{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:39:03Z","timestamp":1760243943532,"version":"build-2065373602"},"reference-count":13,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2010,9,9]],"date-time":"2010-09-09T00:00:00Z","timestamp":1283990400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper we present a hydraulic load cell made from hydroformed metallic bellows. The load cell was designed for a small kitchen appliance with the weighing function integrated into the composite control and protection of the appliance. It is a simple, low-cost solution with small dimensions and represents an alternative to the existing hydraulic load cells in industrial use. A good non-linearity and a small hysteresis were achieved. The influence of temperature leads to an error of 7.5%, which can be compensated for by software to meet the requirements of the target application.<\/jats:p>","DOI":"10.3390\/s100908452","type":"journal-article","created":{"date-parts":[[2010,9,19]],"date-time":"2010-09-19T09:41:46Z","timestamp":1284889306000},"page":"8452-8465","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A High-Sensitivity Hydraulic Load Cell for Small Kitchen Appliances"],"prefix":"10.3390","volume":"10","author":[{"given":"Roman","family":"Pa\u010dnik","sequence":"first","affiliation":[{"name":"BSH Hi\u0161ni aparati d.o.o., Savinjska cesta 30, 3331 Nazarje, Slovenia"}]},{"given":"Franc","family":"Novak","sequence":"additional","affiliation":[{"name":"Jo\u017eef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia"}]}],"member":"1968","published-online":{"date-parts":[[2010,9,9]]},"reference":[{"key":"ref_1","unstructured":"Fraden, J (2004). Handbook of Modern Sensors: Physics, Designs, and Applications, Springer. [3rd ed]."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/S0079-6425(00)00011-6","article-title":"The selection of sensors","volume":"46","author":"Shieh","year":"2001","journal-title":"Prog. Mater. Sci"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Lipt\u00e1k, BG (2003). Instrument Engineers\u2019 Handbook Volume 1, Process Measurement and Analysis, CRC Press. [4th ed].","DOI":"10.1201\/9781420064025"},{"key":"ref_4","unstructured":"(1998). Transactions in Measurements and Control\u2013\u2013\u2013Force-Related Measurements, OMEGA Press. Available online: http:\/\/www.omega.com\/literature\/transactions\/Transactions_Vol_III.pdf (accessed on 12 May 2010)."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0924-4247(99)00079-5","article-title":"Low creep and hysteresis load cell based on a force-to-fluid pressure transformation","volume":"78","author":"Zwijze","year":"1999","journal-title":"Sens. Actuator. A"},{"key":"ref_6","unstructured":"International Organisation of Legal Metrology OIML R60: Metrological Regulation for Load Cells, OIML, 2000. Available online: http:\/\/www.oiml.org\/publications\/R\/R060-e00.pdf (accessed on 15 March 2010)."},{"key":"ref_7","unstructured":"Hoffmann, K (1989). An Introduction to Measurements Using Strain Gages, Hottinger Baldwin Messtechnik."},{"key":"ref_8","unstructured":"Moaveni, S (2008). Finite Element Analysis: Theory and Application with ANSYS, Pearson Prentice Hall. [3rd ed]."},{"key":"ref_9","unstructured":"Measurements specialties. Available online: http:\/\/www.meas-spec.com\/product\/t_product.aspx?id=6769# (accessed on 15 March 2010)."},{"key":"ref_10","unstructured":"Makabe, M, and Kohashi, T (2004, January 4\u20136). Practical creep and hysteresis error compensation method for load cell. Sapporo, Japan."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"697","DOI":"10.3390\/s6070697","article-title":"Improving the response of a load cell by using optimal filtering","volume":"6","author":"Hernandez","year":"2006","journal-title":"Sensors"},{"key":"ref_12","unstructured":"Stratton, TG Low TCE Fill Fluid for Barrier Diaphragm Pressure Sensor, US Patent Appl, 2004187586, 26 April 2005."},{"key":"ref_13","unstructured":"Measurements specialties. Available online: http:\/\/www.meas-spec.com\/product\/t_product.aspx?id=6751 (accessed on 20 May 2010)."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/9\/8452\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:03:20Z","timestamp":1760220200000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/9\/8452"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9,9]]},"references-count":13,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2010,9]]}},"alternative-id":["s100908452"],"URL":"https:\/\/doi.org\/10.3390\/s100908452","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2010,9,9]]}}}