{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T05:59:23Z","timestamp":1773295163935,"version":"3.50.1"},"reference-count":15,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2017,1,25]],"date-time":"2017-01-25T00:00:00Z","timestamp":1485302400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"German Federal Ministry of Education and Research (BMBF)","award":["16SV6313"],"award-info":[{"award-number":["16SV6313"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics"],"abstract":"<jats:p>To offer a functionality that could not be found in traditional rigid robots, compliant actuators are in development worldwide for a variety of applications and especially for human\u2013robot interaction. Pneumatic bending actuators are a special kind of such actuators. Due to the absence of fixed mechanical axes and their soft behavior, these actuators generally possess a polycentric motion ability. This can be very useful to provide an implicit self-alignment to human joint axes in exoskeleton-like rehabilitation devices. As a possible realization, a novel bending actuator (BA) was developed using patented pneumatic skewed rotary elastic chambers (sREC). To analyze the actuator self-alignment properties, knowledge about the motion of this bending actuator type, the so-called skewed rotary elastic chambers bending actuator (sRECBA), is of high interest and this paper presents experimental and simulation-based kinematic investigations. First, to describe actuator motion, the finite helical axes (FHA) of basic actuator elements are determined using a three-dimensional (3D) camera system. Afterwards, a simplified two-dimensional (2D) kinematic simulation model based on a four-bar linkage was developed and the motion was compared to the experimental data by calculating the instantaneous center of rotation (ICR). The equivalent kinematic model of the sRECBA was realized using a series of four-bar linkages and the resulting ICR was analyzed in simulation. Finally, the FHA of the sRECBA were determined and analyzed for three different specific motions. The results show that the actuator\u2019s FHA adapt to different motions performed and it can be assumed that implicit self-alignment to the polycentric motion of the human joint axis will be provided.<\/jats:p>","DOI":"10.3390\/robotics6010002","type":"journal-article","created":{"date-parts":[[2017,1,25]],"date-time":"2017-01-25T09:50:44Z","timestamp":1485337844000},"page":"2","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Experimental and Simulation-Based Investigation of Polycentric Motion of an Inherent Compliant Pneumatic Bending Actuator with Skewed Rotary Elastic Chambers"],"prefix":"10.3390","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5813-5782","authenticated-orcid":false,"given":"Andr\u00e9","family":"Wilkening","sequence":"first","affiliation":[{"name":"Friedrich-Wilhelm-Bessel-Institute Research Company, D-28359 Bremen, Germany"},{"name":"Institute of Automation, University of Bremen, D-28359 Bremen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steffen","family":"Hacker","sequence":"additional","affiliation":[{"name":"Institute of Orthopaedic Research and Biomechanics, Ulm University\u2014Medical Center, D-89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henning","family":"St\u00f6ppler","sequence":"additional","affiliation":[{"name":"Friedrich-Wilhelm-Bessel-Institute Research Company, D-28359 Bremen, Germany"},{"name":"Institute of Automation, University of Bremen, D-28359 Bremen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5470-5423","authenticated-orcid":false,"given":"Lutz","family":"D\u00fcrselen","sequence":"additional","affiliation":[{"name":"Institute of Orthopaedic Research and Biomechanics, Ulm University\u2014Medical Center, D-89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oleg","family":"Ivlev","sequence":"additional","affiliation":[{"name":"Friedrich-Wilhelm-Bessel-Institute Research Company, D-28359 Bremen, Germany"},{"name":"Institute of Automation, University of Bremen, D-28359 Bremen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2017,1,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Vallery, H., Veneman, J., Asseldonk, E.V., Ekkelenkamp, R., Buss, M., and Kooij, H.V.D. (2008). Compliant actuation of rehabilitation robots. IEEE Robot. Autom. Mag., 15.","DOI":"10.1109\/MRA.2008.927689"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1109\/MRA.2004.1310939","article-title":"Fast and \u201cSoft-Arm\u201d Tactics","volume":"11","author":"Bicchi","year":"2004","journal-title":"IEEE Robot. Autom. Mag."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Ivlev, O. (2009, January 23\u201326). Soft fluidic actuators of rotary type for safe physical human-machine interaction. Proceedings of the 11th IEEE International Conference on Rehabilitation Robotics, Kyoto, Japan.","DOI":"10.1109\/ICORR.2009.5209571"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Celebi, B., Yalcin, M., and Patoglu, V. (2013, January 3\u20137). A self-aligning knee exoskeleton. Proceedings of the IEEE\/RSJ International Conference on Intelligent Robots and Systems, Tokyo, Japan.","DOI":"10.1109\/IROS.2013.6696472"},{"key":"ref_5","unstructured":"Cai, D.V.A., and Bidaud, P. (2014). Advances on Theory and Practice of Robots and Manipulators, Springer International Publishing."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Baiden, D., and Ivlev, O. (2014, January 3\u20135). Independent Torque and Stiffness Adjustment of a Pneumatic Direct Rotary Soft-Actuator for Adaptable Human-Robot-Interaction. Proceedings of the 23th IEEE International Conference on Robotics in Alpe-Adria-Danube Region (RAAD), Smolenice, Slovaki.","DOI":"10.1109\/RAAD.2014.7002257"},{"key":"ref_7","unstructured":"B\u00e4zner, H., V\u00fcllers, L., Baiden, D., and Ivlev, O. (2016, January 13\u201315). Novel assistive interactively controlled sit-to-stand trainer using multi-axial pneumatic soft-actuators\u2014Results of a pilot study in acute stroke patients. Proceedings of the ESC 2016\u201425th European Stroke Conference, Venice, Italy."},{"key":"ref_8","unstructured":"FWBI (2013). Soft-Fluidic Actuator Elements and Processes for Their Manufacturing. (Patent DE102011081727)."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1038\/nature14543","article-title":"Design, fabrication and control of soft robots","volume":"521","author":"Rus","year":"2015","journal-title":"Nature"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Wilkening, A., St\u00f6ppler, H., and Ivlev, O. (2015, January 11\u201314). Adaptive assistive control of a soft elbow trainer with self-alignment using pneumatic bending joint. Proceedings of the IEEE International Conference on Rehabilitation Robotics (ICORR), Singapore.","DOI":"10.1109\/ICORR.2015.7281288"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.jbiomech.2006.04.006","article-title":"The finite helical axis of the knee joint (a non-invasive in vivo study using fast-PC MRI)","volume":"40","author":"Sheehan","year":"2007","journal-title":"J. Biomech."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1016\/j.jbiomech.2008.03.018","article-title":"Helical axes of skeletal knee joint motion during running","volume":"41","author":"Reinschmidt","year":"2008","journal-title":"J. Biomech."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/0021-9290(80)90020-2","article-title":"Rigid body motion calculated from spatial co-ordinates of markers","volume":"13","author":"Spoor","year":"1980","journal-title":"J. Biomech."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1364\/JOSAA.4.000629","article-title":"Closed-form solution of absolute orientation using unit quaternions","volume":"4","author":"Horn","year":"1987","journal-title":"J. Opt. Soc. Am."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/0021-9290(79)90059-9","article-title":"Centers and angles of rotation of body joints: A study of errors and optimization","volume":"12","author":"Panjabi","year":"1997","journal-title":"J. Biomech."}],"container-title":["Robotics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2218-6581\/6\/1\/2\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:26:57Z","timestamp":1760207217000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2218-6581\/6\/1\/2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,25]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,3]]}},"alternative-id":["robotics6010002"],"URL":"https:\/\/doi.org\/10.3390\/robotics6010002","relation":{},"ISSN":["2218-6581"],"issn-type":[{"value":"2218-6581","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,25]]}}}