{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,26]],"date-time":"2026-07-26T19:22:16Z","timestamp":1785093736726,"version":"3.55.0"},"reference-count":44,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2011,1,25]],"date-time":"2011-01-25T00:00:00Z","timestamp":1295913600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The present paper describes the characterization of a carbon ceramic electrode modified with ferrocenecarboxylic acid (designated as CCE\/Fc) by electrochemical techniques and its detection ability for dopamine. From cyclic voltammetric experiments, it was observed that the CCE\/Fc presented a redox pair at Epa = 405 mV and Epc = 335 mV (DE = 70 mV), related to the ferrocene\/ferrocenium process. Studies showed a considerably increase in the redox currents at the same oxidation potential of ferrocene (Epa = 414 mV vs. Ag\/AgCl) in the presence of dopamine (DA), differently from those observed when using only the unmodified CCE, in which the anodic peak increase was considerably lower. From SWV experiments, it was observed that the AA (ascorbic acid) oxidation at CCE\/Fc occurred in a different potential than the DA oxidation (with a peak separation of approximately 200 mV). Moreover, CCE\/Fc did not respond to different AA concentrations, indicating that it is possible to determine DA without the AA interference with this electrode.<\/jats:p>","DOI":"10.3390\/s110201361","type":"journal-article","created":{"date-parts":[[2011,1,25]],"date-time":"2011-01-25T11:57:50Z","timestamp":1295956670000},"page":"1361-1374","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Preparation and Electrochemical Characterization of a Carbon Ceramic Electrode Modified with Ferrocenecarboxylic Acid"],"prefix":"10.3390","volume":"11","author":[{"given":"Tatiane","family":"Skeika","sequence":"first","affiliation":[{"name":"Department of Chemistry, Universidade Estadual Ponta Grossa, Avenida Carlos Cavalcanti 4748, Uvaranas, Ponta Grossa, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristiane R.","family":"Zuconelli","sequence":"additional","affiliation":[{"name":"Department of Chemistry, Universidade Estadual Ponta Grossa, Avenida Carlos Cavalcanti 4748, Uvaranas, Ponta Grossa, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio T.","family":"Fujiwara","sequence":"additional","affiliation":[{"name":"Department of Chemistry, CEDETEG\u2014Universidade Estadual do Centro-Oeste, Rua Presidente Zacarias 875, Guarapuava, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christiana A.","family":"Pessoa","sequence":"additional","affiliation":[{"name":"Department of Chemistry, Universidade Estadual Ponta Grossa, Avenida Carlos Cavalcanti 4748, Uvaranas, Ponta Grossa, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1007\/s00216-006-0992-2","article-title":"Amperometric hydrogen peroxide sensor based on a sol-gel-derived ceramic carbon composite electrode with toluidine blue covalently immobilized using 3-aminopropyltrimethoxysilane","volume":"387","author":"Thenmozhi","year":"2007","journal-title":"Anal. Bioanal. Chem"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.elecom.2005.01.013","article-title":"Electroactive ceramic carbon electrode modified with ionic liquid","volume":"7","author":"Rozniecka","year":"2005","journal-title":"Electrochem. Commun"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1007\/s10008-007-0437-7","article-title":"Solid state electrochemical of the erbium hexacyanoferrate-modified carbon ceramic electrode and its electrocatalytic oxidation of L-cysteine","volume":"12","author":"Sheng","year":"2008","journal-title":"J. Solid State Electrochem"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/j.talanta.2006.02.015","article-title":"Amperometric and voltammetric detection of hydrazine using glassy carbon electrodes modified with carbon nanotubes and catechol derivatives","volume":"70","author":"Salimi","year":"2007","journal-title":"Talanta"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ab.2009.05.047","article-title":"Nanomolar detection of hydrogen peroxide at a new polynuclear cluster of tin pentacyanonitrosylferrate nanoparticle-modified carbon ceramic electrode","volume":"392","author":"Razmi","year":"2009","journal-title":"Anal. Biochem"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1021\/ac00082a024","article-title":"Sol-gel-derived ceramic-carbon composite electrodes\u2014Introduction and scope of applications","volume":"66","author":"Tsionsky","year":"1994","journal-title":"Anal. Chem"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2354","DOI":"10.1021\/cm970367b","article-title":"Sol-gel materials in electrochemistry","volume":"9","author":"Lev","year":"1997","journal-title":"Chem. Mater"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1590\/S0100-40422002000500020","article-title":"Utiliza\u00e7\u00e3o de Materiais Obtidos pelo Processo de Sol-Gel na Constru\u00e7\u00e3o de Biossensores","volume":"25","author":"Alfaya","year":"2002","journal-title":"Quim. Nova"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1002\/1521-4109(200103)13:4<265::AID-ELAN265>3.0.CO;2-2","article-title":"Sol-gel derived composite ceramic carbon electrodes","volume":"4","author":"Rabinovich","year":"2001","journal-title":"Electroanalysis"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3893","DOI":"10.1021\/cr068035q","article-title":"Polymer\/silica nanocomposites: Preparation, characterization, properties, and applications","volume":"108","author":"Zou","year":"2008","journal-title":"Chem. Rev"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2409","DOI":"10.1021\/ac00110a014","article-title":"Electrochemical Composite Carbon\u2014Ceramic Gas Sensors: Introduction and Oxygen Sensing","volume":"67","author":"Tsionsky","year":"1995","journal-title":"Anal. Chem"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.aca.2006.01.028","article-title":"Glassy carbon ceramic composite electrodes","volume":"564","author":"Sun","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1016\/j.bios.2006.08.013","article-title":"Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in sol\u2013gel-derived ceramic\u2013carbon nanotube nanocomposite film","volume":"22","author":"Chen","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jelechem.2007.08.013","article-title":"Bismuth hexacyanoferrate-modified carbon ceramic electrodes prepared by electrochemical deposition and its electrocatalytic activity towards oxidation of hydrazine","volume":"611","author":"Zheng","year":"2007","journal-title":"J. Electroanal. Chem"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"7300","DOI":"10.1016\/j.electacta.2007.05.074","article-title":"Hydrogen peroxide determination by carbon ceramic electrodes modified with pyrocatechol violet","volume":"52","author":"Sheng","year":"2007","journal-title":"Electrochim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1016\/j.electacta.2008.06.023","article-title":"Structural and electrochemical characterization of a cobalt phthalocyanine bulk-modified SiO2\/SnO2 carbon ceramic electrode","volume":"54","author":"Arguello","year":"2009","journal-title":"Electrochim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.bioelechem.2004.06.002","article-title":"An amperometric hydrogen peroxide biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer supported by sol\u2013gel derived carbon ceramic electrode","volume":"65","author":"Leia","year":"2004","journal-title":"Bioelectrochemistry"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.electacta.2008.07.021","article-title":"Simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid by methylene blue adsorbed on a phosphorylated zirconia\u2013silica composite electrode","volume":"54","author":"Arguello","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.talanta.2003.11.021","article-title":"Enhancement of the analytical properties and catalytic activity of a nickel hexacyanoferrate modified carbon ceramic electrode prepared by two-step sol\u2013gel technique: application to amperometric detection of hydrazine and hydroxyl amine","volume":"63","author":"Salimi","year":"2007","journal-title":"Talanta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/S0003-2670(01)01405-2","article-title":"Bienzymatic amperometric biosensor for glucose based on polypyrrole\/ceramic carbon as electrode material","volume":"451","author":"Tian","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1016\/S0013-4686(01)00453-4","article-title":"Ferrocenecarboxylic acid adsorbed on Nb2O5 film grafted on a SiO2 surface: NADH oxidation study","volume":"46","author":"Pessoa","year":"2001","journal-title":"Electrochim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"7736","DOI":"10.1021\/la9004938","article-title":"High-sensitivity amperometric biosensors based on ferrocene-modified linear poly(ethylenimine)","volume":"25","author":"Merchant","year":"2009","journal-title":"Langmuir"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"6830","DOI":"10.1021\/ac901090g","article-title":"Electrocatalytic Responses at Mediator Modified Electrodes with Several Cyclic Step and Cyclic Sweep Potential Techniques. Application to the Oxidation of Ascorbate at a Ferrocene-Monolayer Modified Gold Electrode","volume":"81","author":"Molina","year":"2009","journal-title":"Anal. Chem"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1016\/j.bios.2008.01.026","article-title":"Electrochemical determination of uric-acid at ordered mesoporous carbon functionalized with ferrocenecarboxylic acid-modified electrode","volume":"23","author":"Ndamanisha","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1831","DOI":"10.1016\/j.elecom.2008.09.031","article-title":"Anthraquinone-ferrocene film electrodes: Utility in pH and oxygen sensing","volume":"10","author":"Lafitte","year":"2008","journal-title":"Electrochem. Commun"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/j.electacta.2004.08.016","article-title":"Electrochemical evaluation of ferrocene carboxylic acids confined on surfactant-clay modified glassy carbon electrodes: oxidation of ascorbic acid and uric acid","volume":"50","author":"Fernandez","year":"2005","journal-title":"Electrochim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2543","DOI":"10.1002\/elan.200703994","article-title":"Electrochemical studies of an iron porphyrin immobilized on Nb2O5\/SiO2 and its application for simultaneous determination of dopamine and ascorbic acid using multivariate calibration methodology","volume":"19","author":"Skeika","year":"2007","journal-title":"Electroanalysis"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.jelechem.2009.05.010","article-title":"Detection of dopamine based on the unique property of gold nanofilm","volume":"633","author":"Ge","year":"2009","journal-title":"J. Electroanal. Chem"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jelechem.2009.04.028","article-title":"Silver nanoparticles modified carbon nanotube paste electrode for simultaneous determination of dopamine and ascorbic acid","volume":"633","author":"Tashkhourian","year":"2009","journal-title":"J. Electroanal. Chem"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/j.talanta.2006.02.015","article-title":"Simultaneous determination of ascorbic acid, uric acid and neurotransmitters with a carbon ceramic electrode prepared by sol\u2013gel technique","volume":"70","author":"Salimi","year":"2006","journal-title":"Talanta"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.jelechem.2009.06.001","article-title":"differential pulse voltammetric method for simultaneous determination of ascorbic acid, dopamine, and uric acid using poly (3-(5-chloro-2-hydroxyphenylazo)-4,5-dihydroxynaphthalene-2,7-disulfonic acid) film modified glassy carbon electrode","volume":"633","author":"Ensafi","year":"2009","journal-title":"J. Electroanal. Chem"},{"key":"ref_32","unstructured":"Bard, A.J., and Faulkner, L.R. (1980). Electrochemical Methods, Fundamentals and Applications, Wiley."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/0020-1693(94)04052-4","article-title":"Controlling the acidity of the carbox\u00edlic group by a ferrocene based redox switch","volume":"225","author":"Fabbrizzi","year":"1994","journal-title":"Inorg. Chim. Acta"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1021\/ac60210a007","article-title":"Theory of stationary electrode polarography: single scan and cyclic methods applied to reversible, irreversible, and kinetic systems","volume":"36","author":"Nicholson","year":"1964","journal-title":"Anal. Chem"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"7416","DOI":"10.1016\/j.electacta.2009.07.089","article-title":"Application of silica gel as an effective modifier for the voltammetric determination of dopamine in the presence of ascorbic acid and uric acid","volume":"54","author":"Nasri","year":"2009","journal-title":"Electrochim. Acta"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1016\/j.elecom.2006.08.015","article-title":"Application of self-assembled \u201cmolecular wires\u201d monolayers for electroanalysis of dopamine","volume":"8","author":"Wang","year":"2006","journal-title":"Electrochem. Commun"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"(1987). Analytical Methods Committee Recomendations for definition, estimation and use of the detection limit. Analyst, 112, 199\u2013204.","DOI":"10.1039\/an9871200199"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1590\/S0100-40422007000200038","article-title":"Utiliza\u00e7\u00e3o da M\u00faltipla Voltametria de Onda Quadrada na Determina\u00e7\u00e3o Eletroanal\u00edtica de Compostos Org\u00e2nicos e Inorg\u00e2nicos","volume":"30","author":"Souza","year":"2007","journal-title":"Qu\u00edm. Nova"},{"key":"ref_39","first-page":"599","article-title":"Electrocatalytic Response of Dopamine at a Carbon Paste Electrode Modified with Ferrocene","volume":"82","author":"Kamyabi","year":"2009","journal-title":"Croat. Chem. Acta"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"5939","DOI":"10.1016\/j.electacta.2007.03.039","article-title":"Fabrication of Fc-SWNTs modified glassy carbon electrode for selective and sensitive determination of dopamine in the presence of AA and UA","volume":"52","author":"Jiao","year":"2007","journal-title":"Electrochim. Acta"},{"key":"ref_41","first-page":"1233","article-title":"Ferrocene-containing polyelectrolyte multilayer film-covered electrodes: Electrocatalytic determination of ascorbic acid and use of inner blocking layers to improve the upper detection limit of the electrodes","volume":"50","author":"Liu","year":"2005","journal-title":"Electrochim. Acta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1016\/0039-9140(95)01638-4","article-title":"Catalytic oxidation of ascorbic acid by some ferrocene derivative mediators at the glassy carbon electrode. Application to the voltammetric resolution of ascorbic acid and dopamine in the same sample","volume":"42","author":"Ojani","year":"1995","journal-title":"Talanta"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"3660","DOI":"10.1021\/ac802690s","article-title":"Method for Preparation of a Sol-Gel-Derived Carbon Ceramic Electrode Using Microwave Irradiation","volume":"81","author":"Abbaspour","year":"2009","journal-title":"Anal. Chem"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/S0925-4005(00)00741-3","article-title":"A novel ferrocene encapsulated palladium-linked ormosil-based electrocatalytic dopamine biosensor","volume":"75","author":"Pandey","year":"2001","journal-title":"Sens. Actuat. B"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1361\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:03Z","timestamp":1760219703000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1361"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,25]]},"references-count":44,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2011,2]]}},"alternative-id":["s110201361"],"URL":"https:\/\/doi.org\/10.3390\/s110201361","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,25]]}}}