{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T21:36:33Z","timestamp":1787607393873,"version":"build-2736575974"},"reference-count":18,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2010,3,4]],"date-time":"2010-03-04T00:00:00Z","timestamp":1267660800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Presented is a single-ended potentiostat topology with a new interface connection between sensor electrodes and potentiostat circuit to avoid deviation of cell voltage and linearly convert the cell current into voltage signal. Additionally, due to the increased harmonic distortion quantity when detecting low-level sensor current, the performance of potentiostat linearity which causes the detectable current and dynamic range to be limited is relatively decreased. Thus, to alleviate these irregularities, a fully-differential potentiostat is designed with a wide output voltage swing compared to single-ended potentiostat. Two proposed potentiostats were implemented using TSMC 0.18-\u03bcm CMOS process for biomedical application. Measurement results show that the fully differential potentiostat performs relatively better in terms of linearity when measuring current from 500 \u00bapA to 10 uA. Besides, the dynamic range value can reach a value of 86 dB.<\/jats:p>","DOI":"10.3390\/s100301782","type":"journal-article","created":{"date-parts":[[2010,3,4]],"date-time":"2010-03-04T11:10:26Z","timestamp":1267701026000},"page":"1782-1797","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":45,"title":["Wide Dynamic Range CMOS Potentiostat for Amperometric Chemical Sensor"],"prefix":"10.3390","volume":"10","author":[{"given":"Wei-Song","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Ting","family":"Kuo","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-Yi","family":"Huang","sequence":"additional","affiliation":[{"name":"Graduate Institute of Electrical Engineering, National Taipei University, No. 151, University Road, San Shia, Taipei 237, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ching-Hsing","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2010,3,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1921","DOI":"10.1063\/1.1463715","article-title":"A comparison between potentiostatic circuits with grounded work or auxiliary electrode","volume":"73","author":"Busoni","year":"2002","journal-title":"Rev. Scient. Instrum"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1109\/19.137366","article-title":"A potentiostat based on a voltage-controlled current source for use with amperometric gas sensors","volume":"41","author":"Fidler","year":"1992","journal-title":"IEEE Trans. Instrum. Measure"},{"key":"ref_3","unstructured":"Chung, W.Y., Paglinawan, A.C., Wang, Y.-H., and Kuo, T.T. (2007, January December). A 600 \u03bcm read-out circuit with potentiostat for amperometric chemical sensors and glucose meter applications. Tainan, Taiwan."},{"key":"ref_4","unstructured":"Jichun, Z., Trombly, N., and Mason, A. (2004, January October). A low noise readout circuit for integrated electrochemical biosensor arrays. Vienna, Austria."},{"key":"ref_5","unstructured":"Reay, R.J., Kounaves, S.P., and Kovacs, G.T.A. (1994, January February). An integrated CMOS potentiostat for miniaturized electroanalytical instrumentation. San Francisco, CA, USA."},{"key":"ref_6","unstructured":"Iniewski, K. (2008). VLSI Circuits for Biomedical Applications, Artech House. [1st ed]."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2371","DOI":"10.1109\/TCSI.2006.884425","article-title":"16-channel integrated potentiostat for distributed neurochemical sensing","volume":"53","author":"Genov","year":"2006","journal-title":"IEEE Trans. Circ. Syst. I: Regular Papers"},{"key":"ref_8","first-page":"736","article-title":"Design of a CMOS potentiostat circuit for electrochemical detector arrays","volume":"54","author":"Ayers","year":"2007","journal-title":"IEEE Trans. Circ. Syst. I: Regular Papers"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1109\/JSEN.2007.893236","article-title":"Stability analysis and novel compensation of a CMOS current-feedback potentiostat circuit for electrochemical sensors","volume":"7","author":"Hasan","year":"2007","journal-title":"IEEE Sens. J"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1109\/JSEN.2006.870142","article-title":"A time-based VLSI potentiostat for ion current measurements","volume":"6","author":"Narula","year":"2006","journal-title":"IEEE Sens. J"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/JSSC.1987.1052753","article-title":"A CMOS potentiostat for amperometric chemical sensors","volume":"22","author":"Turner","year":"1987","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_12","unstructured":"Narula, H.S., and Harris, J.G. (2004, January February). Integrated VLSI potentiostat for cyclic voltammetry in electrolytic reactions. Lafayette, LA, USA."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1109\/TBCAS.2007.893176","article-title":"VLSI potentiostat array with oversampling gain modulation for wide-range neurotransmitter sensing","volume":"1","author":"Stanacevic","year":"2007","journal-title":"IEEE Trans. Biomed. Circ. Syst"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ahmadi, M.M., and Jullien, G.A. (2004, January July). A very low power CMOS potentiostat for bioimplantable applications. Banff, Alberta, Canada.","DOI":"10.1109\/IWSOC.2005.32"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1109\/JSSC.2003.813217","article-title":"A 0.5-V 1-uW successive approximation ADC","volume":"38","author":"Sauerbrey","year":"2003","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_16","unstructured":"Kakerow, R.G., Kappert, H., Spiegel, E., and Manoli, Y. (1995, January June). Low-power single-chip CMOS potentiostat. Stockholm, Sweden."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1109\/JSEN.2008.2011085","article-title":"A fully differential potentiostat","volume":"9","author":"Martin","year":"2009","journal-title":"IEEE Sens. J"},{"key":"ref_18","first-page":"1339","article-title":"Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors","volume":"56","author":"Ahmadi","year":"2009","journal-title":"IEEE Trans. Circ. Syst. I: Regular Papers"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/3\/1782\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:38Z","timestamp":1760220098000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/3\/1782"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3,4]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2010,3]]}},"alternative-id":["s100301782"],"URL":"https:\/\/doi.org\/10.3390\/s100301782","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3,4]]}}}