{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T07:34:10Z","timestamp":1776324850033,"version":"3.50.1"},"reference-count":41,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2011,1,18]],"date-time":"2011-01-18T00:00:00Z","timestamp":1295308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Plasticised poly(vinyl chloride)-based membranes containing the ionophores (\u03b1-, \u03b2- and \u03b3-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when \u03b2- and \u03b3-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on \u03b2-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10\u22125 to 1 x 10\u22122 M, slope was 61.3 mV decade\u22121, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10\u22126 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on \u03b2-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer\u2019s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.<\/jats:p>","DOI":"10.3390\/s110101028","type":"journal-article","created":{"date-parts":[[2011,1,18]],"date-time":"2011-01-18T11:35:06Z","timestamp":1295350506000},"page":"1028-1042","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine"],"prefix":"10.3390","volume":"11","author":[{"given":"Ahmed Khudhair","family":"Hassan","sequence":"first","affiliation":[{"name":"Department of Chemistry, College of Science, Baghdad University, Baghdad, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bahruddin","family":"Saad","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sulaiman Ab","family":"Ghani","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rohana","family":"Adnan","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Afidah Abdul","family":"Rahim","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norariza","family":"Ahmad","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marina","family":"Mokhtar","sequence":"additional","affiliation":[{"name":"School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suham Towfiq","family":"Ameen","sequence":"additional","affiliation":[{"name":"Department of Chemistry, College of Science, Tikrit University, Tikrit, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suad Mustafa","family":"Al-Araji","sequence":"additional","affiliation":[{"name":"Department of Chemistry, College of Science, Baghdad University, Baghdad, Iraq"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0378-4347(01)00559-X","article-title":"Study of the Stability of Promethazine Enantiomers by Liquid Chromatography Using a Vancomycin-Bonded Chiral Stationary Phase","volume":"770","year":"2002","journal-title":"J. Chromatogr. B"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.jchromb.2008.11.017","article-title":"Determination of Phenothiazine Derivatives in Human Urine by Using Ionic Liquid-Based Dynamic Liquid-Phase Microextraction Coupled with Liquid Chromatography","volume":"877","author":"Vera","year":"2009","journal-title":"J. Chromatogr. B"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.aca.2008.06.040","article-title":"Determination of Selected Phenothiazines in Human Plasma by Solid-Phase Extraction and Liquid Chromatography with Coulometric Detection","volume":"624","author":"Saracino","year":"2008","journal-title":"Anal. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jchromb.2007.04.004","article-title":"Simple and Simultaneous Determination for 12 Phenothiazines in Human Serum by Reversed-Phase High-Performance Liquid Chromatography","volume":"854","author":"Tanaka","year":"2007","journal-title":"J. Chromatogr. B"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.aca.2004.11.081","article-title":"Determination of Thiazinamium, Promazine and Promethazine in Pharmaceutical Formulations Using a CZE Method","volume":"535","author":"Lara","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.chroma.2004.11.056","article-title":"Electrophoretic Separations of Twelve Phenothiazines and N-Demethyl Derivatives by Using Capillary Zone Electrophoresis and Micellar Electrokinetic Chromatography with Non Ionic Surfactant","volume":"1063","author":"Le","year":"2005","journal-title":"J. Chromatogr. A"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/j.talanta.2005.03.034","article-title":"A New Spectrophotometric Method for the Determination of Promethazine-Hcl from Pure and Pharmaceutical Preparations","volume":"67","author":"Saif","year":"2005","journal-title":"Talanta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1016\/S0039-9140(03)00016-X","article-title":"Chemiluminescence Assay of Promethazine Hydrochloride Using Acidic Permanganate Employing Flow Injection Mode Operated with Syringe and Peristaltic Pumps","volume":"59","author":"Sultan","year":"2003","journal-title":"Talanta"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/S0003-2670(01)01038-8","article-title":"Voltammetric Determination of Chlorpromazine Hydrochloride and Promethazine Hydrochloride with the Use of Multivariate Calibration","volume":"439","author":"Ni","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/0731-7085(92)80008-B","article-title":"Spectrophotometric Determination of Promethazine by Flow Injection Analysis and Oxidation by CeIV","volume":"10","author":"Calatayud","year":"1992","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1016\/j.jpba.2004.03.010","article-title":"Bead Injection Spectroscopy-Flow Injection Analysis (BIS-FIA): An Interesting Tool Applicable to Pharmaceutical Analysis: Determination of Promethazine and Trifluoperazine","volume":"35","author":"Rama","year":"2004","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1080\/00032719208016129","article-title":"Photochemical Derivatization and Fluorimetric Determination of Promethazine in a FIA Assembly","volume":"25","author":"Romero","year":"1992","journal-title":"Anal. Lett"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/S0003-2670(03)00903-6","article-title":"Flow Injection Spectroelectroanalytical Method for the Determination of Promethazine Hydrochloride in Pharmaceutical Preparations","volume":"494","author":"Daniel","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0003-2670(00)00883-7","article-title":"Ionophore-Based Membrane Electrodes: New Analytical Concepts and Non-Classical Response Mechanism","volume":"416","author":"Bakker","year":"2000","journal-title":"Anal. Chim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.trac.2005.01.003","article-title":"Potentiometric Sensors for Trace-Level Analysis","volume":"24","author":"Bakker","year":"2005","journal-title":"Trac-Trend. Anal. Chem"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.snb.2005.06.011","article-title":"Cobalt(II)-Selective Electrode Based on a Newly Synthesized Macrocyclic Compound","volume":"114","author":"Singh","year":"2006","journal-title":"Sens. Actuat. B"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"521","DOI":"10.2116\/analsci.21.521","article-title":"Flow-Through Chloroquine Sensor and Its Applications in Pharmaceutical Analysis","volume":"21","author":"Saad","year":"2005","journal-title":"Anal. Sci"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1016\/S1452-3981(23)15179-0","article-title":"Promethazine Potentiometric Membrane Sensor for Promethazine Hydrochloride Pharmaceutical Analysis; Computational Study","volume":"4","author":"Ganjali","year":"2009","journal-title":"Int. J. Electrochem. Sci"},{"key":"ref_19","first-page":"539","article-title":"Preparation and Potentiometric Study of Promethazine Hydrochloride Selective Electrodes and Their Use in Determining Some Drugs","volume":"32","author":"Nassory","year":"2008","journal-title":"Turk. J. Chem"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1021\/js970171a","article-title":"Ion-selective Electrodes for Promethazine Determinations in Pharmaceutical Preparations and Application to Flow Injection Analysis","volume":"86","author":"Lima","year":"1997","journal-title":"J. Pharm. Sci"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1093\/jaoac\/90.1.147","article-title":"Phosphorated Calix[6]arene Derivatives as an Ionophore for Atropine-Selective Membrane Electrodes","volume":"90","author":"Zareh","year":"2007","journal-title":"J. AOAC Int"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"604","DOI":"10.3390\/s5120604","article-title":"Determination of Atropine in Injection with B-Cyclodextrin Modified Ion Sensitive Field Effect Transistor Sensor","volume":"5","author":"Li","year":"2005","journal-title":"Sensors"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.snb.2005.11.007","article-title":"Cyclodextrins-Based Enantioselective, Potentiometric Membrane Electrodes for L-Vesamicol Assay in Serum Samples","volume":"117","author":"Stefan","year":"2006","journal-title":"Sens. Actuat. B"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1016\/j.jpba.2008.08.012","article-title":"Cyclodextrin-Based Potentiometric Sensors for Midazolam and Diazepam","volume":"48","author":"Amorim","year":"2008","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.jpba.2007.12.003","article-title":"New Ionophores for Vitamin B1 and Vitamin B6 Potentiometric Sensors for Multivitaminic Control","volume":"46","author":"Pires","year":"2008","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0003-2670(96)00436-9","article-title":"Paraquat Sensors Containing Membrane Components of High Lipophilicities","volume":"338","author":"Saad","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1351\/pac199466122527","article-title":"Recommendations for Nomenclature of Ionselective Electrodes","volume":"66","author":"Buck","year":"1994","journal-title":"Pure Appl. Chem"},{"key":"ref_28","unstructured":"(2005). United States Pharmacopoeia, General Chapter, US Pharmacopoeial Convention."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1248\/cpb.49.669","article-title":"Mechanistic Appraisal of the Charge-Transfer Complexes of Promethazine with Chloranil: A Modelling Approach","volume":"49","author":"Adikwu","year":"2001","journal-title":"Chem. Pharm. Bull"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3630","DOI":"10.1021\/ja00818a042","article-title":"Topography of Cyclodextrin Inclusion Complexes. III. Crystal and Molecular Structure of Cyclohexaamylose Hexadrate, The (H2O)2 Inclusion Complex","volume":"74","author":"Manor","year":"1974","journal-title":"J. Am. Chem. Soc"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"7545","DOI":"10.1021\/ja00336a039","article-title":"Circular and Flip-Flop Hydrogen Bonding in B-Cyclodextrin Undecahydrate: A Neutron Diffraction Study","volume":"106","author":"Betzel","year":"1984","journal-title":"J. Am. Chem. Soc"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2763","DOI":"10.1246\/bcsj.60.2763","article-title":"The Structure of the Cyclodextrin Complex. XX. Crystal Structure of Uncomplexed Hydrated \u0393-Cyclodextrin","volume":"60","author":"Harata","year":"1987","journal-title":"Bull. Chem. Soc. Jpn"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/S0020-1693(96)05407-2","article-title":"Crystal Structures of Complexes of Ammonium and Potassium Hexafluorophosphate with Dibenzo-18-Crown-6. Molecular Mechanics Studies on the Uncomplexed Macrocycle","volume":"252","author":"Dapporto","year":"1996","journal-title":"Inorg. Chim. Acta"},{"key":"ref_34","unstructured":"Frisch, M.J., Trucks, G.W., Schlegel, H.B., Scuseria, G.E., Robb, M.A., Cheeseman, J.R., Montgomery, J.A., Vreven, T., Kudin, K.N., and Burant, J.C. (2003). Gaussian 03, Revision B.03, Gaussian, Inc."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2487","DOI":"10.1016\/S0008-6215(02)00335-X","article-title":"Crystal Structure of B-Cyclodextrin-Dimethylsulfoxide Inclusion Complex","volume":"337","author":"Aree","year":"2002","journal-title":"Carbohydr. Res"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"593","DOI":"10.3390\/s6060593","article-title":"Cyclodextrin Derivatives as Chiral Supramolecular Receptors for Enantioselective Sensing","volume":"6","author":"Shahgaldian","year":"2006","journal-title":"Sensors"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s10847-008-9456-y","article-title":"Cyclodextrin Based Novel Drug Delivery Systems","volume":"62","author":"Vyas","year":"2008","journal-title":"J. Incl. Phenom. Macrocycl. Chem"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"5660","DOI":"10.1002\/anie.200605068","article-title":"Modern Potentiometry","volume":"46","author":"Bakker","year":"2007","journal-title":"Angew. Chem. Int. Ed"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1351\/pac200880010085","article-title":"Performance Evaluation Criteria for Preparation and Measurement of Macro and Microfabricated Ion-Selective Electrodes","volume":"80","author":"Lindner","year":"2008","journal-title":"Pure Appl. Chem"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.jmgm.2007.01.010","article-title":"Molecular Modeling Study of B-Cyclodextrin Complexes with (+)-catechin and (\u2212)-epicatechin","volume":"26","author":"Yan","year":"2007","journal-title":"Mol. Graph. Modell"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1002\/(SICI)1520-636X(1996)8:4<341::AID-CHIR8>3.0.CO;2-I","article-title":"Detailed Experimental and Theoretical Analysis of Chiral Discrimination: Enantioselective Binding of R\/S Methyl Mandelate by B-Cyclodextrin","volume":"8","author":"Lipkowitz","year":"1996","journal-title":"Chirality"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/1028\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:54:57Z","timestamp":1760219697000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/1028"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,18]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2011,1]]}},"alternative-id":["s110101028"],"URL":"https:\/\/doi.org\/10.3390\/s110101028","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,18]]}}}