{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:36:27Z","timestamp":1760243787181,"version":"build-2065373602"},"reference-count":27,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2011,1,20]],"date-time":"2011-01-20T00:00:00Z","timestamp":1295481600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Knowledge of tissue mechanical properties is widely required by medical applications, such as disease diagnostics, surgery operation, simulation, planning, and training. A new portable device, called Tissue Resonator Indenter Device (TRID), has been developed for measurement of regional viscoelastic properties of soft tissues at the Bio-instrument and Biomechanics Lab of the University of Toronto. As a device for soft tissue properties in-vivo measurements, the reliability of TRID is crucial. This paper presents TRID\u2019s working principle and the experimental study of TRID\u2019s reliability with respect to inter-reliability, intra-reliability, and the indenter misalignment effect as well.<\/jats:p>","DOI":"10.3390\/s110101212","type":"journal-article","created":{"date-parts":[[2011,1,20]],"date-time":"2011-01-20T11:51:03Z","timestamp":1295524263000},"page":"1212-1228","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["A New Tissue Resonator Indenter Device and Reliability Study"],"prefix":"10.3390","volume":"11","author":[{"given":"Ming","family":"Jia","sequence":"first","affiliation":[{"name":"Department of Mechanical & Industrial Engineering, University of Toronto\/5 King\u2019s College Road, Toronto, ON M5S 3G8, Canada"}]},{"given":"Jean W.","family":"Zu","sequence":"additional","affiliation":[{"name":"Department of Mechanical & Industrial Engineering, University of Toronto\/5 King\u2019s College Road, Toronto, ON M5S 3G8, Canada"}]},{"given":"Alireza","family":"Hariri","sequence":"additional","affiliation":[{"name":"Department of Mechanical & Industrial Engineering, University of Toronto\/5 King\u2019s College Road, Toronto, ON M5S 3G8, Canada"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1146\/annurev.bioeng.5.040202.121623","article-title":"Selected methods for imaging elastic properties of biological tissues","volume":"5","author":"Greenleaf","year":"2003","journal-title":"Annu. Rev. Biomed. Eng"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2954","DOI":"10.1016\/j.jbiomech.2008.07.034","article-title":"Assessment of in vivo and post-mortem mechanical behavior of brain tissue using magnetic resonance elastography","volume":"41","author":"Vappou","year":"2008","journal-title":"J. Biomech"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/BF02347044","article-title":"Finite element analysis of brain contusion: An indirect impact study","volume":"38","author":"Huang","year":"2000","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_4","first-page":"123","article-title":"Correlation of an FE model of the human head with experiments on localized motion of the brain\u2014consequences for injury prediction","volume":"46","author":"Kleiven","year":"2002","journal-title":"Stapp Car Crash"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0021-9290(01)00202-0","article-title":"Consequences of head size following trauma to the human head","volume":"35","author":"Kleiven","year":"2002","journal-title":"J. Biomech"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.jbiomech.2003.12.032","article-title":"Are in vivo and in situ brain tissues mechanically similar?","volume":"37","author":"Gefen","year":"2004","journal-title":"J. Biomech"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1002\/nbm.1254","article-title":"In vivo brain viscoelastic properties measured by magnetic resonance elastography","volume":"21","author":"Green","year":"2008","journal-title":"NMR Biomed"},{"key":"ref_8","unstructured":"Feleppa, E., Dasgupta, S., Ramachandran, S., Ketterling, J., Porter, C., Lacrampe, M., and Dail, D. (, January October). Tissue-type imaging (TTI) of prostate cancer based on ultrasonic and magnetic-resonance methods: latest developments. Vancouver, Canada."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1177\/016173460402600303","article-title":"Recent developments in tissue-type imaging (TTI) for planning and monitoring treatment of prostate cancer","volume":"26","author":"Feleppa","year":"2004","journal-title":"Ultrasonic Imaging"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1016\/j.ultras.2003.12.001","article-title":"Estimating localized oscillatory tissue motion for assessment of the underlying mechanical modulus","volume":"42","author":"Konofagou","year":"2004","journal-title":"Ultrasonics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1111\/j.1747-1567.2002.tb00069.x","article-title":"TeMPeST 1-D: An instrument for measuring solid organ soft tissue properties","volume":"26","author":"Ottensmeyer","year":"2002","journal-title":"Exp. Tech"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/0003-4975(95)00483-2","article-title":"Application of a new tactile sensor to thoracoscopic surgery: Experimental and clinical study","volume":"60","author":"Ohtsuka","year":"1995","journal-title":"Ann. Thorac. Surg"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.media.2005.05.002","article-title":"Dynamic measurement of soft tissue viscoelastic properties with a torsional resonator device","volume":"9","author":"Valtorta","year":"2005","journal-title":"Med. Image. Anal"},{"key":"ref_14","unstructured":"Hariri, A., and Zu, J.W. (September, January 30). Design of a tissue resonator indenter device for measurement of soft tissue viscoelastic properties using parametric identification. San Diego, CA, USA."},{"key":"ref_15","unstructured":"Dhar, P., Zu, J.W., and Hariri, A. (2005, January 22\u201326). A device to measure soft tissue viscoelastic properties in vivo using piezoelectric actuators. Vail, CO, USA."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.sna.2006.03.030","article-title":"Design of a resonator device for in-vivo measurement of regional tissue viscoelasticity","volume":"133","author":"Dhar","year":"2007","journal-title":"Sens. Actuat. A-Phys"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Fung, Y.C. (1993). Biomechanics: Mechanical Properties of Living Tissues, Springer-Verlag. [2nd ed]. Chapter 2.","DOI":"10.1115\/1.2901550"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/0005-1098(93)90124-C","article-title":"Gray-box modeling and identification using physical knowledge and bayesian techniques","volume":"29","author":"Tulleken","year":"1993","journal-title":"Automatica"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.automatica.2003.10.001","article-title":"Parameter estimation in stochastic grey-box models","volume":"40","author":"Kristensen","year":"2004","journal-title":"Automatica"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1109\/TAC.1978.1101840","article-title":"Convergence analysis of parametric identification methods","volume":"23","author":"Ljung","year":"1978","journal-title":"IEEE Trans. Automat. Contr"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1109\/TAC.1970.1099344","article-title":"Maximum likelihood identification of stochastic linear systems","volume":"15","author":"Kashyap","year":"1970","journal-title":"IEEE Trans. Automat. Contr"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.automatica.2006.09.009","article-title":"Maximum likelihood identification of noisy input-output models","volume":"43","author":"Diversi","year":"2007","journal-title":"Automatica"},{"key":"ref_23","unstructured":"Ljung, L (1999). System Identification: Theory for the User, Prentice Hall. [2nd ed]."},{"key":"ref_24","unstructured":"\u00c5str\u00f6m, K.J (1970). Introduction to Stochastic Control Theory, Academic Press."},{"key":"ref_25","unstructured":"Anderson, B.D., and Moore, J.B. (1979). Optimal Filtering, Prentice-Hall."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Bj\u00f6rck, A (1996). Numerical Methods for Least Squares Problems, SIAM.","DOI":"10.1137\/1.9781611971484"},{"key":"ref_27","unstructured":"Jia, M., and Zu, J. (2010, January 7\u20139). New Tissue Resonator Indenter Device and Accuracy Study through Nonlinear Finite Element Analysis. Victoria, Canada."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/1212\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:54:59Z","timestamp":1760219699000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/1\/1212"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,20]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2011,1]]}},"alternative-id":["s110101212"],"URL":"https:\/\/doi.org\/10.3390\/s110101212","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2011,1,20]]}}}