{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T15:21:20Z","timestamp":1783610480223,"version":"3.55.0"},"reference-count":53,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2010,11,18]],"date-time":"2010-11-18T00:00:00Z","timestamp":1290038400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>We present the most recent advances in photo-detector design employed in time of flight positron emission tomography (ToF-PET). PET is a molecular imaging modality that collects pairs of coincident (temporally correlated) annihilation photons emitted from the patient body. The annihilation photon detector typically comprises a scintillation crystal coupled to a fast photo-detector. ToF information provides better localization of the annihilation event along the line formed by each detector pair, resulting in an overall improvement in signal to noise ratio (SNR) of the reconstructed image. Apart from the demand for high luminosity and fast decay time of the scintillation crystal, proper design and selection of the photo-detector and methods for arrival time pick-off are a prerequisite for achieving excellent time resolution required for ToF-PET. We review the two types of photo-detectors used in ToF-PET: photomultiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) with a special focus on SiPMs.<\/jats:p>","DOI":"10.3390\/s101110484","type":"journal-article","created":{"date-parts":[[2010,11,18]],"date-time":"2010-11-18T11:53:33Z","timestamp":1290081213000},"page":"10484-10505","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":96,"title":["Photo-Detectors for Time of Flight Positron Emission Tomography (ToF-PET)"],"prefix":"10.3390","volume":"10","author":[{"given":"Virginia Ch.","family":"Spanoudaki","sequence":"first","affiliation":[{"name":"Molecular Imaging Program at Stanford (MIPS) and Department of Radiology, Stanford University, 300 Pasteur Drive 94305, Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig S.","family":"Levin","sequence":"additional","affiliation":[{"name":"Molecular Imaging Program at Stanford (MIPS) and Department of Radiology, Stanford University, 300 Pasteur Drive 94305, Stanford, CA 94305, USA"},{"name":"Departments of Electrical Engineering and Physics, Stanford University, Stanford, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2010,11,18]]},"reference":[{"key":"ref_1","unstructured":"Cherry, S, Sorenson, J, and Phelps, M (2003). Physics in Nuclear Medicine, Elsevier Health Science."},{"key":"ref_2","first-page":"73","article-title":"Time-of-flight positron emission tomography-status relative to conventional PET","volume":"24","author":"Budinger","year":"1983","journal-title":"J. Nucl. Med"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1109\/TNS.1981.4331148","article-title":"System design of fast PET scanners utilizing time-of-flight","volume":"28","author":"Mullani","year":"1981","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.nima.2007.06.038","article-title":"Recent Advances and Future Advances in Time-of-Flight PET","volume":"580","author":"Moses","year":"2007","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1088\/0031-9155\/44\/3\/019","article-title":"Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution","volume":"44","author":"Levin","year":"1999","journal-title":"Phys. Med. Biol"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"462","DOI":"10.2967\/jnumed.107.044834","article-title":"Benefit of time-of-flight in PET: Experimental and clinical results","volume":"49","author":"Karp","year":"2008","journal-title":"J. Nucl. Med"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1109\/TMI.2006.871419","article-title":"Investigation of Time-of-Flight Benefit for fully 3D PET","volume":"25","author":"Surti","year":"2006","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1088\/0031-9155\/54\/2\/013","article-title":"Experimental evaluation of a simple lesion detection task with time-of-flight","volume":"54","author":"Surti","year":"2009","journal-title":"Phys. Med. Biol"},{"key":"ref_9","unstructured":"Knoll, G (2001). Radiation Detection and Measurement, Wiley."},{"key":"ref_10","unstructured":"Paulus, T (1982). Principles and Applications of Timing Spectroscopy. Application Note AN-42, EG&E."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/0029-554X(66)90187-X","article-title":"Comparison of leading-edge and crossover timing in coincidence measurements","volume":"42","author":"Bell","year":"1966","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1109\/TNS.2008.2008992","article-title":"Fast Photomultipliers for TOF PET","volume":"56","author":"Szczesniak","year":"2009","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1109\/23.856531","article-title":"Measurements of the Intrinsic Rise Times of Common Inorganic Scintillators","volume":"47","author":"Derenzo","year":"2000","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.1016\/j.jcrysgro.2007.10.075","article-title":"The effect of co-doping in the growth stability and scintillation properties of lutetium oxyorthosilicate","volume":"310","author":"Spurrier","year":"2008","journal-title":"J. Cryst. Growth"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1109\/TNS.2009.2035620","article-title":"Timing resolution and decay time of LSO crystals co-doped with calcium","volume":"57","author":"Szczesniak","year":"2010","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2972","DOI":"10.1109\/TNS.2009.2028235","article-title":"Energy Resolution of Calcium Co-doped LSO:Ce Scintillators","volume":"56","author":"Moszynski","year":"2009","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1063\/1.1385342","article-title":"High-energy-resolution scintillator: Ce3+ activated LaBr3","volume":"79","author":"Dorenbos","year":"2001","journal-title":"Appl. Phys. Lett"},{"key":"ref_18","unstructured":"Saint Gobain Available online: http:\/\/www.detectors.saint-gobain.com (accessed on 25 October 2010)."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1109\/TNS.2004.835777","article-title":"Design of a lanthanum bromide detector for time-of-flight PET","volume":"51","author":"Kuhn","year":"2004","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"N179","DOI":"10.1088\/0031-9155\/55\/7\/N02","article-title":"LaBr3:Ce and SiPMs: achieving 100 ps coincidence resolving time","volume":"55","author":"Schaart","year":"2010","journal-title":"Phys. Med. Biol"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1088\/0031-9155\/55\/1\/004","article-title":"The imaging performance of a LaBr3-based PET scanner","volume":"55","author":"Surti","year":"2010","journal-title":"Phys. Med. Biol"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/0167-5087(83)91254-1","article-title":"Barium Fluoride - Inorganic scintillator for subnanosecond timing","volume":"206","author":"Laval","year":"1983","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1109\/23.106679","article-title":"Effects of scintillation collection on the time resolution of a time-of-flight detector for annihilation quanta","volume":"37","author":"Ziegler","year":"1990","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_24","unstructured":"Wernick, M, and Aarsvold, J (2004). Emission Tomography: The fundamentals of PET and SPECT, Elsevier Academic Press."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.nima.2006.05.060","article-title":"Geiger-mode avalanche photodiodes, history, properties and problems","volume":"567","author":"Renker","year":"2006","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1109\/TNS.2006.875999","article-title":"New Prospects for Time-of-Flight PET With LSO Scintillators","volume":"53","author":"Moszynski","year":"2006","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.nima.2006.10.016","article-title":"New trends on photodetectors","volume":"571","author":"Renker","year":"2007","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1109\/TNS.2010.2044586","article-title":"Multi Pixel Photon Counters (MPPC) as an Alternative to APD in PET Applications","volume":"57","author":"Nassalski","year":"2010","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2580","DOI":"10.1109\/TNS.2009.2028075","article-title":"Multi-Pixel Photon Counters for TOF PET Detector and Its Challenges","volume":"56","author":"Kim","year":"2009","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2434","DOI":"10.1109\/TNS.2009.2024418","article-title":"Silicon Photomultiplier Technology at STMicroelectronics","volume":"56","author":"Mazillo","year":"2009","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1109\/TNS.2006.887115","article-title":"Characterization of the First Prototypes of Silicon Photomultiplier Fabricated at ITC-irst","volume":"54","author":"Piemonte","year":"2007","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1109\/JQE.2007.910940","article-title":"Performance of 1-mm2 Silicon Photomultiplier","volume":"44","author":"Stewart","year":"2008","journal-title":"IEEE J. Quantum Electron"},{"key":"ref_33","unstructured":"Otte, A (2007). Observation of VHE \u03b3-Rays from the Vicinity of Magnetized Neutron Stars and Development of New Photon-Detectors for Future Ground based \u03b3-Ray Detectors, PhD thesis, Technische Universitaet Muenchen, Germany."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Spanoudaki, V, Mann, A, Otte, A, Konorov, I, Torres-Espallardo, I, McElroy, DP, and Ziegler, SI (2007). Use of single photon counting detector arrays in combined PET\/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector. J Instrum, P12002.","DOI":"10.1088\/1748-0221\/2\/12\/P12002"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1364\/AO.35.001956","article-title":"Avalanche photodiodes and quenching circuits for single-photon detection","volume":"35","author":"Cova","year":"1996","journal-title":"Applied Opt"},{"key":"ref_36","unstructured":"Sze, S (1981). Physics of semiconductor devices, Wiley Interscience."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1109\/TNS.2008.922220","article-title":"Thermal and Electrical Characterization of Silicon Photomultiplier","volume":"55","author":"Petasecca","year":"2008","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.nima.2010.03.141","article-title":"Temperature characterization of scintillation detectors using solid-state photomultipliers for radiation monitoring applications","volume":"620","author":"Tur","year":"2010","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.nima.2008.08.130","article-title":"After-pulsing and cross-talk in multi-pixel photon counters","volume":"596","author":"Du","year":"2008","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.nima.2009.05.085","article-title":"On the efficiency of photon emission during electrical breakdown in silicon","volume":"610","author":"Otte","year":"2009","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1016\/j.nima.2006.10.298","article-title":"The Avalanche drift diode-A backilluminated Silicon Photomultiplier","volume":"572","author":"Ninkovic","year":"2007","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.nima.2006.07.018","article-title":"A new Silicon Photomultiplier structure for blue light detection","volume":"568","author":"Piemonte","year":"2006","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.nima.2009.10.025","article-title":"SiMPI\u2013 An avalanche diode array with bulk integrated quench resistors for single photon detection","volume":"617","author":"Ninkovic","year":"2010","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.nima.2009.05.150","article-title":"The cross-talk problem in SiPMs and their use as light sensors for imaging atmospheric Cherenkov telescopes","volume":"610","author":"Buzhan","year":"2009","journal-title":"Nucl. Instr. Meth. Phys. Res. A"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1109\/TNS.2008.922812","article-title":"Novel Silicon Photomultipliers for PET Applications","volume":"55","author":"Llosa","year":"2008","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_46","first-page":"471","article-title":"Performance of Philips Gemini TF PET\/CT Scanner with Special Consideration for Its Time-of-Flight Imaging Capabilities","volume":"48","author":"Surti","year":"2007","journal-title":"J. Nucl. Med"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Jakoby, B, Bercier, Y, Conti, M, Casey, M, Gremillion, T, Hayden, C, Bendriem, B, and Townsend, DW (2008, January October). Performance Investigation of a Time-of-Flight PET\/CT Scanner. Dresden, Germany.","DOI":"10.1109\/NSSMIC.2008.4774221"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Wilson, J, and Turkington, T (2009\u2013November, January October). TOF-PET Small-Lession Image Quality Measured Over a Range of Phantom Sizes. Orlando, FL, USA.","DOI":"10.1109\/NSSMIC.2009.5401866"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Degenhardt, C, Prescher, G, Frach, T, Thon, A, de Gruyter, R, Schmitz, A, and Ballizany, R (2009\u2013November, January October). The Digital Silicon Photomultiplier\u2013A Novel sensor for the Detection of Scintillation Light. Orlando, FL, USA.","DOI":"10.1109\/NSSMIC.2009.5402190"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Frach, T, Prescher, G, Degenhardt, C, de Gruyter, R, Schmitz, A, and Ballizany, R (2009\u2013November, January October). The Digital Silicon Photomultiplier\u2013Principle of Operation and Intrinsic Detector Performance. Orlando, FL, USA.","DOI":"10.1109\/NSSMIC.2009.5402143"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1109\/JSSC.2009.2021920","article-title":"Single-photon synchronous detection","volume":"44","author":"Niclass","year":"2009","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1117\/12.591746","article-title":"Ultra low noise photodetectors with internal discrete amplification","volume":"5726","author":"Linga","year":"2005","journal-title":"Proc. SPIE"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Linga, K, Godik, E, Krutovl, J, Shushakov, D, Shubin, VE, Vinogradov, SL, and Levin, EV (2006). Solid State Photomiltiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification. Proc SPIE, 6119.","DOI":"10.1117\/12.648755"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/11\/10484\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:03:53Z","timestamp":1760220233000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/11\/10484"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,18]]},"references-count":53,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2010,11]]}},"alternative-id":["s101110484"],"URL":"https:\/\/doi.org\/10.3390\/s101110484","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,18]]}}}