, Paris, France.","DOI":"10.5220\/0010579200002994"},{"key":"ref_103","doi-asserted-by":"crossref","unstructured":"Sidek, S.N., and Fatai, S. (2022). Design and Control of a 3D Robot-Assisted Rehabilitation Device for Post-Stroke. Control Engineering in Robotics and Industrial Automation: Malaysian Society for Automatic Control Engineers (MACE) Technical Series 2018, Springer.","DOI":"10.1007\/978-3-030-74540-0_2"},{"key":"ref_104","doi-asserted-by":"crossref","unstructured":"Arantes, A.P., Bressan, N., Borges, L.R., and McGibbon, C.A. (2023). Evaluation of a novel real-time adaptive assist-as-needed controller for robot-assisted upper extremity rehabilitation following stroke. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0292627"},{"key":"ref_105","doi-asserted-by":"crossref","unstructured":"Mathavan Jeyabalan, P.K., Nehrujee, A., Elias, S., Magesh Kumar, M., Sujatha, S., and Balasubramanian, S. (2023). Design and Characterization of a Self-Aligning End-Effector Robot for Single-Joint Arm Movement Rehabilitation. Robotics, 12.","DOI":"10.20944\/preprints202307.2117.v1"},{"key":"ref_106","doi-asserted-by":"crossref","unstructured":"Lai, Y., Sutjipto, S., Clout, M.D., Carmichael, M.G., and Paul, G. (2018, January 12\u201315). GAVRe 2: Towards data-driven upper-limb rehabilitation with adaptive-feedback gamification. Proceedings of the 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO), Kuala Lumpur, Malaysia.","DOI":"10.1109\/ROBIO.2018.8665105"},{"key":"ref_107","doi-asserted-by":"crossref","unstructured":"Mashayekhi, M., and Moghaddam, M.M. (2022). EMG-driven fatigue-based self-adapting admittance control of a hand rehabilitation robot. J. Biomech., 138.","DOI":"10.1016\/j.jbiomech.2022.111104"},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"104701","DOI":"10.1016\/j.robot.2024.104701","article-title":"Compensation-corrective adaptive control strategy for upper-limb rehabilitation robots","volume":"177","author":"Cai","year":"2024","journal-title":"Robot. Auton. Syst."},{"key":"ref_109","doi-asserted-by":"crossref","unstructured":"Xu, G., and Song, A. (2009, January 9\u201311). Adaptive impedance control based on dynamic recurrent fuzzy neural network for upper-limb rehabilitation robot. Proceedings of the 2009 IEEE International Conference on Control and Automation, Christchurch, New Zealand.","DOI":"10.1109\/ICCA.2009.5410286"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s10846-010-9462-3","article-title":"Adaptive impedance control for upper-limb rehabilitation robot using evolutionary dynamic recurrent fuzzy neural network","volume":"62","author":"Xu","year":"2011","journal-title":"J. Intell. Robot. Syst."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1163\/016918610X538561","article-title":"Control system design for an upper-limb rehabilitation robot","volume":"25","author":"Xu","year":"2011","journal-title":"Adv. Robot."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"106465","DOI":"10.1016\/j.compeleceng.2019.106465","article-title":"A novel backstepping adaptive impedance control for an upper limb rehabilitation robot","volume":"80","author":"Bai","year":"2019","journal-title":"Comput. Electr. Eng."},{"key":"ref_113","doi-asserted-by":"crossref","unstructured":"Wang, C., Peng, L., Hou, Z.G., Wang, W., and Su, T. (2019, January 6\u20139). A novel assist-as-needed controller based on fuzzy-logic inference and human impedance identification for upper-limb rehabilitation. Proceedings of the 2019 IEEE Symposium Series on Computational Intelligence (SSCI), Xiamen, China.","DOI":"10.1109\/SSCI44817.2019.9002868"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1109\/TBME.2020.3027823","article-title":"Performance-based hybrid control of a cable-driven upper-limb rehabilitation robot","volume":"68","author":"Li","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_115","doi-asserted-by":"crossref","unstructured":"Hu, Y., Meng, J., Li, G., Zhao, D., Feng, G., Zuo, G., Liu, Y., Zhang, J., and Shi, C. (2023). Fuzzy Adaptive Passive Control Strategy Design for Upper-Limb End-Effector Rehabilitation Robot. Sensors, 23.","DOI":"10.3390\/s23084042"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"123807","DOI":"10.1109\/ACCESS.2019.2938566","article-title":"Adaptive admittance control of an upper extremity rehabilitation robot with neural-network-based disturbance observer","volume":"7","author":"Wu","year":"2019","journal-title":"IEEE Access"},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Ting, W., and Aiguo, S. (2019). An adaptive iterative learning based impedance control for robot-aided upper-limb passive rehabilitation. Front. Robot. AI, 6.","DOI":"10.3389\/frobt.2019.00041"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"2031","DOI":"10.1109\/TCDS.2021.3072096","article-title":"Performance-based iterative learning control for task-oriented rehabilitation: A pilot study in robot-assisted bilateral training","volume":"15","author":"Miao","year":"2021","journal-title":"IEEE Trans. Cogn. Dev. Syst."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"110396","DOI":"10.1109\/ACCESS.2021.3102107","article-title":"Cable driven rehabilitation robots: Comparison of applications and control strategies","volume":"9","author":"Shoaib","year":"2021","journal-title":"IEEE Access"},{"key":"ref_120","doi-asserted-by":"crossref","unstructured":"Hashemi, A., and McPhee, J. (2021, January 1\u20135). Assistive sliding mode control of a rehabilitation robot with automatic weight adjustment. Proceedings of the 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Virtual.","DOI":"10.1109\/EMBC46164.2021.9631110"},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1109\/LRA.2020.3043197","article-title":"Development of an intention-based adaptive neural cooperative control strategy for upper-limb robotic rehabilitation","volume":"6","author":"Wu","year":"2020","journal-title":"IEEE Robot. Autom. Lett."},{"key":"ref_122","first-page":"832","article-title":"Event-triggered adaptive control for upper-limb robot-assisted passive rehabilitation exercises with input delay","volume":"236","author":"Abbas","year":"2022","journal-title":"Proc. Inst. Mech. Eng. Part I J. Syst. Control Eng."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"4628","DOI":"10.1177\/09544062231208722","article-title":"Event-triggered adaptive control for upper-extremity therapeutic robot in active-assist mode: A simulation study","volume":"238","author":"Abbas","year":"2024","journal-title":"Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci."},{"key":"ref_124","doi-asserted-by":"crossref","unstructured":"Sharifi, M., Behzadipour, S., and Vossoughi, G. (2012, January 24\u201327). Model reference adaptive impedance control of rehabilitation robots in operational space. Proceedings of the 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), Rome, Italy.","DOI":"10.1109\/BioRob.2012.6290690"},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1080\/01691864.2014.933125","article-title":"Model reference adaptive impedance control in Cartesian coordinates for physical human\u2013robot interaction","volume":"28","author":"Sharifi","year":"2014","journal-title":"Adv. Robot."},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1177\/09544119211054919","article-title":"Nonlinear time delay estimation based model reference adaptive impedance control for an upper-limb human-robot interaction","volume":"236","author":"Omrani","year":"2022","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"10-4172","DOI":"10.4172\/2168-9695.1000177","article-title":"A brief review on robotic exoskeletons for upper extremity rehabilitation to find the gap between research porotype and commercial type","volume":"6","author":"Islam","year":"2017","journal-title":"Adv. Robot. Autom."}],"container-title":["Robotics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2218-6581\/13\/12\/181\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:54:59Z","timestamp":1760115299000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2218-6581\/13\/12\/181"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,18]]},"references-count":127,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["robotics13120181"],"URL":"https:\/\/doi.org\/10.3390\/robotics13120181","relation":{},"ISSN":["2218-6581"],"issn-type":[{"value":"2218-6581","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,18]]}}}