{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T01:17:53Z","timestamp":1791595073339,"version":"4.3.4"},"reference-count":19,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2010,1,26]],"date-time":"2010-01-26T00:00:00Z","timestamp":1264464000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Critical care units are equipped with commercial monitoring devices capable of sensing patients\u2019 physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units\u2019 healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale\u2019s pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient\u2019s bed, and guarantees that the urine flows properly through the urine meter input tube. The scale\u2019s readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.<\/jats:p>","DOI":"10.3390\/s100100934","type":"journal-article","created":{"date-parts":[[2010,1,26]],"date-time":"2010-01-26T09:15:31Z","timestamp":1264497331000},"page":"934-951","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["A Device for Automatically Measuring and Supervising the Critical Care Patient\u2019S Urine Output"],"prefix":"10.3390","volume":"10","author":[{"given":"Abraham","family":"Otero","sequence":"first","affiliation":[{"name":"Department of Information and Communications Systems Engineering, University San Pablo CEU, Boadilla del Monte 28668 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Palacios","sequence":"additional","affiliation":[{"name":"Critical Care Unit, University Hospital of Getafe, Getafe, Carretera Toledo KM 12.500, 28901 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teodor","family":"Akinfiev","sequence":"additional","affiliation":[{"name":"Automatic Control Department, IAI\/CSIC-Industrial Automation Institute, Spanish Council for Scientific Research, La Poveda, Arganda del Rey, 28500 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roemi","family":"Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Automatic Control Department, IAI\/CSIC-Industrial Automation Institute, Spanish Council for Scientific Research, La Poveda, Arganda del Rey, 28500 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2010,1,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.artmed.2009.08.002","article-title":"Addressing the flaws of current critical alarms: a fuzzy constraint satisfaction approach","volume":"47","author":"Otero","year":"2009","journal-title":"Artif. Intell. Med"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/51.248164","article-title":"Intelligent patient monitoring and management systems: a review","volume":"12","author":"Mora","year":"1993","journal-title":"IEEE Eng. Med. Biol. Mag"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.3390\/s6091102","article-title":"Self-powered wireless sensor networks for remote patient monitoring in hospitals","volume":"6","author":"Hande","year":"2006","journal-title":"Sensors"},{"key":"ref_4","unstructured":"Jungk, A., Thull, B., and Rau, G. (2002). Fuzzy Logic in Medicine, Physica-Verlag."},{"key":"ref_5","unstructured":"Brunzel, N.A. (1994). Fundamentals of Urine and Body Fluid Analysis, W.B. Saunders Company."},{"key":"ref_6","unstructured":"Williams, G., and Pickup, J.C. (2004). Handbook of Diabetes, Blackwell Science Ltd."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1056\/NEJMoa010307","article-title":"Group, E.G.D.T.C. Early goal-directed therapy in the treatment of severe sepsis and septic shock","volume":"345","author":"Rivers","year":"2001","journal-title":"N. Engl. J. Med"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/j.1445-2197.2006.03641.x","article-title":"Fluid resuscitation in major burns","volume":"76","author":"Mitra","year":"2006","journal-title":"ANZ J. Surg"},{"key":"ref_9","unstructured":"Akinfiev, T., Fern\u00e1ndez, R., Otero, A., and Palacios, F. (2009). Device for measuring the amount of liquid that flows and procedure for its measurement, ES P200930074,."},{"key":"ref_10","unstructured":"Johnson, S.J. (1978). Liquid Level Measurement Device, US Patent 3693445,."},{"key":"ref_11","unstructured":"Ishida, S. (1990). Liquid level indicator using laser beam, US patent 4938590,."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"629.e13","DOI":"10.1016\/j.jcrc.2008.12.008","article-title":"Accuracy and ease of use of a novel electronic urine output monitoring device compared with standard manual urinometer in the intensive care unit","volume":"24","author":"Hersch","year":"2009","journal-title":"Am. J. Crit. Care"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Otero, A., Panigrahi, B., Palacios, F., Akinfiev, T., and Fern\u00e1ndez, R. (2009). A prototype device to measure and supervise urine output of critical patients. Recent Adv. Biomed. Eng., 169\u2013173.","DOI":"10.5772\/7474"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/S0933-3657(00)00085-3","article-title":"Fuzzy logic in a patient supervision systems","volume":"21","author":"Barro","year":"2001","journal-title":"Artif. Intell. Med"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/0020-0255(75)90036-5","article-title":"The concept of a linguistic variable and its application to approximate reasoning","volume":"8","author":"Zadeh","year":"1975","journal-title":"Inf. Sci"},{"key":"ref_16","unstructured":"Kaufmann, A., and Gupta, M. (1984). Introduction to Fuzzy Arithmetic, Van Nostrand Reinhold Company Inc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1007\/978-3-540-85861-4_2","article-title":"Visual knowledge-based metaphors to support the analysis of polysomnographic recordings","volume":"49","author":"Otero","year":"2008","journal-title":"Adv. Soft Comput"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.ccc.2005.01.002","article-title":"Sepsis and the kidney","volume":"21","author":"Klenzak","year":"2005","journal-title":"Crit. care clin"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1056\/NEJMra032401","article-title":"Acute Renal Failure and Sepsis","volume":"351","author":"Schrier","year":"2004","journal-title":"N. Engl. J. Med"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/934\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:19Z","timestamp":1760220079000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/1\/934"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,26]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2010,1]]}},"alternative-id":["s100100934"],"URL":"https:\/\/doi.org\/10.3390\/s100100934","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1,26]]}}}