{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T09:12:35Z","timestamp":1776417155179,"version":"3.51.2"},"reference-count":67,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2011,1,27]],"date-time":"2011-01-27T00:00:00Z","timestamp":1296086400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A multiwavelength, multicomponent CRDS gas sensor operating on the basis of a compact photonic crystal fibre supercontinuum light source has been constructed. It features a simple design encompassing one radiation source, one cavity and one detection unit (a spectrograph with a fitted ICCD camera) that are common for all wavelengths. Multicomponent detection capability of the device is demonstrated by simultaneous measurements of the absorption spectra of molecular oxygen (spin-forbidden b-X branch) and water vapor (polyads 4v, 4v + d) in ambient atmospheric air. Issues related to multimodal cavity excitation, as well as to obtaining the best signal-to-noise ratio are discussed together with methods for their practical resolution based on operating the cavity in a \u201cquasi continuum\u201d mode and setting long camera gate widths, respectively. A comprehensive review of multiwavelength CRDS techniques is also given.<\/jats:p>","DOI":"10.3390\/s110201620","type":"journal-article","created":{"date-parts":[[2011,1,31]],"date-time":"2011-01-31T11:44:06Z","timestamp":1296474246000},"page":"1620-1640","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["PCF-Based Cavity Enhanced Spectroscopic Sensors for Simultaneous Multicomponent Trace Gas Analysis"],"prefix":"10.3390","volume":"11","author":[{"given":"Walter M.","family":"Nakaema","sequence":"first","affiliation":[{"name":"Institute of Experimental Physics, Free University of Berlin, Arnimallee 14, 14195 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zuo-Qiang","family":"Hao","sequence":"additional","affiliation":[{"name":"Institute of Experimental Physics, Free University of Berlin, Arnimallee 14, 14195 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Rohwetter","sequence":"additional","affiliation":[{"name":"Institute of Experimental Physics, Free University of Berlin, Arnimallee 14, 14195 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ludger","family":"W\u00f6ste","sequence":"additional","affiliation":[{"name":"Institute of Experimental Physics, Free University of Berlin, Arnimallee 14, 14195 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kamil","family":"Stelmaszczyk","sequence":"additional","affiliation":[{"name":"Institute of Experimental Physics, Free University of Berlin, Arnimallee 14, 14195 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,27]]},"reference":[{"key":"ref_1","unstructured":"Sigrist, M.W. (1994). Air Monitoring by Spectroscopic Techniques, John Wiley."},{"key":"ref_2","unstructured":"Platt, U., and Stutz, J. (2008). Differential Optical Absorption Spectroscopy, Principles and Applications, Springer-Verlag."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Weitkamp, C. (2005). Lidar: Range-Resolved Optical Remote Sensing of the Atmosphere, Springer Science Inc.","DOI":"10.1007\/b106786"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"115","DOI":"10.2174\/138955707779802606","article-title":"Breath analysis: The approach towards clinical applications","volume":"7","author":"Amann","year":"2007","journal-title":"Mini Rev. Med. Chem"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1080\/10826080802344864","article-title":"Applications of breath gas analysis in addiction medicine\u2014Preliminary results","volume":"44","author":"Giacomuzzi","year":"2009","journal-title":"Subst. Use Misuse"},{"key":"ref_6","unstructured":"Zhao, E., Zhao, E., Dou, B., Zhou, H., Liu, S., Chen, A., Li, T., and Dai, G. (2005, January 4\u22129). Volatile organic compounds monitoring for semiconductor foundry clean room air. Beijing, China."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Nishimura, K., Sakaguchi, Y., Crosson, E, Wahl, E., and Rella, C. (2007, January 17\u201319). Real-time trace ambient ammonia monitor for haze prevention. Yokohama, Japan.","DOI":"10.1117\/12.728981"},{"key":"ref_8","unstructured":"Van Pelt, A., and Crosson, E. Tracking ammonia, HF, H2S, HCI, and other trace gases. Available online: http:\/\/www.cemag.us\/articles.asp?pid=802 (accessed on 3 January 2011)."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1117\/12.372839","article-title":"New spectroscopic methods for environmental measurement and monitoring","volume":"3853","author":"Steinfeld","year":"1999","journal-title":"SPIE Proc"},{"key":"ref_10","unstructured":"Spicer, J.B. (2003). Proceedings of SPIE, Detection and Remediation Technologies for Mines and Minelike Targets VIII."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.ijms.2004.08.010","article-title":"Applications of breath gas analysis in medicine","volume":"239","author":"Amann","year":"2004","journal-title":"Int. J. Mass Spectrom"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.microc.2004.10.008","article-title":"Breath analysis: Trends in techniques and clinical applications","volume":"79","author":"Di","year":"2005","journal-title":"Microchem. J"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1930","DOI":"10.1016\/S0140-6736(98)07552-7","article-title":"Volatile organic compounds in breath as markers of lung cancer: A cross-sectional study","volume":"353","author":"Phillips","year":"1999","journal-title":"Lancet"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1002\/bmc.835","article-title":"Human exhaled air analytics: Biomarkers of diseases","volume":"21","author":"Buszewski","year":"2007","journal-title":"Biomed. Chromatogr"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.jchromb.2004.05.015","article-title":"Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry","volume":"808","author":"Deng","year":"2004","journal-title":"J. Chromatogra. B"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s10549-006-9176-1","article-title":"Prediction of breast cancer using volatile biomarkers in the breath","volume":"99","author":"Phillips","year":"2006","journal-title":"Breast Cancer Res. Treat"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Nollet, L.M.L (2006). Chromatographic Analysis of the Environment, CRC Press. [3rd ed].","DOI":"10.1201\/9781420027983"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Niessen, W.M.A. (2001). Current Practice of Gas Chromatography\u2014Mass Spectrometry, Marcel Dekker.","DOI":"10.1201\/9780367801274"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Nollet, L.M.L. (2006). Chromatographic Analysis of the Environment, CRC Press. [3rd ed].","DOI":"10.1201\/9781420027983"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1029\/2002GL015044","article-title":"Cosmic ray-induced aerosol-formation: First observational evidence from aircraft-based ion mass spectrometer measurements in the upper troposphere","volume":"29","author":"Eichkorn","year":"2002","journal-title":"Geophys. Res. Lett"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"10178","DOI":"10.1364\/OE.16.010178","article-title":"Cavity enhanced absorption spectroscopy of multiple trace gas species using a supercontinuum radiation source","volume":"16","author":"Langridge","year":"2008","journal-title":"Opt. Express"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1366\/000370209790108987","article-title":"Cavity enhanced spectroscopy of high-temperature H2O in the near-infrared using a supercontinuum light source","volume":"63","author":"Watt","year":"2009","journal-title":"Appl. Spectrosc"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1139\/p05-054","article-title":"An historical overview of cavity-enhanced methods","volume":"83","author":"Paldus","year":"2005","journal-title":"Can. J. Phys"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Berden, G., and Engeln, N. (2009). Cavity Ring-Down Spectroscopy: Techniques and Applications, John Wiley and Sons.","DOI":"10.1002\/9781444308259"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1364\/AO.23.001238","article-title":"Mirror reflectometer based on optical cavity decay time","volume":"23","author":"Anderson","year":"1984","journal-title":"Appl. Opt"},{"key":"ref_26","first-page":"2544","article-title":"Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources","volume":"59","author":"Deacon","year":"1998","journal-title":"Rev. Sci. Instru"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"15013","DOI":"10.1364\/OE.16.015013","article-title":"Cavity enhanced absorption spectroscopy using a broadband prism cavity and a supercontinuum source","volume":"16","author":"Johnston","year":"2008","journal-title":"Opt. Express"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.1016\/j.elecom.2008.09.014","article-title":"Evanescent wave broadband cavity enhanced absorption spectroscopy using supercontinuum radiation: A new probe of electrochemical processes","volume":"10","author":"Schnippering","year":"2008","journal-title":"Electrochem. Commun"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1039\/B916712A","article-title":"Following interfacial kinetics in real time using broadband evanescent wave cavity-enhanced absorption spectroscopy: A comparison of light-emitting diodes and supercontinuum sources","volume":"135","author":"Hancock","year":"2010","journal-title":"Analyst"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/S0009-2614(97)00407-7","article-title":"Cavity ringdown spectroscopy: Broad band absolute absorption measurements","volume":"270","author":"Romanini","year":"1997","journal-title":"Chem. Phys. Lett"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1366\/000370203321666614","article-title":"Use of broadband, continuous-wave diode lasers in cavity ring-down spectroscopy for liquid samples","volume":"57","author":"Hallock","year":"2003","journal-title":"Appl. Spectrosc"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.jms.2004.05.020","article-title":"High sensitivity CW-cavity ring down spectroscopy of water in the region of the 1.5 \u03bcm atmospheric window","volume":"227","author":"Macko","year":"2004","journal-title":"J. Mol. Spectrosc"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/j.saa.2009.12.013","article-title":"Cavity ring-down observation of Yb3+ optical absorption in room temperature solution","volume":"75","author":"Kirmiz","year":"2010","journal-title":"Spectrochimica Acta Part A: Molecular Biomolecular Spectrosc"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"8745","DOI":"10.1364\/OE.15.008745","article-title":"Noise in cavity ring-down spectroscopy caused by transverse mode coupling","volume":"15","author":"Huang","year":"2007","journal-title":"Opt. Express"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"10278","DOI":"10.1063\/1.472956","article-title":"Response of a ring-down cavity to an arbitrary excitation","volume":"105","author":"Hodges","year":"1996","journal-title":"J. Chem. Phys"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1063\/1.1149533","article-title":"Pulse-stacked cavity ring-down spectroscopy","volume":"70","author":"Crosson","year":"1999","journal-title":"Rev. Sci. Instrum"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1126\/science.1123921","article-title":"Broadband cavity ringdown spectroscopy for sensitive and rapid molecular detection","volume":"311","author":"Thorpe","year":"2006","journal-title":"Science"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2708","DOI":"10.1063\/1.1147092","article-title":"A Fourier transform cavity ring down spectrometer","volume":"67","author":"Engeln","year":"1996","journal-title":"Rev. Sci. Instrum"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/S0009-2614(02)01457-4","article-title":"Fourier transform phase shift cavity ring down spectroscopy","volume":"365","author":"Hamers","year":"2002","journal-title":"Chem. Phys. Lett"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0009-2614(98)00653-8","article-title":"Ringdown spectral photography","volume":"292","author":"Scherer","year":"1998","journal-title":"Chem. Phys. Lett"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"6725","DOI":"10.1364\/AO.40.006725","article-title":"Broadband ringdown spectral photography","volume":"40","author":"Scherer","year":"2001","journal-title":"Appl. Opt"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/S0009-2614(01)00573-5","article-title":"Broadband cavity ringdown spectroscopy of the NO3 radical","volume":"342","author":"Ball","year":"2001","journal-title":"Chem. Phys. Lett"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"5239","DOI":"10.1021\/cr020523k","article-title":"Broad-band cavity ring-down spectroscopy","volume":"103","author":"Ball","year":"2003","journal-title":"Chem. Rev"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0030-4018(01)01134-8","article-title":"Cavity ring-down spectrography","volume":"191","author":"Chudzynski","year":"2001","journal-title":"Opt. Commun"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s00340-008-3320-z","article-title":"Towards supercontinuum cavity ring-down spectroscopy","volume":"94","author":"Stelmaszczyk","year":"2009","journal-title":"Appl. Phys. B: Lasers Opt"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"053856-5","DOI":"10.1103\/PhysRevA.79.053856","article-title":"White-light symmetrization by the interaction of multifilamenting beams","volume":"79","author":"Stelmaszczyk","year":"2009","journal-title":"Phys. Rev. A"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"013812","DOI":"10.1103\/PhysRevA.77.013812","article-title":"Laser multiple filamentation control in air using a smooth phase mask","volume":"77","author":"Rohwetter","year":"2008","journal-title":"Phy. Rev. A"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"3673","DOI":"10.1364\/OE.17.003673","article-title":"Cavity ring-down absorption spectrography based on filament-generated supercontinuum light","volume":"17","author":"Stelmaszczyk","year":"2009","journal-title":"Opt. Express"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"6754","DOI":"10.1364\/AO.48.006754","article-title":"Spectrally resolved cavity ring down measurement of high reflectivity mirrors using a supercontinuum laser source","volume":"48","author":"Schmidl","year":"2009","journal-title":"Appl. Opt"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Baselt, T., Hammer, T., Basan, F., and Hartmann, P. (2009, January 26). Application of a microchip laser-pumped photonic crystal fibre supercontinuum source for high-sensitive cavity ring down optical loss measurements. San Jose, CA, USA.","DOI":"10.1117\/12.809324"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s10043-999-0381-0","article-title":"Optics of photonic crystals","volume":"6","author":"Sakoda","year":"1999","journal-title":"Opt. Rev"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1364\/JOSAB.27.000592","article-title":"Ultraviolet-enhanced supercontinuum generation in tapered photonic crystal fibre","volume":"27","author":"Stark","year":"2010","journal-title":"J. Opt. Soc. Ame. B"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.1364\/OL.27.001558","article-title":"Long-wavelength continuum generation about the second dispersion zero of a tapered fibre","volume":"27","author":"Harbold","year":"2002","journal-title":"Opt. Lett"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1364\/JOSAB.19.002148","article-title":"Supercontinuum generation in photonic crystal fibres and optical fibre tapers: A novel light source","volume":"19","author":"Wadsworth","year":"2002","journal-title":"J. Opt. Soc. Ame. B"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1049\/el:20010395","article-title":"Compact broadband continuum source based on microchip laser pumped microstructured fibre","volume":"37","author":"Provino","year":"2001","journal-title":"Electron. Lett"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1364\/OPEX.12.000299","article-title":"Supercontinuum and four-wave mixing with Q-switched pulses in endlessly single-mode photonic crystal fibres","volume":"12","author":"Wadsworth","year":"2004","journal-title":"Opt. Express"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1364\/OL.28.001353","article-title":"Continuous-wave, high-power, Raman continuum generation in holey fibres","volume":"28","author":"Avdokhin","year":"2003","journal-title":"Opt. Lett"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1103\/RevModPhys.78.1135","article-title":"Supercontinuum generation in photonic crystal fibre","volume":"78","author":"Dudley","year":"2006","journal-title":"Rev. Modern Phys"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1146\/annurev-anchem-060908-155248","article-title":"Cavity-enhanced direct frequency comb spectroscopy: Technology and applications","volume":"3","author":"Adler","year":"2010","journal-title":"Ann. Rev. Anal. Chem"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/0009-2614(93)E1361-J","article-title":"Coherent cavity ring down spectroscopy","volume":"217","author":"Meijer","year":"1994","journal-title":"Chem. Phys. Lett"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"7239","DOI":"10.1364\/AO.44.007239","article-title":"Off-axis cavity ringdown spectroscopy: Application to atmospheric nitrate radical detection","volume":"44","author":"Ayers","year":"2005","journal-title":"Appl. Opt"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1364\/OE.14.001304","article-title":"De Combining a difference-frequency source with an off-axis high-finesse cavity for trace-gas monitoring around 3 um","volume":"14","author":"Malara","year":"2006","journal-title":"Opt. Express"},{"key":"ref_63","unstructured":"Layertec\u2014Optical Coating Optics GmbH. Available online: http:\/\/www.layertec.de (accessed on 1 January 2011)."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1364\/OE.11.001106","article-title":"Design criteria for Herriott-type multi-pass cavities for ultrashort pulse lasers","volume":"11","author":"Sennaroglu","year":"2003","journal-title":"Opt. Express"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1088\/0957-0233\/7\/9\/003","article-title":"A low-cost gated integrator boxcar averager","volume":"7","author":"Collier","year":"1996","journal-title":"Meas. Sci. Technol"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1175\/1520-0450(1981)020<1527:NEFCVP>2.0.CO;2","article-title":"New equations for computing vapor pressure and enhancement factor","volume":"20","author":"Buck","year":"1981","journal-title":"J. Appl. Meteorol"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/S0022-4073(03)00146-8","article-title":"The HITRAN molecular spectroscopic database: Edition of 2000 including updates through 2001","volume":"82","author":"Rothman","year":"2003","journal-title":"J. Quant. Spectrosco. Radiat"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1620\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:05Z","timestamp":1760219705000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1620"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,27]]},"references-count":67,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2011,2]]}},"alternative-id":["s110201620"],"URL":"https:\/\/doi.org\/10.3390\/s110201620","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,27]]}}}