{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T03:32:39Z","timestamp":1778211159517,"version":"3.51.4"},"reference-count":12,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2011,1,31]],"date-time":"2011-01-31T00:00:00Z","timestamp":1296432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.<\/jats:p>","DOI":"10.3390\/s110201784","type":"journal-article","created":{"date-parts":[[2011,1,31]],"date-time":"2011-01-31T11:44:06Z","timestamp":1296474246000},"page":"1784-1793","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device"],"prefix":"10.3390","volume":"11","author":[{"given":"Sang-Suk","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Oriental Biomedical Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-Hyun","family":"Nam","sequence":"additional","affiliation":[{"name":"Department of Biofunctional Medicine and Diagnosis, Oriental Medical College, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"You-Sik","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Computer Science Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Woo-Beom","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Computer Science Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Il-Ho","family":"Son","sequence":"additional","affiliation":[{"name":"Department of Oriental Biomedical Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keun-Ho","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Oriental Biomedical Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong-Gu","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Western-Eastern Biomedical Engineering, Sangji University, Wonju 220-702, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,1,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1152\/ajpheart.1993.265.1.H52","article-title":"Neutral Axis Location in Bending and Young\u2019s Modulus of Different Layers of Arterial Wall","volume":"265","author":"Tu","year":"1993","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1109\/TBME.2008.919142","article-title":"Cuffless Blood Pressure Monitoring Using Hydrostatic Pressure Changes","volume":"55","author":"Shaltis","year":"2008","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"588","DOI":"10.5694\/j.1326-5377.2002.tb04590.x","article-title":"Ambulatory Blood Pressure Monitoring","volume":"176","author":"McGrath","year":"2002","journal-title":"Med. J. Aust"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"34","DOI":"10.4283\/JMAG.2008.13.1.034","article-title":"Development of Micro-Size Search Coil Magnetometer for Magnetic Field Distribution Measurement","volume":"13","author":"Ka","year":"2008","journal-title":"J. Magnet"},{"key":"ref_5","first-page":"216","article-title":"Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by Using Multi-Hall Devices","volume":"16","author":"Choi","year":"2006","journal-title":"J. Kor. Mag. Soc"},{"key":"ref_6","unstructured":"O\u2019Rourke, M.F.P., Kelly, R.P., and Avolio, A.P. (1992). The Arterial Pulse, Lea & Febiger. [1st ed]."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"R908","DOI":"10.1063\/1.2177388","article-title":"Improvement of Pulse Diagnostic Apparatus with Array Sensor of Magnetic Tunneling Junctions","volume":"99","author":"Kim","year":"2006","journal-title":"J. Appl. Phys"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e983","DOI":"10.1016\/j.jmmm.2006.10.1027","article-title":"Development of Spatial Pulse Diagnostic Apparatus with Magnetic Sensor Array","volume":"310","author":"Choi","year":"2007","journal-title":"J. Magn. Magn. Maters"},{"key":"ref_9","first-page":"721","article-title":"Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices","volume":"28","author":"Lee","year":"2007","journal-title":"J. Biomed. Eng. Res"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"132","DOI":"10.4283\/JMAG.2009.14.3.132","article-title":"A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices","volume":"14","author":"Lee","year":"2009","journal-title":"J. Magnet"},{"key":"ref_11","unstructured":"Sze, S.M. (1981). Physics of Semiconductor Devices, John Wiley & Sons. [2nd ed]."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"10","DOI":"10.7326\/0003-4819-138-1-200301070-00006","article-title":"Systolic Pressure, Diastolic Blood Pressure, and Pulse Pressure as Predictors of Risk for Congestive Heart Failure in the Framingham Heart Study","volume":"138","author":"Haider","year":"2006","journal-title":"Ann. Inter. Medi"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1784\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:08Z","timestamp":1760219708000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/2\/1784"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,31]]},"references-count":12,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2011,2]]}},"alternative-id":["s110201784"],"URL":"https:\/\/doi.org\/10.3390\/s110201784","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,31]]}}}