{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T20:28:36Z","timestamp":1793132916210,"version":"4.5.0"},"reference-count":105,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2014,4,14]],"date-time":"2014-04-14T00:00:00Z","timestamp":1397433600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics"],"abstract":"<jats:p>It is a general assumption that pneumatic muscle-type actuators will play an important role in the development of an assistive rehabilitation robotics system. In the last decade, the development of a pneumatic muscle actuated lower-limb leg orthosis has been rather slow compared to other types of actuated leg orthoses that use AC motors, DC motors, pneumatic cylinders, linear actuators, series elastic actuators (SEA) and brushless servomotors. However, recent years have shown that the interest in this field has grown exponentially, mainly due to the demand for a more compliant and interactive  human-robotics system. This paper presents a survey of existing lower-limb leg orthoses for rehabilitation, which implement pneumatic muscle-type actuators, such as McKibben artificial muscles, rubbertuators, air muscles, pneumatic artificial muscles (PAM) or pneumatic muscle actuators (PMA). It reviews all the currently existing lower-limb rehabilitation orthosis systems in terms of comparison and evaluation of the design, as well as the control scheme and strategy, with the aim of clarifying the current and on-going research in the lower-limb robotic rehabilitation field.<\/jats:p>","DOI":"10.3390\/robotics3020120","type":"journal-article","created":{"date-parts":[[2014,4,14]],"date-time":"2014-04-14T12:54:41Z","timestamp":1397480081000},"page":"120-148","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":117,"title":["Recent Trends in Lower-Limb Robotic Rehabilitation Orthosis: Control Scheme and Strategy for Pneumatic Muscle Actuated Gait Trainers"],"prefix":"10.3390","volume":"3","author":[{"given":"Mohd","family":"Dzahir","sequence":"first","affiliation":[{"name":"Shibaura Institute of Technology, Department of Bio-Science Engineering, 307 Fukasaku,  Minuma-ku, Saitama City, Saitama 337-8570, Japan"},{"name":"Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, UTM Skudai,  Johor Bahru 81310, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shin-ichiroh","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Shibaura Institute of Technology, Department of Bio-Science Engineering, 307 Fukasaku,  Minuma-ku, Saitama City, Saitama 337-8570, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,4,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1111\/j.1460-9568.1995.tb00686.x","article-title":"Laufband therapy based on \u201crules of spinal locomotion\u201d is effective in spinal cord injured persons","volume":"7","author":"Wernig","year":"1995","journal-title":"Eur. J. Neurosci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1038\/sj.sc.3100670","article-title":"Maintenance of locomotor abilities following laufband (treadmill) therapy in para- and tetraplegic persons: Follow-up studies","volume":"36","author":"Wernig","year":"1998","journal-title":"Spinal Cord"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2626","DOI":"10.1093\/brain\/awf273","article-title":"Locomotor activity in spinal man: Significance of afferent input from joint and load receptors","volume":"125","author":"Dietz","year":"2002","journal-title":"Brain"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1152\/japplphysiol.00942.2003","article-title":"Locomotor activity in spinal cord-injured persons","volume":"96","author":"Dietz","year":"2004","journal-title":"J. Appl. Physiol."},{"key":"ref_5","first-page":"759764:1","article-title":"Lower-limb robotic rehabilitation: Literature review and challenges","volume":"2011","author":"Gil","year":"2011","journal-title":"J. Robot."},{"key":"ref_6","first-page":"20:1","article-title":"Review of control strategies for robotic movement training after neurologic injury","volume":"6","author":"Reinkensmeyer","year":"2009","journal-title":"J. Neuro-Eng. Rehabil."},{"key":"ref_7","first-page":"1","article-title":"Towards more effective robotic gait training for stroke rehabilitation: A review","volume":"9","author":"Pennycott","year":"2012","journal-title":"J. Neuro-Eng. Rehabil."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1109\/TRO.2008.915453","article-title":"Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art","volume":"24","author":"Dollar","year":"2008","journal-title":"IEEE Transact. Robot."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1038\/sj.sc.3101154","article-title":"Driven gait orthosis for improvement of locomotor training in paraplegics patients. International Medical Society of Paraplegia","volume":"39","author":"Colombo","year":"2001","journal-title":"Spinal Cord"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1109\/TRA.2004.825515","article-title":"Automatic gait pattern adaptation algorithms for rehabilitation with a 4-DOF robotic orthosis","volume":"20","author":"Jazernik","year":"2004","journal-title":"IEEE Transact. Robot. Autom."},{"key":"ref_11","first-page":"1:1","article-title":"Biofeedback for robotic gait rehabilitation","volume":"4","author":"Lunenburger","year":"2007","journal-title":"J. Neuro-Eng. Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"734","DOI":"10.2340\/16501977-0422","article-title":"Improved walking ability and reduced therapeutic stress with an electromechanical gait device","volume":"41","author":"Freivogel","year":"2009","journal-title":"J. Rehabil. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1310\/tsr1803-269","article-title":"Robot-assisted gait training for patients with hemiparesis due to stroke","volume":"18","author":"Fisher","year":"2011","journal-title":"Top Stroke Rehabil."},{"key":"ref_14","unstructured":"West, R.G. (2004). Powered Gait Orthosis and Method of Utilizing SAME. (6689075), U.S. Patent."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1109\/TNSRE.2007.903919","article-title":"Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation","volume":"15","author":"Veneman","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1109\/MRA.2008.927689","article-title":"Compliant actuation of rehabilitation robots","volume":"15","author":"Vallery","year":"2008","journal-title":"IEEE Robot. Autom. Mag."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1109\/TNSRE.2008.2008280","article-title":"Robot assisted gait training with active leg exoskeleton (ALEX)","volume":"17","author":"Banala","year":"2009","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1109\/TMECH.2010.2041245","article-title":"Novel gait adaptation and neuromotor training results using an active leg exoskeleton","volume":"15","author":"Banala","year":"2010","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1109\/TNSRE.2012.2212914","article-title":"Design and evaluation of NEUROBike: A neuro-rehabilitative platform for bedridden post-strike patients","volume":"20","author":"Monaco","year":"2012","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Taherifar, A., Mousavi, M., Rassaf, A., Ghiasi, F., and Hadian, M.R. (2013, January 12\u201314). LOKOIRAN\u2014A novel robot for rehabilitation of spinal cord injury sand stroke patients. Proceedings of the RSI\/ISM International Conference on Robotics and Mechatronics, Tehran, Iran.","DOI":"10.1109\/ICRoM.2013.6510108"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1109\/TMECH.2013.2243915","article-title":"Robotic gait rehabilitation trainer","volume":"19","author":"Pietrusinski","year":"2014","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1109\/37.833638","article-title":"Modelling and control of McKibben artificial muscle robot actuators","volume":"20","author":"Tondu","year":"2000","journal-title":"IEEE Control Syst. Mag."},{"key":"ref_23","unstructured":"Caldwell, D.G., Razak, A., and Goodwin, M. (1993, January 18\u201321). Braided artificial muscle actuators. Proceedings of the IFAC, Southampton, UK."},{"key":"ref_24","unstructured":"Caldwell, D.G., Medrano-Cerda, G.A., and Goodwin, M. (1994, January 8\u201313). Characteristics and adaptive control of pneumatic muscle actuators for a robotic elbow. Proceedings of the International Conference Robotics Automation, San Diego, CA, USA."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1109\/37.341863","article-title":"Control of pneumatic muscle actuators","volume":"15","author":"Caldwell","year":"1995","journal-title":"IEEE Control Syst. Mag."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0957-4158(99)00071-9","article-title":"Biomimetic actuators: Polymeric pseudo muscular actuators and pneumatic muscle actuators for biological emulation","volume":"10","author":"Caldwell","year":"2000","journal-title":"Mechatronics"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1177\/0278364903022003006","article-title":"Enhanced modeling and performance in braided pneumatic muscle actuators","volume":"22","author":"Davis","year":"2003","journal-title":"Int. J. Robot. Res."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1177\/0278364906063227","article-title":"Braid effects on contractile range and friction modeling in pneumatic muscle actuators","volume":"25","author":"Davis","year":"2006","journal-title":"Int. J. Robot. Res."},{"key":"ref_29","unstructured":"Chou, C.P., and Hannaford, B. (1994, January 8\u201313). Static and dynamic characteristics of McKibben pneumatic artificial muscles. Proceedings of the IEEE International Conference Robotics Automation, San Diego, CA, USA."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1109\/70.481753","article-title":"Measurement and modeling of McKibben pneumatic artificial muscles","volume":"12","author":"Chou","year":"1996","journal-title":"IEEE Trans. Robot. Autom."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1111\/j.1525-1594.2008.00549.x","article-title":"Hip orthosis powered by pneumatic artificial muscle: Voluntary activation in absence of myoelectrical signal","volume":"32","author":"Nascimento","year":"2008","journal-title":"Artif. Organs"},{"key":"ref_32","unstructured":"Vimieiro, C.B.S., do Nascimento, B.G., Nagem, D.A.P., and Pinotti, M. (2005, January 18\u201319). Development of a hip orthosis using pneumatic artificial muscles. Proceeding of TMSi, S\u00e3o Paulo, Spain."},{"key":"ref_33","unstructured":"Bharadwaj, K., and Sugar, T.G. (2006, January 15\u201319). Kinematics of a robotic gait trainer for stroke rehabilitation. Proceedings of the IEEE International Conference on Robotics and Automation, Orlando, FL, USA."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/j.gaitpost.2005.05.004","article-title":"An improved powered ankle-foot orthosis using proportional myoelectric control","volume":"23","author":"Ferris","year":"2006","journal-title":"Gait Posture"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1123\/jab.21.2.189","article-title":"An ankle-foot orthosis powered by artificial pneumatic muscles","volume":"21","author":"Ferris","year":"2005","journal-title":"J. Appl. Biomech."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1016\/j.jbiomech.2005.05.018","article-title":"Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis","volume":"39","author":"Gordon","year":"2006","journal-title":"J. Biomech."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s11633-006-0271-x","article-title":"Joint motion control of a powered lower limb orthosis for rehabilitation","volume":"3","author":"Costa","year":"2006","journal-title":"Int. J. Autom. Comput."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1080\/09638280701191826","article-title":"Robotic gait trainer in water: Development of an underwater gait-training orthosis","volume":"30","author":"Miyoshi","year":"2008","journal-title":"Disabil. Rehabil."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.gaitpost.2009.06.002","article-title":"Experimental study on the role of the ankle push off in the walk-to-run transition by means of a powered ankle-foot-exoskeleton","volume":"30","author":"Malcom","year":"2009","journal-title":"Gait Posture"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.gaitpost.2008.05.016","article-title":"Experimental study of the influence of the m. tibialis anterior on the walk-to-run transition by means of a powered ankle-foot-exoskeleton","volume":"29","author":"Malcom","year":"2009","journal-title":"Gait Posture"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/j.gaitpost.2013.01.029","article-title":"Adaptation to walking with an exoskeleton that assists ankle extension","volume":"38","author":"Galle","year":"2013","journal-title":"Gait Posture"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"0056137","DOI":"10.1371\/journal.pone.0056137","article-title":"A simple exoskeleton that assist plantarflexion can reduce the metabolic cost of human walking","volume":"8","author":"Malcom","year":"2013","journal-title":"PLoS One"},{"key":"ref_43","first-page":"23:1","article-title":"A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition","volume":"6","author":"Sawicki","year":"2009","journal-title":"J. Neuro-Eng. Rehabil."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Deaconescu, T.T., and Deaconescu, A.I. (2009). Pneumatic muscle actuated equipment for continuous passive motion. IAENG Trans. Eng. Technol.","DOI":"10.1063\/1.3256258"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.mechatronics.2010.07.004","article-title":"Control of McKibben pneumatic muscles for a power-assist, lower-limb orthosis","volume":"20","author":"Yeh","year":"2010","journal-title":"Mechatronics"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Carberry, J., Hinchly, G., Buckerfield, J., Taylor, E., Burton, T., Madgwick, S., and Vaidyanathan, R. (2011, January 27\u201330). Parametric design of an active ankle foot orthosis with passive compliance. Proceedings of the Computer-Based Medical System (CBMS), Bristol, UK.","DOI":"10.1109\/CBMS.2011.5999151"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Park, Y., Chen, B., Young, D., Stirling, L., Wood, R., Goldfield, E., and Nagpal, R. (2011, January 25\u201330). Bio-inspired Active Soft Orthotic Device for Ankle Foot Pathologies. Proceedings of the International Conference on Robots and Systems (IROS), San Francisco, CA, USA.","DOI":"10.1109\/IROS.2011.6094933"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Park, Y., Chen, B., Majidi, C., Wood, R., Nagpal, R., and Goldfield, E. (2012, January 7\u201312). Active Modular Elastomer Sleeve for Soft Wearable Assistance Robots. Proceedings of the IEEE International Conference on Robots and Systems (IROS), Vilamoura, Portugal.","DOI":"10.1109\/IROS.2012.6386158"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Teng, C.M., Wong, Z.Y., The, W.Y., and Chong, Y.Z. (2012, January 27\u201328). Design and development of inexpensive pneumatically-powered assisted knee-ankle-foot orthosis for gait rehabilitation-preliminary finding. Proceedings of the International Conference on Biomedical Engineering (ICoBE), Penang, Malaysia.","DOI":"10.1109\/ICoBE.2012.6178949"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Kawamura, T., and Takanaka, K. (2013, January 24\u201326). Development of an orthosis for walking assistance using pneumatic artificial muscle-a quantitative assessment of the effect of assistance. Proceedings of the International Conference on Rehabilitation Robotics, Seattle, WA, USA.","DOI":"10.1109\/ICORR.2013.6650350"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1109\/TSMCB.2012.2222374","article-title":"Adaptive impedance control of a robotic orthosis for gait rehabilitation","volume":"43","author":"Hussain","year":"2013","journal-title":"IEEE Trans. Cybern."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1109\/TSMCA.2012.2207111","article-title":"Robust nonlinear control of an intrinsically compliant robotic gait training orthosis","volume":"43","author":"Hussain","year":"2013","journal-title":"IEEE Trans. Syst. Man Cybern.: Syst."},{"key":"ref_53","unstructured":"Caldwell, D.G., Medrano-Cerda, G.A., and Goodwin, M.J. (1993, January 17\u201320). Braided pneumatic actuator control of a multi jointed manipulator. Proceedings of the International Conference on System, Man and Cybernetics, Le Touquet, France."},{"key":"ref_54","unstructured":"Caldwell, D.G., Medrano-Cerda, G.A., and Goodwin, M. (1994, January 8\u201313). Characteristics and adaptive control of pneumatic muscle actuators for a robotic elbow. Proceedings of the International Conference on Robotics and Automation, San Diego, CA, USA."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1109\/37.341863","article-title":"Control of a pneumatic muscle actuators","volume":"15","author":"Caldwell","year":"1995","journal-title":"IEEE Trans. Control Syst."},{"key":"ref_56","unstructured":"Medrano-Cerda, G.A., Bowler, C.J., and Caldwell, D.G. (1995, January 5\u20139). Adaptive position control of antagonistic pneumatic muscle actuators. Proceedings of the International Conference on Intelligent Robots and Systems,  Pittsburgh, PA, USA."},{"key":"ref_57","unstructured":"Hamerlain, M. (, January 5\u20139). An anthropomorphic robot arm driven by artificial muscles using a variable structure control. Proceedings of the International Conference on Intelligent Robots and Systems, Pittsburgh, PA, USA."},{"key":"ref_58","unstructured":"Iskarous, M., and Kawamura, K. (1995, January 5\u20139). Intelligent control using a neuro-fuzzy network. Proceedings of the International Conference on Intelligent Robots and Systems, Pittsburgh, PA, USA."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1007\/s004220050308","article-title":"Analysis and control of a rubbertuator arm","volume":"75","author":"Groen","year":"1996","journal-title":"Biol. Cybern."},{"key":"ref_60","unstructured":"Cai, D., and Yamaura, H. (1996, January 15\u201318). A robust controller for manipulator driven by artificial muscle actuator. Proceedings of the IEEE International Conference on Control Applications, Dearborn, MI, USA."},{"key":"ref_61","first-page":"1","article-title":"Pneumatic muscle actuators: Musculature for an anthropomorphic robot arm","volume":"8","author":"Bowler","year":"1996","journal-title":"IEEE Colloq. Actuator Technol."},{"key":"ref_62","unstructured":"Repperger, D.W., Johnson, K.R., and Phillips, C.A. (1999, January 2\u20134). Nonlinear feedback controller design of a pneumatic muscle actuator system. Proceedings of the American Control Conference, San Diego, CA, USA."},{"key":"ref_63","unstructured":"Carbonell, P., Jiang, Z.P., and Repperger, D.W. (2001, January 5\u20137). Nonlinear control of a pneumatic muscle actuator: Backstepping vs. Sliding-mode. Proceedings of the IEEE International Conference on Control Applications, Mexico City, Mexico."},{"key":"ref_64","unstructured":"Carbonell, P., Jiang, Z.P., and Repperger, D.W. (2001, January 5\u20137). A fuzzy backstepping controller for a pneumatic muscle actuator system. Proceedings of the IEEE International Symposium on Intelligent Control, Mexico City, Mexico."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Folgheraiter, M., Gini, G., Perkowski, M., and Pivtoraiko, M. (2003, January 1\u20133). Adaptive reflex control for an artificial hand. Proceedings of the SYROCO, Wroc\u0142aw, Poland.","DOI":"10.1016\/j.biosystems.2004.05.007"},{"key":"ref_66","unstructured":"Balasubramanian, K., and Rattan, K.S. (2003, January 25\u201328). Feedforward control of a non-linear pneumatic muscle system using fuzzy logic. Proceedings of the IEEE International Conference on Fuzzy Systems, St. Louis, MO, USA."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1007\/BF02984253","article-title":"Improvement of the control performance of pneumatic artificial muscle manipulators using an intelligent switching control method","volume":"18","author":"Ahn","year":"2004","journal-title":"KSME Int. J."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1007\/BF02916109","article-title":"Nonlinear PID control to improve the control performance of the pneumatic artificial muscle manipulator using neural network","volume":"19","author":"Ahn","year":"2005","journal-title":"J. Mech. Sci. Technol."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"3855","DOI":"10.1109\/TIE.2008.2003202","article-title":"Sliding-mode control of a high-speed linear axis driven by pneumatic muscle actuators","volume":"55","author":"Aschemann","year":"2008","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s12541-009-0091-3","article-title":"Trajectory tracking control of a pneumatic c-y table using neural network based PID control","volume":"10","author":"Cho","year":"2009","journal-title":"Int. J. Precis. Eng. Manuf."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2058","DOI":"10.1049\/iet-cta.2009.0555","article-title":"Tracking control of pneumatic artificial muscle actuators based on sliding mode and non-linear disturbance observer","volume":"10","author":"Xing","year":"2010","journal-title":"IET Control Theory Appl."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1109\/TAC.1984.1103644","article-title":"Adaptive control of mechanical impedance by coactivation of antagonist muscles","volume":"29","author":"Hogan","year":"1984","journal-title":"IEEE Trans. Autom. Control"},{"key":"ref_73","unstructured":"Murray, W.R. (1988, January 10\u201311). Modelling elbow equilibrium in the presence of co-contraction. Proceedings of the Bioengineering Conference, Durham, NH, USA."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Murray, W.R., and Hogan, N. (1988, January 4\u20137). Co-contraction of antagonist muscles: Prediction and observation. Proceedings of the Joint Dynamics and ControlIEEE International Conference on Engineering in Medicine and Biology Society (EMBS), New Orleans, LA, USA.","DOI":"10.1109\/IEMBS.1988.95236"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1115\/1.2429699","article-title":"Novel nonlinear elastic actuators for passively controlling robotic joint compliance","volume":"129","author":"Migliore","year":"2007","journal-title":"Trans. ASME"},{"key":"ref_76","unstructured":"Schepelmann, A., Taylor, M.D., and Geyer, H. (2013). Robotics: Science and Systems VIII, University of Sydney."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Laffranchi, M., Tsagarakis, N.G., Cannella, F., and Caldwell, D.G. (2009, January 10\u201315). Antagonistic and series elastic actuators: A comparative analysis on the energy consumption. Proceedings of the IEEE\/RSJ International Conference on Intelligent Robots and Systems, St. Louis, MO, USA.","DOI":"10.1109\/IROS.2009.5354349"},{"key":"ref_78","unstructured":"Klauer, C., Raisch, J., and Schauer, T. (2013, January 14\u201315). Advanced control strategies for neuro-prosthetic systems. Proceedings of the Technically Assisted Rehabilitation (TAR), Berlin, Germany."},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Mitrovic, D., Klanke, S., Osu, R., Kawato, M., and Vijayakumar, S. (2010). A computational model of limb impedance control based on principles of internal model uncertainty. PLoS One.","DOI":"10.1371\/journal.pone.0013601"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S1050-6411(01)00034-7","article-title":"Relationship between antagonistic leg muscles co-contraction and body centre of gravity mechanics in different level gait disorders","volume":"12","author":"Dierick","year":"2002","journal-title":"J. Electromyogr.Kinesiol."},{"key":"ref_81","unstructured":"Milner, T.E., and Cloutier, C. (1995, January 20\u201323). The effect of antagonist muscle co-contraction on damping of the wrist joint during voluntary movement. Proceedings of the IEEE 17th Annual Conference on Engineering in Medicine and Biology Society, Montreal, Canada."},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Hollerbach, K., Ramos, C.F., and Kazerooni, H. (1993, January 2\u20134). Destabilizing effects of muscular co-contraction in human-machine interaction. Proceedings of the American Control Conference, San Francisco, CA, USA.","DOI":"10.23919\/ACC.1993.4792957"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Fu, C., and Wang, R. (2009, January 11\u201313). The influence of co-contraction to the arm impedance during free planar movement. Proceedings of the International Conference on Bioinformatics and Biomedical Engineering (ICBBE), Beijing, China.","DOI":"10.1109\/ICBBE.2009.5163625"},{"key":"ref_84","unstructured":"Lynch, C.L., Sayenko, D., and Popovic, M.R. (September, January 28). Co-contraction of antagonist muscles during knee extension against gravity: Insights for functional electrical simulation control design. Proceedings of the IEEE International Conference on Engineering in Medicine and Biology Society (EMBS), San Diego, California, USA."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Odhner, L., and Asada, H. (2008, January 19\u201322). Equilibrium point control of artificial muscles using recruitment of many motor units. Proceedings of the IEEE\/RAS International Conference on Biomedical Robotics and Biomechatronics, Scottsdale, AZ, USA.","DOI":"10.1109\/BIOROB.2008.4762884"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/s00221-007-1264-x","article-title":"The role of cocontraction in the impairment of movement accuracy with fatigue","volume":"185","author":"Missenard","year":"2008","journal-title":"Exp. Brain Res."},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Klauer, C., Raisch, J., and Schauer, T. (2013, January 17\u201319). Nonlinear joint-angle feedback control of electrically simulated and \u03bb-controlled antagonistic muscle pairs. Proceedings of the European Control Conference (ECC), Zurich, Switzerland.","DOI":"10.23919\/ECC.2013.6669669"},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Spagnol, P., Klauer, C., Previdi, F., Raisch, J., and Schauer, T. (2013, January 17\u201319). Modelling and online-identification of electrically stimulated antagonistic muscles for horizontal shoulder abduction and adduction. Proceedings of the European Control Conference (ECC), Zurich, Switzerland.","DOI":"10.23919\/ECC.2013.6669599"},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Ferris, D.P., and Lewis, C.L. (2009, January 2\u20136). Robotic lower limb exoskeletons using proportional myoelectric control. Proceedings of the IEEE International Conference on Engineering in Medicine and Biology Society (EMBS), Minneapolis, MN, USA.","DOI":"10.1109\/IEMBS.2009.5333984"},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Mankala, K.K., Banala, S.K., and Agrawal, S.K. (2007, January 10\u201314). Passive swing assistive exoskeletons for motor-incomplete spinal cord injury patients. Proceedings of the IEEE International Conference on Robotics and Automation, Roma, Italy.","DOI":"10.1109\/ROBOT.2007.364055"},{"key":"ref_91","unstructured":"Kumamoto, M., Oshima, T., and Fujukawa, T. (2000, January 27\u201329). Control properties of a two-joint link mechanism equipped with mono- and bi-articular actuators. Proceedings of the IEEE International Workshop on Robot and Human Interactive Communication, Osaka, Japan."},{"key":"ref_92","unstructured":"Shimizu, S., Momose, N., Oshima, T., and Koyanagi, K. (October, January 27). Development of robot leg which provided with the bi-articular actuator for training techniques of rehabilitation. Proceedings of the IEEE International Symposium on Robot and Human Interactive Communication, Toyama, Japan."},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Salvucci, V., Oh, S., and Hori, Y. (2010, January 7\u201310). Infinity norm approach for precise force control of manipulators driven by bi-articular actuators. Proceedings of the Annual Conference on IEEE Industrial Electronics Society, Glendale, AZ, USA.","DOI":"10.1109\/IECON.2010.5675356"},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Salvucci, V., Oh, S., Hori, Y., and Kimura, Y. (2011, January 27\u201330). Disturbance rejection improvement in non-redundant robot arms using bi-articular actuators. Proceedings of the Industrial Electronics (ISIE), Gda\u0144sk, Poland.","DOI":"10.1109\/ISIE.2011.5984495"},{"key":"ref_95","unstructured":"Salvucci, V., Kimura, Y., Oh, Y., and Hori, Y. (July, January 29). Experimental verification of infinity norm approach for force maximization of manipulators driven by bi-articular actuators. Proceedings of the American Control Conference on O\u2019Farrell Street, San Francisco, CA, USA."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s00422-005-0015-y","article-title":"Can co-activation reduce kinematics variability? A simulation study","volume":"93","author":"Selen","year":"2005","journal-title":"Biol. Cybern."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1109\/10.19852","article-title":"Task-based methods for evaluating electrically stimulated antagonist muscle controllers","volume":"36","author":"Durfee","year":"1989","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_98","unstructured":"Mohammed, S., Fraisse, P., Guiraud, D., Poignet, P., and el Makssoud, H. (2005, January 12\u201315). Towards a co-contraction muscle control strategy for paraplegics. Proceedings of the 44th IEEE Conference on Decision and Control, Seville, Spain."},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Mohammed, S., Poignet, P., Fraisse, P., and Guiraud, D. (2010, January 26\u201329). Optimal stimulation patterns for knee joint movement restoration during co-contraction of antagonist muscles. Proceedings of the International Conference on Biomedical Robotics and Biomechatronics, Tokyo, Japan.","DOI":"10.1109\/BIOROB.2010.5626111"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"5:1","DOI":"10.3389\/fnbot.2011.00005","article-title":"Muscle co-contraction modulates damping and joint stability in a three-link biomechanical limb","volume":"5","author":"Heitmann","year":"2012","journal-title":"Front. Neurorobot."},{"key":"ref_101","doi-asserted-by":"crossref","unstructured":"Kawai, H., Murao, T., Sato, R., and Fujita, M. (2011, January 28\u201330). Passivity-based control for 2DOF robot manipulators with antagonistic bi-articular muscles. Proceedings of the IEEE International Conference on Control Applications (CCA), Denver, CO, USA.","DOI":"10.1109\/CCA.2011.6044445"},{"key":"ref_102","doi-asserted-by":"crossref","unstructured":"Kawai, K.S.H., Murao, T., and Fujita, M. (2012, January 3\u20135). Open-loop control for 2DOF robot manipulators with antagonistic bi-articular muscles. Proceedings of the IEEE International Conference on Control Applications (CCA), Dubrovnik, Croatia.","DOI":"10.1109\/CCA.2011.6044445"},{"key":"ref_103","doi-asserted-by":"crossref","unstructured":"Kawai, Y., Kawai, H., and Fujita, M. (2013, January 28\u201330). RISE control for 2DOF human lower limb with antagonistic bi-articular muscles. Proceedings of the IEEE International Conference on Control Applications (CCA), Hyderabad, India.","DOI":"10.1109\/CCA.2013.6662752"},{"key":"ref_104","doi-asserted-by":"crossref","unstructured":"Kawai, Y., Downey, R.J., Kawai, H., and Dixon, W.E. Co-Contraction of Antagonist Bi-Articular Muscles for Tracking Control of Human Limb. Available online:http:\/\/wwwr.kanazawa-it.ac.jp\/kawai\/research\/2013\/CDC13KaDoKaDi.pdf.","DOI":"10.1109\/ACC.2014.6859102"},{"key":"ref_105","unstructured":"Kawai, Y. A Design of Co-Contraction Level of Antagonist Muscles with Muscle Contraction Dynamics for Tracking Control of Human Limb. Available online:http:\/\/k-lab.e.ishikawa-nct.ac.jp\/paper\/2013\/SICE13_0447_FI.pdf."}],"container-title":["Robotics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2218-6581\/3\/2\/120\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:10:17Z","timestamp":1760217017000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2218-6581\/3\/2\/120"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,14]]},"references-count":105,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2014,6]]}},"alternative-id":["robotics3020120"],"URL":"https:\/\/doi.org\/10.3390\/robotics3020120","relation":{},"ISSN":["2218-6581"],"issn-type":[{"value":"2218-6581","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,14]]}}}