{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T18:23:17Z","timestamp":1779301397485,"version":"3.51.4"},"reference-count":20,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2011,1,26]],"date-time":"2011-01-26T00:00:00Z","timestamp":1296000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this investigation, micro voltage, temperature and humidity sensors were fabricated and integrated for the first time on a stainless steel foil using micro-electro-mechanical systems (MEMS). These flexible multi-functional micro sensors have the advantages of high temperature resistance, flexibility, smallness, high sensitivity and precision of location. They were embedded in a proton exchange membrane fuel cell (PEMFC) and used to simultaneously measure variations in the inner voltage, temperature and humidity. The accuracy and reproducibility of the calibrated results obtained using the proposed micro sensors is excellent. The experimental results indicate that, at high current density and 100%RH or 75%RH, the relative humidity midstream and downstream saturates due to severe flooding. The performance of the PEM fuel cell can be stabilized using home-made flexible multi-functional micro sensors by the in-situ monitoring of local voltage, temperature and humidity distributions within it.<\/jats:p>","DOI":"10.3390\/s110201418","type":"journal-article","created":{"date-parts":[[2011,1,26]],"date-time":"2011-01-26T11:17:26Z","timestamp":1296040646000},"page":"1418-1432","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["A Novel Method for In-Situ Monitoring of Local Voltage, Temperature and Humidity Distributions in Fuel Cells Using Flexible Multi-Functional Micro Sensors"],"prefix":"10.3390","volume":"11","author":[{"given":"Chi-Yuan","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Yuan Ze Fuel Cell Center, Yuan Ze University, Taoyuan, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Yuan","family":"Fan","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Yuan Ze Fuel Cell Center, Yuan Ze University, Taoyuan, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chih-Ping","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Yuan Ze Fuel Cell Center, Yuan Ze University, Taoyuan, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"A857","DOI":"10.1149\/1.2179200","article-title":"Detection of membrane drying, fuel cell flooding and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy","volume":"153","author":"Abouatallah","year":"2006","journal-title":"J. Electrochem. Soc"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.jpowsour.2008.09.109","article-title":"Novel in situ measurements of relative humidity in a polymer electrolyte membrane fuel cell","volume":"186","author":"Hinds","year":"2009","journal-title":"J. Power Sources"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jpowsour.2005.06.027","article-title":"Water flooding and two-phase flow in cathode channels of proton exchange membrane fuel cells","volume":"156","author":"Liu","year":"2006","journal-title":"J. Power Sources"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1016\/j.jpowsour.2010.09.092","article-title":"Liquid water flooding process in proton exchange membrane fuel cell cathode with straight parallel channels and porous layer","volume":"196","author":"Wang","year":"2011","journal-title":"J. Power Sources"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.jpowsour.2007.12.068","article-title":"A review of water flooding issues in the proton exchange membrane fuel cell","volume":"178","author":"Li","year":"2008","journal-title":"J. Power Sources"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"4712","DOI":"10.1016\/j.ijheatmasstransfer.2006.07.003","article-title":"In situ investigation of water transport in an operating PEM fuel cell using neutron radiography: Part 1\u2014Experimental method and serpentine flow field results","volume":"49","author":"Trabold","year":"2006","journal-title":"Int. J. Heat Mass Transfer"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"5315","DOI":"10.1016\/j.electacta.2008.02.074","article-title":"PEM fuel cell relative humidity (RH) and its effect on performance at high temperatures","volume":"53","author":"Zhang","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.jpowsour.2009.03.021","article-title":"In-fibre Bragg Grating sensors for distributed temperature measurement in a polymer electrolyte membrane fuel cell","volume":"192","author":"David","year":"2009","journal-title":"J. Power Sources"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"4753","DOI":"10.1016\/j.jpowsour.2010.02.071","article-title":"Design of an optical thermal sensor for proton exchange membrane fuel cell temperature measurement using phosphor thermometry","volume":"195","author":"Inman","year":"2010","journal-title":"J. Power Sources"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jpowsour.2005.04.032","article-title":"Measurements of humidity and current distribution in a PEFC","volume":"155","author":"Nishikawa","year":"2006","journal-title":"J. Power Sources"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jpowsour.2005.08.012","article-title":"Temperature Distribution on the MEA surface of a PEMFC with serpentine channel flow bed","volume":"157","author":"Wang","year":"2006","journal-title":"J. Power Sources"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jpowsour.2008.10.108","article-title":"Characterization of flooding and two-phase flow in polymer electrolyte membrane fuel cell stacks","volume":"187","author":"Karimi","year":"2009","journal-title":"J. Power Sources"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.ijhydene.2006.11.032","article-title":"Numerical studies on rib & channel dimension of flow-field on PEMFC performance","volume":"32","author":"Shimpalee","year":"2007","journal-title":"Int. J. Hydrogen Energy"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jpowsour.2008.01.020","article-title":"Embedded flexible micro-sensors in MEA for measuring temperature and humidity in a micro-fuel cell","volume":"181","author":"Lee","year":"2008","journal-title":"J. Power Sources"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"6395","DOI":"10.3390\/s100706395","article-title":"In-situ monitoring of internal local temperature and voltage of proton exchange membrane fuel cells","volume":"10","author":"Lee","year":"2010","journal-title":"Sensors"},{"key":"ref_16","unstructured":"Wilson, J.S. (2004). Sensor Technology Handbook, Butterworth-Heinemann."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.1016\/j.matlet.2010.03.005","article-title":"Capacitive humidity-sensitivity of carbonized silicon nanoporous pillar array","volume":"64","author":"Wang","year":"2010","journal-title":"Mater. Lett"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/j.spmi.2010.03.006","article-title":"A ZnO nanowire-based humidity sensor","volume":"47","author":"Chang","year":"2010","journal-title":"Superlattices Microstruct"},{"key":"ref_19","first-page":"372","article-title":"High-sensitivity capacitive humidity sensor using 3-layer patterned polyimide sensing film","volume":"1","author":"Laconte","year":"2003","journal-title":"Sensors"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/S0925-4005(03)00423-4","article-title":"Porous silicon-based humidity sensor with interdigital electrodes and internal heaters","volume":"95","author":"Mescheder","year":"2003","journal-title":"Sens. Actuat. B"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1418\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:03Z","timestamp":1760219703000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1418"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,26]]},"references-count":20,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2011,2]]}},"alternative-id":["s110201418"],"URL":"https:\/\/doi.org\/10.3390\/s110201418","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,26]]}}}