{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T17:52:52Z","timestamp":1791913972311,"version":"4.3.4"},"reference-count":35,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2011,3,7]],"date-time":"2011-03-07T00:00:00Z","timestamp":1299456000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Accurate filtering of physiological tremor is extremely important in robotics assisted surgical instruments and procedures. This paper focuses on developing single stage robust algorithms for accurate tremor filtering with accelerometers for real-time applications. Existing methods rely on estimating the tremor under the assumption that it has a single dominant frequency. Our time-frequency analysis on physiological tremor data revealed that tremor contains multiple dominant frequencies over the entire duration rather than a single dominant frequency. In this paper, the existing methods for tremor filtering are reviewed and two improved algorithms are presented. A comparative study is conducted on all the estimation methods with tremor data from microsurgeons and novice subjects under different conditions. Our results showed that the new improved algorithms performed better than the existing algorithms for tremor estimation. A procedure to separate the intended motion\/drift from the tremor component is formulated.<\/jats:p>","DOI":"10.3390\/s110303020","type":"journal-article","created":{"date-parts":[[2011,3,8]],"date-time":"2011-03-08T09:11:15Z","timestamp":1299575475000},"page":"3020-3036","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":108,"title":["Estimation of Physiological Tremor from Accelerometers for Real-Time Applications"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1542-8627","authenticated-orcid":false,"given":"Kalyana C.","family":"Veluvolu","sequence":"first","affiliation":[{"name":"School of Electronics Engineering, Kyungpook National University, Daegu, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei Tech","family":"Ang","sequence":"additional","affiliation":[{"name":"School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2011,3,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1002\/mus.1063","article-title":"The pathophysiology of tremor","volume":"24","author":"Deuschl","year":"2001","journal-title":"Muscle Nerve"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/mds.870131303","article-title":"Consensus statement of movement disorder society on tremor. Ad hoc scientific committee","volume":"13","author":"Deuschl","year":"1998","journal-title":"Movement Disord"},{"key":"ref_3","unstructured":"Elble, RJ, and Koller, WC (1985). Tremor, John Hopkins University Press."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1109\/TNSRE.2007.903917","article-title":"Design and validation of a rehabilitation robotic exoskeleton for Tremor assesment and suppression","volume":"15","author":"Rocon","year":"2007","journal-title":"IEEE Trans. Neural Syst. Reh. En"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1093\/brain\/121.11.2127","article-title":"Time-frequency analysis of tremors","volume":"121","author":"OSuilleabhain","year":"1998","journal-title":"Brain"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0165-0270(97)02263-2","article-title":"Adaptive Fourier modeling for quantification of tremor","volume":"74","author":"Riviere","year":"1997","journal-title":"J. Nuerosci. Meth"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.3390\/s100302129","article-title":"Real-time estimation of tremor parameters from gyroscope data","volume":"10","author":"Gallego","year":"2010","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1109\/TITB.2008.2006403","article-title":"Extraction of sources of tremor in hand movements of patients with movement disorders","volume":"13","author":"Vinjamuri","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Med"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1002\/rcs.340","article-title":"Estimation and filtering of physiological tremor for surgical robotics applications","volume":"6","author":"Veluvolu","year":"2010","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg"},{"key":"ref_10","unstructured":"Taylor, RH, Lavellee, S, Burdea, GC, and Mosges, R (1996). Computer Integrated Surgery: Technology and Clinical Applications, MIT Press."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1109\/TRA.2003.817506","article-title":"Toward active tremor canceling in handheld microsurgical instruments","volume":"19","author":"Riviere","year":"2003","journal-title":"IEEE Trans. Robotics Automat"},{"key":"ref_12","first-page":"878","article-title":"An active hand-held instrument for enhanced microsurgical accuracy","volume":"1935","author":"Ang","year":"2000","journal-title":"MICCAI"},{"key":"ref_13","unstructured":"Zhang, J, Chu, F, and Mohammed, N (2005, January 8\u201310). DSP controller based signal processing of physiological hand tremor. Portland, OR, USA."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.measurement.2004.04.005","article-title":"Numerical double integration of acceleration measurements in noise","volume":"36","author":"Thong","year":"2004","journal-title":"Measurement"},{"key":"ref_15","unstructured":"Latt, WT, Tan, UX, Veluvolu, KC, Shee, CY, and Ang, WT (, January December). Physiological tremor sensing using only accelerometers for real-time compensation. Bangkok, Thailand."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1109\/10.841338","article-title":"Optimal digital filtering for tremor suppression","volume":"47","author":"Gonzalez","year":"2000","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_17","unstructured":"Zhang, J, and Chu, F (2005, January 18\u201323). Real-time modeling and prediction of physiological hand tremor. Philadelphia, PA, USA."},{"key":"ref_18","unstructured":"Oppenheim, AV, and Schaefer, RW (2001). Discrete-Time Signal Processing, Prentice-Hall."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Rahimi, M, and Karwowski, W (1992). Human Robot Interaction, Taylor & Francis Ltd.","DOI":"10.1201\/b12577"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1109\/51.499755","article-title":"Modeling and canceling tremor in human-machine interfaces","volume":"15","author":"Riviere","year":"1996","journal-title":"IEEE Eng. Med. Biol"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/78.258116","article-title":"An adaptive estimation of periodic signals using a Fourier linear combiner","volume":"42","author":"Vaz","year":"1994","journal-title":"IEEE Trans. Signal Process"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Veluvolu, KC, Tan, UX, Latt, WT, Shee, CY, and Ang, WT (2007, January 23\u201326). Bandlimited multiple Fourier linear combiner for real-time tremor compensation. Lyon, France.","DOI":"10.1109\/IEMBS.2007.4352922"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Win, TL, Tan, UX, Shee, CY, and Ang, WT (2007, January 10\u201314). Design and calibration of an optical micro motion sensing system for micromnipulation tasks. Roma, Italy.","DOI":"10.1109\/ROBOT.2007.363995"},{"key":"ref_24","unstructured":"Win, TL, Tan, UX, Veluvolu, KC, Lin, JKD, Shee, CY, and Ang, WT (2007, January 23\u201326). System to access accuracy of micromanipulation. Lyon, France."},{"key":"ref_25","unstructured":"Veluvolu, KC, Wang, Y, and Kavuri, S (2010, January 22\u201323). BMFLC based Time-frequency decomposition of EEG for event-related desynchronization detection. Seoul, Korea."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1109\/10.686791","article-title":"Adaptive cancelling of physiological tremor for improved precision in microsurgery","volume":"45","author":"Riviere","year":"1998","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Widrow, B, and Stearns, SD (1985). Adaptive Signal Processing, Prentice-Hall.","DOI":"10.1016\/B978-0-08-030565-3.50007-1"},{"key":"ref_28","unstructured":"Haykin, S (2001). Adaptive Filter Theory, Prentice-Hall."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1109\/79.295229","article-title":"A state-space approach to adaptive RLS filtering","volume":"11","author":"Sayed","year":"1994","journal-title":"IEEE Signal Process. Mag"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1115\/1.3658902","article-title":"New results in linear filtering and prediction theory","volume":"83","author":"Kalman","year":"1961","journal-title":"Trans. ASME"},{"key":"ref_31","unstructured":"Anderson, BDO, and Moore, JB (1979). Optimal Filtering, Prentice Hall."},{"key":"ref_32","unstructured":"Balakrishnan, AV (1984). Kalman Filtering Theory, Optimization Software Inc., Publications Division."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Shumway, RH, and Stoffer, DS (2000). Time Series Analysis and Its Applications, Springer.","DOI":"10.1007\/978-1-4757-3261-0"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1109\/TBME.2003.821029","article-title":"Estimation of nonstationary EEG with Kalman smoother approach: An application to event-related synchronization (ERS)","volume":"51","author":"Tarvainen","year":"2004","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1109\/JSEN.2008.917488","article-title":"Estimating displacement of periodic motion with inertial sensors","volume":"8","author":"Tan","year":"2008","journal-title":"IEEE Sens. J"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/3\/3020\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:28Z","timestamp":1760219728000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/3\/3020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3,7]]},"references-count":35,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2011,3]]}},"alternative-id":["s110303020"],"URL":"https:\/\/doi.org\/10.3390\/s110303020","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,3,7]]}}}