{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T10:19:31Z","timestamp":1762251571393,"version":"build-2065373602"},"reference-count":57,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2010,1,7]],"date-time":"2010-01-07T00:00:00Z","timestamp":1262822400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The particular analytical performance of ultramicroelectrode arrays (UMEAs) has attracted a high interest by the research community and has led to the development of a variety of electroanalytical applications. UMEA-based approaches have demonstrated to be powerful, simple, rapid and cost-effective analytical tools for environmental analysis compared to available conventional electrodes and standardised analytical techniques. An overview of the fabrication processes of UMEAs, their characterization and applications carried out by the Spanish scientific community is presented. A brief explanation of theoretical aspects that highlight their electrochemical behavior is also given. Finally, the applications of this transducer platform in the environmental field are discussed.<\/jats:p>","DOI":"10.3390\/s100100475","type":"journal-article","created":{"date-parts":[[2010,1,13]],"date-time":"2010-01-13T04:04:25Z","timestamp":1263355465000},"page":"475-490","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["Ultramicroelectrode Array Based Sensors: A Promising Analytical Tool for Environmental Monitoring"],"prefix":"10.3390","volume":"10","author":[{"given":"Jahir","family":"Orozco","sequence":"first","affiliation":[{"name":"Instituto de Microelectr\u00f3nica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain"}]},{"given":"C\u00e9sar","family":"Fern\u00e1ndez-S\u00e1nchez","sequence":"additional","affiliation":[{"name":"Instituto de Microelectr\u00f3nica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain"}]},{"given":"Cecilia","family":"Jim\u00e9nez-Jorquera","sequence":"additional","affiliation":[{"name":"Instituto de Microelectr\u00f3nica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2010,1,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.1002\/anie.199312681","article-title":"Ultramicroelectrodes in electrochemistry","volume":"32","author":"Heinze","year":"1993","journal-title":"Angew. Chem. Int. Edit"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1125A","DOI":"10.1021\/ac00232a004","article-title":"Microvoltammetric electrodes","volume":"53","author":"Mark","year":"1981","journal-title":"Anal. Chem"},{"key":"ref_3","unstructured":"Bard, A.J., and Faulkner, L.R. (2001). Electrochemical Methods. Fundamentals and Applications, John Wiley. [2nd ed]."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1021\/ed071p602","article-title":"Cyclic voltametry wtih ultramicroelectrodes","volume":"71","author":"Ching","year":"1994","journal-title":"J. Chem. Educ"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1351\/pac200072081483","article-title":"Microelectrodes, definitions, characterization, and applications","volume":"72","author":"Stulik","year":"2000","journal-title":"Pure Appl.Chem"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1002\/(SICI)1521-4109(199807)10:8<526::AID-ELAN526>3.0.CO;2-7","article-title":"Evaluation of microelectrode arrays for amperometric detection by scanning electrochemical microscopy","volume":"10","author":"Wittstock","year":"1998","journal-title":"Electroanalysis"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1016\/S0925-4005(97)00159-7","article-title":"Performance of amperometric sensors based on multiple microelectrode arrays","volume":"44","author":"Morf","year":"1997","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1002\/1521-4109(200005)12:9<677::AID-ELAN677>3.0.CO;2-4","article-title":"Microfabricated ultramicroelectrode arrays: Developments, advances, and applications in environmental analysis","volume":"12","author":"Feeney","year":"2000","journal-title":"Electroanalysis"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2437","DOI":"10.1016\/S0013-4686(00)00331-5","article-title":"Microelectrode sensors for biomedical and environmental applications","volume":"45","year":"2000","journal-title":"Electrochim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1039\/B513786A","article-title":"Regular arrays of microdisc electrodes: simulation quantifies the fraction of \u2018dead\u2019 electrodes","volume":"131","author":"Ordeig","year":"2006","journal-title":"Analyst"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.snb.2003.08.012","article-title":"Development of an ultramicroelectrode arrays (UMEAs) sensor for trace heavy metal measurement in water","volume":"97","author":"Xie","year":"2004","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/0003-2670(96)00116-X","article-title":"Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability","volume":"329","author":"Belmont","year":"1996","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1016\/j.talanta.2006.05.090","article-title":"Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions","volume":"71","author":"Berduque","year":"2007","journal-title":"Talanta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2222","DOI":"10.1021\/ac991185z","article-title":"On-site analysis of arsenic in groundwater using a microfabricated gold ultramicroelectrode array","volume":"72","author":"Feeney","year":"2000","journal-title":"Anal. Chem"},{"key":"ref_15","first-page":"7","article-title":"Stripping analysis into the 21st century: faster, smaller, cheaper, simpler and better","volume":"385","author":"Joseph","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1021\/ac00075a017","article-title":"Iridium-based ultramicroelectrde arrya fabricated by microlithography","volume":"66","author":"Kounaves","year":"1994","journal-title":"Anal. Chem"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0925-4005(01)00577-9","article-title":"Simultaneous determination of Cd, Pb and Cu metal trace concentrations in water certified samples and soil extracts by means of Hg-electroplated-Ir microelectrode array based sensors","volume":"76","author":"Silva","year":"2001","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_18","unstructured":"Alegret, S. (2003). Comprehensive Analytical Chemistry, Elsevier Science B.V."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.snb.2005.09.003","article-title":"Fabrication of microelectrode arrays for in situ sensing of oxidation reduction potentials","volume":"115","author":"Lee","year":"2006","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.aca.2006.07.030","article-title":"Monitoring of bentonite pore water with a probe based on solid-state microsensors","volume":"579","author":"Orozco","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.snb.2008.09.009","article-title":"Suitability of gold-array ultramicroelectrodes for electrochemical detection in flow systems","volume":"135","author":"Arino","year":"2008","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_22","first-page":"267","article-title":"Voltammetry at ultramicroelectrodes","volume":"15","author":"Wightman","year":"1989","journal-title":"Electroanal. Chem"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.elecom.2006.11.023","article-title":"Conical recessed gold microelectrode arrays produced during photolithographic methods: Characterisation and causes","volume":"9","author":"Aguiar","year":"2007","journal-title":"Electrochem. Commun"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1021\/ac034890n","article-title":"Addressable microelectrode arrays: Characterization by imaging with scanning electrochemical microscopy","volume":"76","author":"Zoski","year":"2004","journal-title":"Anal. Chem"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1039\/b802475h","article-title":"Towards multifunctional microelectrode arrays","volume":"133","author":"Aguiar","year":"2008","journal-title":"Analyst"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1039\/b415395m","article-title":"Nanoelectrodes, nanoelectrode arrays and their applications","volume":"129","author":"Arrigan","year":"2004","journal-title":"Analyst"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.jelechem.2006.05.008","article-title":"The linear sweep voltammetry of random arrays of microdisc electrodes: Fitting of experimental data","volume":"592","author":"Ordeig","year":"2006","journal-title":"J. Electroan. Chem"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1021\/ac00075a017","article-title":"Iridium based ultramicroelectrode array fabricated by mircrolithography","volume":"66","author":"Kounaves","year":"1994","journal-title":"Anal. Chem"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"A407","DOI":"10.1021\/ac961977i","article-title":"Silicon micromachining - Sensors to systems","volume":"68","author":"Kovacs","year":"1996","journal-title":"Anal. Chem"},{"key":"ref_30","unstructured":"Madou, M.J., and Morrison, S.R. (1989). Chemical Sensing with Solid State Devices, Elsevier Science."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1002\/(SICI)1521-4109(199802)10:2<89::AID-ELAN89>3.0.CO;2-J","article-title":"Analytical characterization of microlithographically fabricated iridium-based ultramicroelectrode arrays","volume":"10","author":"Feeney","year":"1998","journal-title":"Electroanalysis"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.jelechem.2005.07.021","article-title":"The cyclic and linear sweep voltammetry of regular arrays of microdisc electrodes: Fitting of experimental data","volume":"585","author":"Davies","year":"2005","journal-title":"J. Electroanal. Chem"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.bioelechem.2009.03.013","article-title":"Gold nanoparticle-modified ultramicroelectrode arrays for biosensing: A comparative assessment","volume":"75","author":"Orozco","year":"2009","journal-title":"Bioelectrochemistry"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4877","DOI":"10.1021\/es8005964","article-title":"Underpotential deposition-anodic stripping voltammetric detection of copper at gold nanoparticle-modified ultramicroelectrode arrays","volume":"42","author":"Orozco","year":"2008","journal-title":"Envi. Sci. Tech"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/j.electacta.2007.07.049","article-title":"Characterization of ultramicroelectrode arrays combining electrochemical techniques and optical microscopy imaging","volume":"53","author":"Orozco","year":"2007","journal-title":"Electrochim. Acta"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1002\/elan.200503395","article-title":"Sulfite determination at in situ plated copper modified gold ultramicroelectrode arrays","volume":"18","author":"Ordeig","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1002\/elan.200503437","article-title":"Trace detection of mercury(II) using gold ultra-microelectrode arrays","volume":"18","author":"Ordeig","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1002\/elan.200603570","article-title":"Electroanalysis of Bromate, iodate and chlorate at tungsten oxide modified platinum microelectrode arrays","volume":"18","author":"Ordeig","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.snb.2007.03.038","article-title":"Continuous measurement of acute toxicity in water using a solid state microrespirometer","volume":"126","author":"Ordeig","year":"2007","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.snb.2008.06.056","article-title":"Measuring acute toxicity using a solid-state microrespirometer Part II. A theoretical framework for the elucidation of metabolic parameters","volume":"135","author":"Godino","year":"2008","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"679","DOI":"10.2116\/analsci.22.679","article-title":"Gold ultra-microelectrode arrays: Application to the steady-state voltammetry of hydroxide ion in aqueous solution","volume":"22","author":"Ordeig","year":"2006","journal-title":"Anal. Sci"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1002\/elan.1140050915","article-title":"Gold Ultramicroelectrodes for On-Site Monitoring of Trace Lead","volume":"5","author":"Wang","year":"1993","journal-title":"Electroanalysis"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/0925-4005(95)85183-6","article-title":"Photocurable Polymers Applied As Encapsulating Materials for ISFET Production","volume":"25","author":"Bratov","year":"1995","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jelechem.2006.10.021","article-title":"Electrochemical sizing of hemispherical microdroplets immobilized as regular arrays on partially blocked electrodes","volume":"602","author":"Barnes","year":"2007","journal-title":"J. Electroanal. Chem"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jelechem.2006.06.015","article-title":"Experimental cyclic voltammetry at partially blocked electrodes: Elevated cylindrical blocks\u2014Significantly blocked and non-flat electrodes can appear to show one-dimensional diffusion","volume":"596","author":"Chevallier","year":"2006","journal-title":"J. Electroanal. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"9992","DOI":"10.1021\/jp0721301","article-title":"Electrochemical investigation of hemispherical microdroplets of N,N-didodecyl-N\u2032,N\u2032-diethylphenylenediamine immobilized as regular arrays on partially-blocked electrodes: A new approach to liquid vertical bar liquid voltammetry","volume":"111","author":"Rayner","year":"2007","journal-title":"J. Phys. Chem. C"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"2585","DOI":"10.1002\/cphc.200600394","article-title":"A new method for the study of processes at the liquid-liquid interface using an array of microdroplets on a Au electrode","volume":"7","author":"Simm","year":"2006","journal-title":"ChemPhysChem"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1039\/B607888E","article-title":"Diffusional protection of electrode surfaces using regular arrays of immobilised droplets: overcoming interferences in electroanalysis","volume":"131","author":"Simm","year":"2006","journal-title":"Analyst"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"3622","DOI":"10.1021\/ac702570p","article-title":"On-chip electric field driven electrochemical detection using a poly(dimethylsiloxane) microchannel with gold microband electrodes","volume":"80","author":"Ordeig","year":"2008","journal-title":"Anal. Chem"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"12058","DOI":"10.1021\/jp073224d","article-title":"Voltammetry at regular microband electrode arrays: Theory and experiment","volume":"111","author":"Streeter","year":"2007","journal-title":"J. Phys. Chem. C"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1002\/(SICI)1521-4109(199811)10:16<1112::AID-ELAN1112>3.0.CO;2-Z","article-title":"Fabrication and sensing applications of microelectrodes on silicon substrates","volume":"10","author":"Andrews","year":"1998","journal-title":"Electroanalysis"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"3899","DOI":"10.1016\/S0013-4686(99)00097-3","article-title":"Modifications and characterization of a silicon-based microelectrode array","volume":"44","author":"Buss","year":"1999","journal-title":"Electrochim. Acta"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1878","DOI":"10.1149\/1.1393451","article-title":"Influence of geometry on the electrochemical response of carbon interdigitated microelectrodes","volume":"147","author":"Kostecki","year":"2000","journal-title":"J. Electrochem. Soc"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/S0925-4005(01)00637-2","article-title":"Quality control of ultra-microelectrode arrays using cyclic voltammetry, electrochemical impedance spectroscopy and scanning electrochemical microscopy","volume":"76","author":"Koster","year":"2001","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.bioelechem.2009.03.013","article-title":"Gold nanoparticle-modified ultramicroelectrode arrays for biosensing: A comparative assessment","volume":"75","author":"Orozco","year":"2009","journal-title":"Bioelectrochemistry"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1002\/elan.200603727","article-title":"Chronoamperometric and voltammetric characterization of gold ultramicroelectrode arrays","volume":"19","author":"Arino","year":"2007","journal-title":"Electroanalysis"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jelechem.2005.07.022","article-title":"The cyclic and linear sweep voltammetry of regular and random arrays of microdisc electrodes: Theory","volume":"585","author":"Davies","year":"2005","journal-title":"J. Electroanal. Chem"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/475\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:07Z","timestamp":1760220067000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/475"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,7]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2010,1]]}},"alternative-id":["s100100475"],"URL":"https:\/\/doi.org\/10.3390\/s100100475","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2010,1,7]]}}}