{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T13:21:03Z","timestamp":1765545663196,"version":"build-2065373602"},"reference-count":16,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2010,12,24]],"date-time":"2010-12-24T00:00:00Z","timestamp":1293148800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ) system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS\/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges nd the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented.<\/jats:p>","DOI":"10.3390\/s110100162","type":"journal-article","created":{"date-parts":[[2010,12,26]],"date-time":"2010-12-26T13:29:00Z","timestamp":1293370140000},"page":"162-179","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Position-Controlled Data Acquisition Embedded System for Magnetic NDE of Bridge Stay Cables"],"prefix":"10.3390","volume":"11","author":[{"given":"Rocio","family":"Maldonado-Lopez","sequence":"first","affiliation":[{"name":"Empa, Swiss Federal Laboratories for Materials Science and Technology, Structural Engineering Research Laboratory, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rouven","family":"Christen","sequence":"additional","affiliation":[{"name":"Empa, Swiss Federal Laboratories for Materials Science and Technology, Structural Engineering Research Laboratory, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2010,12,24]]},"reference":[{"key":"ref_1","first-page":"155","article-title":"Electromagnetic testing, a reliable method for the inspection of wire ropes in service","volume":"22","author":"Weischedel","year":"1989","journal-title":"NDT Int"},{"key":"ref_2","first-page":"48","article-title":"Magnetic flux leakage device for offshore oil pipeline defect inspection","volume":"44","author":"Tao","year":"2005","journal-title":"Mater. Perform"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1109\/20.996088","article-title":"Recent advancement of electromagnetic nondestructive inspection technology in Japan","volume":"38","author":"Miya","year":"2002","journal-title":"IEEE Trans. Magn"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1109\/20.996326","article-title":"Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT)","volume":"38","author":"Park","year":"2002","journal-title":"IEEE Trans. Magn"},{"key":"ref_5","unstructured":"Bergamini, A. (, January March). Nondestructive testing of stay cables\u2014field experience in south east Asia. Como, Italy."},{"key":"ref_6","unstructured":"Kundu, T. (2003, January 1). A simple approach to the localization of flaws in large diameter steel cables. San Diego, CA, USA."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1023\/B:JONE.0000010736.74285.b6","article-title":"Three-dimensional localization of defects in stay cables using magnetic flux leakage methods","volume":"22","author":"Christen","year":"2003","journal-title":"J. Nondestruct. Eval"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/j.ndteint.2006.03.007","article-title":"Automatic flaw detection in NDE signals using a panel of neural networks","volume":"39","author":"Christen","year":"2006","journal-title":"Ndt E Int"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.ndteint.2008.08.003","article-title":"Influence of steel wrapping on magneto-inductive testing of the main cables of suspension bridges","volume":"42","author":"Christen","year":"2009","journal-title":"Ndt E Int"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1106\/AVHK-TLR4-6PTQ-QGXY","article-title":"Wireless monitoring of cable tension of cable-stayed bridges using PVDF piezoelectric films","volume":"12","author":"Liao","year":"2001","journal-title":"J. Intel. Mat. Syst. Struct"},{"key":"ref_11","unstructured":"SD association Available online: http:\/\/www.sdcard.org (accessed on 10 August 2010)."},{"key":"ref_12","unstructured":"Cadsoft computer GmbH. Available online: http:\/\/www.cadsoft.de (accessed on 30 August 2010)."},{"key":"ref_13","unstructured":"(2006). MSP430x1xx Family User\u2019s Guide\u2014Application Report SLAU049F, Texas Instruments."},{"key":"ref_14","unstructured":"SD Group and SD Card Association (2006). SD Specifications Part1: Physical Layer Simplified Specification, Matsushita Electric Industrial Co., Ltd. [2 ed]."},{"key":"ref_15","unstructured":"Schauer, S., and Speck, C. (2008). Interfacing the MSP430 with MMC\/SD Flash Memory Cards\u2014Application Report SLAA281B, Texas Instruments."},{"key":"ref_16","unstructured":"Van der Sloten, J., Verdonck, P., Nyssen, M., and Haueisen, J. (2008, January 23\u201327). iNODE: Intelligent Network operating device for neurological and neurophysiological research. Antwerp, Belgium."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/162\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:04:13Z","timestamp":1760220253000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/162"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12,24]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2011,1]]}},"alternative-id":["s110100162"],"URL":"https:\/\/doi.org\/10.3390\/s110100162","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2010,12,24]]}}}