{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T01:01:12Z","timestamp":1776128472873,"version":"3.50.1"},"reference-count":86,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2010,8,20]],"date-time":"2010-08-20T00:00:00Z","timestamp":1282262400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Characteristics of physical activity are indicative of one\u2019s mobility level, latent chronic diseases and aging process. Accelerometers have been widely accepted as useful and practical sensors for wearable devices to measure and assess physical activity. This paper reviews the development of wearable accelerometry-based motion detectors. The principle of accelerometry measurement, sensor properties and sensor placements are first introduced. Various research using accelerometry-based wearable motion detectors for physical activity monitoring and assessment, including posture and movement classification, estimation of energy expenditure, fall detection and balance control evaluation, are also reviewed. Finally this paper reviews and compares existing commercial products to provide a comprehensive outlook of current development status and possible emerging technologies.<\/jats:p>","DOI":"10.3390\/s100807772","type":"journal-article","created":{"date-parts":[[2011,1,14]],"date-time":"2011-01-14T15:36:17Z","timestamp":1295019377000},"page":"7772-7788","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":831,"title":["A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring"],"prefix":"10.3390","volume":"10","author":[{"given":"Che-Chang","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Yuan Ze University \/ 135, Yuan-Tung Rd., Chung-Li, 32003, Taiwan"}]},{"given":"Yeh-Liang","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Yuan Ze University \/ 135, Yuan-Tung Rd., Chung-Li, 32003, Taiwan"}]}],"member":"1968","published-online":{"date-parts":[[2010,8,20]]},"reference":[{"key":"ref_1","first-page":"126","article-title":"Physical activity, exercise and physical fitness: Definitions and distinctions for health-related research","volume":"110","author":"Caspersen","year":"1985","journal-title":"Public. Health. Rep"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1378\/chest.117.5.1359","article-title":"Quantitating physical activity in COPD using a triaxial accelerometer","volume":"117","author":"Steele","year":"2000","journal-title":"Chest"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1109\/10.133202","article-title":"Methods to assess physical activity with special reference to motion sensors and accelerometers","volume":"38","author":"Meijer","year":"1991","journal-title":"IEEE. Trans. Biomed. Eng"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","article-title":"The timed \u201cUp & Go\u201d: A test of basic functional mobility for frail elderly persons","volume":"39","author":"Podsiadlo","year":"1991","journal-title":"J. Am. Geriatr. Soc"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3138\/ptc.41.6.304","article-title":"Measuring balance in elderly: Preliminary development of an instrument","volume":"41","author":"Berg","year":"1989","journal-title":"Physiother. Can"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/BF00421777","article-title":"The use of pedometer and actometer in studying daily physical activity in man. Part I: Reliability of pedometer and actometer","volume":"37","author":"Saris","year":"1977","journal-title":"Eur. J. Appl. Physiol"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1249\/01.mss.0000185571.49104.82","article-title":"The technology of accelerometry-based activity monitors: Current and future","volume":"37","author":"Chen","year":"2005","journal-title":"Med. Sci. Sports. Exerc"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0967-3334\/25\/2\/R01","article-title":"Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement","volume":"25","author":"Mathie","year":"2004","journal-title":"Physiol. Meas"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"543","DOI":"10.2106\/00004623-195335030-00003","article-title":"The major determinants in normal and pathological gait","volume":"35","author":"Saunders","year":"1953","journal-title":"J. Bone. Joint. Surg. Am"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/0021-9290(73)90029-8","article-title":"Accelerometry\u2014A technique for the measurement of human body movement","volume":"6","author":"Morris","year":"1973","journal-title":"J. Biomech"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1109\/T-ED.1979.19795","article-title":"A batch-fabricated silicon accelerometer","volume":"26","author":"Roylance","year":"1979","journal-title":"IEEE. Trans. Electron. Devices"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"\u00d6berg, P\u00c5, Togawa, T, and Spelman, FA (2004). Sensors in Medicine and Health Care, Wiley-VCH. Weinheim.","DOI":"10.1002\/3527601414"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1016\/j.medengphy.2008.09.005","article-title":"Direct measurement of human movement by accelerometry","volume":"30","author":"Godfrey","year":"2008","journal-title":"Med. Eng. Phys"},{"key":"ref_14","unstructured":"Gemperle, F, Kasabach, C, Stivoric, J, Bauer, M, and Martin, R (1998, January 19\u201320). Design for wearability. Pittsburg, PA, USA."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1109\/TBME.2003.812189","article-title":"Ambulatory system for human motion analysis using a kinematic sensor: Monitoring of daily physical activity in the elderly","volume":"50","author":"Najafi","year":"2003","journal-title":"IEEE. Trans. Biomed. Eng"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1109\/TITB.2005.856864","article-title":"Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring","volume":"10","author":"Karantonis","year":"2006","journal-title":"IEEE. Trans. Inf. Technol. Biomed"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1089\/tmj.2008.0060","article-title":"Development of a wearable motion detector for telemonitoring and real-time identification of physical activity","volume":"15","author":"Yang","year":"2009","journal-title":"Telemed. J. E. Health"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S1350-4533(00)00041-2","article-title":"Classification of waist-acceleration signals in a continuous walking record","volume":"22","author":"Sekine","year":"2000","journal-title":"Med. Eng. Phys"},{"key":"ref_19","first-page":"157","article-title":"Activity and sleeping time monitored by an accelerometer in rotating shift workers","volume":"30","author":"Kawada","year":"2008","journal-title":"Work"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s10877-005-0392-8","article-title":"Analysis of nighttime activity and daytime pain in patients with chronic back pain using a self-organizing map neural network","volume":"19","author":"Martin","year":"2005","journal-title":"J. Clin. Monit. Comput"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1109\/TITB.2009.2027231","article-title":"An Accelerometer-based device for sleep apnea screening","volume":"14","author":"Morillo","year":"2010","journal-title":"IEEE. Trans. Inf. Technol. Biomed"},{"key":"ref_22","first-page":"A40","article-title":"Validation of the AMP331 monitor for assessing energy expenditure of free-living physical activity","volume":"77","author":"Park","year":"2006","journal-title":"Res. Quart. Exerc. Sport"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.gaitpost.2008.09.014","article-title":"Measuring distance walked and step count in children with cerebral palsy: An evaluation of two portable activity monitors","volume":"29","author":"Kuo","year":"2009","journal-title":"Gait Posture"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1007\/BF02351026","article-title":"Evaluation of a fall detector based on accelerometers: A pilot study","volume":"43","author":"Lindemann","year":"2005","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1093\/ageing\/32.2.137","article-title":"Age-related differences in walking stability","volume":"32","author":"Menz","year":"2003","journal-title":"Age Ageing"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1093\/gerona\/58.5.M446","article-title":"Acceleration patterns of the head and pelvis when walking are associated with risk of falling in community-dwelling older people","volume":"58","author":"Menz","year":"2003","journal-title":"J. Gerontol. A. Biol. Sci. Med. Sci"},{"key":"ref_27","unstructured":"Noury, N, Dittmar, A, Corroy, C, Baghai, R, Weber, JL, Blanc, D, Klefstat, F, Blinovska, A, Vaysse, S, and Comet, B (2004, January 1\u20135). VTAMN-A smart clothe for ambulatory remote monitoring of physiological parameters and activity. San Francisco, CA, USA."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"307","DOI":"10.3233\/THC-1997-5404","article-title":"Computerized analysis of daily life motor activity for ambulatory monitoring","volume":"5","author":"Kiani","year":"1997","journal-title":"Technol. Health. Care"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1007\/BF02347551","article-title":"Classification of basic daily movements using a triaxal accelerometer","volume":"42","author":"Mathie","year":"2004","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1109\/86.547939","article-title":"Detection of static and dynamic activities using uniaxial accelerometers","volume":"4","author":"Veltink","year":"1996","journal-title":"IEEE. Trans. Rehabil. Eng"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/S0747-5632(99)00037-0","article-title":"Detection of posture and motion by accelerometry: A validation study in ambulatory monitoring","volume":"15","author":"Foerster","year":"1999","journal-title":"Comput. Human. Behav"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.medengphy.2004.11.006","article-title":"A description of an accelerometer-based mobility monitoring technique","volume":"27","author":"Lyons","year":"2005","journal-title":"Med. Eng. Phys"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1109\/TBME.2002.800763","article-title":"Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly","volume":"49","author":"Najafi","year":"2002","journal-title":"IEEE. Trans. Biomed. Eng"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1007\/s00542-005-0502-z","article-title":"Automatic classification of ambulatory movements and evaluation of energy consumptions utilizing accelerometers and a barometer","volume":"11","author":"Ohtaki","year":"2005","journal-title":"Microsyst. Technol"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1093\/ptj\/78.9.989","article-title":"Validity and reliability of measurements obtained with an \u201cactivity monitor\u201d in people with and without a transtibial amputation","volume":"78","author":"Bussmann","year":"1998","journal-title":"Phys. Ther"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/j.humov.2008.12.003","article-title":"Support vector machine for classification of walking conditions of persons after stroke with dropped foot","volume":"28","author":"Lau","year":"2009","journal-title":"Hum. Mov. Sci"},{"key":"ref_37","first-page":"858","article-title":"Fall detection by wearable sensor and one-class SVM algorithm","volume":"345","author":"Zhang","year":"2006","journal-title":"Intel. Comput. Signal Process. Pattern Recognit"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Huynh, T, and Schiele, B (2006, January 11\u201314). Towards less supervision in activity recognition from wearable sensors. Montreux, Switzerland.","DOI":"10.1109\/ISWC.2006.286336"},{"key":"ref_39","unstructured":"Long, X, Yin, B, and Aarts, RM (2009, January 2\u20136). Single-accelerometer-based daily physical activity classification. Minneapolis, MN, USA."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1088\/0967-3334\/27\/10\/001","article-title":"Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models","volume":"27","author":"Allen","year":"2006","journal-title":"Physiol. Meas"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.3390\/s100201154","article-title":"Machine learning methods for classifying human physical activity from On-Body Accelerometers","volume":"10","author":"Mannini","year":"2010","journal-title":"Sensors"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1249\/01.mss.0000227542.43669.45","article-title":"Development of novel techniques to classify physical activity mode using accelerometers","volume":"38","author":"Pober","year":"2006","journal-title":"Med. Sci. Sports Exerc"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/01.hjr.0000161551.73095.9c","article-title":"How to assess physical activity? How to assess physical fitness?","volume":"12","author":"Vanhees","year":"2005","journal-title":"Eur. J. Cardiovasc. Prev. Rehabil"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1249\/00005768-199412000-00016","article-title":"Assessment of energy expenditure for physical activity using a triaxial accelerometer","volume":"26","author":"Bouten","year":"1994","journal-title":"Med. Sci. Sports. Exerc"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1109\/10.554760","article-title":"A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity","volume":"44","author":"Bouten","year":"1997","journal-title":"IEEE. Trans. Biomed. Eng"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2371","DOI":"10.1038\/oby.2007.281","article-title":"Physical activity assessment with accelerometers: An evaluation against doubly labeled water","volume":"15","author":"Plasqui","year":"2007","journal-title":"Obesity"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1007\/s00421-006-0307-5","article-title":"Estimating energy expenditure using accelerometers","volume":"98","author":"Crouter","year":"2006","journal-title":"Eur. J. Appl. Physiol"},{"key":"ref_48","first-page":"1","article-title":"The prevention of falls in later life. A report of the Kellogg International Work Group on the prevention of falls by the elderly","volume":"34","author":"Gibson","year":"1987","journal-title":"Dan Med Bull"},{"key":"ref_49","unstructured":"Williams, G, Doughty, K, Cameron, K, and Bradley, DA (November, January 29). A smart fall and activity monitor for telecare applications. Hong Kong."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1258\/1357633001934483","article-title":"The design of a practical and reliable fall detector for community and institutional telecare","volume":"6","author":"Doughty","year":"2000","journal-title":"J. Telemed. Telecare"},{"key":"ref_51","first-page":"1073","article-title":"Clinical and laboratory measures of postural balance in an elderly population","volume":"73","author":"Berg","year":"1992","journal-title":"Arch. Phys. Med. Rehabil"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1093\/ptj\/83.3.237","article-title":"A physiological profile approach to fall risk assessment and prevention","volume":"83","author":"Lord","year":"2003","journal-title":"Phys. Ther"},{"key":"ref_53","unstructured":"Sherrington, C (2000). The Effect of Exercise on Physical Ability Following Fall-Related Hip fracture, PhD thesis,."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1016\/S0003-9993(95)80075-1","article-title":"Age and gender effects on postural control measures","volume":"76","author":"Hageman","year":"1995","journal-title":"Arch. Phys. Med. Rehabil"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1080\/00140130050174491","article-title":"Stabilographic analysis of unconstrained standing","volume":"43","author":"Duarte","year":"2000","journal-title":"Ergonomics"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1093\/ptj\/75.8.699","article-title":"Changes in the mean center of balance during balance testing in young adults","volume":"75","author":"Nichols","year":"1995","journal-title":"Phys. Ther"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/S0966-6362(01)00199-0","article-title":"Standing balance evaluation using a triaxial accelerometer","volume":"16","author":"Mayagoitia","year":"2002","journal-title":"Gait Posture"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1002\/pri.289","article-title":"Forceplate and accelerometer measures for evaluating the effect of muscle fatigue on postural control during one-legged stance","volume":"8","author":"Adlerton","year":"2003","journal-title":"Physiother Res Int"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/BF02446305","article-title":"Recording accelerations in body movement","volume":"29","author":"Evans","year":"1991","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_60","first-page":"389","article-title":"Accelerometric gait analysis for use in hospital outpatients","volume":"66","author":"Auvinet","year":"1999","journal-title":"Rev. Rhum. Engl. Ed"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1007\/BF02513368","article-title":"Temporal feature estimation during walking using miniature accelerometers: An analysis of gait improvement after hip arthroplasty","volume":"37","author":"Aminian","year":"1999","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S0021-9290(02)00008-8","article-title":"Spatial-temporal parameters of gait measured by an ambulatory system using miniature gyroscope","volume":"35","author":"Aminian","year":"2002","journal-title":"J. Biomech"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0021-9290(03)00233-1","article-title":"Estimation of gait cycle characteristics by trunk accelerometry","volume":"37","author":"Helbostad","year":"2004","journal-title":"J. Biomech"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00221-003-1450-4","article-title":"Balance and gait in children with dyslexia","volume":"150","author":"Helbostad","year":"2003","journal-title":"Exp. Brain. Res"},{"key":"ref_65","first-page":"285","article-title":"Accelerometric analysis of several types of walking","volume":"50","author":"Smidt","year":"1971","journal-title":"Am. J. Phys. Med. Rehabil"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1038\/oby.2007.584","article-title":"The efficacy of a technology-based system in a short-term behavioral weight loss intervention","volume":"15","author":"Polzien","year":"2007","journal-title":"Obesity"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1249\/MSS.0b013e31818896f4","article-title":"Energy cost in children assessed by multisensory activity monitors","volume":"41","author":"Arvidsson","year":"2009","journal-title":"Med. Sci. Sports. Exerc"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s10916-007-9111-y","article-title":"Context awareness of human motion states using accelerometer","volume":"32","author":"Jin","year":"2008","journal-title":"J. Med. Syst"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1249\/01.MSS.0000117158.14542.E7","article-title":"Validation of the RT3 triaxial accelerometer for the assessment of physical activity","volume":"36","author":"Rowlands","year":"2004","journal-title":"Med. Sci. Sports. Exerc"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1080\/15412550902755044","article-title":"Methodology for using long-term accelerometry monitoring to describe daily activity patterns in COPD","volume":"6","author":"Hecht","year":"2009","journal-title":"COPD J. Chronic Obstructive Pulm. Dis"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/j.hrtlng.2009.01.005","article-title":"Influence of a symptom management telehealth intervention on older adults' early recovery outcomes after coronary artery bypass surgery","volume":"38","author":"Barnason","year":"2009","journal-title":"Heart Lung"},{"key":"ref_72","first-page":"226","article-title":"Preliminary evidence of physical activity levels measured by accelerometer in Spanish adolescents; the AFINOS Study","volume":"24","author":"Welk","year":"2009","journal-title":"Nutr. Hosp"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1123\/japa.11.3.293","article-title":"Initial validation of the CSA activity monitor during rehabilitation exercise among older adults with chronic disease","volume":"11","author":"Focht","year":"2003","journal-title":"J. Aging. Phys. Act"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.jclinepi.2005.11.020","article-title":"Clinimetric review of motion sensors in children and adolescents","volume":"59","author":"Bakker","year":"2006","journal-title":"J. Clin. Epidemiol"},{"key":"ref_75","first-page":"1","article-title":"Physical exercise, fitness and dietary pattern and their relationship with circadian blood pressure pattern, augmentation index and endothelial dysfunction biological markers: Evident study protocol","volume":"10","year":"2010","journal-title":"BMC. Public Health"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.ypmed.2005.07.006","article-title":"Precision and accuracy of an ankle-worn accelerometer-based pedometer in step counting and energy expenditure","volume":"41","author":"Foster","year":"2005","journal-title":"Prev. Med"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1249\/mss.0b013e318158b504","article-title":"Gait speed and step-count monitor accuracy in community-dwelling older adults","volume":"40","author":"Storti","year":"2008","journal-title":"Med. Sci. Sports Exerc"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s00421-005-0018-3","article-title":"Comparison of two waist-mounted and two ankle-mounted electronic pedometers","volume":"95","author":"Karabulut","year":"2005","journal-title":"Eur. J. Appl. Physiol"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1136\/bjsm.2006.027276","article-title":"The validity and reliability of a novel activity monitor as a measure of walking","volume":"40","author":"Ryan","year":"2006","journal-title":"Br. J. Sports. Med"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.medengphy.2006.10.001","article-title":"Comparison of the performance of the activPAL(TM) Professional physical activity logger to a discrete accelerometer-based activity monitor","volume":"29","author":"Godfrey","year":"2007","journal-title":"Med. Eng. Phys"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1123\/japa.16.2.201","article-title":"Activity-monitor accuracy in measuring step number and cadence in community-dwelling older adults","volume":"16","author":"Grant","year":"2008","journal-title":"J. Aging. Phys. Act"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-6-47","article-title":"Physical activity monitoring in obese people in the real life environment","volume":"6","author":"Benedetti","year":"2009","journal-title":"J. Neuroeng. Rehabil"},{"key":"ref_83","first-page":"1","article-title":"Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor","volume":"13","author":"Huddleston","year":"2006","journal-title":"J. Neuroeng. Rehabil"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1249\/01.MSS.0000126585.40962.22","article-title":"Improving energy expenditure estimation for physical activity","volume":"36","author":"Zhang","year":"2004","journal-title":"Med. Sci. Sports Exerc"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1109\/MEMB.2008.919494","article-title":"Quantitative evaluation of movement using the timed up-and-go test","volume":"27","author":"Higashi","year":"2008","journal-title":"IEEE. Eng. Med. Biol. Mag"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1007\/s10439-005-9068-2","article-title":"A review of approaches to mobility telemonitoring of the elderly in their living environment","volume":"34","author":"Carew","year":"2006","journal-title":"Ann. Biomed. Eng"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/8\/7772\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:03:11Z","timestamp":1760220191000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/8\/7772"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,8,20]]},"references-count":86,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2010,8]]}},"alternative-id":["s100807772"],"URL":"https:\/\/doi.org\/10.3390\/s100807772","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,8,20]]}}}