{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T11:56:53Z","timestamp":1775476613571,"version":"3.50.1"},"reference-count":70,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2019,6,14]],"date-time":"2019-06-14T00:00:00Z","timestamp":1560470400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004837","name":"Ministerio de Ciencia e Innovaci\u00f3n","doi-asserted-by":"publisher","award":["BIA2014-54291-R"],"award-info":[{"award-number":["BIA2014-54291-R"]}],"id":[{"id":"10.13039\/501100004837","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Remote Sensing"],"abstract":"<jats:p>Infrared thermography (IRT) techniques for building inspection are currently becoming increasingly popular as non-destructive methods that provide valuable information about surface temperature (ST) and ST contrast (delta-T). With the advent of unmanned aerial vehicle (UAV)-mounted thermal cameras, IRT technology is now endowed with improved flexibility from an aerial perspective for the study of building envelopes. A case study cellar in Northwest (NW) Spain is used to assess the capability and reliability of low-altitude passive IRT in evaluating a typical semi-buried building. The study comparatively assesses the use of a pole-mounted FLIR B335 camera and a drone-mounted FLIR Vue Pro R camera for this purpose. Both tested IRT systems demonstrate good effectiveness in detecting thermal anomalies (e.g., thermal bridges, air leakages, constructive singularities, and moisture in the walls of the cellar) but pose some difficulties in performing accurate ST measurements under real operating conditions. Working with UAVs gives great flexibility for the inspection, but the angle of view strongly influences the radiometric data captured and must be taken into account to avoid disturbances due to specular reflections.<\/jats:p>","DOI":"10.3390\/rs11121424","type":"journal-article","created":{"date-parts":[[2019,6,17]],"date-time":"2019-06-17T03:24:41Z","timestamp":1560741881000},"page":"1424","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["IR Thermography from UAVs to Monitor Thermal Anomalies in the Envelopes of Traditional Wine Cellars: Field Test"],"prefix":"10.3390","volume":"11","author":[{"given":"Juan","family":"Ortiz-Sanz","sequence":"first","affiliation":[{"name":"Agroforestry Engineering Department, University of Santiago de Compostela (USC), Higher Polytechnic School of Engineering, 27002 Lugo, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9037-9944","authenticated-orcid":false,"given":"Mariluz","family":"Gil-Docampo","sequence":"additional","affiliation":[{"name":"Agroforestry Engineering Department, University of Santiago de Compostela (USC), Higher Polytechnic School of Engineering, 27002 Lugo, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6474-8825","authenticated-orcid":false,"given":"Marcos","family":"Arza-Garc\u00eda","sequence":"additional","affiliation":[{"name":"Agroforestry Engineering Department, University of Santiago de Compostela (USC), Higher Polytechnic School of Engineering, 27002 Lugo, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6337-6377","authenticated-orcid":false,"given":"Ignacio","family":"Ca\u00f1as-Guerrero","sequence":"additional","affiliation":[{"name":"Agroforestry Engineering Department, Polytechnic University of Madrid (UPM), School of Agricultural, Food and Biosystems Engineering, 28040 Madrid, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2019,6,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.agwat.2016.01.004","article-title":"Effects of climate variability on irrigation scheduling in white varieties of Vitis vinifera (L.) of NW Spain","volume":"170","author":"Cancela","year":"2016","journal-title":"Agric. Water Manag."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.agsy.2016.12.009","article-title":"Evaluation of the effects of future climate change on grape quality through a physically based model application: A case study for the Aglianico grapevine in Campania region, Italy","volume":"152","author":"Bonfante","year":"2017","journal-title":"Agric. Syst."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1002\/jsfa.8656","article-title":"Effect of seasonal climate fluctuations on the evolution of glycoconjugates during the ripening period of grapevine cv. Muscat \u00e0 petits grains blancs berries","volume":"98","author":"Crespo","year":"2018","journal-title":"J. Sci. Food Agric."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.foodchem.2017.05.044","article-title":"The effect of ageing temperature on the physicochemical properties, phytochemical profile and \u03b1-glucosidase inhibition of Hibiscus sabdariffa (roselle) wine","volume":"267","author":"Ifie","year":"2018","journal-title":"Food Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1007\/s10295-011-1018-4","article-title":"Wine flavor and aroma","volume":"38","author":"Styger","year":"2011","journal-title":"J. Ind. Microbiol. Biotechnol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.buildenv.2015.01.005","article-title":"Indoor air temperature monitoring: A method lending support tomanagement and design tested on a wine-aging room","volume":"86","author":"Barbaresi","year":"2015","journal-title":"Build. Environ."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"19495","DOI":"10.3390\/s150819495","article-title":"Distributed wireless monitoring system for ullage and temperature in wine barrels","volume":"15","author":"Zhang","year":"2015","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Correia, J., Mour\u00e3o, A., and Cavique, M. (2017, January 24\u201327). Energy evaluation at a winery: A case study at a Portuguese producer. Proceedings of the IManE&E. MATEC Web of Conferences, Iasi, Romania.","DOI":"10.1051\/matecconf\/201711210001"},{"key":"ref_9","first-page":"54","article-title":"An assessment of using ground thermal inertia as passive thermal technique in the wine industry around the world","volume":"33\u201334","year":"2012","journal-title":"Appl. Therm. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.renene.2004.04.014","article-title":"Study of the thermal behaviour of traditional wine cellars: The case of the area of \u201cTierras Sorianas del Cid\u201d (Spain)","volume":"30","year":"2005","journal-title":"Renew. Energy"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.tust.2005.07.004","article-title":"Subterranean wine cellars of Central-Spain (Ribera de Duero): An underground built heritage to preserve","volume":"21","year":"2006","journal-title":"Tunn. Undergr. Sp. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1016\/j.renene.2009.03.002","article-title":"Seasonal analysis of the thermal behaviour of traditional underground wine cellars in Spain","volume":"34","year":"2009","journal-title":"Renew. Energy"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.apenergy.2011.11.075","article-title":"Predicted vs. actual energy performance of non-domestic buildings: Using post-occupancy evaluation data to reduce the performance gap","volume":"97","author":"Menezes","year":"2012","journal-title":"Appl. Energy"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.enbuild.2013.04.002","article-title":"Monitoring the performance of low energy dwellings: Two UK case studies","volume":"64","author":"Tweed","year":"2013","journal-title":"Energy Build."},{"key":"ref_15","unstructured":"Demanuele, C., Tweddell, T., and Davies, M. (2010, January 25\u201330). Bridging the gap between predicted and actual energy performance in schools. Proceedings of the World Renewable Energy Congress XI, Abu Dhabi, UAE."},{"key":"ref_16","unstructured":"Bordass, B., Cohen, R., and Field, J. (2004, January 2\u20133). Energy Performance of Non-Domestic Buildings: Closing the Credibility Gap. Proceedings of the 8th International Conference on Improving Energy Efficiency in Commercial Buildings, Frankfurt, Germany."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.autcon.2014.02.009","article-title":"The gap between predicted and measured energy performance of buildings: A framework for investigation","volume":"41","year":"2014","journal-title":"Autom. Constr."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.rser.2014.07.188","article-title":"Thermography methodologies for detecting energy related building defects","volume":"40","author":"Fox","year":"2014","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.buildenv.2018.09.050","article-title":"Quantification of heat energy losses through the building envelope: A state-of-the-art analysis with critical and comprehensive review on infrared thermography","volume":"146","author":"Nardi","year":"2018","journal-title":"Build. Environ."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3077","DOI":"10.1016\/j.rser.2017.10.031","article-title":"Applications of the infrared thermography in the energy audit of buildings: A review","volume":"82","author":"Lucchi","year":"2018","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.enbuild.2018.07.052","article-title":"A review of infrared thermography for the investigation of building envelopes: Advances and prospects","volume":"176","author":"Kirimtat","year":"2018","journal-title":"Energy Build."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/j.apenergy.2014.08.005","article-title":"Infrared thermography (IRT) applications for building diagnostics: A review","volume":"134","author":"Kylili","year":"2014","journal-title":"Appl. Energy"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1016\/j.enbuild.2011.03.029","article-title":"Applicability of infrared thermography to the study of the behaviour of stone panels as building envelopes","volume":"43","author":"Cerdeira","year":"2011","journal-title":"Energy Build."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.infrared.2009.01.004","article-title":"Analysis of thermograms for the estimation of dimensions of cracks in building envelope","volume":"52","author":"Dufour","year":"2009","journal-title":"Infrared Phys. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/S0963-8695(00)00039-6","article-title":"Applications of thermography in non-destructive testing of structures","volume":"34","author":"Titman","year":"2001","journal-title":"NDT&E Int."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.enbuild.2018.02.050","article-title":"A discussion concerning active infrared thermography in the evaluation of buildings air infiltration","volume":"168","author":"Lerma","year":"2018","journal-title":"Energy Build."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.enbuild.2013.07.051","article-title":"Energy efficiency is more than skin deep: Improving construction quality control in new-build housing using thermography","volume":"66","author":"Taylor","year":"2013","journal-title":"Energy Build."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1108\/SS-05-2014-0021","article-title":"Infrared thermography \u2013 evaluation of the results reproducibility","volume":"33","author":"Bauer","year":"2015","journal-title":"Struct. Surv."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.conbuildmat.2016.02.026","article-title":"Infrared thermography for assessing moisture related phenomena in building components","volume":"110","author":"Barreira","year":"2016","journal-title":"Constr. Build. Mater."},{"key":"ref_30","first-page":"97","article-title":"Infrared Thermography for Moisture Detection: A Laboratory Study and In-situ Test","volume":"69","author":"Grinzato","year":"2011","journal-title":"Mater. Eval."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.buildenv.2015.07.027","article-title":"Quasi-quantitative infrared thermographic detection of moisture variation in facades with adhered ceramic cladding using principal component analysis","volume":"94","author":"Edis","year":"2015","journal-title":"Build. Environ."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1016\/j.buildenv.2006.06.001","article-title":"Air tightness and air leakages of new lightweight single-family detached houses in Estonia","volume":"42","author":"Kalamees","year":"2007","journal-title":"Build. Environ."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.enbuild.2017.02.009","article-title":"An infrared thermography passive approach to assess the effect of leakage points in buildings","volume":"140","author":"Barreira","year":"2017","journal-title":"Energy Build."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.enbuild.2003.12.012","article-title":"Thermographic survey of two rural buildings in Spain","volume":"36","year":"2004","journal-title":"Energy Build."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jobe.2016.02.012","article-title":"Analysis of building facade defects using infrared thermography: Laboratory studies","volume":"6","author":"Bauer","year":"2016","journal-title":"J. Build. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.enbuild.2018.10.017","article-title":"Improving the detection of thermal bridges in buildings via on-site infrared thermography: The potentialities of innovative mathematical tools","volume":"182","author":"Sfarra","year":"2019","journal-title":"Energy Build."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.conbuildmat.2015.03.032","article-title":"Validation of size estimation of debonds in external wall\u2019s composite finishes via passive Infrared thermography and a gradient algorithm","volume":"87","author":"Lai","year":"2015","journal-title":"Constr. Build. Mater."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.enbuild.2017.06.040","article-title":"Quantitative internal infrared thermography for determining in-situ thermal behaviour of fa\u00e7ades","volume":"151","author":"Tejedor","year":"2017","journal-title":"Energy Build."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.conbuildmat.2005.06.049","article-title":"Evaluation of building materials using infrared thermography","volume":"21","author":"Barreira","year":"2007","journal-title":"Constr. Build. Mater."},{"key":"ref_40","unstructured":"Moyano-Campos, J., Anton-Garc\u00eda, D., Rico-Delgado, F., and Mart\u00edn-Garc\u00eda, D. (2017). Threshold Values for Energy Loss in Building Fa\u00e7ades Using Infrared Thermography Sustainable. Sustain. Dev. Renov. Archit. Urban. Eng., 6."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"17","DOI":"10.5194\/jsss-5-17-2016","article-title":"Atmospheric transmission coefficient modelling in the infrared for thermovision measurements","volume":"5","author":"Minkina","year":"2016","journal-title":"J. Sensors Sens. Syst."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.apenergy.2017.09.047","article-title":"Quantification of heat losses through building envelope thermal bridges influenced by wind velocity using the outdoor infrared thermography technique","volume":"208","author":"Lechowska","year":"2017","journal-title":"Appl. Energy"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Sagan, V., Maimaitijiang, M., Sidike, P., Eblimit, K., Peterson, K.T., Hartling, S., Esposito, F., Khanal, K., Newcomb, M., and Pauli, D. (2019). UAV-based high resolution thermal imaging for vegetation monitoring, and plant phenotyping using ICI 8640 P, FLIR Vue Pro R 640, and thermoMap cameras. Remote Sens., 11.","DOI":"10.3390\/rs11030330"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.compag.2017.05.001","article-title":"An overview of current and potential applications of thermal remote sensing in precision agriculture","volume":"139","author":"Khanal","year":"2017","journal-title":"Comput. Electron. Agric."},{"key":"ref_45","unstructured":"Park, S., Nolan, A., Fuentes, S., Hernandez, E., Chung, H., and O\u00b4Connell, M. (December, January 29). Estimation of crop water stress in a nectarine orchard using high-resolution imagery from unmanned aerial vehicle (UAV) Digital Vineyards View project Apple Sunburn Risk and Fruit Diameter Estimation Using a Smartphone App View project. Proceedings of the 21st International Congress on Modelling and Simulation, Gold Coast, Australia."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1080\/19475705.2016.1225229","article-title":"A methodology for acquisition and processing of thermal data acquired by UAVs: A test about subfluvial springs\u2019 investigations","volume":"8","author":"Aicardi","year":"2017","journal-title":"Geomat. Nat. Hazards Risk"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.rser.2018.05.027","article-title":"Technological review of the instrumentation used in aerial thermographic inspection of photovoltaic plants","volume":"93","year":"2018","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Zefri, Y., ElKettani, A., Sebari, I., and Lamallam, S.A. (2018). Thermal Infrared and Visual Inspection of Photovoltaic Installations by UAV Photogrammetry\u2014Application Case: Morocco. Drones, 2.","DOI":"10.3390\/drones2040041"},{"key":"ref_49","first-page":"30","article-title":"Heat Mapping Drones: An Autonomous Computer-Vision-Based Procedure for Building Envelope Inspection Using Unmanned Aerial Systems (UAS)","volume":"2","author":"Rakha","year":"2018","journal-title":"Technol. Des."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.egypro.2017.09.636","article-title":"Infrared drones in the construction industry: Designing a protocol for building thermography procedures","volume":"132","author":"Entrop","year":"2017","journal-title":"Energy Procedia"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Kayan, H., Eslampanah, R., Yeganli, F., and Askar, M. (2018, January 2\u20135). Heat Leakage Detection and Surveiallance Using Aerial Thermography Drone. Proceedings of the 26th Signal Processing and Communications Applications Conference (SIU), \u00c7e\u015fme, Turkey.","DOI":"10.1109\/SIU.2018.8404366"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Mavromatidis, L., Dauvergne, J., Saleri, R., and Batsale, J. (2014, January 7\u201311). First experiments for the diagnosis and thermophysical sampling using impulse IR thermography from Unmanned Aerial Vehicle (UAV). Proceedings of the 12th International Conference on Quantitative Infrared Thermography (QIRT 2014), Bordeaux, France.","DOI":"10.21611\/qirt.2014.213"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.conbuildmat.2004.05.016","article-title":"Thermal-physical aspects of materials used for the construction of rural buildings in Soria (Spain)","volume":"19","year":"2005","journal-title":"Constr. Build. Mater."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.apenergy.2013.03.066","article-title":"Effects of individual climatic parameters on the infrared thermography of buildings","volume":"110","author":"Lehmann","year":"2013","journal-title":"Appl. Energy"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1080\/09613218408545298","article-title":"Heat Loss from Thermal Bridges","volume":"12","author":"Fang","year":"1984","journal-title":"Batim. Int. Build. Res. Pract."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.enbuild.2015.01.021","article-title":"Time-lapse thermography for building defect detection","volume":"92","author":"Fox","year":"2015","journal-title":"Energy Build."},{"key":"ref_57","unstructured":"Spain Spain CTE-HE (2019, April 01). C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n. Available online: https:\/\/www.codigotecnico.org\/images\/stories\/pdf\/ahorroEnergia\/DBHE.pdf."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Fraga, H., Malheiro, A.C., Moutinho-Pereira, J., Cardoso, R.M., Soares, P.M.M., Cancela, J.J., Pinto, J.G., and Santos, J.A. (2014). Integrated analysis of climate, soil, topography and vegetative growth in iberian viticultural regions. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0108078"},{"key":"ref_59","first-page":"63","article-title":"Spatial climate variability and viticulture in the Mi\u00f1o River Valley of Spain","volume":"46","author":"Jones","year":"2007","journal-title":"Vitis J. Grapevine Res."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.rse.2016.09.007","article-title":"Thermal infrared remote sensing of urban heat: Hotspots, vegetation, and an assessment of techniques for use in urban planning","volume":"186","author":"Coutts","year":"2016","journal-title":"Remote Sens. Environ."},{"key":"ref_61","unstructured":"(2007). CIBSE Guide Volume C\u2014Reference Data, Chartered Institution of Building Service Engineers."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Harvey, L.D. (2012). A handbook on Low-Energy Buildings and District-Energy Systems: Fundamentals, Techniques and Examples, Routledge.","DOI":"10.4324\/9781849770293"},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Brooke, C. (2018). Thermal imaging for the archaeological investigation of historic buildings. Remote Sens., 10.","DOI":"10.3390\/rs10091401"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.culher.2013.03.006","article-title":"A qualitative method for combining thermal imprints to emerging weak points of ancient wall structures by passive infrared thermography\u2014A case study","volume":"15","author":"Bisegna","year":"2014","journal-title":"J. Cult. Herit."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.conbuildmat.2012.06.062","article-title":"Infrared thermographic inspection of murals and characterization of degradation in historic monuments","volume":"48","author":"Kordatos","year":"2013","journal-title":"Constr. Build. Mater."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"e009","DOI":"10.3989\/mc.2013.06612","article-title":"Pathology of Building Materials in Historic Buildings. Relationship between Laboratory Testing and Infrared Thermography","volume":"64","author":"Lerma","year":"2013","journal-title":"Mater. Constr."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1109\/JSEN.2013.2287003","article-title":"Influence of field of view of thermal imagers and angle of view on temperature measurements by infrared thermovision","volume":"14","author":"Muniz","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"074101","DOI":"10.1117\/1.OE.53.7.074101","article-title":"Handy method to estimate uncertainty of temperature measurement by infrared thermography","volume":"53","author":"Muniz","year":"2014","journal-title":"Opt. Eng."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.infrared.2017.09.022","article-title":"Analysis of the configuration and the location of thermographic equipment for the inspection in photovoltaic systems","volume":"87","author":"Carpio","year":"2017","journal-title":"Infrared Phys. Technol."},{"key":"ref_70","first-page":"22","article-title":"IR radiometer sensitivity and accuracy improvement by eliminating spurious radiation for emissivity measurements on highly specular samples in the 2\u201325 \u03bcm spectral range","volume":"110","author":"Tello","year":"2017","journal-title":"Meas. J. Int. Meas. Confed."}],"container-title":["Remote Sensing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-4292\/11\/12\/1424\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:58:40Z","timestamp":1760187520000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-4292\/11\/12\/1424"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,14]]},"references-count":70,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["rs11121424"],"URL":"https:\/\/doi.org\/10.3390\/rs11121424","relation":{},"ISSN":["2072-4292"],"issn-type":[{"value":"2072-4292","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,14]]}}}