{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:37:45Z","timestamp":1760243865097,"version":"build-2065373602"},"reference-count":29,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2010,1,18]],"date-time":"2010-01-18T00:00:00Z","timestamp":1263772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The real-time detection of trace concentrations of biological toxins requires significant improvement of the detection methods from those reported in the literature. To develop a highly sensitive and selective detection device it is necessary to determine the optimal measuring conditions for the electrochemical sensor in three domains: time, frequency and polarization potential. In this work we utilized a time-resolved electrochemical impedance spectroscopy for the detection of trace concentrations of Staphylococcus enterotoxin B (SEB). An anti-SEB antibody has been attached to the nano-porous aluminum surface using 3-aminopropyltriethoxysilane\/glutaraldehyde coupling system. This immobilization method allows fabrication of a highly reproducible and stable sensing device. Using developed immobilization procedure and optimized detection regime, it is possible to determine the presence of SEB at the levels as low as 10 pg\/mL in 15 minutes.<\/jats:p>","DOI":"10.3390\/s100100655","type":"journal-article","created":{"date-parts":[[2010,1,19]],"date-time":"2010-01-19T09:50:33Z","timestamp":1263894633000},"page":"655-669","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Label-Free Toxin Detection by Means of Time-Resolved Electrochemical Impedance Spectroscopy"],"prefix":"10.3390","volume":"10","author":[{"given":"Changhoon","family":"Chai","sequence":"first","affiliation":[{"name":"School of Environmental and Biological Sciences, Rutgers, the State University of New Jersey, New Brunswick, NJ 08901, USA"}]},{"given":"Paul","family":"Takhistov","sequence":"additional","affiliation":[{"name":"School of Environmental and Biological Sciences, Rutgers, the State University of New Jersey, New Brunswick, NJ 08901, USA"}]}],"member":"1968","published-online":{"date-parts":[[2010,1,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S0956-5663(03)00179-9","article-title":"Electrical frequency dependent characterization of DNA hybridization","volume":"19","author":"Gheorghe","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1567-5394(01)00166-9","article-title":"Reagentless biosensing using electrochemical impedance spectroscopy","volume":"55","author":"Farace","year":"2002","journal-title":"Bioelectrochem"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S0956-5663(02)00114-8","article-title":"Layer-by-layer assembly of multilayer films composed of avidin and biotin-labeled antibody for immunosensing","volume":"18","author":"Cui","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/0956-5663(95)96958-2","article-title":"Impedance based sensing of the specific binding reaction between Staphylococcus enterotoxin B and its antibody on an ultra-thin platinum film","volume":"10","author":"DeSilva","year":"1995","journal-title":"Biosens. Bioelectron"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/S1388-2481(99)00071-5","article-title":"An electrochemical impedance immunoanalytical method for detecting immunological interaction of human mammary tumor associated glycoprotein and its monoclonal antibody","volume":"1","author":"Jie","year":"1999","journal-title":"Electrochem. Commun"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/S0956-5663(99)00036-6","article-title":"The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form","volume":"14","author":"Naumann","year":"1999","journal-title":"Biosen. Bioelectron"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S1567-5394(02)00029-4","article-title":"Impedimetric immunosensor using avidin-biotin for antibody immobilization","volume":"56","author":"Ouerghi","year":"2002","journal-title":"Bioelectrochem"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/S0956-5663(02)00223-3","article-title":"Electrochemical transducers based on surfactant bilayers for the direct detection of affinity interactions","volume":"18","author":"Vagin","year":"2003","journal-title":"Biosen. Bioelectron"},{"key":"ref_9","unstructured":"Rubinstein, I. (1995). Physical Electrochemistry: Principles, Methods, and Applications, CRC."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1088\/0022-3727\/32\/14\/201","article-title":"Dielectric relaxation in solids","volume":"R","author":"Jonscher","year":"1999","journal-title":"J. Phys. D: Appl. Phys"},{"key":"ref_11","unstructured":"McDonald, J.R. (1987). Impedance Spectroscopy: Emphasizing Solid Materials and Systems, Wiley-Interscience."},{"key":"ref_12","unstructured":"MacDonald, J.R. (1987). Impedance Spectroscopy: Emphasizing Solid Materials and Systems, Wiley-Interscience."},{"key":"ref_13","unstructured":"Jonscher, A.K. (1983). Dielectric Relaxation in Solids, Chelsea Dielectrics Press."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/S0956-5663(02)00223-3","article-title":"Electrochemical transducers based on surfactant bilayers for the direct detection of affinity interactions","volume":"18","author":"Vagin","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1002\/elan.200390114","article-title":"Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors","volume":"15","author":"Katz","year":"2003","journal-title":"Electroanalysis"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/0168-1605(88)90057-8","article-title":"Estimation of human dose of staphylococcal enterotoxin A from a large outbreak of staphylococcal food poisoning involving chocolate milk","volume":"7","author":"Evenson","year":"1988","journal-title":"Int. J. Food Microbiol"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/j.1745-4581.2005.00005.x","article-title":"A biosensor method for a competitive immunoassay detection of staphylococcal enterotoxin b (seb) in milk","volume":"13","author":"Medina","year":"2005","journal-title":"J. Rapid Method. Autom. Microbio"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/S0956-5663(02)00014-3","article-title":"Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor","volume":"17","author":"Naimushin","year":"2002","journal-title":"Biosens. Bioelectron"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1063\/1.166380","article-title":"Pattern Selection During Electropolishing due to Double-Layer Effects","volume":"1","author":"Yuzhakov","year":"1999","journal-title":"Chaos"},{"key":"ref_20","unstructured":"Mittal, K.L. (1992). Silanes and Other Coupling Agents, VSP."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1002\/(SICI)1097-0290(19981020)60:2<137::AID-BIT1>3.0.CO;2-O","article-title":"Detection of functional groups and antibodies on microfabricated surfaces by confocal microscopy","volume":"60","author":"Nashat","year":"1998","journal-title":"Biotechnol. Bioeng"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S0956-5663(99)00039-1","article-title":"Biosensors for detection of pathogenic bacteria","volume":"14","author":"Ivnitski","year":"1999","journal-title":"Biosens. Bioelectron"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0022-0728(98)00133-8","article-title":"A note on the surface stress and tension of solid metal electrodes","volume":"453","author":"Schmickler","year":"1998","journal-title":"J. Electroanal. Chem"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1002\/1521-4109(200008)12:12<940::AID-ELAN940>3.0.CO;2-V","article-title":"Amperometric Immunosensor for Direct Detection of Human IgG","volume":"12","author":"Snejdarkova","year":"2000","journal-title":"Electroanal"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.bioelechem.2004.05.004","article-title":"A novel immunosensor based on immobilization of hepatitis B surface antibody on platinum electrode modified colloidal gold and polyvinyl butyral as matrices via electrochemical impedance spectroscopy","volume":"65","author":"Tang","year":"2004","journal-title":"Bioelectrochemistry"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/S0167-9317(03)00042-X","article-title":"Fabrication and characterization of anodic aluminum oxide template","volume":"66","author":"Wang","year":"2003","journal-title":"Microelectr. Eng"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/S0925-4005(97)80029-9","article-title":"Antigen-antibody diffusion-limited binding kinetics for biosensors: a fractal analysis","volume":"32","author":"Sadana","year":"1996","journal-title":"Sens. Actuat. B: Chem."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Bockris, J., and Reddy, A. (1998). Modern Electrochemistry, Plenum.","DOI":"10.1007\/b114546"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.ab.2005.01.030","article-title":"Antibody microarrays for native toxin detection","volume":"339","author":"Rucker","year":"2005","journal-title":"Anal. Biochem"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/655\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:12Z","timestamp":1760220072000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/655"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,18]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2010,1]]}},"alternative-id":["s100100655"],"URL":"https:\/\/doi.org\/10.3390\/s100100655","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2010,1,18]]}}}